ef cient - sid harvey'sorders.sidharvey.com/images/specs/hdxxhdxxx.pdf · water unit heater...

3
HOT DAWG ® POWER-EXHAUSTED, GAS-FIRED UNIT HEATER (MODEL HD) Hush-puppy quiet operation (see table) Right or left hand controls available on all 30-75 units. Gas, electrical and flue connections can be changed by simply flipping the Hot Dawg over Uses natural or propane gas Lightweight, easily installs 1” from ceiling with only two angle brackets (included on sizes 30-75, accessory for 100, 125) Full 10-year warranty on heat exchanger Standard power exhaust simplifies side-wall or roof venting with small-diameter vent pipe Permanently-lubricated motor for trouble-free dependability Controls can be either single or two-stage, direct spark ignition, 100% shut-off with continuous retry Low-profile design and neutral color to blend in with decor Also available with a blower (model HDB). Contact Modine for further information HOT DAWG ® H2O LOW PROFILE HOT WATER UNIT HEATER (MODEL HHD) No external moving parts - twin centrifugal blowers keep all moving parts inside the cabinet Mounting flexibility (parallel, perpendicular or recessed between joists) allows for horizontal or vertical air delivery Low-profile design Available in hammertone beige Constructed of heavy gauge steel for clean appearance and maximum headroom Includes two mounting brackets with vibration isolators to reduce noise and vibration Internal coil can handle water pressures up to 150 PSI and temperatures up to 200° F 2 Hot Dawg Applications Model Btu/Hr Input Typical Application HD/HDS 30 30,000 1 to 1-1/2 Car Garage HD/HDS 45 45,000 2 to 2-1/2 Car Garage HD/HDS 60 60,000 3 to 3-1/2 Car Garage HD/HDS 75, 100, 125 75,000-125,000 Large Garage *Sizing data for sample only. Consult a qualified installer for the actual requirements for your building. Model HD/HDS Sound Pressure Level (dBA) 1 Model Size Modine Competitor 2 5 ft. 5 ft. 30 53 59 45 57 59 60 59 59 75 58 69 1. Measured at distance from unit shown. 2. Competitor published data. Hot Dawg H 2 0 Applications Model Sizes Airflow (CFM) GPM 140° F BTU/hr 180° F BTU/hr Application HHD 30 405 405 2 4 20,600 24,200 30,900 36,300 1 to 2 car garage HHD 45 (high speed) 710 710 2 4 29,900 35,100 44,800 52,700 2 to 3 car garage HHD 45 (low speed) 425 425 2 4 20,700 24,400 31,100 36,600 2 to 3 car garage

Upload: others

Post on 31-Jan-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ef cient - Sid Harvey'sorders.sidharvey.com/IMAGES/specs/hdxxhdxxx.pdf · WATER UNIT HEATER (MODEL HHD) s No external moving parts - twin centrifugal blowers keep all moving parts

HOT DAWG® SEPARATED COMBUSTION GAS-FIRED UNIT HEATER (MODEL HDS) Same features as HD, with these added benefits:

• Draws combustion air from outside the work space, ensuring the unit always has plenty of fresh, clean air to breathe

• The fresh air supply reduces common concerns about dusty, dirty or humid applications, providing greater durability and reduced maintenance

• Factory assembled, certified separated combustion saves installation time

HOT DAWG® POWER-EXHAUSTED, GAS-FIRED UNIT HEATER (MODEL HD)

• Hush-puppy quiet operation (see table)

• Right or left hand controls available on all 30-75 units. Gas, electrical and flue connections can be changed by simply flipping the Hot Dawg over

• Uses natural or propane gas

• Lightweight, easily installs 1” from ceiling with only two angle brackets (included on sizes 30-75, accessory for 100, 125)

• Full 10-year warranty on heat exchanger

• Standard power exhaust simplifies side-wall or roof venting with small-diameter vent pipe

• Permanently-lubricated motor for trouble-free dependability

• Controls can be either single or two-stage, direct spark ignition, 100% shut-off with continuous retry

• Low-profile design and neutral color to blend in with decor

• Also available with a blower (model HDB). Contact Modine for further information

HOT DAWG® H2O LOW PROFILE HOT WATER UNIT HEATER (MODEL HHD)

• No external moving parts - twin centrifugal blowers keep all moving parts inside the cabinet

• Mounting flexibility (parallel, perpendicular or recessed between joists) allows for horizontal or vertical air delivery

• Low-profile design

• Available in hammertone beige

• Constructed of heavy gauge steel for clean appearance and maximum headroom

• Includes two mounting brackets with vibration isolators to reduce noise and vibration

• Internal coil can handle water pressures up to 150 PSI and temperatures up to 200° F

2

EFFINITY 93® CONDENSING UNIT HEATER (MODEL PTC)Looking for the most efficient unit?All model sizes operate at 93% efficiency, making it the most efficient gas-fired, condensing unit heater in North America

Features Modine’s high-grade stainless steel Conservicore® technology secondary heat exchanger

All sizes are separated combustion

The standard Contractor Convenience Package allows for easy connectivity and troubleshooting with a factory mounted disconnect switch, external operating lights and convienience outlet

A minimum 15% decrease in C02 versus other gas-fired heaters and minimum 17% gas savings (up to 40%)

A smart investment and respectable ROI with valuable state utility rebates available

Performance Data - Model PTC

1. Ratings shown are for elevations up to 2,000 ft. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet about sea level. (In Canada see rating plate.) Reduction of ratings requires use of high altitude kit.

2. Data taken at 65ºF ambient and unit fired at full-rated input. Mounting height as measured from bottom of unit, and without deflector hoods. ˆ

* Requires a 40 degree ambient temperature at all times and access to a drain for condensate

Model size 55 65 85 110

Btu/Hr Input1 ➀ 55,000 65,000 85,000 110,000

Btu/Hr Output1 51,150 60,450 79,050 102,300

Condensate Production (Gal./Hr.) 0.3 0.4 0.5 0.7

Entering Airflow (CFM) @ 70°F2 1,097 1,141 1,650 1,750

Outlet Velocity (FPM)2 618 650 619 668

Air Temp. Rise (°F) 43 49 44 54

Max. Mounting Height (Ft.)2 12 12 13 13

Heat Throw (Ft.) @ Max. Mtg Ht 43 43 48 46

93% Efficient

Hot Dawg ApplicationsModel Btu/Hr Input Typical Application

HD/HDS 30 30,000 1 to 1-1/2 Car Garage

HD/HDS 45 45,000 2 to 2-1/2 Car Garage

HD/HDS 60 60,000 3 to 3-1/2 Car Garage

HD/HDS 75, 100, 125 75,000-125,000 Large Garage

*Sizing data for sample only. Consult a qualified installer for the actual requirements for your building.

Model HD/HDS Sound Pressure Level (dBA)1

ModelSize

Modine Competitor2

5 ft. 5 ft.

30 53 59

45 57 59

60 59 59

75 58 69

1. Measured at distance from unit shown. 2. Competitor published data.

Hot Dawg H20 Applications

Model Sizes Airflow (CFM) GPM 140° F

BTU/hr180° F BTU/hr Application

HHD 30 405 405

24

20,600 24,200

30,90036,300 1 to 2 car garage

HHD 45 (high speed) 710 710

24

29,900 35,100

44,80052,700 2 to 3 car garage

HHD 45 (low speed) 425 425

24

20,700 24,400

31,10036,600 2 to 3 car garage

Performance Data - Model HD/HDSModel Size 30 45 60 75 100 125

Btu/Hr Input1 30,000 45,000 60,000 75,000 100,000 125,000

Btu/Hr Output1 24,000 36,000 48,000 60,000 80,000 100,000

Entering Airflow (CFM)2 505 720 990 1,160 1,490 1,980

Outlet Velocity 2 523 749 653 769 565 747

Air Temp. Rise (ºF) 44 46 45 48 50 47

Mounting Height (Max ft.) 2 10 10 12 14 12 16

Heat Throw (ft.) 25 27 36 38 42 56

331464 6-114.8.indd 2 6/18/13 10:28 PM

MMARTIN
Typewritten Text
STOCKED IN CDC: HD (NAT GAS) MODELS HD30, HD45, HD75, HD100, HD125 HD (LP) MODELS HD30LP, HD45LP, HD75LP, HD125LP
MMARTIN
Typewritten Text
MMARTIN
Typewritten Text
MMARTIN
Typewritten Text
Page 2: Ef cient - Sid Harvey'sorders.sidharvey.com/IMAGES/specs/hdxxhdxxx.pdf · WATER UNIT HEATER (MODEL HHD) s No external moving parts - twin centrifugal blowers keep all moving parts

TAKE THE CHILL OUT OF YOUR GARAGE OR WORKSPACE

WITH A HOT DAWG.®

©2013 Modine Manufacturing Co. 6-114.8

Dimensions (inches) - Model HD/HDSModel Size 30 45 60 75 100/125

A 26.8 26.8 26.8 26.8 35.5

B 12.2 12.2 18.0 18.0 20.5

C 22 22 25 25 31.0

Gas Connection 1/2 1/2 1/2 1/2 1/2

Vent Connector Size (in.) 3 3 3/4* 3/4* 4

Approx. Shipping Weight (lbs.) 55 60 80 85 125

* 3” for Model HD, 4” for Model HDS

RESIDENTIALLY-CERTIFIED, GAS-FIRED UNIT HEATER SPECIFICATIONS

Follow us on Twitter @ModineHVAC

Modine Manufacturing Company1500 DeKoven AvenueRacine, Wisconsin 53403-2552 1.800.828.HEATwww.ModineHVAC.com

1” - angle, mounting brackets are slotted to accommodate joists on 16” or 24” centerlines.

Top and Bottom 1" 1" Access Side 1" 18" Non-Access Side 1" 1" Rear 18" 18" Vent Connector 4" 4"

30 45 60 75 100 12530,000 45,000 60,000 75,000 100,000 125,00024,000 36,000 48,000 60,000 80,000 100,000

505 720 990 1,160 1,490 1,980523 749 653 769 565 747

44 46 45 48 50 47 10 10 12 14 12 16 25 27 36 38 42 56 1/15 1/15 1/12 1/12 1/12 1/8 1,550 1,550 1,625 1,625 1,050 1,550 S.P. S.P. P.S.C. P.S.C. S.P. P.S.C. 2.4 2.4 1.2 1.2 2.7 2.2 3.7 3.7 2.5 2.5 4.7 4.2

* 3" for Model HD, 4" for Model HDS

Model SizeBtu/Hr Input

Btu/Hr OutputEntering Airflow (CFM)

Outlet VelocityAir Temp. Rise (°F)

Mounting Height (Max ft.)Heat Throw (ft.)

Unit Total Amps

3/4* 3/4* 4Vent Connector Size (in.)

Performance

HorsepowerRPMTypeAmps

MotorData

Mounting

ClearancesUnit Side Clearance To

Combustible MaterialsRecommended

Service Clearance

SIZES30-75

SIZES100/125

(ACCESSORY)

.00

1.10

3.10

5.10

7.10

9.10

17.1

0

19.1

0

21.1

0

23.1

0

25.1

026

.20

.00

1.50

3.50

5.50

7.50

9.50

11.5

0

13.5

0

21.5

0

23.5

0

25.5

0

27.5

0

29.5

0

31.5

0

33.5

035

.00

30 45 60 75 100/125 26.8 26.8 26.8 26.8 35.5 12.2 12.2 18.0 18.0 20.5 16.5 16.5 16.5 16.5 22.0 14.9 14.9 14.9 14.9 22.5 10.1 10.1 15.9 15.9 18.4 7.25 7.25 10.75 10.75 14.0 18.5 18.5 18.5 18.5 24.0 7.6 7.6 7.835 7.835 8.4 1/2 1/2 1/2 1/2 1/2 34.5 34.5 34.5 34.5 43.0 22 22 25 25 31.0 2.74 2.74 3.15 3.15 3.87 3.19 3.19 5.55 5.55 10.73

10 10 14 14 18.0 55 60 80 85 125

Model SizeABCDEFGH

Gas ConnectionIJK (HDS only)L (HDS only)

Fan DiameterApprox. Shipping Weight (lbs.)

Dimensions (inches)

Control Options Control Description Control Service Thermostat Type of Model Code No. Voltage Voltage Gas Size

Single-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry 11 115V 24V natural 30-125- Utilizes a single-stage combination gas control with ignition control. Gas is lit with a direct spark igniter on call for heat. 21 115V

24V

propane

30-125

Two-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry 12 115V 24V natural 75-125- Utilizes a two-stage combination gas control with built-in ignition control. Firing rate is 100% and 50% of full rated input. Gas is lit with a direct spark 22 115V 24V propane

75-125igniter on call for heat.

COMBUSTION AIRLOUVERS (HD ONLY)

3 3

3 3

4 4 4Combustion Air Inlet ConnectorSize (Model HDS only) (in.)

B

A

CC (APPROX.)

1” - angle, mounting brackets are slotted to accommodate joists on 16” or 24” centerlines.

Top and Bottom 1" 1" Access Side 1" 18" Non-Access Side 1" 1" Rear 18" 18" Vent Connector 4" 4"

30 45 60 75 100 12530,000 45,000 60,000 75,000 100,000 125,00024,000 36,000 48,000 60,000 80,000 100,000

505 720 990 1,160 1,490 1,980523 749 653 769 565 747

44 46 45 48 50 47 10 10 12 14 12 16 25 27 36 38 42 56 1/15 1/15 1/12 1/12 1/12 1/8 1,550 1,550 1,625 1,625 1,050 1,550 S.P. S.P. P.S.C. P.S.C. S.P. P.S.C. 2.4 2.4 1.2 1.2 2.7 2.2 3.7 3.7 2.5 2.5 4.7 4.2

* 3" for Model HD, 4" for Model HDS

Model SizeBtu/Hr Input

Btu/Hr OutputEntering Airflow (CFM)

Outlet VelocityAir Temp. Rise (°F)

Mounting Height (Max ft.)Heat Throw (ft.)

Unit Total Amps

3/4* 3/4* 4Vent Connector Size (in.)

Performance

HorsepowerRPMTypeAmps

MotorData

Mounting

ClearancesUnit Side Clearance To

Combustible MaterialsRecommended

Service Clearance

SIZES30-75

SIZES100/125

(ACCESSORY)

.00

1.10

3.10

5.10

7.10

9.10

17.1

0

19.1

0

21.1

0

23.1

0

25.1

026

.20

.00

1.50

3.50

5.50

7.50

9.50

11.5

0

13.5

0

21.5

0

23.5

0

25.5

0

27.5

0

29.5

0

31.5

0

33.5

035

.00

30 45 60 75 100/125 26.8 26.8 26.8 26.8 35.5 12.2 12.2 18.0 18.0 20.5 16.5 16.5 16.5 16.5 22.0 14.9 14.9 14.9 14.9 22.5 10.1 10.1 15.9 15.9 18.4 7.25 7.25 10.75 10.75 14.0 18.5 18.5 18.5 18.5 24.0 7.6 7.6 7.835 7.835 8.4 1/2 1/2 1/2 1/2 1/2 34.5 34.5 34.5 34.5 43.0 22 22 25 25 31.0 2.74 2.74 3.15 3.15 3.87 3.19 3.19 5.55 5.55 10.73

10 10 14 14 18.0 55 60 80 85 125

Model SizeABCDEFGH

Gas ConnectionIJK (HDS only)L (HDS only)

Fan DiameterApprox. Shipping Weight (lbs.)

Dimensions (inches)

Control Options Control Description Control Service Thermostat Type of Model Code No. Voltage Voltage Gas Size

Single-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry 11 115V 24V natural 30-125- Utilizes a single-stage combination gas control with ignition control. Gas is lit with a direct spark igniter on call for heat. 21 115V

24V

propane

30-125

Two-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry 12 115V 24V natural 75-125- Utilizes a two-stage combination gas control with built-in ignition control. Firing rate is 100% and 50% of full rated input. Gas is lit with a direct spark 22 115V 24V propane

75-125igniter on call for heat.

COMBUSTION AIRLOUVERS (HD ONLY)

3 3

3 3

4 4 4Combustion Air Inlet ConnectorSize (Model HDS only) (in.)

B

A

CC (APPROX.)

To find out where to buy a Hot Dawg, visit www.ModineHVAC.com/HotDawg

For Hot Dawg H2O specifications, visit www.ModineHVAC.com/HotDawg

2

Horizontal air delivery; perpendicular to joists

Vertical air delivery; recessed between joists

Horizontal air delivery; parallel to joists

Hot Dawg H2O Mounting Flexibility

ADJUSTABLELOUVERS

(4) 3/8"-16 MTG HOLES

CONDENSATE DRAIN3/4" PVC

GASCONN.

COMBUSTION AIR INLET

VENTOUTLET

FAN

KNOCKOUTS FOR SUPPLY POWER WIRING

CONDUIT ENTRANCE

ACCESSPANEL

B

C

R (APPROX.) D (OPENING)

E(OPENING)

I

J

KL

H

F

G

M

A Q (MINIMUM DISTANCE TO WALL)

3.56 14.90 N P

CONDENSATE DRAIN3/4" PVC

GASCONN.

COMBUSTION AIR INLET

VENTOUTLET

FAN

KNOCKOUTS FOR SUPPLY POWER WIRING

CONDUIT ENTRANCE

ACCESSPANEL

B

H (APPROX.)

A

C (APPROX.)

B

AADJUSTABLE

LOUVERS(4) 3/8"-16 MTG HOLES

CONDENSATE DRAIN3/4" PVC

GASCONN.

COMBUSTION AIR INLET

VENTOUTLET

FAN

KNOCKOUTS FOR SUPPLY POWER WIRING

CONDUIT ENTRANCE

ACCESSPANEL

B

C

R (APPROX.) D (OPENING)

E(OPENING)

I

J

KL

H

F

G

M

A Q (MINIMUM DISTANCE TO WALL)

3.56 14.90 N P

CONDENSATE DRAIN3/4" PVC

GASCONN.

COMBUSTION AIR INLET

VENTOUTLET

FAN

KNOCKOUTS FOR SUPPLY POWER WIRING

CONDUIT ENTRANCE

ACCESSPANEL

B

H (APPROX.)

A

C (APPROX.)

B

A

Model size 55 65 85 110

A 29.80 29.80 35.53 35.53

B 18.13 18.13 20.31 20.31

C 28.19 28.19 33.83 33.83

Combustion Air Inlet Pipe

3 3 3 3

Vent Outlet Pipe 3 3 3 3

Gas Connection 1/2 1/2 1/2 1/2

Approx. Shipping Weight (lbs.)

93 103 125 128

Dimensions (inches) - Model PTC1➀

➀ 1. Do not use propeller units with duct work.

Clearances for Residentially-Certified Unit Heaters

Unit Side Clearance To Combustible Materials

Recommended Service Clearance

Top and Bottom 1” 1”

Access Side 1” 18”

Non-Access Side 1” 1”/18”1

Rear 18” 18”

Vent Connector 4”/6” 1 4”/6”1

➀ 1. For high-efficiency unit only (Model PTC)

For more information on the Effinity93, visit www.ModineHVAC.com/Effinity93

331464 6-114.8.indd 1 6/18/13 10:27 PM