Page 1: Earthing & Lightning 2Comparison between GI strips and CCS- same Exothermic Welding ... • Life is 4 to 5 times more than GI strip/flats • Cost-effective replacement of solid copper

JMV LPS LIMITEDLeading the Nation towards Electrical Safetywww.jmv.co.in

Protection System

EARTHINLIGHTNING&

Page 2: Earthing & Lightning 2Comparison between GI strips and CCS- same Exothermic Welding ... • Life is 4 to 5 times more than GI strip/flats • Cost-effective replacement of solid copper

G About Us

Since 2003, JMV LPS Limited is a pioneering technology leader that provides reliable protection of people, buildings, electrical/electronic devices and systems against an adverse effect of lightning, surges and fault current complying National & International standards. During the intervening era of immense commercial and technological advancements, JMV LPS Limited has progressed, becoming a world leader in Design, Manufacture, Supply and Installation of Earthing & Lightning Protection System. We are an ISO 9001:2008 certified organization along with ISO 14001:2004 and OHSAS 18001:2007 certifications. We focus at implementing things with accuracy for the installation to be effective and everlasting. Expedite excellence in innovation, quality and customer service is the key to our steady growth in electrical industry.

Page 3: Earthing & Lightning 2Comparison between GI strips and CCS- same Exothermic Welding ... • Life is 4 to 5 times more than GI strip/flats • Cost-effective replacement of solid copper

Content

Earthing Systemlightning protection

Copper Bonded Rod 040506060707080809

131414

Copper Clad Steel Conductor

Comparison between GI strips and CCS- same

Exothermic Welding

Required Components for making Exothermic Joints

Exothermic Weld Joints V/S Mechanical Joints

Earth Enhancement Compound

Compact Earthing Kit

Earthing Pit Covers & Accessories

Lightning Protection System As Per IS/IEC 62305

Down Conductors

Connecting Accessories for LPS Installation

15 Lightning Protection System As Per NF C 17-102

Page 4: Earthing & Lightning 2Comparison between GI strips and CCS- same Exothermic Welding ... • Life is 4 to 5 times more than GI strip/flats • Cost-effective replacement of solid copper

Earthing SystemElectrical Earthing is one of the remarkable lifesaving discovery. Any electrical system devoid of connection to earth can have destructive consequences and may risk the life of people and property on the globe. A well-designed earthing system is mandatory as it also servers the Lightning Protection System in suppressing the harmful lightning surges. All the appliances must be grounded to ensure that any excessive current is directly passed into the ground.

The Copper Bonded ground rod is manufactured by an electrolytic process of 99.99% pure electrolytic copper coating of 250 microns thickness on low carbon, high tensile steel rod. This concoction contributes to the strength and conductivity of the whole system. This precisely tested and quality engineered product is widely accepted and recommended owing to its longevity and outstanding performance. JMV’s Copper Bonded Rod obeys IEC 62561-2, IEEE 80, UL 467, IS 3043 & NBC 2016. Moreover, CBR is UL Tested and Approved. The Rods can be accessed in standard diameter of 14.2mm, 17.2mm, 23.2 mm with standard length of 10 feet.

Technical Features:• Manufacturing parameters are successfully certified with UL 467 AND CPRI.• Sturdiness and concentrated toughness of the coupling threads gratify the integrity of molecularly bonded copper rods. • Noticeable tensile strength of 527.3 kg/cm2.• Molecularly bonded steel and copper engross 0% peeling when driven into earth. • Easy installation with lifespan of more than 40 years.• Best Earthing Conductor with remarkable aftermath and a theft-free solution.• Incorporates less number of joints.• Cost effective replacement of solid copper conductor. • Installation period is 40% of the traditional earthing installation.

Copper Bonded Rod:

EarthEnhancement Compound

ExothermicWeld Connection

CopperBonded Rod

Pit Cover

EarthEnhancement Compound

Clamp

CopperBonded Rod

Pit Cover

Maintenance Free Earthing System withExothermically Welded Bus Bar

Maintenance Free Earthing System withClamp Connection

4

Page 5: Earthing & Lightning 2Comparison between GI strips and CCS- same Exothermic Welding ... • Life is 4 to 5 times more than GI strip/flats • Cost-effective replacement of solid copper

The National Electrical Grounding Research Project (NEGRP) Conducted by the National Fire Protection Association (NFPA) Research Foundation depicts 40+ years performance of Copper Bonded Earthing Rod.

The copper clad steel conductor is made up of steel with an even coating of 99.99% pure copper. It is a cost effective and theft proof alternative for pure copper conductor. Equipped with strength of steel and the superior conductivity of copper, this concentric copper cladding is a metallurgical bonding that yields a composite electrical conductivity of 21%, 30% and 40% IACS and is available in Annealed and Hard Drawn. This homogeneous copper cladding can be single or multiple stranded based on the fault current carrying capacity. It is highly reliable, non-rusting and an effective solution which paves a low impedance path to the earth. It can withstand more mechanical abuses and is less prone to vibration-induced fatigue than solid copper or aluminium wire. Unlike GI, Copper Clad Steel Conductor possesses longer life-span and due to lesser joints, copper clad wires & strands sound more cost effective.

Technical Features:• Complying IEEE 80, ASTM B 869-96 and ASTM B 452-93 standard• Remarkable fault current carrying capacity• The product inherent corrosion - resistant properties maintaining high - tensile strength.• Low scrap value hence discouraging theft• Superior mechanical strength and flexibility• Life is 4 to 5 times more than GI strip/flats• Cost-effective replacement of solid copper conductor/GI strips

Copper Clad Steel Conductor:

5

Page 6: Earthing & Lightning 2Comparison between GI strips and CCS- same Exothermic Welding ... • Life is 4 to 5 times more than GI strip/flats • Cost-effective replacement of solid copper

Comparison between GI strips and CCS- same:

Exothermic weld system incorporates molecular and exothermic reaction between metal & oxide with the idea of creating strong joints and permanent connections. JAMWELD provides joints that possess both chemical as well as physical interaction. The joints unquestionably inked firmly in molecular bonding such that it doesn’t loosen or deteriorates with age.

Technical Features:• The molecular bonding provides integrity to the joints.• Protection against humid and corrosive environments.• Remarkable electrical continuity.• The connections do not get affected by ageing.• The system is highly portable and does not require any external power source to make joints.• Connections can withstand repeated surges.

Exothermic Welding:

6

Page 7: Earthing & Lightning 2Comparison between GI strips and CCS- same Exothermic Welding ... • Life is 4 to 5 times more than GI strip/flats • Cost-effective replacement of solid copper

Required Components for making Exothermic Joints:

Exothermic Weld Joints V/S Mechanical Joints:

FLINT GUN

JAMWELD POWDER

GRAPHITE MOLD

STEEL DISC

CONDUCTOR

7

Page 8: Earthing & Lightning 2Comparison between GI strips and CCS- same Exothermic Welding ... • Life is 4 to 5 times more than GI strip/flats • Cost-effective replacement of solid copper

Earth Enhancement Compound:

With an extensive experience in the grounding & bonding system, JMV has developed a compact solution for smaller applications and for Photovoltaic systems named as- “Super Earthing Kit” and “Solar Earthing Kit”. These kits comprises of solid rod of steel along with carbon based earth enhancement compound to improve conductivity in every soil condition with a pre-welded bus bar jointed exothermically to make connection with strip/conductor. These kits are available in 14.2mm diameter, 4 feet length and customization is possible as per the site or client requirement.

Technical Features:• A solid rod made up of steel with minimum 250 microns pure copper coating• Coating of 99.99% pure copper ensures better Electrical Conductivity• Excellent fault current carrying capacity- 5kA for Super Earthing Kit 18kA for Solar Earthing Kit• Copper Coating withstand high corrosion resistant • Offers long life upto 30 years• Cost Effective Solution• Easy Installation

IEEE 80 and NBC-2016 states that, multiple rods even in large numbers, may sometime fail to produce an adequately low resistance to earth. In order to reduce the soil resistivity, artificial soil treatment shall be adopted. RoHS compliant Earth Enhancement Compound contains 95% carbon content which makes it highly conductive material designed to lower grounding system resistance and improves grounding effectiveness in high resistivity soil conditions. It can be easily used in sites installed in areas with poor soil conductivity (such as rocky, sandy soil etc). It maintains constant soil resistance even in the driest season.JMv’s optimum quality earth enhancing compound complies IEC 62561-7 standard which sets the basic norms for the various tests like leaching test, sulphur test, resistivity test and the corrosion test.

Technical Features:• Recommended by IEEE 80, NBC 2016, IEC 62561-7• 95% pure carbon content• Remarkable conductivity even in the dry form• Offers an effective earth resistance in areas of high soil resistivity• Does not leaches out with time offering corrosion free system• No need to have scheduled or routine maintenance• Retains moisture for longer span• Easy to handle as it comes in 10kg and 25 kg bags• Chemically inert and pollution free compound

Compact Earthing Kits:

Super Earthing Kit Solar Earthing Kit

8

Page 9: Earthing & Lightning 2Comparison between GI strips and CCS- same Exothermic Welding ... • Life is 4 to 5 times more than GI strip/flats • Cost-effective replacement of solid copper

Earthing Pit Covers & Accessories:Earth Pit Cover is a uniquely designed effective merchandise used to secure the whole earthing installation. This lightweight product provided over the earthing can be easily installed or removed in the long run in case of any inspection or reconstruction is to be done. It is waterproof and can be made of PVC, FRP or DMC ensuring long running life & UV stabilized characteristics.

Connecting Accessories:

9

Page 10: Earthing & Lightning 2Comparison between GI strips and CCS- same Exothermic Welding ... • Life is 4 to 5 times more than GI strip/flats • Cost-effective replacement of solid copper

Lightning Protection SystemAccording to NBC 2016, “There are no devices or methods capable of modifying the natural weather phenomenon to the extent that they can prevent lightning discharges. Lightning flashes to, nearby structures or lines connected to the structures are hazardous to people, to the structures themselves, their contents and installations as well as to lines” as shown in fig. below-

Risk Assessment as per IS/IEC 62305, NBC 2016 & NFC 17-102Based on lightning strikes directly on structures, nearby structures, on service or nearby service can cause various types of losses as mentioned:

Failure ofElectrical and

Electronicsequipment.

Damages

Physicaldamage

Loss of human life

Loss of services

Loss of cultural heritage

Loss of economic value

Injury toliving beingby electric

shock

Sources of Lightning:Direct lightning on the structureIndirect lightning near by structure

Indirect lightning near by incoming lineDirect lightning on the incoming line

Incoming data/telecom lineIncoming power line

Internal lightning protection system (SPDs)

Main earthing bar (MEB) for equipotential bondingEarth termination system

SERVER ROOM

MainLT

Panel

2

5

4

1

S1

S3

S2

S1

S2

S3

S4

2

1

3

4

5

External lightning protection system6

S43

6

10

Page 11: Earthing & Lightning 2Comparison between GI strips and CCS- same Exothermic Welding ... • Life is 4 to 5 times more than GI strip/flats • Cost-effective replacement of solid copper

Considering the devastating effects of External Lightning, JMV is proposing a well designed & calculated Lightning Protection Solution based on the type of structure, location, occupancy, risk of explosion, electrical and electronic equipment/ components that are sensitive to direct hit of lightning. The entire designing structure of lightning protection depends upon detailed Risk Analysis as given below:

Typical Values of tolerable risk RT:

Types of loss RT (y-1)

L1 Loss of human life or permanent injuries 10-5

L2 Loss of service to the public 10-3

L3 Loss of cultural heritage 10-4

L4 Economic Loss 10-3

Identify the structure to be protected

Identify the types of loss relevant to the structure

For each type of loss, Identify and calculate the risk componentsRA, RB, RC, RM, RU, RV, RW, RZ

R > RTNO

Structure protected

Protection needed

Is LPSInstalled ?

RA + RB + RU +RV > RT a

YES

YES

YES

Are SPMInstalled ?

YES

NO NO

NO

Install an adequatetype of LPS

Install an adequateSPM

Install other protectionmeasures

Calculate new values ofrisk components

If RA + RB < RT

11

Page 12: Earthing & Lightning 2Comparison between GI strips and CCS- same Exothermic Welding ... • Life is 4 to 5 times more than GI strip/flats • Cost-effective replacement of solid copper

In order to ease the risk assessment, JMV has developed software named Lightning Risk Assessment Calculator. This calculator is designed in compliance with IS/IEC 62305 and NBC 2016. With this software one can ensure whether his structure is protected without lightning protection system. If not then at what level of protection (LEVEL I-IV), the structure will be protected.

NOTE: *Find Lightning Risk Assessment software on our webiste / or download Lightning Risk Assessment Mobile Application directly from Google Playstore.

Direct Link toRisk Assessment App

12

Page 13: Earthing & Lightning 2Comparison between GI strips and CCS- same Exothermic Welding ... • Life is 4 to 5 times more than GI strip/flats • Cost-effective replacement of solid copper

Lightning Protection System As Per IS/IEC 62305:Complying Standards IEC 62561, NFPA 780, NBC 2016 As per IS/IEC 62305 and NBC-2016, Lightning Protection System is a combination of external lightning protection & Internal lightning protection also known as Surge Protection Measures which shall be installed to avoid damages to the structures, accidents, severe injuries and even deaths of humans due to direct or indirect strikes of lightning.

External Lightning Protection components includes:1. Air Terminal is install to Intercept a lightning flash to the structure 2. Down Conductor is install to direct the devastating lightning current safely towards earth3. Earth Termination System to dissipate that current into the earth

Air Termination NetworkAs per IS/IEC 62305, Air termination components shall be installed at corners, exposed points and edges in accordance with one or more of the following methods of positioning. It is available in Aluminium, Copper, Copper Clad Aluminium & Copper Clad Steel as per standard specifications.

- Protection Angle Method (Vertical Rods offering certain angles ofprotection based on LPL)

- Rolling Sphere Method (Catenary Wires)

- Mesh Method (Horizontal Conductor in Meshed or Grid Form)

as per the graph

i ii iii iv

Class ofLPS

h

80

70

60

50

40

30

20

10

00 2 10 20 30 40 50 60

13

Page 14: Earthing & Lightning 2Comparison between GI strips and CCS- same Exothermic Welding ... • Life is 4 to 5 times more than GI strip/flats • Cost-effective replacement of solid copper

Down Conductors:

Connecting Accessories for LPS Installation:

As per IS/IEC 62305, Down conductors shall be preferably placed at the external part of the structure. In order to reduce the probability of damage due to lightning current flowing in the LPS, the down-conductors shall be installed straight and vertical such that they provide the shortestand most direct path to earth. The formation of loops shall be avoided. It is available in Aluminium, Copper, Copper Clad Aluminium & Copper Clad Steel as per standard specifications.

1

2 34

5

6

10

11

89

7

1 - Lightning Rod 2 - Roof Cable Holder 3 - Expansion Piece

4 - Round Down Conductor 5 - Cable Holder 6 - Rod Holder

7 - Testlink 8 - Pit Cover 9 - Ground enhancing Compound

10 - Earth Rod 11 - Solar Panel

Typical values of the distance between down-conductorsas per NBC 2016 complying IS/IEC 62305

Class of LPS Typical Distances m10101520

IIIIIIIV

14

Page 15: Earthing & Lightning 2Comparison between GI strips and CCS- same Exothermic Welding ... • Life is 4 to 5 times more than GI strip/flats • Cost-effective replacement of solid copper

Eseat(1)

Insulator(2)

Mast(3)

Down Conductor

(4)

Lightning StrikeCounter (5)

Test Link

(6)

Pit Cover

(7)

Earthing Rod Clamps /Exothermic Welding

(8)

Ground EnhancingCompound

(9)

12

3

4

5

6

78

9

Lightning Protection System As Per NF C 17-102:Complying Standards NF C 17-102, UNE 21186 An ESE Lightning protection is a highly advance technique to safeguard any high rise structure against direct lightning. This is an active device solution fabricated with latest technology and proven techniques As per NF C 17-102. An ESE air terminal offers a wide range of radius of protection. ESE lightning air terminals are placed on highest part of the structure and connected to a lightning conductor and safely conduct the lightning current to the ground.

• ION STREAMER- A Non-Electronic Air TerminalA non-electronic air terminal based on Corona discharge technology uses the naturally occurring electrical field to complete the timely release of an upward streamer. During thunderstorm conditions when the lightning down leader is approaching ground level, an upward leader may be created by any surface. An initiation time of an upward leader is greatly reduced and an ION Streamer generates controlled magnitude and frequency pulses at the tip of the terminal during high static fields prior to a lightning .

• Features & Advantages- Made up of Stainless Steel central capture head of 316 L, a corrosion resistant material.- Generation of streamer through Corona Effect.- Advance technology offering more coverage area with single installation.- Area of coverage in radius 107 mtr. (approx.) at 5 meter Mast Height.- Easy in Installation & aesthetic friendly.- Minimizes total project cost & time.

15

Page 16: Earthing & Lightning 2Comparison between GI strips and CCS- same Exothermic Welding ... • Life is 4 to 5 times more than GI strip/flats • Cost-effective replacement of solid copper

JMV LPS LTD.

Follow Us

twitter.com/jmvlpslimitedfacebook.com/jmvlpsltd

youtube.com/c/JMVLPSLimitedindia linkedin.com.in/jmvlpsltd

W 50, Sector 11, Noida 201301, India

+91-0120-4590000 +91-0120-4335001

[email protected] www.jmv.co.in