ebis injector linac...ebis injector linac d. raparia mac review 2004/03/10-11 •lebt •rfq •mebt...

23
EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

Upload: others

Post on 24-Jan-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

EBIS Injector LinacD. Raparia

MAC Review 2004/03/10-11

•LEBT•RFQ•MEBT•LINAC•Injection into the Booster

D. Raparia 2004/3/10-11MAC Review

Page 2: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

AcknowledgmentsContributors:J. Alessi, E. Beebe, S. Pikin, A. Kponou, J. Ritter, C. Gardner, S. Y. Zhang, T. RoserB. Schlitt, U. Ratzinger

D. Raparia 2004/3/10-11MAC Review

Page 3: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

D. Raparia 2003/3/10-11MAC Review

4 m 3 m

RFQ: 8.5 - 300 keV/u; 100 MHz

IH Linac: 0.3 - 2.0 MeV/u; 100 MHz

Proposed Linac –Based RHIC Preinjector

LEBTMEBTHEBT

Ion U - P

q/m .16-1.0

Current 1.5 emA (for 1 turn inj)

Pulse LengthRep. RateDuty Factor

10 µs5 Hz0.005 %

Emittance 0.7 π mm rad (nor, 90%)

Energy Spread

0.7 keV/amu

Page 4: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

LEBT Requirements-Inject singly-charged ions into EBIS-Extract highly charged ions from EBIS-Diagnostics: Emittance Monitor, Current Monitor(2), TOF-Matching into RFQ

Twiss parameters at beginning and end of the LEBT

D. Raparia 2003/3/10-11MAC Review

Parameters Begin. of LEBT End of LEBT Units

α X -5.180 2.630

β X 9.136 0.1076 mm/mrad

ε X (4* rms,unnorm) 85.00 85.17 π mm mrad

α Y -5.180 2.630

β Y 9.136 0.1076 mm/mrad

ε Y (4* rms,unnorm) 85.00 85.17 π mm mrad

Page 5: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

LEBT with magnetic solenoid focusing is shown as the baseline. Designs with electrostatic focusing are also being considered.

D. Raparia 2003/3/10-11MAC Review

Page 6: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

LEBT Optics (Solenoid focusing)TRACE ouput

8.5 kG5 kG

D. Raparia 2003/3/10-11MAC Review

Page 7: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

RFQ Parameters-Proven technology, No risks-Could accelerate P - U

Parameters BNL CERN UnitsType

Q/m

Energy in

Energy out

Frequency

Max rep rate

Length

# of cells

Aperture

Voltage

E (surface)

RF Power

Acceptance

Input Emit.

Output Emit. (trans)

Output Emit. (longit)

Transmission

Bravery factor

4-rod4-rod

0.16-1.0

8.5

300

101.28

10

2.96

236

0.006

92

20.8

< 350

1.7

0.35

0.375

0.75

97

0.12

2.5

250

101.28

10

2.5

.0045

70

≤ 23

< 350

> 0.8

93

keV/amu

keV/amu

MHz

Hz

Meters

Meters

kV

MV/m

kW

π mm mrad (nor)

π mm mrad, nor, 90%

π mm mrad, nor, 90%

π MeV deg

1.8 ≤ 2

%

Kilpatrick

D. Raparia 2003/3/10-11MAC Review

(Present thinking – collaboration with Frankfurt on a 4-rod RFQ)

RFQ Transmission vs. Input Emittance

50

60

70

80

90

100

110

0 0.5 1 1.5 2

Input Emittance (norm, 90%, pi mm mrad)

Tran

smis

sion

(%)

Page 8: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

RFQ Beam Dynamics Design

PARMTEQ

Transmission:Au35+ 97% (2 mA)3He2+ 88 % (2 mA)

P 65 % (2 mA)

D. Raparia 2003/3/10-11MAC Review

Page 9: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

Requirements for MEBT-Matching from FODO (RFQ) to axial symmetric IH structure with triplets-Diagnostics: Current monitor(2) , Emittance

Twiss parameters at beginning and end of the MEBT

D. Raparia 2003/3/10-11MAC Review

Parameters End of RFQ Entrance of IH Units

α X 1.34 0.94β X 0.163 0.416 mm/mrad

ε X (5* rms,unnorm) 21.72 21.72 π mm mrad

α Y -1.06 0.703

β Y 0.134 0.644

ε Y (5* rms,unnorm) 21.72 21.72 π mm mrad

α Z 0.6800 -0.50806

β Z 0.0152 0.0056 deg/keV

ε Z (5* rms,unnorm) 32543 32543 π deg keV

Page 10: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

D. Raparia 2003/3/10-11MAC Review

Transport from RFQ to Linac(5 quads, 1 buncher)

10.000 mm X 50.000 mrad

30.000 Deg X 4000.00 keV

10.000 mm X 50.000 mrad

60.000 Deg X 4000.00 keV NP2= 13

20.00 mm (Horiz) 90.0 Deg (Long.)

20.00 mm (Vert)

NP1= 1

Length= 960.00mm

1

2 Q

3

4 Q

5

6 Q

7

8 G

9

10 Q

11

12 Q

13

H A= 1.3421 B= 0.16324 V A= -1.0636 B= 0.13391

Z A= 0.68000 B= 1.52000E-02

BEAM AT NEL1= 1 H A= 0.96881 B= 0.36918 V A= 0.92680 B= 0.72744

Z A=-0.50799 B= 5.62883E-03

BEAM AT NEL2= 13 I= 1.7mA W= 59.7000 59.7000 MeV

FREQ= 100.28MHz WL=2989.55mm EMITI= 21.720 21.320 32543.00 EMITO= 22.113 21.685 34196.18

N1= 1 N2= 13 PRINTOUT VALUES PP PE VALUE 1 2 -101.39000 1 4 59.51890 1 6 -38.43441 1 8 0.14700 1 10 34.95244 MATCHING TYPE = 8

DESIRED VALUES (BEAMF) alpha beta x 0.9400 0.4160 y 0.7030 0.6440 MATCH VARIABLES (NC=4) MPP MPE VALUE 1 4 59.51890 1 6 -38.43441 1 10 34.95244 1 12 -35.08996

CODE: TRACE3D v66L FILE: ebis_mebt.dat DATE: 03/01/2004 TIME: 11:06:42

Page 11: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

IH Linac

Main parameters of the IH linac Parameters BNL CERN Tank 1 Units

Q/m 0.16-1.0 0.12

Input energy 0.300 0.250 MeV/amu

Output Energy 2.0 1.87 MeV/amu

Frequency 101.28 101.28 Mhz

Max rep rate 10 10 Hz length 4.0 3.57 Meters

Input emittamce 0.55 pi mm mrad, norm,90%

Output emittance 0.61 pi mm mrad, norm,90%

Output energy spread 20.0 keV/amu

transmission 100 %

An IH Linac very similar to the first tank of the CERN Pb linac, is our baseline:,

(Present thinking – collaboration with GSI on an IH Linac)

D. Raparia 2003/3/10-11MAC Review

Page 12: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

D. Raparia 2004/3/10-11MAC Review

Page 13: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

IH linac optics codes LORAS used in this preliminary design

Transmission:

Au35+ 100% (2 mA)3He2+ 100% (2 mA)

Longitudinal profiles in the IH linac

Transverse profiles in the IH linac

D. Raparia 2004/3/10-11MAC Review

Page 14: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

IH Linac Input and Output Emittances

D. Raparia 2004/3/10-11MAC Review

Page 15: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

SCL Option-Allows acceleration to higher energies for higher q/m ions (> 6MeV/u for q/m=0.5) -Based on ATLAS, ALPI, ISAC-II and RIA technology-Two type of cavity β ~0.04(14) and 0.08 (10)

The ALPI resonator

Parameter Values UnitsQ/m 0.16-1.0Input energy 0.300 MeV/amuOutput Energy 2-7.5 MeV/amuFrequency 101.28 MHzMax rep rate 5 HzInput emittance 0.55 π mm mrad,

norm,90%Output emittance ~ 0.6 π mm mrad, norm,90%Transmission 100 %

-Accelerating Gradient 7MV/m-Energy gain 5MeV/charge/cryostat-Three cryostats to produce 15 MeV for the SCL

D. Raparia 2004/3/10-11MAC Review

Page 16: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

TRACE Simulation for SCL (Au)

4.000 mm X 15.000 mrad

5.000 Deg X 999.00 keV

4.000 mm X 15.000 mrad

5.000 Deg X 999.00 keV NP2= 78

5.00 mm (Horiz) 180.0 Deg (Long.)

5.00 mm (Vert)

NP1= 1

Length= 6308.40mm

1 2 G 3 4 G 5 6

7 SOL

8 9 10 G 11 12 G 13 14 15 G 16 17 G 18 19

20 SOL

21 22 23 G 24 25 G 26 27 28 G 29 30 G 31 32

33 SOL

34 35 36 G 37 38 G 39 40 41 G 42 43 G 44 45

46 SOL

47 48 49 G

50

51 G 52

53 54 G

55

56 G 57 58

59 SOL

60 61 62 G

63

64 G 65

66 67 G

68

69 G 70 71

72 SOL

73 74 75 G

76

77 G 78

H A= 0.0000 B= 0.30000 V A= 0.0000 B= 0.30000

Z A= 0.0000 B= 1.74800E-02

BEAM AT NEL1= 1 H A= 3.23052E-02 B= 0.88380 V A= 3.23052E-02 B= 0.88380

Z A= 0.90204 B= 2.67026E-03

BEAM AT NEL2= 78 I= 1.7mA W= 59.6543 507.8899 MeV

FREQ= 101.28MHz WL=2960.04mm EMITI= 14.000 14.000 43.70 EMITO= 6.368 6.368*********

N1= 1 N2= 78 PRINTOUT VALUES PP PE VALUE 1 2 0.41468 2 2 -33.00000 2 4 45.60000 2 6 0.00000 2 8 0.00000 1 11 3.00000 MATCHING TYPE = 0

CODE: TRACE3D v66L FILE: ebislin8.txt DATE: 02/27/2004 TIME: 14:36:26

D. Raparia 2004/3/10-11MAC Review

Page 17: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

Requirements for HEBT-Match beam transversely to Booster injection-Minimize energy spread at injection, dp/p = ±0.05%, -Provide ion charge state discrimination-Diagnostics: Current monitor (2), Multiwire/Faraday cup (3), Fast Faraday cup

Twiss parameters at beginning and end of the HEBT

Parameters End of IH Linac Entrance of Booster Units

α X 1.200 -1.7277

β X 2.1736 11.008 mm/mrad

ε X (5* rms,unnorm) 9.2 9.2 π mm mrad

α Y 0.28 0.82163

β Y 1.4397 4.8321 mm/mrad

ε Y (5* rms,unnorm) 9.2 9.2 π mm mrad

∆ E (for 5* rms ε Z ) ± 1 80 ± 145 keV

D. Raparia 2004/3/10-11MAC Review

Page 18: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

Layout in the Linac Lower Equipment Bay

D. Raparia 2004/3/10-11MAC Review

Page 19: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

Optics of the Transport line to the Booster

D. Raparia 2004/3/10-11MAC Review

25.000 mm X 10.000 mrad

90.000 Deg X 300.00 keV

25.000 mm X 10.000 mrad

90.000 Deg X 500.00 keV NP2= 86

84.00 mm (Horiz) 180.0 Deg (Long.)

84.00 mm (Vert)

NP1= 38

Length= 38443.63mm

38 39 Q 40 Q

41

42 Q 43 Q

44

45 Q 46 Q

47

48 Q 49 G

50

51 52 53 54 55 56 57 58 59 60 61

62

63 64

65

66 Q 67 Q

68

69 E

70 71 E 72 73 Q 74 75 Q 76 77 Q 78 79 E

80 81 E

82

83 84 85

86

H A= 1.0200 B= 2.1736 V A= 0.28000 B= 1.4397

Z A= -1.1333 B= 0.58470

BEAM AT NEL1= 38 H A= -1.7185 B= 11.057 V A= 0.81153 B= 4.7755

Z A= 0.20894 B= 0.42248

BEAM AT NEL2= 86 I= 1.7mA W= 407.6470 407.6470 MeV

FREQ= 100.28MHz WL=2989.55mm EMITI= 9.200 9.200 8175.66 EMITO= 9.325 9.200 8401.95

N1= 38 N2= 86 PRINTOUT VALUES PP PE VALUE 1 39 -1.00000 1 42 1.54272 1 45 -1.64882 1 48 1.31732 1 51 101.60000 1 54 0.00000 1 57 0.00000 1 60 0.00000 1 63 101.60000 1 66 -0.41975 1 73 -3.00000 1 75 3.00000 1 77 -2.00000 MATCHING TYPE = 8

DESIRED VALUES (BEAMF) alpha beta x -1.7272 11.0077 y 0.8216 4.8321 MATCH VARIABLES (NC=4) MPP MPE VALUE 1 42 1.54272 1 45 -1.64882 1 48 1.31732 1 66 -0.41975

CODE: TRACE3D v66L FILE: ebis_hebt_c7.t3d DATE: 03/08/2004 TIME: 09:39:00

Phi= 0.0deg, W=407.647MeV DP= 59.58deg, DW= 144.07keV, DZ= 32.93mm, DP/P= 0.177mrad, Ez= 5.70pi-mm-mrad

Page 20: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

Booster Injection-Transverse: -1-4 turn injection emittance in Booster is about 5.0 π mm

mrad, and incoherent tune spread is 0.08

-Longitudinal: -Simulation result shows EBIS injected will have emittance of ≤ 0.05 eV-s/u (present 0.05 eV-s/u)

-Longitudinal microwave instability: Keil-Schnell criteria requires dp/p >0.0012% which is satisfied by EBIS beam (dp/p = ±0.05%, )

D. Raparia 2004/3/10-11MAC Review

Page 21: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

Booster Injection

D. Raparia 2004/3/10-11MAC Review

0.5 1 1.5 2 2.5 3 3.5 4-21

-20

-19

-18

-17

-16

-15

MeV/u

Log

of c

ross

sec

tion,

cm

2

Electron Capture and Ionization Cross Sections, Au32+

Capture

Ionization

At 2 MeV/u, capture cross section reduced by factor of 40 relative to Tandem.

Mountain range of 4 EBIScapture schemes

Page 22: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

Emittance Budget for Linac

Energy(keV/u)

Current*

(mA)ε T (90%,,nor)( π mm mrad)

Comments

EBIS 8.5 1.75 0.35

RFQ 300 1.7 0.5

IH 2000 1.7 0.7 ∆ E= ±1 keV/u

Booster Injection 2000 1.7 0.7 ∆ E= ±0 .7 keV/u

* Current required for single turn injection into the Booster.

D. Raparia 2004/3/10-11MAC Review

Page 23: EBIS Injector Linac...EBIS Injector Linac D. Raparia MAC Review 2004/03/10-11 •LEBT •RFQ •MEBT •LINAC •Injection into the Booster D. Raparia 2004/3/10-11 MAC Review

CONCLUSION

Will use proven technologies for RFQ and IH (SC ?) structures.

This linac will satisfy all (transverse and longitudinal) requirements for Booster injection.

D. Raparia 2004/3/10-11MAC Review