ege manisa 70 cm bir carinaro 55 cm fabriano june...
TRANSCRIPT
EGE Manisa 70 cm
BIR Carinaro 55 cm
Fabriano June 2012
Presenter
Francesco Nieli
Manisa EGE key
Keys and Interfaces
Carnaro BIR key
Tiny Full interface(SQG_CL_??)
Tiny SD interface(SQG_CL_??)
New LED interface(SQG_CL_??)
Carinaro BI interface(SQG_CL_??)
Functions
2
SUPER COOL function:
Rapidly chills food placed in the fridge without exposing food already
stored to thermal excursion.
On activation of this function, the refrigerator starts a special procedurethat sends cold air to the fridge cavity, lowering the temperature to “+1°C”.
To do this, the appliance runs 3 special compressor ON cycles.
The function finishes automatically at the end of the third On cycle, after a
Time Out of 12 hours, or manually if the relevant key is pressed.
SUPER FREEZE function:
Freezes food rapidly, enabling longer storage.
The function will only terminate when the maximum 24 hours is reached;
freezer function is assured at the minimum temperature.
The Super Freeze 48 hours function and exit on reaching the temperature
have also been eliminated on Partial-Integrated and Static appliances.
N.B.: When the function is activated, the appliance runs an initial defrost
cycle if and only if at least 3 hours of Compressor ON have passed since
the last defrost.
Functions
3
Pressing the button once enables the ozone function, and the relative LED/icon will light up.
Pressing the key again while the Ozone function is on will turn off the icon on the display and stop
the function (it does not stop automatically). The OZONE function also switches off when the
appliance is turned off.
In the event of a fault or alarm, the ozone generator will continue to work as normal. The only way
it will switch off in these circumstances is when a Reset Alarm turns the appliance off.
The device is powered (not managed) by the PCB.
It runs cyclically in "4 minute ON" and "26 minute OFF" intervals.
Nominally, 10 mg/h of ozone is generated during continuous function, hence the quantity of ozone
produced in our appliances is 1.33 mg/h.
It will not be tested during the Autotest function.
It runs on a 220 V supply.
Ozone-generator:The device uses the corona discharge effect to generate
ozone.
The purpose of this function is to produce ozone to:
a) Remove odours.
b) Kill bacteria.
c) Conserve fresh food for longer, especially
fruit and vegetables.
4
ECOPLUS function
The ECOPLUS function is similar to the ECO cycle which sets temperatures of “+5°C” &
“-18°C” automatically, with the difference that ECOPLUS regulates Fridge and Freezer
temperatures across the entire regulation table.
5 seconds after regulation has been changed, the display switches off then switches back on
again when a key is pressed. The display remains off even when the door is opened.
The underlying rationale is the same hence after cold air has been requested in the fridge
cavity, before switching off the compressor, cold air is sent to the freezer cavity.
ECOPLUS DISPLAY
TINY ALL / BI CARINARO
ACTIVATIONPress and hold SF and FRZ "+" temperature keys at the same time for 6 secs with appliance ON.
DEACTIVATIONPress ON/OFF key.
All LEDs/DGTs light up for 2 secs.
ENTRY
ACTIVATIONPress and hold the SC and FRG "+" temperature keys at the same time for 6 secs with appliance ON.
DEACTIVATIONSwitch off using combination of OFF.
4 LEDs light up for 2 secs: SC, SF, first FRG regulation and final FRZ regulation
In the event of a power failure (for all User Interfaces)
5
APPLIANCE STATE Behavior during black out
First switch-on Programming/ON
Appliance OFF (switched off from key)
OFF
STANDBY Goes back to Programing/ON
FRG / FRZ TEMPERATURE
They switch back on with the settings from prior to black-out.
SUPERCOOL If it was set, it reactivates after black-out.
SUPERFREEZE If it was set, it reactivates after black-out.
HOLIDAY If it was set, it reactivates after black-out.
CLK If it was set, it reactivates after black-out.
OZONE If it was set, it reactivates after black-out.
ECOPLUS It reactivates. Creates backup if set accordingly.
6
User Interface
TINY FULL and Single Door
TINY FULL and Single Door User Interface Navigation
7
ON/OFF button:Press the On/Off button once to switch the
appliance on. On switching on, the
appliance makes a rising beep as
confirmation plus the entire User Interface
lights up for 2 seconds.
Press the On/Off key for 3 seconds to
switch off. A descending beep confirms the
appliance has switched off.
TINY FULL and Single Door User Interface Navigation
8
Stand By:If the User Interface is idle for 2 minutes,
the display and LED switch to light-
saving illumination.
Pressing any key will restore the User
Interface to normal brightness.
Opening/closing the door has no effect.
When the appliance has a FAULT or
ALARM, it will not go into STAND BY (or it
will wake up if in stand-by already).
9
Appliance On:When switched on for the first time, thefridge temperature is set to +5°C and
freezer to –18°C.
Each time it is switched on after that,
the most recent user settings are
retrieved.
When the appliance is switched on, the
Fridge and Freezer temperatures are
shown, along with any other options
set.
TINY FULL and Single Door User Interface Navigation
10
Fridge Temperature Buttons:The fridge temperature regulation range has7 levels: +2°C; +3°C; +4°C; +5°C; +6°C;
+7°C; +8°C.
The temperature value increases on
pressing the “+” key and decreases on
pressing the “-” key.
The selected temperature is shown on the
display along with the “+” sign.
The regulation has an end of scale value, i.e.
when the table minimum is reached, it will go
no further (the capacitive keypad will emit the
standard beep in response).
TINY FULL and Single Door User Interface Navigation
11
Freezer Temperature Button:The freezer temperature regulation range has9 levels: -18°C; -19°C; -20°C; -21°C;
-22°C; -23°C; -24°C; -25°C; -26°C.
The freezer temperature value increases on
pressing the “+” key and decreases on
pressing the “-” key. The user's selected
temperature is shown on the display beside
the “-” sign.
The regulation has an end of scale value, i.e.
when the table minimum is reached, it will go
no further (the capacitive keypad will emit the
standard beep in response).
TINY FULL and Single Door User Interface Navigation
TINY FULL and Single Door User Interface Navigation
12
SUPER COOL function:The Super Freeze and Super Cool functions
can be set at the same time.
Pressing the Super Cool button once enables
the function, and the relative LED/icon will
light up. The letters “SC” will appear on the
Fridge section digits.
The Super Cool function disables manually
when the relative key is pressed again, when
the appliance is switched off, or automatically
after three Compressor On cycles at atemperature of “+1°C” or 12 hours after
activation.
13
Super Freeze Function:The Super Freeze and Super Cool functions
can also be set at the same time.
Pressing the Super Freeze button once enables
the function, and the relative LED/icon will light
up. The letters “SF” will appear on the Freezer
section digits.
The Super Freeze function disables manually
when the relative key is pressed again, when
the appliance is switched off, or automatically
after 24 hours.
TINY FULL and Single Door User Interface Navigation
14
“Manisa”
NEW ENTRY LED
User Interface
“Manisa” Entry LED User Interface navigation
15
Stand By:The User Interface never goes into STAND BY when idle, although the user
interface LEDs switch off when the door is closed.
ON/OFF status:When OFF, pressing the 2 keys on the left at the same time once will switch the
appliance on.
When ON, pressing and holding the 2 keys from the left at the same time for 3
seconds will switch the appliance off.
16
Programming Status (Appliance On):When the appliance is On, the Fridge and Freezer temperatures and any other options
configured are shown.When switched on for the first time, the temperatures are set at “+4°C” & “-18°C”.
Each time it is switched on after that, the most recent user settings are retrieved.
“Manisa” Entry LED User Interface navigation
17
Refrigerator Temperature Buttons:The fridge temperature regulation range has 4 levels printed on the front: +2°C;
+4°C; +6°C; +8°C.
The temperature value increases from left to right when the far right key is pressed.
Pressing and holding will make it repeat until it reaches the end of scale.
On reaching the full scale value (or fourth level), pressing the key again will take it
back to level 1.
“Manisa” Entry LED User Interface navigation
18
Freezer Temperature Button:The freezer temperature regulation range has 4 levels printed on the front: -18°C;
-20°C; -22°C; -26°C.
The temperature value increases from left to right when the first key on the left is
pressed.
Pressing and holding will make it repeat until it reaches the end of scale.
On reaching the full scale value (or fourth level), pressing the key again will take
it back to level 1.
“Manisa” Entry LED User Interface navigation
19
SUPER COOL key:The Super Freeze and Super Cool functions can also be set at the same time.
On pressing the Super Cool key to turn the function on, the relative LED will light up and the LED
for the fridge cavity temperature set by the user will switch off.
Pressing the Freezer Temperature key while the function is enabled will generate audio and visual
feedback to signal incompatibility (3 short, fast beeps and 3 fast blinks) only on the LED for the
user-configured temperature.
The function can be ended:Automatically, after three Compressor On cycles at a temperature of “+1°C” or 12 hours
(time out) after activation.
Manually, when the relative key is pressed rapidly or when the appliance is switched off.
The LED for the function switches off and the LED for the temperature set by the user before the
function was enabled switches on again.
“Manisa” Entry LED User Interface navigation
20
Super Freeze Button:The Super Freeze and Super Cool functions can also be set at the same time.
The Super Freeze function enables when the relative key is pressed, and the associated LED will
light up. The LED for the freezer cavity temperature (user freezer regulation) switches off.
Pressing the Freezer Temperature key while the function is enabled will generate a beep and
visual feedback to indicate incompatibility (3 short, fast beeps and 3 fast blinks) only on the LED
for the user-configured temperature.
The Super Freeze function can be ended:Automatically, 24 hours after activation or when an Alarm or Fault occurs.
Manually, when the relative key is pressed again, or when the appliance is switched off.
The Super Freeze LED switches off and the LED for temperature set by the user before the
function was enabled switches on again.
“Manisa” Entry LED User Interface navigation
___ ____ ___ __________ ___ _____ ___ _____ _____ ______
______ _______
____ _______
_____ _______
_____ _______
Click to modify the font displayed
Level II
Level III
Level IV
Level V
Freezer Fan Function - Appliances: EGE
Freezer Fan is always starting at 9 Volts;
When the On time of Compressor arrives at 180 min the Freezer Fan switches to 11Volts
If the cycle stops at 11 Volts, the Fan restarts the next cicle at 11 Volts;
If the cycle is lasting less then 3 hrs, the next cycle will be at 9 Volts;
* The Fan start at minimum 8 Volts only the cycle after defrost.
11V
Compressor
Off
FZ FAN
CPS ON ≥ 3
hours
CPS ON
≤ 3hrs
CPS ON
≤ 3hrs
When CPS ON
arrive at 3hours the
fan switch to 11VWhen the last CPS
ON is less then
3hours the fan
switch to 9V
9V
22
Internal air flow - Appliances: EGE
23
Internal air flow - Appliances: EGE
24
Internal air flow - Appliances: EGE
25
Internal air flow - Appliances: EGE
26
“Carinaro” Built In
User Interface
“Carinaro” Built In User Interface Navigation
27
ON/OFF status:When the appliance is connected to the mains power supply, the "plug" LED icon
lights up; it switches off when the appliance is unplugged.
The appliance switches on when the ON/OFF key is pressed. On switching on, a
rising beep sounds.
Once on, pressing and holding the On/Off key for at least 3 seconds will switch the
appliance off; a descending beep will sound.
Stand By:The User Interface never goes into STAND BY when idle, although the user
interface LEDs switch off when the door is closed.
28
Appliance ON:When the appliance is switched on, the set Fridge and Freezer temperatures are
shown (not the actual temperatures inside the cavities) and any other options
configured.When switched on for the first time, the following temperatures are set: “+5°C” and
“–18°C”.
Each time it is switched on after that, the most recent user settings are retrieved.
“Carinaro” Built In User Interface Navigation
29
Fridge Temperature Button:The fridge temperature regulation range has 7 levels:
+2°C; +3°C; +4°C; +5°C; +6°C; +7°C; +8°C.
Temperature values increase when the “+” key is pressed and decrease when the
“-” is pressed, and are shown on the display along with the “+” sign.
The regulation has an end of scale value, i.e. when the table minimum or maximums
are reached, it is impossible to go any further.
“Carinaro” Built In User Interface Navigation
30
Freezer Temperature Button:The freezer temperature regulation range has 9 levels: -18°C; -19°C; -20°C; -21°C; -22°C; -23°C; -24°C; -25°C; -26°C.
Temperature values increase when the “+” key is pressed and decrease when the “-”
is pressed, and are shown on the freezer display along with the “-” sign.
The regulation has an end of scale value, i.e. when the table minimum or maximums
are reached, it is impossible to go any further.
“Carinaro” Built In User Interface Navigation
31
SUPER COOL function:The Super Freeze and Super Cool functions can also be set at the same time.
Pressing the Super Cool button once enables the function, and the relative LED/icon will light up. The target fridge temperature remains on the DIGITS (+1°C).
The Super Cool function disables manually when the relative key is pressed again,
when the appliance is switched off, automatically after three Compressor On cycles ata temperature of “+1°C”,12 hours (time out) after activation, or in the event of a fault
or temperature alarm (A1 or A2).
“Carinaro” Built In User Interface Navigation
32
Super Freeze Function:The Super Freeze and Super Cool functions can also be set at the same time. The
target freezer temperature to be reached remains on the DIGITS.
The Super Freeze function disables manually when the relative key is pressed, when
the appliance is OFF or automatically at the end of the set time.
“Carinaro” Built In User Interface Navigation
33
Holiday Function:Pressing the relative key activates the Holiday function. On activation, a beep sounds
and the relative icon lights up on the display.Temperatures in each of the cavities are changed to “+12°C” for the fridge and
“-18°C” for the freezer.
The function can only be disabled manually by pressing the relative key again. It will
also disable when there is a temperature alarm or in the event of a fault.
“Carinaro” Built In User Interface Navigation
34
Ozone-generator:This function cannot be activated from the User Interface.
In the fridge cavity of the appliance (at the top) there is a button to switch the function
on and off.
This appliance follows the same operating logic as explained earlier in this
presentation.
“Carinaro” Built In User Interface Navigation
___ ____ ___ __________ ___ _____ ___ _____ _____ ______
______ _______
____ _______
_____ _______
_____ _______
Click to modify the font displayed
Level II
Level III
Level IV
Level V
Freezer Fan Function - Appliances: BIR
Fz fan is always starting at 9 Volts;
If the ON Compressor is lower than 180 min, the fan works at 9 Volts;
When the Compressor time reaches 180 min, the fan switchs to 11 Volts;
If the cycle stops at 11 Volts, the Fan restarts the next cicle at 11 Volts;
If the cycle is lasting less then 3 hours, the next cycle will be at 9 Volts;
• The Fan starts at minimum 8 Volts only the cycle after defrost.
11V
Compressor
Off
FZ FAN
CPS ON ≥ 3
hours
CPS ON
≤ 3hrs
CPS ON
≤ 3hrs
When CPS ON
arrive at 3hours the
fan switch to 11VWhen the last CPS
ON is less then
3hours the fan
switch to 9V
9V
36
Internal air flow - Appliances: BIR
Fridge cavity
Freezer cavity Freezer cavity
Defrosting
Starting Forced Defrost (For Service)
38
How to start forced defrost:A forced defrost procedure has been introduced in all appliances in the ARTICA
Platform and also in these appliances; it should be used when the Evaporator
Battery needs to be defrosted and a three-hour Compressor ON hasn’t been
completed yet.
The procedure consists of the following steps:• Starting with the appliance On and the door closed, open and close the fridge
door four times consecutively. Do not leave more than 5 seconds between one
action (open / close) and the next.
• Within five seconds, open the fridge door for a fifth time.
• Keeping the fridge door open, within 5 seconds switch the appliance off (using
the On/Off button or knob, depending on the type of interface).
• Keeping the fridge door open, within 5 seconds switch the appliance back on
(using the On/Off button or knob, depending on the type of interface).
The procedure will be canceled in the following cases:• If more than 5 seconds is left between one step and the next.
• If the appliance is switched off in steps 1 and 2.
• If the fridge door is closed in steps 3 and 4.
___ ____ ___ __________ ___ _____ ___ _____ _____ ______
______ _______
____ _______
_____ _______
_____ _______
Click to modify the font displayed
Level II
Level III
Level IV
Level V
Defrost Procedure in EGE NF appliances
Start of the defrost cycle depends from:• Duration of last defrost.
• Time of fridge door opening (every 5 cumulative minutes of door open time
reduces the start of the next defrost cycle by one hour)
• Compressor ON time (minimum is 10 hours)
• Actual time between 2 defrost cycles could be in the range [minimum 10 hours
/ maximum 30 hours (48 hours only if the product is in Energy Consumption
Test)]. (Consumption Test conditions: ECO Mode + Door Closed for at
least 14 hours + Last Compressor ON less than 3 hours ago.)
Defrost cycles can be activated by some particular circumstances:• In the event of Alarms “A1” and “A2”, a defrost cycle is carried out every 2 hours.
• If the Door Open Alarm remains active for more than 30 minutes, a defrost cycle
will be performed every 2 hours until the door is closed (Alarm Reset).
• In the event of activation of the Super Freeze Function, if at least 3 cumulative
hours of Compressor ON have passed since the last defrost cycle.• If the Fridge Air Probe registers a value above +12°C for 135 consecutive minutes
(this function is not available when the Holiday Function is active).
___ ____ ___ __________ ___ _____ ___ _____ _____ ______
______ _______
____ _______
_____ _______
_____ _______
Click to modify the font displayed
Level II
Level III
Level IV
Level V
Defrost Procedure in EGE NF appliances
Description:• (A) - All loads are disabled and the defrost heating elements are switched on.• (B) - The heating elements switch off when the freezer evaporator probe reaches +17°C or after 50 minutes
(Defrost Time Out).
• (C) - As soon as the heating elements switch off, the freezer fan is activated for 5 seconds in order to deliver
warm air to the cold air inlet pipe from the freezer compartment into the fridge compartment. Everything else
remains switched off during this time.
• (D) - All the loads remain disabled for around 12 minutes to allow the water to flow into the compressor drawer.
• (E1 energy consumption test) - The compressor is switched on to cool the coil that has heated up duringdefrosting for a fixed time of 10min, the FZ fan started only when the freezer evaporator probe reaches +0°.
• (E2 out of energy consumption test) - The compressor is switched on to cool the coil that has heated upduring defrosting for a fixed time of 10min or when the freezer evaporator probe reaches 0°C, then also the FZ
fan is switched on for 1min; after this 1minute, the fan is switched off and compressor works until the evaporatorprobe reaches -25°C or fixed time 15min.
ON
OFF(A)
(B)
(C) (E1)
(D)
Heating elementsFreezer fan Damper
Compressor
(E2)
___ ____ ___ __________ ___ _____ ___ _____ _____ ______
______ _______
____ _______
_____ _______
_____ _______
Click to modify the font displayed
Level II
Level III
Level IV
Level V
Defrost Procedure in Carinaro BIR PNF appliances
Start of the defrost cycle depends from:• Duration of last defrost.
• Time of fridge door opening (every 5cumulative minutes of door open time reduces
the start of the next defrost cycle by one hour)
• Compressor ON time (minimum is 9 hours)
• Actual time between 2 defrost cycles could be in the range [minimum 10 hours /
maximum 30 hours (48hours only if the product is in EC Mode)] > (Consumption
Test conditions: ECO Mode + Door Closed for at least 14 hours + last
Compressor ON at least 3 hours ago)
Defrost cycles can be activated by some particular circumstances• In the event of Alarms “A1” and “A2”, a defrost cycle is carried out every 2 hours.
• If the Door Open Alarm remains active for more than 30 minutes, a defrost cycle will be
performed every 2 hours until the door is closed (Alarm Reset).
• In the event of activation of the Super Freeze Function, if at least 3 cumulative hours
of Compressor ON have passed since the last defrost cycle.
___ ____ ___ __________ ___ _____ ___ _____ _____ ______
______ _______
____ _______
_____ _______
_____ _______
Click to modify the font displayed
Level II
Level III
Level IV
Level V
Defrost Procedure in Carinaro BIR PNF appliances
Description• (A) - All loads are disabled and the defrost heating elements are switched on.• (B) - The heating elements switch off when the freezer evaporator probe reaches +17°C or after
50 minutes (Defrost Time Out). When the product is in Power Consumption, the treshold of thethe freezer evaporator probe to exit by this step is +1°C.
• (C) - As soon as the heating elements switch off, the freezer fan is activated for 5 seconds in order to
deliver warm air to the cold air inlet pipe from the freezer compartment into the fridge compartment.
Everything else remains switched off during this time.
• (D) - All the loads remain disabled for around 12 minutes to allow the water to flow into the
compressor drawer.
• (E) - The compressor is switched on to cool the coil that has heated up during defrosting until theFreeze Evaporator probe reaches -5°C, than for fixed time of 15min the Freeze Fan is switched ON
with compressor.
ON
OFF(A)
(B)
(C) (E)
(D)
Heating elementsFreezer fan
Compressor
Alarm
Description of Alarms (in all User Interfaces)
44
Door Open ALARMIf the fridge door is left open for longer than 2 minutes, the Door Open Alarm
will activate, a buzzer will sound and the fridge lamp will no longer remain
permanently alight but begin flashing on and off at regular intervals.
Description of Alarms (in all User Interfaces)
45
“A1” & “A2” FREEZER TEMPERATURE ALARM:There are two types of alarm as on current models: A1 (minor) and A2 (critical). Each alarm has
a display message and constant beep.
Temperature alarms are disabled for the first 24 hours of appliance operation (only the first ever 24
hours, not every time it is switched on).
To silence the beep, open and close the FRIDGE door or press the change Freezer Temperature
keys (for all UIs).
To set the alarm, switch the appliance off or press the change Freezer Temperature buttons twice
(for all UIs). The buzzer doesn't have to be silenced and reset at the same time. One can happen
some time after the other.
Super Cool and/or Super Freeze options are disable during a temperature alarm, and nothing will
happen when the relative keys are pressed. When the alarm situation has been rectified, the
target temperature set by the user will be shown again.
The Carinaro Tiny and Built In User Interfaces show the alarm, and in New Entry models the LEDs
also blink when the door is closed.
N.B.: In the event of a power failure when an alarm has occurred, if it was a temperature alarm it
will be presented immediately when the time is reset with the door open (meaning it will be shown
again after 2 minutes).
Alarme “A2”Alarme “A1”
Electronic
Troubleshooting
Autotest activation
47
The autotest function starts with the appliance off.
If there is a Last Fault in the memory, the appliance shows it immediately for 20 seconds,
after which the Autotest sequence commences.
The Last Fault only cancels at the end of the Autotest sequence. If the autotest is
interrupted, the Last Fault is presented again when the procedure is restarted.
On completion of the autotest, a long beep sounds and the appliance turns OFF again. The
Last Fault transfers to rolling visible memory only via the Cooling Doctor diagnostic tool.
AUTOTEST ACTIVATION DISPLAY
TINY ALL / BI CARINARO
ACTIVATION
Long press of the Super Freeze key for 6 seconds (or Super Cool on single door fridges).
- All LEDs light up for 2 seconds.- The Last Fault is shown (where present)
for 20 seconds.- All LEDs light up for remaining duration of
the autotest.
NEW ENTRY
ACTIVATION
Long press of Super Freeze key for 6 seconds.
- The 4 LEDs used to signal Faults light up for 2 seconds: Super Freeze, “-18” and “+8“ and the Super Cool LED.
- The Last Fault is shown (where present) for 20 seconds.
Autotest Sequence [No Frost Fridge-Freezer, EGE]
Step Duration Action Light Notes
1 5 seconds Pause OFF
2 1 second Probe check OFF
If there are no probe faults,it skips to step 3.
If there are probe faults,it skips to step 6.
3 4 seconds Pause OFF
4 125 seconds
FZ fan ON
DeFrost heating element ON
Damper open
OFF
5 120 secondsFZ fan ON
DeFrost heating element ONDamper closed
OFF Skips to step 8
6 125 secondsFZ fan ON
DeFrost heating element ONDamper open
Blinking
7 120 secondsFZ fan ON
DeFrost heating element ONDamper closed
Blinking
8 Autotest ends
Autotest Sequence [No Frost 4-door, EGE]
Step Duration Action Light Notes
1 5 seconds Pause OFF
2 1 second Probe check OFF
If there are no probe faults,it skips to step 3.
If there are probe faults,it skips to step 6.
3 4 seconds Pause OFF
4 125 seconds
FZ fan ONDeFrost heating elementON
Tab heating element ONDamper open
OFF
5 120 seconds
FZ fan ONDeFrost heating element ON
Tab heating element ONDamper closed
OFF Skips to step 8
6 125 seconds
FZ fan ONDeFrost heating element ON
Tab heating element ONDamper open
Blinking
7 120 seconds
FZ fan ONDeFrost heating element ON
Tab heating element ONDamper closed
Blinking
8 Autotest ends
Autotest Sequence [Partial No Frost Fridge-Freezer, BIR]
Step Duration Action FG light Note
1 5 seconds Pause OFF
2 1 second Probe check OFF
If the probe control is OK, it skips to step 3.
If there are probe faults (KO), it skips to step 5.
3 4 seconds Pause OFF
4 245 seconds
FZ fan ONFG fan ON
DeFrost heating element ON
ON After this test, it skips to step 6.
5 245 seconds
FZ fan ONFG fan ON
DeFrost heating element ON
Blinking
6 End of Autotest.
Autotest Sequence [Static Fridge-Freezer, BIR]
Step Duration Action FG light Note
1 5 seconds Pause OFF
2 1 second Probe check OFF
If the probe control is OK, it skips to step 3.
If there are probe faults (KO), it skips to step 5.
3 4 seconds Pause OFF
4 245 seconds FG fan ON ON After this test, it skips to step 6.
5 245 seconds FG fan ON Blinking
6 End of Autotest.
Description of Faults (Manisa New Entry)
FAULTIndication
LED 1 LED 2 LED 3
F01
F02
F04
F05
F07
F08
F09
F10
F13
F15
F16
F22
F23
F24
F25
F26
F27
KEY
On
Off
Blinking
The LED signaled by the red arrow blinks
rapidly for the entire duration of the FAULT.
See Artica Table SQG_CL_31 for the relative
Fault Table.
F
52
53
F
Fault Display
TINY User Interface:The FAULT is indicated by an “F” on the
upper digits and the fault number in “XX”
format on the lower digits.
In Single Door models
(just fridge or just freezer): The letter “F” alternates with the fault
number on the display every 2 seconds.
Fault Display
54
1 2 3
NEW ENTRY User Interface:During a FAULT, the LED below the red arrow blinks rapidly, the only meaning of
which is that there is a FAULT in the appliance.
The LED with the green arrow indicates the FAULT number.
CARINARO Built In User Interface:The FAULT is indicated by an “F” on the left-hand side digit and the fault number in
“XX” format on the right.
55
Components - VERY IMPORTANT:Electronic Appliances:In these appliances, the damper and the multiflow
polystyrene are managed with a single KIT, NOT TO BE
DISMANTLED in order to avoid any leakage of air
remaining after reassembly, which could impair appliance
function.
Components
56
Disassembly
EGE 70 cm & 4 Door
57
Disassembly
Removal of Tiny Control Panel:1. Use a slim screwdriver to remove the outer
plastic panel, being careful not to scratch the
door (we recommend using some plastic tape to
protect the door).
2. Take out the fixing screws.
3. Use a slim screwdriver to remove the Display
PCB, being careful not to scratch the door (we
recommend using some plastic tape to protect
the door).
4. Disconnect the PCB connector.
N.B.: In step 3, be careful not to break the
Display PCB (when you are removing it for a
check and not to replace it).
1
2
3
4
58
Disassembly
1
2
3
4
Replacing the Light
(dismantling light holder):1. Use a slim screwdriver to lift up the
outer cover over the light holder
screws.
2. Remove the outer cover.
3. Using a slim screwdriver to remove
the 2 screws securing the light
holder.
This will give you direct access to the
light and light holder connector, if it
needs to be replaced.
59
Disassembly of Classic Ege 70 cm and 4-Door models
Disassembly of Fridge Multiflow1. Remove the drawers and shelves from the
fridge cavity.
2. Remove the 2 screws securing the Divider in
the Fridge Cavity.
3. Pull on the Divider to take it out of the Fridge
Cavity.
4. Remove the 5 plugs covering the screws.
5. Remove the 5 screws fixing the multiflow
6. Move the multiflow forward slightly and
disconnect the damper connector.
7. Pull the multiflow right out.
8. Separate the polystyrene from the plastic
cover, taking great care not to break it
N.B.: The damper must be replaced together
with the polystyrene so that during
reassembly no surfaces are left
inadequately sealed, allowing leakage
of air and potentially impairing the
performance of the fridge cavity.
1
2
3
60
Disassembly of Classic Ege 70 cm and 4-Door models
Disassembly of Fridge Multiflow1. Remove the drawers and shelves from the
fridge cavity.
2. Remove the 2 screws securing the Divider in
the Fridge Cavity.
3. Pull on the Divider to take it out of the Fridge
Cavity.
4. Remove the 5 plugs covering the screws.
5. Remove the 5 screws fixing the multiflow
6. Move the multiflow forward slightly and
disconnect the damper connector.
7. Pull the multiflow right out.
8. Separate the polystyrene from the plastic
cover, taking great care not to break it
N.B.: The damper must be replaced together
with the polystyrene so that during
reassembly no surfaces are left
inadequately sealed, allowing leakage of
air and potentially impairing the
performance of the fridge cavity.
4
5
6
8
61
Disassembly of Freezer Multiflow:1. Remove the freezer cavity drawers
2. Remove the 6 screws fixing the multiflow.
3. Pull gently on the bottom of the multiflow to
remove it.
4. Open the connectors cover by pressing on the
fixing clips.
5. Pull the connectors out.
The whole Freezer Multiflow assembly can now
be removed.
Disassembly of Classic Ege 70 cm
1
2 3 4
5
62
Disassembly of freezer multiflow:1. Take out the drawers from the top and bottom
of the Freezer Cavity (the disassembly
procedure is similar to the latest 4-door
appliances).
2. Remove the 6 screws fixing the multiflow.
3. Pull gently on the bottom of the multiflow to
remove it.
4. Open the connectors cover by pressing on the
fixing clips.
5. Pull the connectors out.
The whole Freezer Multiflow assembly can
now be removed.
Disassembly of 4-Door Ege 70 cm models
1
3
4
5
2
63
Disassembly of freezer evaporator:1. Remove the 4 screws securing the polystyrene to the
backplate.
2. Being careful not to split the polystyrene, take it off the
backplate.
3. Remove the adhesive tape over the top part of the polystyrene.
4. Open the cover to obtain access to the fan.
N.B.: The fan and the white frame are handled as a single
replacement unit. THEY DO NOT NEED TO BE
DISMANTLED!!!
1
Disassembly/Opening EGE 70 & 4D Freezer Multiflow
3
4
64
Disassembly
Carinaro Built In
65
Removing the Fan1. Remove the 2 plugs covering
the screws.
2. Remove the 2 screws securing
the fan.
3. Unplug the fan from its power
supply.
1
Disassembly of CARINARO Built In Appliances:
3
2
66
Disassembly of CARINARO Built In Appliances:
Disassembly of
Ozone Generator:1. Remove the 2 screws securing
the ozone generator.
2. Unplug the ozone generator
from its power supply.
12
Important:Don't forget that the ozone
generator is a single unit and must
be replaced as a whole.
67
1
Disassembly of CARINARO Built In Appliances:
Disassembly of Freezer Cavity:1. Remove the lower drawer.
2. Unscrew the 4 screws securing the door to
the upper compartment of the freezer
cavity.
3. Take off the door and the grille.
4. Unscrew the 3 screws on the front panel of
the freezer cavity.
5. Unscrew the remaining 2 screws securing
the evaporator cover.
6. Open the evaporator area.
7. Disconnect the fan/heating element
connector.
N.B.: All components will now be accessible.
2
68
3
Disassembly of CARINARO Built In Appliances:
4
Disassembly of Freezer Cavity:1. Remove the lower drawer.
2. Unscrew the 4 screws securing the door
to the upper compartment of the freezer
cavity.
3. Take off the door and the grille.
4. Unscrew the 3 screws on the front panel
of the freezer cavity.
5. Unscrew the remaining 2 screws securing
the evaporator cover.
6. Open the evaporator area.
7. Disconnect the fan/heating element
connector.
N.B.: All components will now be accessible.
5
69
Disassembly of CARINARO Built In Appliances:
Disassembly of Freezer Cavity:1. Remove the lower drawer.
2. Unscrew the 4 screws securing the door
to the upper compartment of the freezer
cavity.
3. Take off the door and the grille.
4. Unscrew the 3 screws on the front panel
of the freezer cavity.
5. Unscrew the remaining 2 screws securing
the evaporator cover.
6. Open the evaporator area.
7. Disconnect the fan/heating element
connector.
N.B.: All components will now be accessible.