eaton ehnanced - walker industrial

18
For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com V8-T5-9 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 For Customer Service in the U.S. call 1-877-ETN CARE (386-2273), in Canada call 1-800-268-3578. For Application Assistance in the U.S. and Canada call 1-800-426-9184. 5.1 Photoelectric Sensors Enhanced 50 Series Sensors Enhanced 50 Series Sensors Contents Description Page Enhanced 50 Series Sensors Product Selection Thru-Beam Sensors . . . . . . . . . . . . . . . . . . . V8-T5-10 Reflex Sensors . . . . . . . . . . . . . . . . . . . . . . V8-T5-12 Diffuse Sensors . . . . . . . . . . . . . . . . . . . . . . V8-T5-14 Clear Object Sensors . . . . . . . . . . . . . . . . . V8-T5-16 Fiber Optic Sensors . . . . . . . . . . . . . . . . . . . V8-T5-17 Compatible Connector Cables . . . . . . . . . . . V8-T5-19 Fiber Optic Cables . . . . . . . . . . . . . . . . . . . . V8-T5-20 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T5-21 Technical Data and Specifications . . . . . . . . . . V8-T5-21 Excess Gain . . . . . . . . . . . . . . . . . . . . . . . . . V8-T5-22 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . V8-T5-23 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T5-24 Enhanced 50 Series Sensors Product Description The new Enhanced versions of the 50 Series™ Photo- electric Sensors from Eaton’s electrical sector offer flexibility, durability and high optical performance in a cost- effective self-contained package. Choose from three output types, four time delay functions, six sensing modes and four connection styles to tailor the sensor to exactly meet your needs. Sensors are available in thru- beam, reflex, polarized reflex, diffuse reflective, clear object, and fiber optic sensing modes. Brackets are available for easy mounting and to allow precise adjustment of sensor alignment. Features High optical performance models including a 500 ft (152m) thru-beam and a 10 ft (3m) diffuse reflective unit Output options include a 3 Amp SPDT relay All units offer light/dark selection Logic options include ON-delay, OFF-delay, ON/OFF-delay and one- shot delay Fiber optic sensors operate in thru-beam or diffuse reflective mode depending on the fiber optic cable selected Fully potted construction for use in areas subject to washdown, high shock and/or vibration Choice of pre-wired power cable, built-in mini- connector, built-in micro- connector and pigtail micro-connector versions. Standard pre-wired cable length is 6 ft (2m) Variety of brackets available including ball swivel Standards and Certifications CSA Approved Certified to UL Standard, UL 508 DANGER THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safety- related use. This sensor product does not include self-checking redundant circuitry, and the failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage. For the most current information on this product, visit our Web site: www.eaton.com

Upload: others

Post on 06-Nov-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Eaton Ehnanced - Walker Industrial

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com V8-T5-9

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

For Customer Service in the U.S. call 1-877-ETN CARE (386-2273),in Canada call 1-800-268-3578.

For Application Assistance in the U.S. and Canadacall 1-800-426-9184.

5.1Photoelectric Sensors

Enhanced 50 Series Sensors

Enhanced 50 Series Sensors ContentsDescription Page

Enhanced 50 Series SensorsProduct Selection

Thru-Beam Sensors . . . . . . . . . . . . . . . . . . . V8-T5-10Reflex Sensors . . . . . . . . . . . . . . . . . . . . . . V8-T5-12Diffuse Sensors . . . . . . . . . . . . . . . . . . . . . . V8-T5-14Clear Object Sensors . . . . . . . . . . . . . . . . . V8-T5-16Fiber Optic Sensors . . . . . . . . . . . . . . . . . . . V8-T5-17Compatible Connector Cables . . . . . . . . . . . V8-T5-19Fiber Optic Cables . . . . . . . . . . . . . . . . . . . . V8-T5-20

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T5-21Technical Data and Specifications . . . . . . . . . . V8-T5-21

Excess Gain . . . . . . . . . . . . . . . . . . . . . . . . . V8-T5-22Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . V8-T5-23Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V8-T5-24

Enhanced 50 Series Sensors Product DescriptionThe new Enhanced versions of the 50 Series™ Photo-electric Sensors from Eaton’s electrical sector offer flexibility, durability and high optical performance in a cost-effective self-contained package. Choose from three output types, four time delay functions, six sensing modes and four connection styles to tailor the sensor to exactly meet your needs.

Sensors are available in thru-beam, reflex, polarized reflex, diffuse reflective, clear object, and fiber optic sensing modes. Brackets are available for easy mounting and to allow precise adjustment of sensor alignment.

Features● High optical performance

models including a 500 ft (152m) thru-beam and a 10 ft (3m) diffuse reflective unit

● Output options include a 3 Amp SPDT relay

● All units offer light/dark selection

● Logic options include ON-delay, OFF-delay, ON/OFF-delay and one-shot delay

● Fiber optic sensors operate in thru-beam or diffuse reflective mode depending on the fiber optic cable selected

● Fully potted construction for use in areas subject to washdown, high shock and/or vibration

● Choice of pre-wired power cable, built-in mini-connector, built-in micro-connector and pigtail micro-connector versions. Standard pre-wired cable length is 6 ft (2m)

● Variety of brackets available including ball swivel

Standards and Certifications● CSA Approved● Certified to UL Standard,

UL 508

DANGER

THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that, specifically no safety-related use. This sensor product does not include self-checking redundant circuitry, and the failure of this sensor product could cause either an energized or de-energized output condition, which could result in death, serious bodily injury, or property damage.

For the most current informationon this product, visit our Web site: www.eaton.com

Page 2: Eaton Ehnanced - Walker Industrial

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

V8-T5-10 Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5.1 Photoelectric Sensors

Enhanced 50 Series Sensors

Product Selection GuideConnection Options

Cable Version

Product Selection

Mini QD (Body)Micro or Euro (Micro) QD (Body)

Micro or Euro (Micro) QD (Pigtail)

Thru-Beam Sensors

Thru-Beam Standard Range 12

NotesSee listing of compatible connector cables on Page V8-T5-19.

1 For a complete system, order one sensor and one detector. 2 For brackets compatible with these sensors, see Accessories on Page V8-T5-21.

VoltageRange

SensingRange

OptimumRange

SensingBeam

Thru-BeamComponent Output Type

TimeDelay

ConnectionType Catalog Number

10–40 Vdc 200 ft(61m)

0.1 to 100 ft(0.03 to 31m)

Infrared Source N/A N/A 6 ft cable 1150E-6517

Detector NPN/PNP 250 mA no 1250E-6517

yes 1250E-8517

Source N/A N/A 4-pin Euro (micro) connector

1150E-6547

Detector NPN/PNP 250 mA no 1250E-6547

yes 1250E-8547

Source N/A N/A 4-pin Euro (micro) connector (pigtail)

1150E-6537

Detector NPN/PNP 250 mA no 1250E-6537

yes 1250E-8537

Source N/A N/A 4-pin mini-connector

1150E-6507

Detector NPN/PNP 250 mA no 1250E-6507

yes 1250E-8507

12–240 Vdc24–240 Vac

200 ft(61m)

0.1 to 100 ft(0.03 to 31m)

Infrared Source N/A N/A 6 ft cable 1150E-6513

Detector Isolated output solid-state relay300 mA at 240 Vac/Vdc

no 1250E-6513

yes 1250E-8513

SPDT EM relay3A at 120 Vac

no 1250E-6514

yes 1250E-8514

Source N/A N/A 4-pin micro-connector

1150E-6543

Detector Isolated output solid-state relay300 mA at 240 Vac/Vdc

no 1250E-6543

yes 1250E-8543

Source N/A N/A 4-pin micro-connector (pigtail)

1150E-6534

Detector Isolated output solid-state relay300 mA at 240 Vac/Vdc

no 1250E-6533

yes 1250E-8533

SPDT EM relay3A at 120 Vac

no 5-pin micro-connector (pigtail)

1250E-6534

yes 1250E-8534

Source N/A N/A 4-pin mini-connector

1150E-6504

Detector Isolated output solid-state relay300 mA at 240 Vac/Vdc

no 1250E-6503

yes 1250E-8503

SPDT EM relay3A at 120 Vac

no 5-pin mini-connector

1250E-6504

yes 1250E-8504

Field of View: 2.4°

Page 3: Eaton Ehnanced - Walker Industrial

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com V8-T5-11

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5.1Photoelectric Sensors

Enhanced 50 Series Sensors

Thru-Beam Extended Range 12

NotesSee listing of compatible connector cables on Page V8-T5-19.

1 For a complete system, order one sensor and one detector. 2 For brackets compatible with these sensors, see Accessories on Page V8-T5-21.

VoltageRange

SensingRange

OptimumRange

SensingBeam

Thru-BeamComponent Output Type

TimeDelay

ConnectionType Catalog Number

10–40 Vdc 500 ft(152m)

0.1 to 250 ft(0.03 to 77m)

Infrared Source N/A N/A 6 ft cable 1151E-6517

Detector NPN/PNP 250 mA no 1251E-6517

yes 1251E-8517

Source N/A N/A 4-pin Euro (micro) connector

1151E-6547

Detector NPN/PNP 250 mA no 1251E-6547

yes 1251E-8547

Source N/A N/A 4-pin Euro (micro) connector (pigtail)

1151E-6537

Detector NPN/PNP 250 mA no 1251E-6537

yes 1251E-8537

Source N/A N/A 4-pin mini-connector

1151E-6507

Detector NPN/PNP 250 mA no 1251E-6507

yes 1251E-8507

12–240 Vdc 24–240 Vac

500 ft(152m)

0.1 to 250 ft(0.03 to 77m)

Infrared Source N/A N/A 6 ft cable 1151E-6513

Detector Isolated output solid-state relay300 mA at 240 Vac/Vdc

no 1251E-6513

yes 1251E-8513

SPDT EM relay3A at 120 Vac

no 1251E-6514

yes 1251E-8514

Source N/A N/A 4-pin micro-connector

1151E-6543

Detector Isolated output solid-state relay300 mA at 240 Vac/Vdc

no 1251E-6543

yes 1251E-8543

Source N/A N/A 4-pin micro-connector (pigtail)

1151E-6534

Detector Isolated output solid-state relay300 mA at 240 Vac/Vdc

no 1251E-6533

yes 1251E-8533

SPDT EM relay3A at 120 Vac

no 5-pin micro-connector (pigtail)

1251E-6534

yes 1251E-8534

Source N/A N/A 4-pin mini-connector

1151E-6504

Detector Isolated output solid-state relay300 mA at 240 Vac/Vdc

no 1251E-6503

yes 1251E-8503

SPDT EM relay3A at 120 Vac

no 5-pin mini-connector

1251E-6504

yes 1251E-8504

Field of View: 2.4°

Page 4: Eaton Ehnanced - Walker Industrial

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

V8-T5-12 Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5.1 Photoelectric Sensors

Enhanced 50 Series Sensors

Reflex Sensors

Standard Reflex 12

NotesSee listing of compatible connector cables on Page V8-T5-19.

1 For a complete system, order one sensor and one retroreflector (see Tab 8, section 8.1).2 For brackets compatible with these sensors, see Accessories on Page V8-T5-21. 3 Ranges based on 3 in retroreflector for reflex sensors.

VoltageRange

SensingRange 3

OptimumRange 3

SensingBeam Output Type

TimeDelay

ConnectionType Catalog Number

10–40 Vdc 30 ft (9m) 0.5 to 15 ft(0.2 to 4.6m)

Visible red NPN/PNP 250 mA no 6 ft cable 1450E-6517

yes 1450E-8517

no 4-pin Euro (micro) connector

1450E-6547

yes 1450E-8547

no 4-pin Euro (micro) connector (pigtail)

1450E-6537

yes 1450E-8537

no 4-pin mini-connector 1450E-6507

yes 1450E-8507

12–240 Vdc 24–240 Vac

30 ft (9m) 0.5 to 15 ft(0.2 to 4.6m)

Visible red Isolated output solid-state relay300 mA at 240 Vac/Vdc

no 6 ft cable 1450E-6513

yes 1450E-8513

no 4-pin micro-connector 1450E-6543

yes 1450E-8543

no 4-pin micro- connector (pigtail)

1450E-6533

yes 1450E-8533

no 4-pin mini-connector 1450E-6503

yes 1450E-8503

SPDT EM relay3A at 120 Vac

no 6 ft cable 1450E-6514

yes 1450E-8514

no 5-pin micro- connector (pigtail)

1450E-6534

yes 1450E-8534

no 5-pin mini-connector 1450E-6504

yes 1450E-8504

Field of View: 1.0°

Page 5: Eaton Ehnanced - Walker Industrial

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com V8-T5-13

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5.1Photoelectric Sensors

Enhanced 50 Series Sensors

Polarized Reflex 123

NotesSee listing of compatible connector cables on Page V8-T5-19.

1 For a complete system, order one sensor and one retroreflector (see Tab 8, section 8.1).2 Polarized sensors may not operate with reflective tape. Test tape selection before installation.3 For brackets compatible with these sensors, see Accessories on Page V8-T5-21.4 Ranges based on 3 in retroreflector for reflex sensors.

VoltageRange

SensingRange 4

OptimumRange 4

SensingBeam Output Type

TimeDelay

ConnectionType Catalog Number

10–40 Vdc 16 ft (4.9m) 0.5 to 8 ft(0.2 to 2.5m)

Visible red NPN/PNP 250 mA no 6 ft cable 1451E-6517

yes 1451E-8517

no 4-pin Euro (micro) connector

1451E-6547

yes 1451E-8547

no 4-pin Euro (micro) connector (pigtail)

1451E-6537

yes 1451E-8537

no 4-pin mini-connector 1451E-6507

yes 1451E-8507

12–240 Vdc 24–240 Vac

16 ft (4.9m) 0.5 to 8 ft(0.2 to 2.5m)

Visible red Isolated output solid-state relay300 mA at 240 Vac/Vdc

no 6 ft cable 1451E-6513

yes 1451E-8513

no 4-pin micro-connector 1451E-6543

yes 1451E-8543

no 4-pin micro- connector (pigtail)

1451E-6533

yes 1451E-8533

no 4-pin mini-connector 1451E-6503

yes 1451E-8503

SPDT EM relay3A at 120 Vac

no 6 ft cable 1451E-6514

yes 1451E-8514

no 5-pin micro-connector (pigtail)

1451E-6534

yes 1451E-8534

no 5-pin mini-connector 1451E-6504

yes 1451E-8504

Field of View: 1.0°

Page 6: Eaton Ehnanced - Walker Industrial

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

V8-T5-14 Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5.1 Photoelectric Sensors

Enhanced 50 Series Sensors

Diffuse Sensors

Diffuse Reflective 1

NotesSee listing of compatible connector cables on Page V8-T5-19.

1 For brackets compatible with these sensors, see Accessories on Page V8-T5-21.2 Ranges based on 90% reflectance white card for diffuse reflective sensors.

VoltageRange

SensingRange 2

OptimumRange 2

SensingBeam Output Type

TimeDelay

ConnectionType Catalog Number

10–40 Vdc 5 ft (1.5m) 1 to 30 in(25 to 760 mm)

Infrared NPN/PNP 250 mA no 6 ft cable 1350E-6517

yes 1350E-8517

no 4-pin Euro (micro) connector

1350E-6547

yes 1350E-8547

no 4-pin Euro (micro) connector (pigtail)

1350E-6537

yes 1350E-8537

no 4-pin mini-connector 1350E-6507

yes 1350E-8507

12–240 Vdc 24–240 Vac

5 ft (1.5m) 1 to 30 in(25 to 760 mm)

Infrared Isolated output solid-state relay300 mA at 240 Vac/Vdc

no 6 ft cable 1350E-6513

yes 1350E-8513

no 4-pin micro-connector 1350E-6543

yes 1350E-8543

no 4-pin micro-connector (pigtail)

1350E-6533

yes 1350E-8533

no 4-pin mini-connector 1350E-6503

yes 1350E-8503

SPDT EM relay3A at 120 Vac

no 6 ft cable 1350E-6514

yes 1350E-8514

no 5-pin micro-connector (pigtail)

1350E-6534

yes 1350E-8534

no 5-pin mini-connector 1350E-6504

yes 1350E-8504

Field of View: 2.8°

Page 7: Eaton Ehnanced - Walker Industrial

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com V8-T5-15

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5.1Photoelectric Sensors

Enhanced 50 Series Sensors

Diffuse Reflective Extended Range 1

NotesSee listing of compatible connector cables on Page V8-T5-19.

1 For brackets compatible with these sensors, see Accessories on Page V8-T5-21.2 Ranges based on 90% reflectance white card for diffuse reflective sensors.

VoltageRange

SensingRange 2

OptimumRange 2

SensingBeam Output Type

TimeDelay

ConnectionType Catalog Number

10–40 Vdc 10 ft (3m) 1 to 60 in(25 to 1520 mm)

Infrared NPN/PNP 250 mA no 6 ft cable 1351E-6517

yes 1351E-8517

no 4-pin Euro (micro) connector

1351E-6547

yes 1351E-8547

no 4-pin Euro (micro) connector (pigtail)

1351E-6537

yes 1351E-8537

no 4-pin mini-connector 1351E-6507

yes 1351E-8507

12–240 Vdc 24–240 Vac

10 ft (3m) 1 to 60 in(25 to 1520 mm)

Infrared Isolated output solid-state relay300 mA at 240 Vac/Vdc

no 6 ft cable 1351E-6513

yes 1351E-8513

no 4-pin micro-connector 1351E-6543

yes 1351E-8543

no 4-pin micro-connector (pigtail)

1351E-6533

yes 1351E-8533

no 4-pin mini-connector 1351E-6503

yes 1351E-8503

SPDT EM relay3A at 120 Vac

no 6 ft cable 1351E-6514

yes 1351E-8514

no 5-pin micro-connector (pigtail)

1351E-6534

yes 1351E-8534

no 5-pin mini-connector 1351E-6504

yes 1351E-8504

Field of View: 2.8°

Page 8: Eaton Ehnanced - Walker Industrial

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

V8-T5-16 Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5.1 Photoelectric Sensors

Enhanced 50 Series Sensors

Clear Object Sensors

Clear Object Detector 12

NotesSee listing of compatible connector cables on Pages V8-T5-19 and V8-T5-20.

1 For a complete system, order one sensor and one retroreflector (see Tab 8, section 8.1). 2 For brackets compatible with these sensors, see Accessories on Page V8-T5-21.

VoltageRange

SensingRange

OptimumRange

SensingBeam Output Type

TimeDelay

ConnectionType Catalog Number

10–40 Vdc 45 in (1.2m) 1 to 24 in(25 to 610 mm)

Visible red NPN/PNP 250 mA no 6 ft cable 1452E-6517

yes 1452E-8517

no 4-pin Euro (micro) connector

1452E-6547

yes 1452E-8547

no 4-pin Euro (micro) connector (pigtail)

1452E-6537

yes 1452E-8537

no 4-pin mini-connector 1452E-6507

yes 1452E-8507

12–240 Vdc 24–240 Vac

45 in (1.2m) 1 to 24 in(25 to 610 mm)

Visible red Isolated output solid-state relay300 mA at 240 Vac/Vdc

no 6 ft cable 1452E-6513

yes 1452E-8513

no 4-pin micro-connector 1452E-6543

yes 1452E-8543

no 4-pin micro-connector (pigtail)

1452E-6533

yes 1452E-8533

no 4-pin mini-connector 1452E-6503

yes 1452E-8503

SPDT EM relay3A at 120 Vac

no 6 ft cable 1452E-6514

yes 1452E-8514

no 5-pin micro-connector (pigtail)

1452E-6534

yes 1452E-8534

no 5-pin mini-connector 1452E-6504

yes 1452E-8504

Field of View: 0.68°

Page 9: Eaton Ehnanced - Walker Industrial

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com V8-T5-17

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5.1Photoelectric Sensors

Enhanced 50 Series Sensors

Fiber Optic Sensors

Fiber Optic Infrared 1

NotesSee listing of compatible connector cables on Pages V8-T5-19 and V8-T5-20.

1 For brackets compatible with these sensors, see Accessories on Page V8-T5-21.2 Field of view depends on fiber selected. 3 For a complete system, order one sensor and one fiber optic cable (see Pages V8-T5-19 and V8-T5-20).4 Infrared fiber optic sensors are compatible with glass fiber optic cables (E51KE_).5 Diffuse mode—up to 6 in (152 mm); thru-beam—up to 35 in (890 mm).

VoltageRange

SensingRange

OptimumRange

SensingBeam Output Type

TimeDelay

ConnectionType Catalog Number

10–40 Vdc Depends on fiber selected 5

Depends on fiber selected

Infrared NPN/PNP 250 mA no 6 ft cable 1550E-6517

yes 1550E-8517

no 4-pin Euro (micro) connector

1550E-6547

yes 1550E-8547

no 4-pin Euro (micro) connector (pigtail)

1550E-6537

yes 1550E-8537

no 4-pin mini-connector 1550E-6507

yes 1550E-8507

12–240 Vdc 24–240 Vac

Depends on fiber selected 5

Depends on fiber selected

Infrared Isolated output solid-state relay300 mA at 240 Vac/Vdc

no 6 ft cable 1550E-6513

yes 1550E-8513

no 4-pin micro-connector 1550E-6543

yes 1550E-8543

no 4-pin micro-connector (pigtail)

1550E-6533

yes 1550E-8533

no 4-pin mini-connector 1550E-6503

yes 1550E-8503

SPDT EM relay3A at 120 Vac

no 6 ft cable 1550E-6514

yes 1550E-8514

no 5-pin micro-connector (pigtail)

1550E-6534

yes 1550E-8534

no 5-pin mini-connector 1550E-6504

yes 1550E-8504

Field of View: 234

Page 10: Eaton Ehnanced - Walker Industrial

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

V8-T5-18 Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5.1 Photoelectric Sensors

Enhanced 50 Series Sensors

Fiber Optic Visible 1

NotesSee listing of compatible connector cables on Page V8-T5-19.

1 For brackets compatible with these sensors, see Accessories on Page V8-T5-21.2 Field of view depends on fiber selected. 3 For a complete system, order one sensor and one fiber optic cable (see Page V8-T5-20).4 Visible fiber optic sensors are compatible with plastic fiber optic cables only. 5 Diffuse mode—up to 3 in (76 mm); thru-beam—up to 35 in (890 mm).

VoltageRange

SensingRange

OptimumRange

SensingBeam Output Type

TimeDelay

ConnectionType Catalog Number

10–40 Vdc Depends on fiber selected 5

Depends on fiber selected

Infrared NPN/PNP 250 mA no 6 ft cable 1551E-6517

yes 1551E-8517

no 4-pin Euro (micro) connector

1551E-6547

yes 1551E-8547

no 4-pin Euro (micro) connector (pigtail)

1551E-6537

yes 1551E-8537

no 4-pin mini-connector 1551E-6507

yes 1551E-8507

12–240 Vdc 24–240 Vac

Depends on fiber selected 5

Depends on fiber selected

Infrared Isolated output solid-state relay300 mA at 240 Vac/Vdc

no 6 ft cable 1551E-6513

yes 1551E-8513

no 4-pin micro-connector 1551E-6543

yes 1551E-8543

no 4-pin micro-connector (pigtail)

1551E-6533

yes 1551E-8533

no 4-pin mini-connector 1551E-6503

yes 1551E-8503

SPDT EM relay3A at 120 Vac

no 6 ft cable 1551E-6514

yes 1551E-8514

no 5-pin micro-connector (pigtail)

1551E-6534

yes 1551E-8534

no 5-pin mini-connector 1551E-6504

yes 1551E-8504

Field of View: 234

Page 11: Eaton Ehnanced - Walker Industrial

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com V8-T5-19

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5.1Photoelectric Sensors

Enhanced 50 Series Sensors

Compatible Connector Cables

Standard Cables—Micro 1

Standard Cables—Mini 1

Note1 For a full selection of connector cables, see Tab 10, section 10.1.

VoltageStyle

Numberof Pins Gauge Length

Pin Configuration/Wire Colors(Face View Female Shown)

PVC JacketCatalog Number

PUR JacketCatalog Number

IRR PUR JacketCatalog Number

Micro-Style, Straight Female

AC Micro 4-pin,4-wire

22 AWG 6 ft (2m) CSAS4F4CY2202 CSAS4F4RY2202 CSAS4F4IO2202

5-pin,5-wire

22 AWG 6 ft (2m) CSAS5A5CY2202 — —

DC 4-pin,4-wire

22 AWG 6 ft (2m) CSDS4A4CY2202 CSDS4A4RY2202 CSDS4A4IO2202

Current Rating at 600V

VoltageStyle

Numberof Pins Gauge Length

Pin Configuration/Wire Colors(Face View Female Shown) Catalog Number

Mini-Style, Straight Female

8A AC/DC 4-pin, 4-wire

16 AWG 6 ft (2m) CSMS4A4CY1602

5-pin, 5-wire

16 AWG 6 ft (2m) CSMS5A5CY1602

Micro-Style, Straight Female

2-Red/White3-Red4-Green

1-Red/Black

1-Brown2-White3-Black4-Gray5-Blue

1-Brown2-White3-Blue4-Black

Mini-Style, Straight Female

1-Black2-Blue3-Brown4-White

1-Black2-Blue3-Orange4-Brown5-White

Page 12: Eaton Ehnanced - Walker Industrial

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

V8-T5-20 Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5.1 Photoelectric Sensors

Enhanced 50 Series Sensors

Fiber Optic Cables

Glass Fiber Optic Cables

Glass Fiber Optic Cables—Duplex Cables (for Diffuse Reflective Sensing)

Glass Fiber Optic Cables—Single Cables (for Thru-Beam Sensing)

Plastic Fiber Optic Cables

Plastic Fiber Optic Cables—Pre-Assembled Duplex Cables

Plastic Fiber Optic Cables—Pre-Assembled Single Cables

Notes1 Larger diameter (1.5 mm) fibers provide approximately 50% longer sensing range than small diameter (1 mm).2 One cable.3 Set of two.

Fiber Bundle Size Ain In (mm)

Stainless Steel JacketCatalog Number

PVC/Monocoil JacketCatalog Number

Forward Viewing, Unthreaded

0.125 (3.2) E51KE713 E51KE313

Right Angle Viewing, Unthreaded

0.125 (3.2) E51KE733 E51KE333

Forward Viewing, Threaded Cable End

0.125 (3.2) E51KE723 E51KE323

Right Angle Viewing, Threaded Cable Shaft

0.125 (3.2) E51KE7A3 E51KE3A3

Right Angle Viewing, Threaded Cable End

0.125 (3.2) E51KE7B3 E51KE3B3

Dimensions, see Page V8-T5-25.

Sensing Tip Style

Forward Viewing, Unthreaded

Right Angle Viewing, Unthreaded

Forward Viewing, Threaded Cable End

Right Angle Viewing, Threaded Cable Shaft

Right Angle Viewing, Threaded Cable End

Fiber Bundle Size Ain In (mm)

Stainless Steel JacketCatalog Number

PVC/Monocoil JacketCatalog Number

Forward Viewing, Unthreaded

0.125 (3.2) E51KE813 E51KE413

Right Angle Viewing, Unthreaded

0.125 (3.2) E51KE833 E51KE433

Forward Viewing, Threaded Cable End

0.125 (3.2) E51KE823 E51KE423

Right Angle Viewing, Threaded Cable Shaft

0.125 (3.2) E51KE8A3 E51KE4A3

Right Angle Viewing, Threaded Cable End

0.125 (3.2) E51KE8B3 E51KE4B3

Dimensions, see Page V8-T5-25.

Sensing Tip Style

Forward Viewing, Unthreaded

Right Angle Viewing, Unthreaded

Forward Viewing, Threaded Cable End

Right Angle Viewing, Threaded Cable Shaft

Right Angle Viewing, Threaded Cable End

Fiber Diameter in In (mm) Catalog Number

Large Diameter, Threaded Tip

0.059 (1.5) 6324E-6501 12

Large Diameter, Threaded Tip with Bendable Probe

0.039 (1.0) 6324E-6502 2

Dimensions, see Page V8-T5-25.

Sensing Tip Style

Large Diameter, Threaded Tip

Large Diameter, Threaded Tip with Bendable Probe

Fiber Diameter in In (mm) Catalog Number

Large Diameter, Threaded Tip

0.059 (1.5) 6323E-6501 13

Large Diameter, Threaded Tip with Bendable Probe

0.039 (1.0) 6323E-6502 3

Dimensions, see Page V8-T5-25.

Sensing Tip Style

Large Diameter, Threaded Tip

Large Diameter, Threaded Tip with Bendable Probe

Page 13: Eaton Ehnanced - Walker Industrial

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com V8-T5-21

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5.1Photoelectric Sensors

Enhanced 50 Series Sensors

Accessories

Enhanced 50 Series Sensors

Technical Data and Specifications Enhanced 50 Series Sensors

Description Catalog Number

Mounting Bracket Right Angle—Short

Provides for full 360° rotation of sensor. Bracket slots allow for up to 1.5 in of vertical adjustment. Nickel plated

6150E-6501

Mounting Bracket Right Angle—Tall

Provides for full 360° rotation of sensor. Bracket slots allow for up to 1.5 in of vertical adjustment in each slot, and 3.5 in of overall positioning adjustment.

6150E-6502

Mounting Bracket Right Angle—Ball Swivel

Provides for full 360° rotation of sensor. Ball swivel allows for ±30° sensor angle. 6150E-6503

Retroreflectors

Retroreflectors and retroreflective tape, see Tab 8, section 8.1 —

Connector Cables

For use with connector version sensors, see Tab 10, section 10.1 —

Dimensions, see Page V8-T5-26.

Description

AC/DCEM Relay ModelSpecification

AC/DCSolid-state Relay ModelSpecification

DC OnlyStandard Range ModelSpecification

DC OnlyExtended Range ModelSpecification

Input voltage 12–240 Vdc; 24–240 Vac 12–240 Vdc; 24–240 Vac 10–40 Vdc 10–40 Vdc

Light/dark operation Switch selectable Switch selectable Switch selectable Switch selectable

Operating temperature –13° to 131°F (–25° to 55°C) –13° to 131°F (–25° to 55°C) –13° to 131°F (–25° to 55°C) –13° to 131°F (–25° to 55°C)

Humidity 95% Relative humidity, non-condensing 95% Relative humidity, non-condensing 95% Relative humidity, non-condensing 95% Relative humidity, non-condensing

Case material Fiberglass reinforced plastic Fiberglass reinforced plastic Fiberglass reinforced plastic Fiberglass reinforced plastic

Lens material Acrylic Acrylic Acrylic Acrylic

Vibration IEC 60947-5-2 part 7.4.2 IEC 60947-5-2 part 7.4.2 IEC 60947-5-2 part 7.4.2 IEC 60947-5-2 part 7.4.2

Shock IEC 60947-5-2 part 7.4.1 IEC 60947-5-2 part 7.4.1 IEC 60947-5-2 part 7.4.1 IEC 60947-5-2 part 7.4.1

Protection Output short circuit and overcurrent protection

Reverse polarity protection

Output short circuit and overcurrent protection

Reverse polarity protection

Output short circuit and overcurrent protection

Reverse polarity protection

Output short circuit and overcurrent protection

Reverse polarity protection

Enclosure ratings IP67, IP69K IP67, IP69K IP67, IP69K IP67, IP69K

Output load 3A at 120 Vac; 3A at 240 Vac3A at 28 Vac

300 mA at 240 Vac/Vdc 250 mA at 40 Vdc 250 mA at 40 Vdc

Response time 15 ms 2 ms 2 ms 2 ms

Timer timing response 0–15 sec. 0–15 sec. 0–15 sec. 0–15 sec.

No load current <30 mA <30 mA <30 mA <30 mA

Leakage current (max.) — 1 mA at 240 Vac <10 μA <10 μA

Indicator LEDs Green: output; yellow: power; red: alignment

Green: output; yellow: power; red: alignment

Green: output; yellow: power; red: alignment

Green: output; yellow: power; red: alignment

Emitter LED

Diffuse, infrared fiber optic, thru-beam models

Infrared 880 mm Infrared 880 mm Infrared 880 mm Infrared 880 mm

Reflex, polarized reflex, clear object, visible fiber optic units

Visible red 660 mm Visible red 660 mm Visible red 660 mm Visible red 660 mm

Mounting Bracket Right Angle—Short

Mounting Bracket Right Angle—Tall

Mounting Bracket Right Angle—Ball Swivel

Page 14: Eaton Ehnanced - Walker Industrial

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

V8-T5-22 Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5.1 Photoelectric Sensors

Enhanced 50 Series Sensors

Excess Gain

Thru-Beam

Thru-beam1. 1151E/1251E 2. 1150E/1250E

Diffuse Reflective

Diffuse reflective90% reflectance white card1. 1351E2. 1350E

Reflex

Reflex3 in retroreflector1. 1450E 2. 1451E

Clear Object Detector

Clear object detector3 in retroreflector1. 1452E

Fiber Optic Diffuse

Fiber optic diffuse0.125 in dia. glass fiber 0.040 in dia. plastic fiber1. 1550E 2. 1551E

Fiber Optic Thru-Beam

Fiber optic thru-beam0.125 in dia. glass fiber 0.040 in dia. plastic fiber1. 1550E 2. 1551E

10

1

1

0.3

10 1000

RANGE (feet)

RANGE (m)

EX

CE

SS

GA

IN 100

100030.5 5030.3

100

1

2

10

1

10.1

0.254

10 1000

RANGE (inches)

RANGE (cm)

EXCE

SS G

AIN

100

100025.4 045245.2

100

254

1

2 3

4

10

1

10.1

0.254

10 1000

RANGE (inches)

RANGE (cm)

EX

CE

SS

GA

IN 100

100025.4 045245.2

100

254

1

2

10

1

0.1

0.254

1 1000

RANGE (inches)

RANGE (cm)

EX

CE

SS

GA

IN

10025.4 254 045245.2

10 100

1

2

1

1

2.54

100

RANGE (inches)

RANGE (cm)

EX

CE

SS

GA

IN

104524.52

10

1

10

1

0.1

0.254

1 100

RANGE (inches)

RANGE (cm)

EX

CE

SS

GA

IN 100

100025.4 452 254045.2

10

12

10

1

0.1

0.254

1 100

RANGE (inches)

RANGE (cm)

EX

CE

SS

GA

IN 100

100025.4 452 254045.2

10

12

Page 15: Eaton Ehnanced - Walker Industrial

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com V8-T5-23

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5.1Photoelectric Sensors

Enhanced 50 Series Sensors

Wiring Diagrams Pin numbers are for reference, rely on pin location when wiring.

Enhanced 50 Series Sensors

Notes1 Connecting the test input to 0 Vdc allows you to switch the light source off for troubleshooting while leaving the sensor under power. 2 Over current protection is to be provided in the field. Conductor size for 20 AWG: 5 amp; 22 AWG: 3 amp; 24 AWG: 2 amp.3 Connect load to appropriate output for either sinking or sourcing operation.

Operating Voltage Cable Model

Mini-Connector Model(Face View Male Shown)

Micro-Connector Model(Face View Male Shown)

Thru-Beam Source

10–40 Vdc

All Others

10–40 Vdc

Thru-Beam Source

12–240 Vdc or 24–240 Vacsolid-state relay 2

All Others with Isolated AC/DC Output

12–240 Vdc or 24–240 Vacsolid-state relay 2

Thru-Beam Source

12–240 Vdc or 24–240 VacSPDT EM relay 2

All Others

12–240 Vdc or 24–240 VacSPDT EM relay 2

BU

BR

BK

Test In

(+)

(–) OV

1

Test In

(–) OV

(+)Test In

(–) OV

(+)

BU

WH NPN

PNP (–) OV

BK

BN (+)

Load

Load

(+)

(–) OV

PNP

NPNLoad

Load

(+)

(–) OV

PNP

NPNLoad

Load

BU

BR L1 (+)

L2 (–)

L2 (–)

L1 (+) L1 (+)

L2 (–)

BUBK

WH

BR L1 (+)

L2 (–)

IsolatedAC/DC Output

3 L2 (–)L1 (+)

IsolatedAC/DC Output

3

L1 (+)L2 (–)Isolated

AC/DCOutput

3

BU

BR L1 (+)

L2 (–)

L2 (–)

L1 (+) L1 (+)

L2 (–)

BU

OR

BK

BR

WH N.C.COM

N.O.L2 (–)

L1 (+) L1 (+)

COM

N.O. N.C.

L2 (–)

L1 (+)

L2 (–)

COM

N.O. N.C.

Page 16: Eaton Ehnanced - Walker Industrial

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

V8-T5-24 Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5.1 Photoelectric Sensors

Enhanced 50 Series Sensors

DimensionsApproximate Dimensions in Inches (mm)

Enhanced 50 Series Sensors

Cable and Pigtail Connector Versions

Clear Object Versions

Mini-Connector Versions

AC/DC Micro or Euro (Micro) Connector Versions

Top Views

With Timing Without Timing

2.87(73)

1.81(46)

0.59(15)

1.42(36)

1.91(48.5)

0.26 (6.5)Dia.

0.21 (5.2) x 0.32 (8.1)Slot – 2 Places

0.31(8)

0.16(4)

2.87(73)

1.81(46)

1.42(36)

3.13(79.5)

D.O L.O

SENS

MIN MAX

2.89(73)

3.13(79.5)

1.50(38)

0.31(8)

0.16(4)

2.87(73)

1.81(46)

0.59 (15)

0.70(17.78)

1.42(36)

1.91(48.5)

0.21 (5.2) x 0.32 (8.1)Slot – 2 Places

0.31(8)

0.16(4)

2.87(73)

1.81(46)

0.59 (15)

0.55(13.97)

1.42(36)

1.91(48.5)

0.21 (5.2) x 0.32 (8.1)Slot – 2 Places

0.31(8)

0.16(4)

T/D L L

ONESHOT

SOUT

S

ON OFFD.O L.O

DELAY OFF

DELAY ON

0 15 Sec

0 15 Sec

SENSMIN MAX

Red:Alignment

Yellow:Power

D.O L.O

SENS

MIN MAX

Green:Output

Red:Alignment

Yellow:Power

Green:Output

Page 17: Eaton Ehnanced - Walker Industrial

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com V8-T5-25

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5.1Photoelectric Sensors

Enhanced 50 Series Sensors

Approximate Dimensions in Inches (mm)

Glass Fiber Optic Cables—Duplex Cables Stainless Steel Jacket shown for all.

Collar Mounting End

Forward Viewing, Unthreaded

Right Angle Viewing, Unthreaded

Forward Viewing, Threaded Cable End

Right Angle Viewing, Threaded Cable Shaft

Right Angle Viewing, Threaded Cable End

Glass Fiber Optic Cables—Single CablesStainless Steel Jacket shown for all.

Collar Mounting End

Forward Viewing, Unthreaded

Right Angle Viewing, Unthreaded

Forward Viewing, Threaded Cable End

Right Angle Viewing, Threaded Cable Shaft

Right Angle Viewing, Threaded Cable End

36(914)

øA

0.187 (4.7)

7.5(190)

0.50 (13)

0.50(13)

0.187 (4.7)

36(914)

øA

0.82 (21)

0.187(4.7)

7.5(190)

R 0.50 (13)

1.00(25)

0.50(13)

0.187 (4.7)

36(914)

5/16-24 UNF-2ATHD

7.5(190)

1.50(38)

øA

0.50(13)

0.187 (4.7)

36(914)

0.82(21)

5/16-24 UNF-2ATHD

7.5(190)

R 0.50 (13)

1.00(25)

1.50(38)

øA

0.187(4.7)0.50

(13)

0.187 (4.7)

36(914)

øA

0.82 (21)

5/16-24 UNF-2A THD

7.5(190)

R 0.50 (13)

1.00(25)

0.50(13)

1.50 (38)

0.187 (4.7)

36(914)

øA

0.187 (4.7)

0.50 (13)0.187 (4.7)

0.50 (13)

36(914)

øA

0.82 (21)

0.187(4.7)

R 0.50 (13)

1.00(25)0.187 (4.7)

0.50 (13)

36(914)

5/16-24 UNF-2ATHD

1.50(38)

øA

0.187 (4.7)

0.50 (13)

36(914)

0.82 (21)5/16-24 UNF-2ATHD

R 0.50 (13)

1.00(25)

1.50(38)

øA

0.187(4.7)

0.187 (4.7)

0.50 (13)

36(914)

øA

0.82 (21)

5/16-24 UNF-2ATHD

R 0.50 (13)

1.00(25)

1.50 (38)

0.187 (4.7)

0.50 (13)

Page 18: Eaton Ehnanced - Walker Industrial

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

V8-T5-26 Volume 8—Sensing Solutions CA08100010E—March 2012 www.eaton.com

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5.1 Photoelectric Sensors

Enhanced 50 Series Sensors

Approximate Dimensions in Inches (mm)

Plastic Fiber Optic Cables—Pre-Assembled Duplex Cables

Large Diameter, Threaded Tip

Large Diameter, Threaded Tip with Bendable Probe

Plastic Fiber Optic Cables—Pre-Assembled Single Cables

Large Diameter, Threaded Tip

Large Diameter, Threaded Tip with Bendable Probe

Accessories

Mounting Bracket Right Angle—Short

Mounting Bracket Right Angle—Tall

Mounting Bracket Right Angle—Ball Swivel

0.087 (2.2) Dia.

78 (2000) 0.059(1.5) Fiber Dia. X2

0.575(14.6)

M6X0.75

0.087 (2.2) Dia.

78 (2000) 0.039(1.0) Fiber Dia. X2

M6X0.75

0.590(15)

3.54(90.0)

0.100 (2.5) Dia.0.14 (3.6)

0.200 (5.1)

0.059(1.5) Fiber Dia. X2

0.087 (2.2) Dia.0.57

(14.5)78 (2000)

M4X0.70.20 (5.0)

0.039(1.0) Fiber Dia. X2

M4X0.7

0.087 (2.2) Dia.

78 (2000)

0.068 (1.6) Dia.

0.47(12)

3.54(90.0)

0.2 (5)

2.65(67.3)

1.25(31.8)

1.25(31.8)

1.90(48.3)

0.75(19.0)

2.37(60.2)

0.28 (7.1)2.00 (50.8)

0.28(7.1)

1.20(30.5)Dia.

1.20 (30.5) Dia.2.00 (50.8) Dia.

2.80(71.1)

0.08(2.0)

90°

90°45°

0.28(7.1)

1.43(36.3)

3.05(77.5)

0.75(19.0)

1.20(30.5)Dia.

2.00 (50.8)

4.7(119.4)

2.65(67.3 )

1.25(31.8)

0.08(2.0)

90°

0.30 (7.6)2.80 (71.1)

2.60(66.0)

0.50(12.7)

1.10(27.9) Thread

M30 x 0.06 (1.5)0.80 (20.3)

1.13 (28.6)

90°2.00(50.8)

1.15(29.2)