Electrochemical ImpedanceElectrochemical Impedance Spectroscopy: Theory and Application
Dr. Jacob KetterGamry Instruments
www gamry com
Leaders in Corrosion Control Technology
www.gamry.com
Electrochemical Impedance Spectroscopy: EIS
• Basics of EIS– What Impedance is– How to run EIS– Circuit Elements/Equivalent Circuits– EIS instrumentation
• EIS for Corrosion
Leaders in Corrosion Control Technology
• EIS for Corrosion– General Corrosion– Coatings and Passive Films
Impedance
• The term impedance refers to the frequency dependant resistance to current flow of a circuitdependant resistance to current flow of a circuit element (resistor, capacitor, inductor,etc.)
• Impedance assumes an AC current of a specific frequency in Hertz (cycles/s).
• Impedance: Z = E/I• E = Frequency-dependent potential• I = Frequency-dependent current
Leaders in Corrosion Control Technology
q y p
• Ohm’s Law: R = E/I– R = impedance at the limit of zero frequency
Some Trigonometry
A voltage excitation has the form:
)sin()sin(
)sin()sin(
00
ttZ
tItE
IEZ t
The resulting current has the form:
t)sin( E=E 0t
)+t (sin I=I 0t
Ohm’s Law becomes:
Leaders in Corrosion Control Technology
)sin()sin(0 ttIIt
The impedance is expressed in terms of a magnitude, Zo, and a phase shift, .
3/2/2011
2
Making EIS Measurements• Apply a small sinusoidal perturbation
(potential or current) of fixed frequency(potential or current) of fixed frequency • Measure the response and compute the
impedance at each frequency.• Z = E/I
• Repeat for a wide range of frequencies• Plot and analyze
Leaders in Corrosion Control Technology
• Plot and analyze
Excitation and Response in EISApplied Voltage
Measured CurrentPhaseShift
Mag
nitu
de
Current Magnitude
Leaders in Corrosion Control Technology
Time
Voltage Magnitude
EIS Data Presentation
• EIS data may be displayed as either a vector y p yor a complex quantity.
• A vector is defined by the impedance magnitude and the phase angle.
• As a complex quantity, Ztotal = Zreal + Zimag
• The vector and the complex quantity are
Leaders in Corrosion Control Technology
The vector and the complex quantity are different representations of the impedance and are mathematically equivalent.
Vector and Complex Plane Representations of EIS
Vector Complex Plane
ary
Impe
danc
e, Z
”
Leaders in Corrosion Control Technology
Real Impedance, Z’
Imag
ina
= Phase Angle
3/2/2011
3
EIS data may be presented as a Bode Plot or a Complex Plane (Nyquist) Plot
3.60 10.00
2.60
2.80
3.00
3.20
3.40
Log
Mod
ulus
(O
hm)
-50.00
-40.00
-30.00
-20.00
-10.00
0.00
Pha
se (D
egre
e)
3 00E+02
8.00E+02
1.30E+03
1.80E+03
2.30E+03
-Imag
(Ohm
)
Bode Plot
Nyquist Plot
Leaders in Corrosion Control Technology
2.20
2.40
-3.00 -2.00 -1.00 0.00 1.00 2.00 3.00 4.00 5.00 6.00
Log Freq (Hz)
-70.00
-60.00
-2.00E+02
3.00E+02
0.00E+00 5.00E+02 1.00E+03 1.50E+03 2.00E+03 2.50E+03 3.00E+03 3.50E+03
Real (Ohm)
Bode Plot• Individual charge
Nyquist Plot• Individual charge transfer
Bode vs. Nyquist Plot
Individual charge transfer processes are resolvable.
• Frequency is explicit.• Small impedances in
presence of large impedances can be
Individual charge transfer processes may be more easily resolved.
• Frequency is not obvious.• Small impedances can be
swamped by large impedances
Leaders in Corrosion Control Technology
impedances can be identified easily.
impedances.
Analyzing EIS: Modeling
• Electrochemical cells can be modeled as a t k f i l t i l i it l tnetwork of passive electrical circuit elements.
• A network is called an “equivalent circuit”.• The EIS response of an equivalent circuit can
be calculated and compared to the actual EIS response of the electrochemical cell.
Leaders in Corrosion Control Technology
Frequency Response of Electrical Circuit Elements
R i t C it I d tResistor Capacitor InductorZ = R (Ohms) Z = -j/C (Farads) Z = jL (Henrys)0° Phase Shift -90° Phase Shift 90° Phase Shift
• j = -1
Leaders in Corrosion Control Technology
• = 2f radians/s, f = frequency (Hz or cycles/s)• A real response is in-phase (0°) with the excitation. An
imaginary response is ±90° out-of-phase.
3/2/2011
4
EIS of a ResistorApplied Voltage
Measured CurrentPhase
Shift of 0º
Mag
nitu
de
Leaders in Corrosion Control Technology
Time
EIS of a CapacitorApplied Voltage
Measured CurrentPhase
Shift of 90º
Mag
nitu
de
Leaders in Corrosion Control Technology
Time
Electrochemistry as a Circuit
• Double Layer CapacitanceCapacitance
• Electron Transfer Resistance
• Uncompensated (electrolyte)
Leaders in Corrosion Control Technology
(electrolyte) Resistance
Randles Cell(Simplified)
Bode Plot
3.20
3.40
3.60
-10.00
0.00
10.00
Ru + Rp
2.60
2.80
3.00
Log
Mod
ulus
(O
hm)
-50.00
-40.00
-30.00
-20.00
Pha
se (D
egre
e)
Phase Angle
Impedance
Ru
Leaders in Corrosion Control Technology
2.20
2.40
-3.00 -2.00 -1.00 0.00 1.00 2.00 3.00 4.00 5.00 6.00
Log Freq (Hz)
-70.00
-60.00
Ru
3/2/2011
5
Complex Plane (Nyquist) Plot
1.80E+03
2.30E+03
High Freq Low Freq
3 00E+02
8.00E+02
1.30E+03
-Imag
(Ohm
)g q q
Leaders in Corrosion Control Technology
-2.00E+02
3.00E+02
0.00E+00 5.00E+02 1.00E+03 1.50E+03 2.00E+03 2.50E+03 3.00E+03 3.50E+03
Real (Ohm)
Ru Ru + Rp
Nyquist Plot with Fit
1.80E+03
2.30E+03
3.00E+02
8.00E+02
1.30E+03
-Imag
(Ohm
)
ResultsRp = 3.019E+03 ±
1.2E+01
Ru = 1.995E+02 ±1.1E+00
Leaders in Corrosion Control Technology
-2.00E+020.00E+00 5.00E+02 1.00E+03 1.50E+03 2.00E+03 2.50E+03 3.00E+03 3.50E+03
Real (Ohm)
Cdl = 9.61E-07 ± 7E-09
Other Modeling Elements
• Warburg Impedance: General impedance whichWarburg Impedance: General impedance which represents a resistance to mass transfer, i.e., diffusion control. A Warburg typically exhibits a 45° phase shift.– Open, Bound, Porous Bound
• Constant Phase Element: A very general
Leaders in Corrosion Control Technology
• Constant Phase Element: A very general element used to model “imperfect” capacitors. CPE’s normally exhibit a 80-90° phase shift.
Mass Transfer and Kinetics - Spectra
5001 104
100
200
300
400
500
( )imag i 10
100
1000
0.001 0.01 0.1 1 10 100 1000 1 1041 105
magi
freqi
0
Leaders in Corrosion Control Technology
00 100 200 300 400 500
reali
100
50
0.001 0.01 0.1 1 10 100 1000 1 1041 105
phase i
freqi
3/2/2011
6
EIS Modeling
• Complex systems may require complex d lmodels.
• Each element in the equivalent circuit should correspond to some specific activity in the electrochemical cell.
• It is not acceptable to simply add elements til d fit i bt i d
Leaders in Corrosion Control Technology
until a good fit is obtained.• Use the simplest model that fits the data.
Criteria For Valid EIS• Linear: The system obeys Ohm’s Law, E = iZ. The
value of Z is independent of the magnitude of the perturbation If linear no harmonics are generatedperturbation. If linear, no harmonics are generated during the experiment.
• Stable: The system does not change with time and returns to its original state after the perturbation is removed.
Leaders in Corrosion Control Technology
• Causal: The response of the system is due only to the applied perturbation.
Electrochemistry: A Linear System?Circuit theory is simplified when the system is “linear”. Z in a linear system is independent of excitation amplitude. The response of a linear system is always at the excitation frequency (no harmonics
t d)are generated).
Look at a small enough region of a current versus voltage curve and it becomes linear.
If the excitation is too big, harmonics are generated and EIS modeling does not work.
•Current
•Voltage
Leaders in Corrosion Control Technology
not work.
The non-linear region can be utilized.
Electrochemistry: A Stable System?Impedance analysis only works if the system being measured is stable (for the duration of the experiment).
An EIS experiment may take up to several hours to run.
Electrochemical (Corroding) systems may exhibit drift.
Open circuit potential should be checked at the beginning and end of th i t
•Current
•Voltage
Leaders in Corrosion Control Technology
the experiment.
Kramers-Kronig may help.
3/2/2011
7
Kramers-Kronig Transform• The K-K Transform states that the phase and magnitude in a
real (linear, stable, and causal) system are related.
• Apply the Transform to the EIS data. Calculate the magnitude from the experimental phase. If the calculated magnitudes match the experimental magnitudes, then you can have some confidence in the data. The converse is also true.
• If the values do not match, then the probability is high that your t i t li t t bl t l
Leaders in Corrosion Control Technology
system is not linear, not stable, or not causal.
• The K-K Transform as a validator of the data is not accepted by all of the electrochemical community.
Steps to Doing Analysis
• Look at data(R K K)– (Run K-K)
– Determine number of RC loops– Figure whether W exists
• If so determine boundary conditions• Pick/design a model
– Randles as starting point• Fit it
Check to see if CPEs needed
Leaders in Corrosion Control Technology
– Check to see if CPEs needed• Repeat as necessary• Extract data
EIS Instrumentation
• Sine wave generator• Time synchronization (phase locking)• Potentiostat/Galvanostat• All-in-ones, Portable & Floating SystemsThings to be aware of…• Software/Control
Leaders in Corrosion Control Technology
Software/Control• Accuracy• Performance limitations
Accuracy and System Limits
• Check Your Potentiostat…To Understand a System and Its Limits– To Understand a System and Its Limits
– Comparison 2+ Different Systems– Manufacturer Specifications:
• Are Not Standardized• Do Not Tell the Whole Story
– For EIS: Setup Matters
Leaders in Corrosion Control Technology
3/2/2011
8
EIS: Accuracy Contour Plot
• A complete ACP shows total, normal system performance (see right)system performance (see right)
• Preferably collected using normal operating parameters (e.g. 10 mV potentiostatic EIS)
• May also be optimized for each point/region
• Takes a long time to measure and
Leaders in Corrosion Control Technology
Takes a long time to measure and determine
• Open and Shorted Lead EIS spectra are Not the ACP
Reasons To Run EIS
• EIS is theoretically complex (and can be expensive) –h b th ?why bother?
– EIS is a non-destructive technique– The information content of EIS is much higher than DC
techniques like polarization resistance.– If two or more electrochemical reactions are taking place,
EIS may be able to distinguish between them.– EIS can identify diffusion-limited reactions, e.g., diffusion
Leaders in Corrosion Control Technology
y , g ,through a passive film.
– EIS provides information on the capacitive behavior of the system. This is always useful, but particularly for coatings.
EIS of Corrosion and Coatings• Impedance from a tens of Ω to over several GΩ
EIS f l i l k t R (b it lf)• EIS of general corrosion looks to measure Rp (by itself)• Corrosion events like pitting/passivation can be identified with
EIS, but complicate analysis
• Insulating coatings model as (very) small capacitors
• EIS is often used in conjunction with stress to measure how coatings/ surfaces change/breakdown
Leaders in Corrosion Control Technology
change/breakdown
• Systems can exhibit drift• Diffusion related events may occur
430 SS in H2SO4, Randles Model
• Data from a 430 Stainless SteelStainless Steel sample
Leaders in Corrosion Control Technology
3/2/2011
9
430 Stainless Steel, CPE Model
• Same Data Fit to CPE d lCPE model
Leaders in Corrosion Control Technology
Randles versus CPE model
Leaders in Corrosion Control Technology
Bode Plot of Carbon Steel in Aerated Water with 1000 ppm Cl-
Impedance
Phase Angle
Leaders in Corrosion Control TechnologySilverman et al, Corrosion, 44, 280 (1988).
Complex Plane Plot of Carbon Steel in Aerated Water with 1000 ppm Cl-
Warburg Impedance, evidence of diffusion
control
Leaders in Corrosion Control Technology
3/2/2011
10
EIS of Passive Films and Coatings
• Because of the barrier properties, a coated metal substrate may initially exhibit a very high impedance
10(>1010 Ω).• A high impedance sample will exhibit low cell currents
which are more difficult to measure.– Use a system designed for low-current applications.– Use a Faraday Cage.
• It may be necessary to increase the AC amplitude to 30-
Leaders in Corrosion Control Technology
It may be necessary to increase the AC amplitude to 3050 mV to see a measurable current.
• Use of larger sample areas will improve results.
Capacitive Drift (Challenges of Very Good Barrier Coatings)
• An undamaged intact coating is a capacitorTh bi t f t l l h thi• The bias current of a system slowly charges this capacitor, causing what appears to be a drift in EOC.
• Unless checked, the EOC will continue to increase, and can reach values over 5 volts.
• To obtain the “first” EIS measurement, use an applied DC voltage that is equal to the EOC of the metal
Leaders in Corrosion Control Technology
substrate.• As exposure time increases, a stable EOC may be
observed.
Experimental Procedure
• EIS is a very sensitive detector of coating conditioncondition
• Only look at relative changes• Need a stress mechanism to induce failure• As EIS is non destructive, failure can be tracked
with time
Leaders in Corrosion Control Technology
Description of Coated Surface
Leaders in Corrosion Control Technology
3/2/2011
11
Evaluation of Coated samples
• Degradation can be described in 5 stages:– Capacitive– Water Uptake– Pore Resistance– Corrosion Initiation– Major Damage
Leaders in Corrosion Control Technology
Stage One: Capacitive
Leaders in Corrosion Control Technology
Stage One: Capacitive
Leaders in Corrosion Control Technology
Stage Two: Water Uptake
Leaders in Corrosion Control Technology
3/2/2011
12
Stage Two: Water Uptake
Leaders in Corrosion Control Technology
Stage Three: Pore Resistance
Leaders in Corrosion Control Technology
Stage Three: Pore Resistance
Leaders in Corrosion Control Technology
Stage Four: Corrosion Initiation
Leaders in Corrosion Control Technology
3/2/2011
13
Stage Four: Corrosion Initiation
Leaders in Corrosion Control Technology
Stage Five: Major Damage
Leaders in Corrosion Control Technology
Stage Five: Major Damage
Leaders in Corrosion Control Technology
Example: Aluminum
Leaders in Corrosion Control Technology
3/2/2011
14
Example: Aluminum
Leaders in Corrosion Control Technology
Experimental Methods Of Coating Evaluation
• Single Frequency Measurement (0.1 Hz)EIS d C bi t T t• EIS and Cabinet Tests
• Thermal Cycling• Rapid Electrochemical Assessment of Paint
(REAP)• AC-DC-AC
Leaders in Corrosion Control Technology
• Free standing films
EIS Take Home
• EIS is a versatile technique– Non-destructive– High information content
• Running EIS is easy• EIS modeling analysis is very powerful
Simplest working model is best
Leaders in Corrosion Control Technology
– Simplest working model is best– Complex system analysis is possible– User expertise can be helpful
References for EIS• Electrochemical Impedance and Noise, R. Cottis and S. Turgoose,
NACE International, 1999. ISBN 1-57590-093-9.An excellent tutorial that is highly recommended.g y
• Electrochemical Techniques in Corrosion Engineering, 1986, NACE InternationalProceedings from a Symposium held in 1986. 36 papers. Covers the basics of the various electrochemical techniques and a wide variety of papers on the application of these techniques. Includes impedance spectroscopy.
• Electrochemical Impedance: Analysis and Interpretation, STP 1188, Edited by Scully Silverman and Kendig ASTM ISBN 0-8031-1861-9
Leaders in Corrosion Control Technology
Edited by Scully, Silverman, and Kendig, ASTM, ISBN 0 8031 1861 9.26 papers covering modeling, corrosion, inhibitors, soil, concrete, and coatings.
• EIS Primer, Gamry Instruments website, www.gamry.com
3/2/2011