efficiency & combustion controls by john devine€¦ · blowdown losses 3% 100psi 338of steam...

19
Energy Efficiency & Combustion Controls by John Devine

Upload: others

Post on 05-Oct-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

Energy Efficiency & Combustion

Controls by

John Devine

Page 2: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

“Minimum running costs are achieved by running boilers at high thermal efficiency”

Energy Savings

Page 3: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

• Boiler efficiency can be increased by 1% for each 15% reduction in excess air or 40o F reduction in stack gas temperature.

Energy Savings

Page 4: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

Blowdown Losses 3%

100PSI 338oF Steam 8532 lbs/hr

383oF Flue Gas Losses 18%

Feed Water 60oF

Efficiency 75%

Other Losses 2%

Radiation Losses 2%

Typical Losses

Typical Boiler

Page 5: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

The Golden Numbers

• Parallel Positioning - open loop – 3-5%

• O2 Trim closed loop - 1 - 2%

• Variable Speed Drive - 40% electrical, 0.5% turndown

• Lead Lag Sequencing - 1 - 3%

Page 6: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

Single Point Positioning

Page 7: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

Parallel Positioning

Page 8: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

Two CB Hot Water Boilers

Page 9: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

New Panel Insert

Page 10: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

Air & Fuel Servos

Page 11: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

VFD

Page 12: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

• Increased Turndown: 1.0% (The independent light off position and use of VFD both provide a real opportunity to increase the possible turndown on the boiler). (Increasing turndown has a marked impact on boiler cycling).

Savings Broken Down

Page 13: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

O2 Probe

Page 14: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

• O2 Trim: 1 -2 % (Compensates for changes in temperature, barometric conditions, air density, fuel pressure etc that can affect combustion repeatability)

Savings Broken Down

Page 15: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

* WEISHAUPT Germany

Page 16: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

* WEISHAUPT Germany

Page 17: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

Two 600 HP Low Pressure Steam Boilers

Page 18: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

Four Dual Fuel Burners

Page 19: Efficiency & Combustion Controls by John Devine€¦ · Blowdown Losses 3% 100PSI 338oF Steam 8532 lbs/hr . 383oF Flue Gas Losses 18% Feed Water 60oF Efficiency 75% Other Losses 2%

Boston School’s Natural Gas, VFD, O2 Trim