effect on flux from target z-position smearing · simulation parameters g4lbne with...
TRANSCRIPT
![Page 1: Effect on flux from target z-position smearing · Simulation Parameters g4lbne with OptimizedEngineedredNov2017.mac 2*10^6 protons @ 120 GeV Graphite target 2.2 m long 3](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb9767bcba93c2dab27f146/html5/thumbnails/1.jpg)
Effect on flux from target z-position smearing
Timur BeremkulovBIWG meeting 07/11/2019
![Page 2: Effect on flux from target z-position smearing · Simulation Parameters g4lbne with OptimizedEngineedredNov2017.mac 2*10^6 protons @ 120 GeV Graphite target 2.2 m long 3](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb9767bcba93c2dab27f146/html5/thumbnails/2.jpg)
MotivationProton beam
Graphite target
2
Pions, kaons Neutrinos
● To measure the oscillation angle with desired precision flux needs to be constrained within 1-2%
● Need to know upper bound on z-position measurement precision for NA-61/SHINE
![Page 3: Effect on flux from target z-position smearing · Simulation Parameters g4lbne with OptimizedEngineedredNov2017.mac 2*10^6 protons @ 120 GeV Graphite target 2.2 m long 3](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb9767bcba93c2dab27f146/html5/thumbnails/3.jpg)
Simulation Parameters
● g4lbne with OptimizedEngineedredNov2017.mac● 2*10^6 protons @ 120 GeV● Graphite target 2.2 m long
3
![Page 4: Effect on flux from target z-position smearing · Simulation Parameters g4lbne with OptimizedEngineedredNov2017.mac 2*10^6 protons @ 120 GeV Graphite target 2.2 m long 3](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb9767bcba93c2dab27f146/html5/thumbnails/4.jpg)
4
Nominal NuMu flux at far detector
![Page 5: Effect on flux from target z-position smearing · Simulation Parameters g4lbne with OptimizedEngineedredNov2017.mac 2*10^6 protons @ 120 GeV Graphite target 2.2 m long 3](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb9767bcba93c2dab27f146/html5/thumbnails/5.jpg)
5
![Page 6: Effect on flux from target z-position smearing · Simulation Parameters g4lbne with OptimizedEngineedredNov2017.mac 2*10^6 protons @ 120 GeV Graphite target 2.2 m long 3](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb9767bcba93c2dab27f146/html5/thumbnails/6.jpg)
● Get info about particles that exit the target● Scramble the z-position of particles● Feed them back into the simulation
● Two ways how scrambling was done:○ Gaussian smearing: Z_new = gaus(Z_old, sigma)○ Smearing within bins: break 2.2 m into N-1 bins + 1
downstream bin, if z_old is in bin M => Z_new = uniform(length of bin M)
6
![Page 7: Effect on flux from target z-position smearing · Simulation Parameters g4lbne with OptimizedEngineedredNov2017.mac 2*10^6 protons @ 120 GeV Graphite target 2.2 m long 3](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb9767bcba93c2dab27f146/html5/thumbnails/7.jpg)
Example of Target Exit Z position plot, with gaussian smearing, sigma = 50cm
7
![Page 8: Effect on flux from target z-position smearing · Simulation Parameters g4lbne with OptimizedEngineedredNov2017.mac 2*10^6 protons @ 120 GeV Graphite target 2.2 m long 3](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb9767bcba93c2dab27f146/html5/thumbnails/8.jpg)
8
Example of Target Exit Z position plot, with gaussian smearing, sigma = 5cm
![Page 9: Effect on flux from target z-position smearing · Simulation Parameters g4lbne with OptimizedEngineedredNov2017.mac 2*10^6 protons @ 120 GeV Graphite target 2.2 m long 3](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb9767bcba93c2dab27f146/html5/thumbnails/9.jpg)
Relative difference in flux for gaussian smearing
9
(Flux_before_smearing - Flux_after_smearing)/Flux_before_smearing
Energy, GeV
![Page 10: Effect on flux from target z-position smearing · Simulation Parameters g4lbne with OptimizedEngineedredNov2017.mac 2*10^6 protons @ 120 GeV Graphite target 2.2 m long 3](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb9767bcba93c2dab27f146/html5/thumbnails/10.jpg)
Example of Target Exit Z position plot, with gaussian smearing, N_bins = 5
10
![Page 11: Effect on flux from target z-position smearing · Simulation Parameters g4lbne with OptimizedEngineedredNov2017.mac 2*10^6 protons @ 120 GeV Graphite target 2.2 m long 3](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb9767bcba93c2dab27f146/html5/thumbnails/11.jpg)
11
Relative difference in flux for smearing within bins
Energy, GeV
![Page 12: Effect on flux from target z-position smearing · Simulation Parameters g4lbne with OptimizedEngineedredNov2017.mac 2*10^6 protons @ 120 GeV Graphite target 2.2 m long 3](https://reader035.vdocuments.us/reader035/viewer/2022070920/5fb9767bcba93c2dab27f146/html5/thumbnails/12.jpg)
Summary
● Effect of gaussian smearing and smearing within bins on NuMu flux at far detector were studied.
● Both methods show that z-position should be known within 10 cm.
12