edge - pinnacle architectural lighting 2013 website/spec... · photometrics edge ex3b_a individual...

2
EX3B- EX3B- Edge EX 3 Bidirectional with Straight Lamps Sample Catalog #: EX3B-A-O-T5-2-1-4-AC48G1-120-1C-W A- O- A- Satine Lens O- Open Individual Units 4- 8- 1- 2- 1- 4’ 8’ 1 Lamp 2 Lamp 1 1 Lamp __- __- ____- CONSTRUCTION 6063-T5 Extruded aluminum housing. Highly reflective die-formed white painted aluminum reflector, .125” diffuse snap-in acrylic lens with matte finish, removable for lamp replacement. LABELS UL and cUL Listed, approved for dry/damp location unless otherwise noted. LUMINAIRE SPECIFICATION Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions. Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2015 Pinnacle Architectural Lighting® June 2015 EX3BA Project Name Type Catalog Number Date 1C- 2C- 1D- 2D- 1B- 2B- 1E- 2E- Single Circuit Dual Circuit 10 Single Circuit Dimming 7 Dual Circuit Dimming 7,10 Single Circuit with Battery Pack 6,7,9 Dual Circuit with Battery Pack 6,7,9,10 Single Circuit Emergency 7 Dual Circuit Emergency 7,10 120- 277- 347- UNV- 120 V 277 V 347 V UNV 6 (120-277) Matte White Metallic Silver 11 Textured Black 11 Bronze 11 Custom Color 11 W- S- BL- BR- CC- __’- ______- __- __- __- ___- ® Continuous Runs xx’- Specify nominal overall row length in 4’ increments Dust Guard Specular Reflector Fixed MR16 Halogen 8 Fixed MR16 LED 8 Custom Color Canopy 11 DG- SR- MRF- LMRF- CC-C- T5- T5HO- T8- T5 T5HO T8 DIRECT INDIRECT LAMP TYPE LAMP UP HOUSING LAMPS DOWN LENGTH MOUNTING VOLTAGE CIRCUITING FINISH OPTIONS T5, T5HO, & T8 Direct and Indirect Linear with Straight Lamp / Satine Lens EDGE E V O L U T I O N 1 No T8 available. 2 Standard 48” adjustable aircraft cable. Consult factory for additional lengths. Single Aircraft Cable mounts 4’ and 8’ on center. Mount locations are not adjustable. 3 Consult factory for tegular edged tiles. 4 Replaces standard 2” canopy. 5 Standard 48” adjustable Y-cable mount provided. Consult factory for additional lengths. Moveable Aircraft Cable mount allows for flexible mounting loca- tions. Maximum mounting locations are 12” from end of 4’ fixture and 18” from end of 8’ fixture. 6 347V and UNV not available with battery pack and MR16. 7 Some Edge configurations will not accommodate all electrical options. Consult factory. 8 Consult factory for configurations using MR16 units. 120 volt only available. 9 Integral battery packs with remote test switch are provided with 1B and 2B options on 2T5/2T5HO fixtures. 10 Dual circuit = top and bottom lamps are on separate circuits. 11 If canopy is to match fixture housing, must specify in options section with CC-C. if not specified, canopy will be standard matte white. MOUNTING Aircraft cable, wall and surface mount available. Select from 2 aircraft cable options. Select the straight aircraft cable that mounts on 4’-0” and 8’-0” centers or the moveable adjustable Y-cable mount. The Y-Cable design allows for adjustable mounting locations. (See installation instructions for MR16 mounting detail). Aircraft Cable supplied with 5” power and 2” non-power canopies. Refer to installation instructions for appropriate ceiling detail. Canopies are painted white unless otherwise specified. AC48G1- AC48G9- AC48GS- AC48JB- AC48ST- AC5__G_- AC5__JB- SQ48G_- SQ48JB- 1” T-Bar 3 9/16” T-Bar 3 Slotted T-Bar 3 Junction Box Structure 5” Non-Power Canopy 4 5” Non-Power Canopy 4 5” Square Canopy 4 5” Square Canopy 4 Single Aircraft Cable 2 Wall WA- Wall Mount MAC48G1- MAC48G9- MAC48GS- MAC48JB- MAC48ST- MAC5__G_- MAC5__JB- MSQ48G_- MSQ48JB- 1” T-Bar 3 9/16” T-Bar 3 Slotted T-Bar 3 Junction Box Structure 5” Non-Power Canopy 4 5” Non-Power Canopy 4 5” Square Canopy 4 5” Square Canopy 4 Moveable Aircraft Cable 5 MR16 ELECTRICAL T5, T5HO: Standard programmed start UL listed Class P, T5 electronic, sound rated A, thermally protected, high power factor ballasts less than 10% THD, universal voltage (120-277) with 50/60Hz operation. T8: Standard instant start UL listed Class P, T8 electronic, Sound Rated A, thermally protected, high power factor ballasts less than 10% THD, universal voltage (120-277). Through wiring with quick connects standard. Standard single circuit. Integral battery packs with remote test switch are provided with 1B and 2B options on 2T5/2T5HO fixtures. Each ballast pro- vided with disconnects to meet luminaire disconnect code requirement. 5-3/8” 3-1/2” (1) or (2) Straight Lamps See Straight Lamp Guide for row configuration, wattage and number of lamps per run. 2T5/T5HO 1T5/T5HO 1T8 FINISH Standard powder-coat textured white, metallic silver, textured black or bronze painted finish, consult factory for chip of standard paint finishes. Pendants and canopies painted white unless specified differently in the options section of the part number. Contact factory for additional ustom color and finish options.

Upload: nguyendiep

Post on 30-Jun-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

EX3B-

EX3B- Edge EX 3 Bidirectional with Straight Lamps

Sample Catalog #: EX3B-A-O-T5-2-1-4-AC48G1-120-1C-W

A- O-

A- Satine Lens

O- Open

Individual Units4-8-

1-2-

1-

4’8’

1 Lamp2 Lamp1

1 Lamp

__- __-____-

CONSTRUCTION 6063-T5 Extruded aluminum housing. Highly reflective die-formed white painted aluminum reflector, .125” diffuse snap-in acrylic lens with matte finish, removable for lamp replacement.

LABELS UL and cUL Listed, approved for dry/damp location unless otherwise noted.

L U M I N A I R E S P E C I F I C A T I O N

Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.

Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com© 2015 Pinnacle Architectural Lighting® June 2015

EX3BAProject Name

TypeCatalog Number

Date

1C-2C-1D-2D-1B-2B-1E-2E-

Single CircuitDual Circuit10

Single Circuit Dimming7

Dual Circuit Dimming7,10

Single Circuit with Battery Pack6,7,9

Dual Circuit with Battery Pack6,7,9,10

Single Circuit Emergency7

Dual Circuit Emergency7,10

120-277-347-UNV-

120 V277 V347 VUNV6

(120-277)

Matte WhiteMetallic Silver11

Textured Black11

Bronze11

Custom Color11

W-S-BL-BR-CC-

__’- ______- __- __- __-___-

®

®

®

Continuous Runsxx’- Specify nominal

overall row length in 4’ increments

Dust GuardSpecular ReflectorFixed MR16 Halogen8

Fixed MR16 LED8

Custom Color Canopy11

DG-SR-MRF-LMRF-CC-C-

T5-T5HO-T8-

T5T5HOT8

YEARWARRANTY

ConvertibleLED

ConvertibleLFL

LFL LED

YEARWARRANTY

ConvertibleLED

ConvertibleLFL

LFL LED

DIRECT INDIRECT LAMP TYPE

LAMP UP

HOUSING LAMPS DOWN

LENGTH MOUNTING VOLTAGE CIRCUITING FINISH OPTIONS

T5, T5HO, & T8 Direct and Indirect Linear with Straight Lamp / Satine Lens

EDGEE V O L U T I O N

1No T8 available. 2Standard 48” adjustable aircraft cable. Consult factory for additional lengths. Single Aircraft Cable mounts 4’ and 8’ on center. Mount locations are not adjustable. 3Consult factory for tegular edged tiles. 4Replaces standard 2” canopy. 5Standard 48” adjustable Y-cable mount provided. Consult factory for additional lengths. Moveable Aircraft Cable mount allows for flexible mounting loca-tions. Maximum mounting locations are 12” from end of 4’ fixture and 18” from end of 8’ fixture. 6347V and UNV not available with battery pack and MR16. 7Some Edge configurations will not accommodate all electrical options. Consult factory. 8Consult factory for configurations using MR16 units. 120 volt only available. 9Integral battery packs with remote test switch are provided with 1B and 2B options on 2T5/2T5HO fixtures. 10Dual circuit = top and bottom lamps are on separate circuits. 11If canopy is to match fixture housing, must specify in options section with CC-C. if not specified, canopy will be standard matte white.

MOUNTING Aircraft cable, wall and surface mount available. Select from 2 aircraft cable options. Select the straight aircraft cable that mounts on 4’-0” and 8’-0” centers or the moveable adjustable Y-cable mount. The Y-Cable design allows for adjustable mounting locations. (See installation instructions for MR16 mounting detail). Aircraft Cable supplied with 5” power and 2” non-power canopies. Refer to installation instructions for appropriate ceiling detail. Canopies are painted white unless otherwise specified.

AC48G1-AC48G9-AC48GS-AC48JB-AC48ST-AC5__G_-AC5__JB-SQ48G_-SQ48JB-

1” T-Bar3 9/16” T-Bar3

Slotted T-Bar3

Junction BoxStructure5” Non-Power Canopy4

5” Non-Power Canopy4

5” Square Canopy4

5” Square Canopy4

Single Aircraft Cable2

WallWA- Wall Mount

MAC48G1-MAC48G9-MAC48GS-MAC48JB-MAC48ST-MAC5__G_-MAC5__JB-MSQ48G_-MSQ48JB-

1” T-Bar3 9/16” T-Bar3

Slotted T-Bar3

Junction BoxStructure5” Non-Power Canopy4

5” Non-Power Canopy4

5” Square Canopy4

5” Square Canopy4

Moveable Aircraft Cable5

ConvertibleLED

ConvertibleLFL

LFL LED

LampsStaggered

LampsStaggered

MR16 Corners

DaylightSensor

InstallationInstructions

Year LEDWarranty

ELECTRICAL T5, T5HO: Standard programmed start UL listed Class P, T5 electronic, sound rated A, thermally protected, high power factor ballasts less than 10% THD, universal voltage (120-277) with 50/60Hz operation. T8: Standard instant start UL listed Class P, T8 electronic, Sound Rated A, thermally protected, high power factor ballasts less than 10% THD, universal voltage (120-277). Through wiring with quick connects standard. Standard single circuit. Integral battery packs with remote test switch are provided with 1B and 2B options on 2T5/2T5HO fixtures. Each ballast pro-vided with disconnects to meet luminaire disconnect code requirement.

5-3/8”

3-1/2”

5-3/8”

3-1/2”

5-3/8”

3-1/2”

5-3/8”

3-1/2”

(1) or (2) Straight Lamps

See Straight Lamp Guide for row configuration, wattage and number of lamps per run.

2T5/T5HO1T5/T5HO 1T8

5-3/8”

3-1/2”

(1) or (2) Straight Lamps

See Straight or Staggered Lamp Guide for row configuration, wattage and number of lamps per run.

2T5/T5HO1T5/T5HO 1T8

5-3/8”

3-1/2”

(1) or (2) Straight Lamps

See Straight or Staggered Lamp Guide for row configuration, wattage and number of lamps per run.

2T5/T5HO1T5/T5HO 1T8

5-3/8”

3-1/2”

(1) or (2) Straight Lamps

See Straight Lamp Guide for row configuration, wattage and number of lamps per run.

2T5/T5HO1T5/T5HO 1T8

?Don’t

Recommend

FINISH Standard powder-coat textured white, metallic silver, textured black or bronze painted finish, consult factory for chip of standard paint finishes. Pendants and canopies painted white unless specified differently in the options section of the part number. Contact factory for additional ustom color and finish options.

P H O T O M E T R I C S E D G E E X 3 B _ A

INDIVIDUAL MODULES 1 MOUNTING OPTIONS

Specifi cations and dimensions subject to change without notice. Specifi cation sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.

®

®

®

Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com© 2015 Pinnacle Architectural Lighting® June 2015

1/2"

WA - Wall Mount

ADA Compliant

AC - Single Aircraft Cable

MAC - Moveable Aircraft Cable

1/2"

WA - Wall Mount

ADA Compliant

AC - Single Aircraft Cable

MAC - Moveable Aircraft Cable

1/2"

WA - Wall Mount

ADA Compliant

AC - Single Aircraft Cable

MAC - Moveable Aircraft Cable

1/2"

WA - Wall Mount

ADA Compliant

AC - Single Aircraft Cable

MAC - Moveable Aircraft Cable

4'(1) lens per 4' unit (4’ individual unit not available with staggered lamp)

8'(1) lens per 8' unit

1Add 1/4” for each end plate or 1/2” to the overall length of the row.

1Add 1/4” for each end plate or 1/2” to the overall length of the row.

1Add 1/4” for each end plate or 1/2” to the overall length of the row.

48”

96”

EX3C, EX3D

4'(1) lens per 4' unit (4’ individual unit not available with staggered lamp)

8'(1) lens per 8' unit

48”

96”

EX3A, EX3H

4'(1) louver per 4' unit (4’ individual unit not available with staggered lamp)

8'(2) louvers per 8' unit

48”

96”

EX3P

4'(1) lens per 4' unit

8'(1) lens per 8' unit

1Add 1/4” for each end plate or 1/2” to the overall length of the row.

1Add 1/4” for each end plate or 1/2” to the overall length of the row.

1Add 1/4” for each end plate or 1/2” to the overall length of the row.

48”

96”

EX3C, EX3D

4'(1) lens per 4' unit

8'(1) lens per 8' unit

48”

96”

EX3A, EX3H

4'(1) louver per 4' unit

8'(2) louvers per 8' unit

48”

96”

EX3P

Test #: 205778 Part #: EX3B-A-O-T5-1-2-4’Total Luminaire Efficiency: 79%

1568

1176

784

392

Test #: 205792 Part #: EX3B-A-O-T8-1-1-4’Total Luminaire Efficiency: 75%

625

619

412

206

Test #: 205782 Part #: EX3B-A-O-T5-2-2-4’Total Luminaire Efficiency: 73%

1581

1186

790

395

Test #: 205780 Part #: EX3B-A-O-T5-2-1-4’Total Luminaire Efficiency: 71%

1337

1008

668

334

Test #: 205776 Part #: EX3B-A-O-T5-1-1-4’Total Luminaire Efficiency: 79%

755

566

377

189

EX3B-A

Test #: 205831 Part #: EX3B-C-O-T5-1-2-4’Total Luminaire Efficiency: 78%

1576

1182

788

394

Test #: 205845 Part #: EX3B-C-O-T8-1-1-4’Total Luminaire Efficiency: 74%

827

620

413

207

Test #: 205835 Part #: EX3B-C-O-T5-2-2-4’Total Luminaire Efficiency: 72%

1582

1187

791

396

Test #: 205833 Part #: EX3B-C-O-T5-2-1-4’Total Luminaire Efficiency: 70%

1253

940

626

313

Test #: 205829 Part #: EX3B-C-O-T5-1-1-4’Total Luminaire Efficiency: 78%

752

564

376

188

EX3B-C

Test #: 205868 Part #: EX3B-D-O-T5-1-2-4’Total Luminaire Efficiency: 81%

1578

1188

788

394

Test #: 205882 Part #: EX3B-D-O-T8-1-1-4’Total Luminaire Efficiency: 78%

828

621

414

207

Test #: 205872 Part #: EX3B-D-O-T5-2-2-4’Total Luminaire Efficiency: 76%

1583

1187

792

396

Test #: 205870 Part #: EX3B-D-O-T5-2-1-4’Total Luminaire Efficiency: 76%

1489

1117

744

372

Test #: 205866 Part #: EX3B-D-O-T5-1-1-4’Total Luminaire Efficiency: 83%

765

574

382

191

EX3B-D

MR16 LAMP APPLICATION: MR16’s are ideal for conference rooms, corridors, wall washing, retail spaces and training facil-ities where accent lighting is required.

ORDERING INFORMATION: MR16’s should be specified utilizing MR16 layout guide.

LABELS: UL and cUL Listed, approved for dry/damp location unless otherwise noted.

ELECTRICAL: Standard 50 watt max halogen lamp transformer (120v or 277v), 60 watt max LED electronic transformer (120v only). MR16 installed as indepen-dent circuit. MR16 voltage to match fluorescent voltage.

TECHNICAL: MR16 fully enclosed compartment elimi-nates light from entering into other fixture areas. Avail-able in 20, 35 and 50 watt halogen lamps, up to 12 watt LED lamps (lamps not included). Consult factory for other lamp types/ wattages.

Test #: 205778 Part #: EX3B-A-O-T5-1-2-4’Total Luminaire Efficiency: 79%

1568

1176

784

392

Test #: 205792 Part #: EX3B-A-O-T8-1-1-4’Total Luminaire Efficiency: 75%

625

619

412

206

Test #: 205782 Part #: EX3B-A-O-T5-2-2-4’Total Luminaire Efficiency: 73%

1581

1186

790

395

Test #: 205780 Part #: EX3B-A-O-T5-2-1-4’Total Luminaire Efficiency: 71%

1337

1008

668

334

Test #: 205776 Part #: EX3B-A-O-T5-1-1-4’Total Luminaire Efficiency: 79%

755

566

377

189

EX3B-A

Test #: 205831 Part #: EX3B-C-O-T5-1-2-4’Total Luminaire Efficiency: 78%

1576

1182

788

394

Test #: 205845 Part #: EX3B-C-O-T8-1-1-4’Total Luminaire Efficiency: 74%

827

620

413

207

Test #: 205835 Part #: EX3B-C-O-T5-2-2-4’Total Luminaire Efficiency: 72%

1582

1187

791

396

Test #: 205833 Part #: EX3B-C-O-T5-2-1-4’Total Luminaire Efficiency: 70%

1253

940

626

313

Test #: 205829 Part #: EX3B-C-O-T5-1-1-4’Total Luminaire Efficiency: 78%

752

564

376

188

EX3B-C

Test #: 205868 Part #: EX3B-D-O-T5-1-2-4’Total Luminaire Efficiency: 81%

1578

1188

788

394

Test #: 205882 Part #: EX3B-D-O-T8-1-1-4’Total Luminaire Efficiency: 78%

828

621

414

207

Test #: 205872 Part #: EX3B-D-O-T5-2-2-4’Total Luminaire Efficiency: 76%

1583

1187

792

396

Test #: 205870 Part #: EX3B-D-O-T5-2-1-4’Total Luminaire Efficiency: 76%

1489

1117

744

372

Test #: 205866 Part #: EX3B-D-O-T5-1-1-4’Total Luminaire Efficiency: 83%

765

574

382

191

EX3B-D