ec941427 test report - logitech emc...tel : 886-2-2696-2468 issued date : apr. 21, 2009 fax :...

63
EMC TEST REPORT Report No. : EC941427 SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 EMC TEST REPORT according to European Standard EN 55022:2006/A1:2007 Class B, EN 61000-3-2:2006, EN 61000-3-3:1995/A1:2001/A2:2006, EN 55024:1998/A1:2001/A2:2003 (IEC 61000-4-2:Edition 1.2:2001-04, IEC 61000-4-3:Edition 2.1:2002-09, IEC 61000-4-4:Second Edition:2004-07, IEC 61000-4-5:Edition1.1:2001-04, IEC 61000-4-6:Edition 2.1:2004-11, IEC 61000-4-8:Edition 1.1:2001-03, IEC 61000-4-11:Second Edition:2004-03) and AS/NZS CISPR22:2006 Class B Equipment : USB video camera Model No. : V-U0011 Applicant : Logitech Far East Ltd. 2 Creation Road IV, Science-Based Ind. Park, Hsinchu, Taiwan. The test result refers exclusively to the test presented test model / sample. Without written approval of SPORTON International Inc., the test report shall not be reproduced except in full. This test report is only applicable to European Community. SPORTON International Inc. 6F, No. 106, Sec. 1, Hsin Tai Wu Rd., Hsi Chih, Taipei Hsien, Taiwan, R.O.C.

Upload: others

Post on 06-Jul-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc.TEL : 886-2-2696-2468FAX : 886-2-2696-2255

EMC TEST REPORT according to

European Standard EN 55022:2006/A1:2007 Class B, EN 61000-3-2:2006, EN 61000-3-3:1995/A1:2001/A2:2006,

EN 55024:1998/A1:2001/A2:2003 (IEC 61000-4-2:Edition 1.2:2001-04, IEC 61000-4-3:Edition 2.1:2002-09,

IEC 61000-4-4:Second Edition:2004-07, IEC 61000-4-5:Edition1.1:2001-04, IEC 61000-4-6:Edition 2.1:2004-11, IEC 61000-4-8:Edition 1.1:2001-03,

IEC 61000-4-11:Second Edition:2004-03) and AS/NZS CISPR22:2006 Class B

Equipment : USB video camera

Model No. : V-U0011

Applicant : Logitech Far East Ltd. 2 Creation Road IV, Science-Based Ind. Park, Hsinchu, Taiwan.

The test result refers exclusively to the test presented test model / sample. Without written approval of SPORTON International Inc., the test report shall not be reproduced

except in full. This test report is only applicable to European Community.

SPORTON International Inc. 6F, No. 106, Sec. 1, Hsin Tai Wu Rd., Hsi Chih, Taipei Hsien, Taiwan, R.O.C.

Page 2: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : i TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

Table of Contents

History of this test report .................................................................................................................iii CERTIFICATE OF COMPLIANCE........................................................................................................................1 1. General Description of Equipment under Test.............................................................................................2

1.1. Applicant..........................................................................................................................................................................................2 1.2. Manufacturer ...................................................................................................................................................................................2 1.3. Basic Description of Equipment under Test ....................................................................................................................................2 1.4. Feature of Equipment under Test ...................................................................................................................................................2

2. Test Configuration of Equipment under Test ...............................................................................................3 2.1. Test Manner ....................................................................................................................................................................................3 2.2. Description of Test System .............................................................................................................................................................3

3. Test Software ...................................................................................................................................................4 4. General Information of Test............................................................................................................................5

4.1. Test Facility .....................................................................................................................................................................................5 4.2. Test Voltage ....................................................................................................................................................................................5 4.3. Standard for Methods of Measurement...........................................................................................................................................5 4.4. Test in Compliance with ..................................................................................................................................................................5 4.5. Frequency Range Investigated .......................................................................................................................................................6 4.6. Test Distance ..................................................................................................................................................................................6

5. Test of Conducted Powerline .........................................................................................................................7 5.1. Description of Major Test Instruments ............................................................................................................................................7 5.2. Test Procedures ..............................................................................................................................................................................7 5.3. Typical Test Setup Layout of Conducted Powerline .......................................................................................................................8 5.4. Test Result of AC Powerline Conducted Emission .........................................................................................................................9 5.5. Photographs of Conducted Powerline Test Configuration ............................................................................................................11

6. Test of Radiated Emission............................................................................................................................12 6.1. Description of Major Test Instruments ..........................................................................................................................................12 6.2. Test Procedures ............................................................................................................................................................................14 6.3. Typical Test Setup Layout of Radiated Emission..........................................................................................................................15 6.4. Test Result of Radiated Emission .................................................................................................................................................16 6.5. Photographs of Radiated Emission Test Configuration ................................................................................................................22

7. Harmonics Test..............................................................................................................................................23 8. Voltage Fluctuations Test.............................................................................................................................24 9. Electrostatic Discharge Immunity Test (ESD) ............................................................................................25

9.1. Test Setup .....................................................................................................................................................................................25 9.2. Test Setup for Tests Performed in Laboratory ..............................................................................................................................26 9.3. ESD Test Procedure .....................................................................................................................................................................27 9.4. Test Severity Levels ......................................................................................................................................................................28 9.5. Test Points ....................................................................................................................................................................................29 9.6. Photographs of Electrostatic Discharge Immunity Test ................................................................................................................30

10. Radio Frequency Electromagnetic Field Immunity Test (RS).................................................................32 10.1. Test Setup ...................................................................................................................................................................................32 10.2. Test Procedure............................................................................................................................................................................33 10.3. Test Severity Levels ....................................................................................................................................................................33 10.4. Photographs of Radio Frequency Electromagnetic Field Immunity Test ....................................................................................34

Page 3: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : ii TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

11. Electrical Fast Transient/Burst Immunity Test (EFT/BURST) .................................................................35 12. Surge Immunity Test ...................................................................................................................................36 13. Conducted Disturbances Induced by Radio-Frequency Field Immunity Test ( CS )............................37 14. Power Frequency Magnetic Field Immunity Tests...................................................................................38 15. Voltage Dips and Voltage Interruptions Immunity Tests ........................................................................39 16. List of Measuring Equipment Used ...........................................................................................................40 Appendix A. Photographs of EUT........................................................................................................ A1 ~ A18

Page 4: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : iii TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

History of this test report

Original Report Issue Date: Apr. 21, 2009 Report No. : EC941427 ■ No additional attachment. □ Additional attachment were issued as following record:

Attachment No. Issue Date Description

Page 5: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009
Page 6: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 2 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

1. General Description of Equipment under Test

1.1. Applicant Logitech Far East Ltd. 2 Creation Road IV, Science-Based Ind. Park, Hsinchu, Taiwan.

1.2. Manufacturer Same as 1.1.

1.3. Basic Description of Equipment under Test

Equipment : USB video camera

Model No. : V-U0011

Trade Name : Logitech

Power Supply Type : From Host System

USB Cable : 1.80, Shielded

1.4. Feature of Equipment under Test Please refer to user manual for others.

Page 7: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 3 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

2. Test Configuration of Equipment under Test

2.1. Test Manner

a. During testing, the interface cables and equipment positions were varied according to

European Standard EN 55022 and AS/NZS CISPR22.

b. The complete test system included DELL Notebook, HP Mouse and EUT for EMI test.

c. The complete test system included DELL Notebook and EUT for EMS test.

d. Frequency range investigated: conduction 150 kHz to 30 MHz, radiation 30 MHz to 3000 MHz.

2.2. Description of Test System < EMI >

Support Unit 1. -- Notebook (DELL) FCC ID : E2K4965AGNM Model No. : PP25L Power Supply Type : Switching Power Cord : Non-Shielded Serial No. : NB-N

Support Unit 2. -- Mouse (HP) FCC ID : N/A Model No. : M-UAE96 Serial No. : MO-A Data Cable : Shielded, 1.8m Remark : This support device was tested to comply with FCC standards and

authorized under a declaration of conformity.

< EMS >

Support Unit 1. -- Notebook (DELL) FCC ID : E2K4965AGNM Model No. : PP25L Power Supply Type : Switching Power Cord : Non-Shielded Serial No. : NB-N

Page 8: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 4 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

3. Test Software < EMI > An executive program, EMCTEST.EXE under WIN XP, which generates a complete line of continuously repeating “ H “ pattern was used as the test software.

The program was executed as follows :

a. Turn on the power of all equipment.

b. The NB sends “ H“ messages to the panel, and the panel displays “ H “ patterns on the screen.

At the same time, “Logitech Webcam 200” was executed to display the capturing image from EUT.

< EMS >

During the test, the following programs under WIN XP were executed:

Executed “Logitech Webcam 200” to display the capturing image from EUT.

Page 9: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 5 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

4. General Information of Test

4.1. Test Facility

<EMI>

Test Site Location : No.8, Lane 724, Bo-ai St., Jhubei City,

Hsinchu County 302, Taiwan, R.O.C.

TEL : 886-3-656-9065

FAX : 886-3-656-9085

Test Site No. : Conduction : CO01-CB; Radiation : 10CH01-CB

<EMS>

Test Site Location : No.8, Lane 724, Bo-ai St., Jhubei City,

Hsinchu County 302, Taiwan, R.O.C.

TEL : 886-3-656-9065

FAX : 886-3-656-9085

4.2. Test Voltage

230V / 50Hz

4.3. Standard for Methods of Measurement

EMI Test (conduction and radiation) : European Standard EN 55022 Class B and AS/NZS CISPR22 Class B

Harmonics Test : European Standard EN 61000-3-2

Voltage Fluctuations Test : European Standard EN 61000-3-3

EMS Test : European Standard EN 55024

(ESD: IEC 61000-4-2, RS: IEC 61000-4-3, EFT: IEC 61000-4-4, SURGE: IEC 61000-4-5,

CS: IEC 61000-4-6, Power Frequency Magnetic Field: IEC 61000-4-8, DIPS: IEC 61000-4-11)

4.4. Test in Compliance with

EMI Test (conduction and radiation) : European Standard EN 55022 Class B and AS/NZS CISPR22 Class B

Harmonics Test : European Standard EN 61000-3-2

Voltage Fluctuations Test : European Standard EN 61000-3-3

EMS Test : European Standard EN 55024

(ESD: IEC 61000-4-2, RS: IEC 61000-4-3, EFT: IEC 61000-4-4, SURGE: IEC 61000-4-5,

CS: IEC 61000-4-6, Power Frequency Magnetic Field: IEC 61000-4-8, DIPS: IEC 61000-4-11)

Page 10: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 6 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

4.5. Frequency Range Investigated

a. Conducted emission test: from 150 kHz to 30 MHz

b. Radiated emission test: from 30 MHz to 3000 MHz

c. Radio frequency electromagnetic field immunity test: 80-1000 MHz.

4.6. Test Distance

a. The test distance of radiated emission test from antenna to EUT is 10 m (from 30MHz~1000MHz).

b. The test distance of radiated emission test from antenna to EUT is 3 m (from 1GHz~3GHz).

c. The test distance of radio frequency electromagnetic field immunity test from antenna to EUT is 3 m.

Page 11: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 7 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

5. Test of Conducted Powerline

Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 kHz and return leads of

the EUT according to the methods defined in European Standard EN 55022 Clause 9 and AS/NZS CISPR22.

The EUT was placed on a nonmetallic stand in a shielded room 0.8 meters above the ground plane as shown

in section 5.3. The interface cables and equipment positioning were varied within limits of reasonable

applications to determine the position producing maximum conducted emissions.

5.1. Description of Major Test Instruments

Test Receiver (R&S ESCS 30)

Attenuation 10 dB

Start Frequency 0.15 MHz

Stop Frequency 30 MHz

IF Bandwidth 9kHz

5.2. Test Procedures

a. The EUT was placed on a desk 0.8 meters height from the metal ground plane and 0.4 meter from the

conducting wall of the shielding room and it was kept at least 0.8 meters from any other grounded

conducting surface.

b. Connect EUT to the power mains through a line impedance stabilization network (LISN).

c. Connect Telecommunication port to ISN (Impedance Stabilization Network).

d. All the support units are connect to the other LISN.

e. The LISN provides 50 ohm coupling impedance for the measuring instrument.

f. The CISPR states that a 50 ohm, 50 microhenry LISN should be used.

g. Both sides of AC line were checked for maximum conducted interference.

h. The frequency range from 150 kHz to 30 MHz was searched.

i. Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum Hold

Mode.

Page 12: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 8 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

5.3. Typical Test Setup Layout of Conducted Powerline

L.I.S.N.

10 cm

80 cm to the ground plane

L.I.S.N.

Page 13: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 9 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

5.4. Test Result of AC Powerline Conducted Emission

Frequency Range of Test: from 0.15 MHz to 30 MHz Temperature: 26 °C Relative Humidity: 60 % Corrected Reading (dBuV) = LISN Factor + Cable Loss + Read Level = Level All emissions not reported here are more than 10 dB below the prescribed limit.

■ The test was passed at the minimum margin that marked by a frame in the following table

Line

Page 14: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 10 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

Neutral

Test Engineer : Howar Sung

Page 15: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 11 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

5.5. Photographs of Conducted Powerline Test Configuration The photographs show the configuration that generates the maximum emission.

FRONT VIEW

REAR VIEW

Page 16: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 12 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

6. Test of Radiated Emission

Radiated emissions from 30 MHz to 1000 MHz were measured with a bandwidth of 120 kHz for

30MHz~1GHz, 1MHz for above 1GHz according to the methods defines in European Standard EN 55022,

Clause 10 and AS/NZS CISPR22. The EUT was placed on a nonmetallic stand, 0.8 meter above the ground

plane, as shown in section 6.3. The interface cables and equipment positions were varied within limits of

reasonable applications to determine the positions producing maximum radiated emissions.

6.1. Description of Major Test Instruments

6.1.1. 30MHz~1GHz

Amplifier (Agilent 8447D)

RF Gain 25 dB

Signal Input 9 KHz to 1.3 GHz

Spectrum Analyzer (R&S FSP40)

Attenuation 10 dB

Start Frequency 30 MHz

Stop Frequency 1000 MHz

Resolution Bandwidth 120 KHz

Signal Input 9 KHz to 40 GHz

Test Receiver (R&S ESCI)

Attenuation 10 dB

Start Frequency 30 MHz

Stop Frequency 1000 MHz

Resolution Bandwidth 120 KHz

Signal Input 9kHz to 3 GHz

Page 17: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 13 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

6.1.2. Above 1GHz

Amplifier (Agilent 8449B)

RF Gain 35 dB

Signal Input 1GHz – 26.5 GHz

Spectrum Analyzer (R&S FSP40)

Attenuation 10 dB

Start Frequency 1 GHz

Stop Frequency 18 GHz

Resolution Bandwidth 1 MHz

Video Bandwidth 1 MHz

Signal Input 9 kHz – 40 GHz

Page 18: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 14 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

6.2. Test Procedures

a. The EUT was placed on a rotatable table top 0.8 meter above ground.

b. The EUT was set 3/10 meters from the interference receiving antenna which was mounted on the top

of a variable height antenna tower.

c. The table was rotated 360 degrees to determine the position of the highest radiation.

d. The antenna is a half wave dipole and its height is varied between one meter and four meters above

ground to find the maximum value of the field strength both horizontal polarization and vertical

polarization of the antenna are set to make the measurement.

e. For each suspected emission the EUT was arranged to its worst case and then tune the antenna

tower (from 1 M to 4 M) and turn table (from 0 degree to 360 degrees) to find the maximum reading.

f. Set the test-receiver system to Peak Detect Function and specified bandwidth with Maximum Hold

Mode.

g. If the emission level of the EUT in peak mode was 3 dB lower than the limit specified, then testing will

be stopped and peak values of EUT will be reported, otherwise, the emissions which do not have 3 dB

margin will be repeated one by one using the quasi-peak method and reported.

Page 19: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 15 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

6.3. Typical Test Setup Layout of Radiated Emission

Antenna

0.8 M

Equipment under Test

Test distance

TurnTable

Ground Plane

Receiver

Page 20: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 16 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

6.4. Test Result of Radiated Emission Frequency Range of Test : from 30 MHz to 1,000 MHz Test Distance: 10m Temperature: 25.6 ℃ Relative Humidity: 56 % Emission level (dBuV/m) = 20 log Emission level (uV/m) Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level

■ The test was passed at the minimum margin that marked by the frame in the following test record

Vertical

Page 21: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 17 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

Vertical

Page 22: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 18 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

Horizontal

Page 23: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 19 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

Horizontal

Test Engineer : Aric Li

Page 24: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 20 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

Frequency Range of Test: from 1000MHz to 3000 MHz

Test Distance: 3m Temperature: 25.6 ℃ Relative Humidity: 56 % Emission level (dBuV/m) = 20 log Emission level (uV/m) Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level

■ The test was passed at the minimum margin that marked by the frame in the following test record

Vertical

Page 25: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 21 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

Horizontal

Test Engineer : Aric Li

Page 26: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 22 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

6.5. Photographs of Radiated Emission Test Configuration The photographs show the configuration that generates the maximum emission.

FRONT VIEW

REAR VIEW

Page 27: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 23 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

7. Harmonics Test

According to EN 61000-3-2, it only applicable for the device which’s operating current up to 16A per phase. Since the EUT is powered from host system, it was deemed that it passes the test without testing.

Page 28: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 24 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

8. Voltage Fluctuations Test

According to EN 61000-3-3, it only applicable for the device which’s operating current up to 16A per phase. Since the EUT is powered from host system, it was deemed that it passes the test without testing.

Page 29: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 25 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

9. Electrostatic Discharge Immunity Test (ESD) Final Test Result : PASS Pass Performance Criteria : A Required Performance Criteria : B Basic Standard : IEC 61000-4-2:Edition 1.2:2001-04 Product Standard : EN 55024:1998/A1:2001/A2:2003 Level : 3 for air discharge,

: 2 for contact discharge Tested voltage : ±2 / ±4 / ±8 kV for air discharge,

: ±2 / ±4 kV for contact discharge Temperature : 22 °C Relative Humidity : 41 % Atmospheric Pressure : 98.6 kPa Test Date : Apr. 20, 2009 Observation : Normal

9.1. Test Setup

The test setup consists of the test generator, EUT and auxiliary instrumentation necessary to perform DIRECT and INDIRECT application of discharges to the EUT as applicable, in the follow manner:

a. CONTACT DISCHARGE to the conductive surfaces and to coupling plane; b. AIR DISCHARGE at insulating surfaces.

The preferred test method is that of type tests performed in laboratories and the only accepted method of demonstrating conformance with this standard. The EUT was arranged as closely as possible to arrangement in final installed conditions.

Page 30: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 26 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

9.2. Test Setup for Tests Performed in Laboratory A ground reference plane was provided on the floor of the test site. It was a metallic sheet (copper or aluminum) of 0.25 mm, minimum thickness; other metallic may be used but they shall have at least 0.65 mm thickness. In the SPORTON EMC LAB., we provided 1 mm thickness aluminum ground reference plane or 1 mm thickness stainless steel ground reference plane. The minimum size of the ground reference plane is 1 m x 1 m, the exact size depending on the dimensions of the EUT. It was connected to the protective grounding system. The EUT was arranged and connected according to its functional requirements. A distance of 1m minimum was provided between the EUT and the wall of the lab. and any other metallic structure. In cases where this length exceeds the length necessary to apply the discharges to the selected points, the excess length shall, where possible, be placed non-inductively off the ground reference plane and shall not come closer than 0.2m to other conductive parts in the test setup. Where the EUT is installed on a metal table, the table was connected to the reference plane via a cable with a 470k ohm resister located at each end, to prevent a build-up of charge. The test setup was consist a wooden table, 0.8m high, standing on the ground reference plane. A HCP, 1.6 m x 0.8 m, was placed on the table. The EUT and cables was isolated from the HCP by an insulating support 0.5 mm thick. The VCP size, 0.5 m x 0.5 m.

Page 31: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 27 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

9.3. ESD Test Procedure

a. In the case of air discharge testing the climatic conditions shall be within the following ranges: - ambient temperature: 15°C to 35°C; - relative humidity : 30% to 60%; - atmospheric pressure : 86 kPa (860 mbar) to 106 kPa (1060 mbar).

b. Test programs and software shall be chosen so as to exercise all normal modes of operation of the EUT.

The use of special exercising software is encouraged, but permitted only where it can be shown that the EUT is being comprehensively exercised.

c. The test voltage shall be increased from the minimum to the selected test severity level, in order to determine any threshold of failure. The final severity level should not exceed the product specification value in order to avoid damage to the equipment.

d. The test shall be performed with both air discharge and contact discharge. On preselected points at least 10 single discharges (in the most sensitive polarity) shall be applied on air discharge. On preselected points at least 25 single discharges (in the most sensitive polarity) shall be applied on contact discharge.

e. For the time interval between successive single discharges an initial value of one second is recommended. Longer intervals may be necessary to determine whether a system failure has occurred.

f. In the case of contact discharges, the tip of the discharge electrode shall touch the EUT before the discharg e switch is operated.

g. In the case of painted surface covering a conducting substrate, the following procedure shall be adopted:

- If the coating is not declared to be an insulating coating by the equipment manufacturer, then the pointed tip of the generator shall penetrate the coating so as to make contact with the conducting substrate.

- Coating declared as insulating by the manufacturer shall only be submitted to the air discharge. - The contact discharge test shall not be applied to such surfaces.

h. In the case of air discharges, the round discharge tip of the discharge electrode shall be approached as fast as possible (without causing mechanical damage) to touch the EUT . After each discharge, the ESD generator (discharge electrode) shall be removed from the EUT. The generator is then retriggered for a new single discharge. This procedure shall be repeated until the discharges are completed. In the case of an air discharge test, the discharge switch, which is used for contact discharge, shall be closed.

Page 32: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 28 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

9.4. Test Severity Levels

9.4.1. Contact Discharge

Level Test Voltage (kV) of Contact discharge

1 ±2 2 ±4 3 ±6 4 ±8 X Specified

Remark : “X” is an open level.

9.4.2. Air Discharge

Level Test Voltage (kV) of Air Discharge

1 ±2 2 ±4 3 ±8 4 ±15 X Specified

Remark : “X” is an open level.

Page 33: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 29 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

9.5. Test Points

9.5.1. Test Result of Air Discharge

Test Point Voltage Tested No.

Case / bracket ±2 / ±4 / ±8 KV BY 10

CCD ±2 / ±4 / ±8 KV BY 10

LED ±2 / ±4 / ±8 KV BY 10

9.5.2. Test Result of Contact Discharge

Test Point Voltage Tested No.

HCP (At Front) ±2 / ±4 kV BY 25

HCP (At Left) ±2 / ±4 kV BY 25

HCP (At Right) ±2 / ±4 kV BY 25

HCP (At Rear) ±2 / ±4 kV BY 25

VCP (At Front) ±2 / ±4 kV BY 25

VCP (At Left) ±2 / ±4 kV BY 25

VCP (At Right) ±2 / ±4 kV BY 25

VCP (At Rear) ±2 / ±4 kV BY 25

USB PORT ±2 / ±4 kV BY 25

Test Engineer: Peter Wu

Page 34: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 30 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

9.6. Photographs of Electrostatic Discharge Immunity Test

FRONT VIEW

REAR VIEW

Page 35: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 31 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

Description : Electronics Discharge (ESD) of Test Point

Description: ”A” means Air Discharge “C” means Contact Discharge

Description: ”A” means Air Discharge “C” means Contact Discharge

A A

A

A

Page 36: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 32 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

10. Radio Frequency Electromagnetic Field Immunity Test (RS) Final Test Result : PASS Pass Performance Criteria : A Required Performance Criteria : A Basic Standard : IEC 61000-4-3:Edition 2.1:2002-09 Product Standard : EN 55024:1998/A1:2001/A2:2003 Level : 2 Frequency Range : 80-1000 MHz Field Strength : 3 V/m (unmodulated, r.m.s) 80% AM (1 kHz) Temperature : 25 °C Relative Humidity : 58 % Atmospheric Pressure : 98.6 kPa Test Date : Apr. 20, 2009 Observation : Normal

10.1. Test Setup

Note: The SPORTON 12m × 7m × 7m Fully Anechoic chamber is compliance with the sixteen points uniform field requirement as stated in IEC 1000-4-3 Section 6.2.

The procedure defined in this part requires the generation of electromagnetic fields within which the test sample is placed and its operation observed. To generate fields that are useful for simulation of actual (field) conditions may require significant antenna drive power and the resultant high field strength levels.

Page 37: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 33 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

10.2. Test Procedure

a. The equipment to be tested is placed in the center of the enclosure on a wooden table. The equipment is then connected to power and signal leads according to pertinent installation instructions.

b. The bilog antenna which is enabling the complete frequency range of 80-1000 MHz is placed 3m away from the equipment. The required field strength is determined by placing the field strength meter(s) on top of or directly alongside the equipment under test and monitoring the field strength meter via a remote field strength indicator outside the enclosure while adjusting the continuous-wave to the applicable antennae.

c. The test is normally performed with the generating antenna facing each of four sides of the EUT. The polarization of the field generated by the broadband (bilog) antenna necessitates testing each position twice, once with the antenna positioned vertically and again with the antenna positioned horizontally.

d. At each of the above conditions, the frequency range is swept 80-1000 MHz, pausing to adjust the R.F. signal level or to switch oscillators and antenna. The rate of sweep is in the order of 1.5*10-3 decades/s. The sensitive frequencies or frequencies of dominant interest may be discretely analyzed.

10.3. Test Severity Levels

Frequency Band : 80-1000 MHz

Level Test field strength (V/m)

1 1

2 3

3 10

X Specified

Remark : “X” is an open class.

Test Engineer: Peter Wu

Page 38: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 34 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

10.4. Photographs of Radio Frequency Electromagnetic Field Immunity Test

FRONT VIEW

REAR VIEW

Page 39: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 35 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

11. Electrical Fast Transient/Burst Immunity Test (EFT/BURST) Due to the EUT is powered from host system; it’s not necessary to apply for this test.

Page 40: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 36 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

12. Surge Immunity Test Due to the EUT is powered from host system; it’s not necessary to apply for this test.

Page 41: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 37 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

13. Conducted Disturbances Induced by Radio-Frequency Field Immunity Test ( CS )

Due to the EUT is powered from host system; it’s not necessary to apply for this test.

Page 42: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 38 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

14. Power Frequency Magnetic Field Immunity Tests Due to the EUT is powered from host system; it’s not necessary to apply for this test.

Page 43: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 39 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

15. Voltage Dips and Voltage Interruptions Immunity Tests Due to the EUT is powered from host system; it’s not necessary to apply for this test.

Page 44: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 40 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

16. List of Measuring Equipment Used <EMI>

※ Calibration Interval of instruments listed above is one year.

Instrument Manufacturer Model No. Serial No. Characteristics Calibration Date Remark

EMI Test Receiver R&S ESCS 30 100377 9kHz ~ 2.75GHz Mar. 27, 2009 Conduction (CO01-CB)

LISN F.C.C. FCC-LISN-50-

16-2 04083 150kHz ~ 100MHz Apr. 11, 2009

Conduction (CO01-CB)

V- LISN Schwarzbeck NSLK 8127 8127-478 9K ~ 30MHz Sep. 05, 2008 Conduction (CO01-CB)

PULSE LIMITER R&S ESH3-Z2 100430 9K~30MHz Jan. 04, 2009 Conduction (CO01-CB)

10m Semi Anechoic Chamber

TDK SAC-10M 10CH01-CB30MHz~1GHz

10m, 3m Nov. 21, 2008

Radiation (10CH01-CB)

Pre-Amplifier Agilent 8447D 2944A10783 9KHz ~ 1.3GHz Nov. 06, 2008 Radiation

(10CH01-CB)

Pre-Amplifier Agilent 8447D 2944A10784 9KHz ~ 1.3GHz Nov. 06, 2008 Radiation

(10CH01-CB)

Biconical Antenna Schwarzbeck VHBB 9124 324 30MHz ~ 200MHz Dec. 01, 2008 Radiation

(10CH01-CB)

Log Antenna Schwarzbeck VUSLP 9111 247 200MHz ~ 1GHz Dec. 01, 2008 Radiation

(10CH01-CB)

EMI Test Receiver R&S ESCI 100186 9KHZ ~ 3GHz Mar. 09, 2009 Radiation

(10CH01-CB)

Spectrum Analyzer R&S FSP40 100142 9KHz ~ 40GHz Jan. 21, 2009 Radiation

(10CH01-CB)

1~6G CABLE WOKEN - 1003 1GHz~6GHz Mar. 26, 2009 Radiation

(10CH01-CB)

Pre-Amplifier Agilent 8449B 3008A02310 1GHz ~ 26.5GHz Jul. 04, 2008 Radiation (10CH01-CB)

Horn Antenna COM-POWE

R AH-118 071042 1GHz – 18GHz Nov. 11, 2008 Radiation (10CH01-CB)

Page 45: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

EMC TEST REPORT Report No. : EC941427

SPORTON International Inc. Page Number : 41 of 41 TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255

<EMS>

Instrument Manufacturer Model No. Serial No. Characteristics Calibration Date Remark

ESD Simulator EMTEST ESD 30 V06131013

08

Air:25KV,

Contact:25KV Feb. 20, 2009 ESD

Integrated

Measurement

System

R&S IMS 100002 9KHz ~ 3GHz Nov. 27, 2008 RS

Average Power

Sensor R&S NRP-Z91 100151 9KHz ~ 6GHz Nov. 27, 2008 RS

Electric Field

Sensor ETS-Lindgren HI-6005 00075211

100KHz ~ 5GHz, 0.5

~ 800V/M Nov. 27, 2008 RS

RF Power Amplifier AR 30S1G3 0323046 1GHz ~ 3GHz, 30W Nov. 27, 2008 RS

RF Power Amplifier AR 250W1000A 032320280MHz ~ 1GHz,

250W Nov. 27, 2008 RS

Log-Periodic

Antenna AR AT1080 0323130 80MHz ~ 1GHz NCR RS

Horn Antenna AR AT4002A 0323305 0.8GHz ~ 5GHz NCR RS

Dual Directional

Couplers AR DC 7144A 0322883 0.8GHz ~ 4.2GHz Nov. 27, 2008 RS

Dual Directional

Couplers AR DC 6180A 0322837 80MHz ~ 1GHz Nov. 27, 2008 RS

※ Calibration Interval of instruments listed above is one year.

Page 46: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

CE TEST REPORT REPORT NO. : EC941427

SPORTON International Inc. PAGE NUMBER : A1 OF A18

TEL : 886-2-2696-2468 ISSUED DATE : Apr. 21, 2009

FAX : 886-2-2696-2255

APPENDIX A. Photographs of EUT

Page 47: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

CE TEST REPORT REPORT NO. : EC941427

SPORTON International Inc. PAGE NUMBER : A2 OF A18

TEL : 886-2-2696-2468 ISSUED DATE : Apr. 21, 2009

FAX : 886-2-2696-2255

Page 48: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

CE TEST REPORT REPORT NO. : EC941427

SPORTON International Inc. PAGE NUMBER : A3 OF A18

TEL : 886-2-2696-2468 ISSUED DATE : Apr. 21, 2009

FAX : 886-2-2696-2255

Page 49: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

CE TEST REPORT REPORT NO. : EC941427

SPORTON International Inc. PAGE NUMBER : A4 OF A18

TEL : 886-2-2696-2468 ISSUED DATE : Apr. 21, 2009

FAX : 886-2-2696-2255

Page 50: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

CE TEST REPORT REPORT NO. : EC941427

SPORTON International Inc. PAGE NUMBER : A5 OF A18

TEL : 886-2-2696-2468 ISSUED DATE : Apr. 21, 2009

FAX : 886-2-2696-2255

Page 51: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

CE TEST REPORT REPORT NO. : EC941427

SPORTON International Inc. PAGE NUMBER : A6 OF A18

TEL : 886-2-2696-2468 ISSUED DATE : Apr. 21, 2009

FAX : 886-2-2696-2255

Page 52: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

CE TEST REPORT REPORT NO. : EC941427

SPORTON International Inc. PAGE NUMBER : A7 OF A18

TEL : 886-2-2696-2468 ISSUED DATE : Apr. 21, 2009

FAX : 886-2-2696-2255

Page 53: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

CE TEST REPORT REPORT NO. : EC941427

SPORTON International Inc. PAGE NUMBER : A8 OF A18

TEL : 886-2-2696-2468 ISSUED DATE : Apr. 21, 2009

FAX : 886-2-2696-2255

Page 54: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

CE TEST REPORT REPORT NO. : EC941427

SPORTON International Inc. PAGE NUMBER : A9 OF A18

TEL : 886-2-2696-2468 ISSUED DATE : Apr. 21, 2009

FAX : 886-2-2696-2255

Page 55: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

CE TEST REPORT REPORT NO. : EC941427

SPORTON International Inc. PAGE NUMBER : A10 OF A18

TEL : 886-2-2696-2468 ISSUED DATE : Apr. 21, 2009

FAX : 886-2-2696-2255

Page 56: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

CE TEST REPORT REPORT NO. : EC941427

SPORTON International Inc. PAGE NUMBER : A11 OF A18

TEL : 886-2-2696-2468 ISSUED DATE : Apr. 21, 2009

FAX : 886-2-2696-2255

Page 57: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

CE TEST REPORT REPORT NO. : EC941427

SPORTON International Inc. PAGE NUMBER : A12 OF A18

TEL : 886-2-2696-2468 ISSUED DATE : Apr. 21, 2009

FAX : 886-2-2696-2255

Page 58: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

CE TEST REPORT REPORT NO. : EC941427

SPORTON International Inc. PAGE NUMBER : A13 OF A18

TEL : 886-2-2696-2468 ISSUED DATE : Apr. 21, 2009

FAX : 886-2-2696-2255

Page 59: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

CE TEST REPORT REPORT NO. : EC941427

SPORTON International Inc. PAGE NUMBER : A14 OF A18

TEL : 886-2-2696-2468 ISSUED DATE : Apr. 21, 2009

FAX : 886-2-2696-2255

Page 60: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

CE TEST REPORT REPORT NO. : EC941427

SPORTON International Inc. PAGE NUMBER : A15 OF A18

TEL : 886-2-2696-2468 ISSUED DATE : Apr. 21, 2009

FAX : 886-2-2696-2255

Page 61: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

CE TEST REPORT REPORT NO. : EC941427

SPORTON International Inc. PAGE NUMBER : A16 OF A18

TEL : 886-2-2696-2468 ISSUED DATE : Apr. 21, 2009

FAX : 886-2-2696-2255

Page 62: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

CE TEST REPORT REPORT NO. : EC941427

SPORTON International Inc. PAGE NUMBER : A17 OF A18

TEL : 886-2-2696-2468 ISSUED DATE : Apr. 21, 2009

FAX : 886-2-2696-2255

Page 63: EC941427 Test Report - Logitech EMC...TEL : 886-2-2696-2468 Issued Date : Apr. 21, 2009 FAX : 886-2-2696-2255 History of this test report Original Report Issue Date: Apr. 21, 2009

CE TEST REPORT REPORT NO. : EC941427

SPORTON International Inc. PAGE NUMBER : A18 OF A18

TEL : 886-2-2696-2468 ISSUED DATE : Apr. 21, 2009

FAX : 886-2-2696-2255