S.L.T.-XM200 Bench

Study and operate the

protection features

associated with the

neutral plans with manual

troubleshooting

ebau312
Tampon

www.schneider-electric.com/educationalequipments 3/10

S.L.T.-XM200 Bench

1. Presentation of the kit

This bench illustrates the rationale underlying the current regulations and standards concerning the physical protection of individuals as regards the TN or TT systems (first working

surface) and the IT system (second working surface).

1.1 Overview

On each of the totally independent surfaces, 3 single or three-phase receivers have been represented, with protection devices based on magneto-thermal circuit-breaker, differential

circuit-breakers, differential switches, contactors.

Power resistors and a rehostat located in the base of the bench are connected to the panel by cables (supplied) fitted with safety jacks for operations under the supervision of a qualified

teacher.

IT system TN or TT systems

4/10 www.schneider-electric.com/educationalequipments

S.L.T.-XM200 Bench

1.2 Characteristics

Mechanical characteristics

Dimensions: height: 1900 mm, width: 770 mm, depth: 600 mm (920 shelves unfolded)

Weight: 152 kg

Electrical characteristics

The bench is powered by a 400 V three-phase electrical network with earth power ≥ 4 kVA.

Voltage: 400 V three-phase ± 10 %

Frequency: 50 Hz ± 5 %

Current: 16 A, connection by 3P + earth socket

The conventional short-circuit current is set to 10 kA.

Rated impulse withstand voltage: 2,5 kV

Protection class: l

The electrical network must be fitted with a RCD (Residual Current Device) of sensitivity ≤ 30 mA of AC class upstream the bench (not supplied).

Technical characteristics of built-in components

Isolation controller

– Vigilohm XM200 380-415V

Transformers

– Transformer 48VA u : 230/400V S : 24 VA

– 2 Star-triangle three phase transformer

Circuit breaker

– Three pole magneto-thermal circuit-breaker 4 to 6,3A

– Two pole magneto-thermal circuit-breaker 1A and 0,5A

– Four pole circuit breaker 16A

– Three pole circuit breaker 10A

– Two pole circuit breaker 12A, 0,5 et 6A

– Differential bipolar circuit breaker 240V 25A 10mA

www.schneider-electric.com/educationalequipments 5/10

S.L.T.-XM200 Bench

1.3 Functional description

The S.L.T. XM200 bench allows the users to perform exercises on the various neutral plans.

The two surfaces may be used at the same time, one for TN and TT neutral plans exercises, the other for the IT neutral plan exercises.

Two single-phase receivers (R1 and R2) and a three-phase receiver have been represented.

It has been assumed, for the sake of clarity and to assist in training, that receivers are in premises of various classes. The R3 receiver is supposed to be installed in fire risk premises.

The user can then perform the various exercises on the two surfaces of the bench as well as on

the power resistors located in the base of the bench.

6/10 www.schneider-electric.com/educationalequipments

S.L.T.-XM200 Bench

2. Teaching

2.1 Teaching presentation

S.L.T. XM200 Bench allows:

Theoretical study of the various neutral plans.

Circuit cabling and study of device responses

On the IT neutral plan: manual troubleshooting system.

It is intended to the following studies:

Professional High School University &

Engineering school

Automated Systems Industrial Computing

Monitoring and Regulation

Electrical Engineering

Engineering Equipment Energy

Industrial Maintenance

Automated Production

Mechanical Industrial Automated Systems

Miscellaneous Industrial Automated Systems

Exercises to be performed from the S.L.T.-TR22 bench:

The exercises are composed of a teacher document and a student document.

TT neutral plan:

– Interconnection and earthing of groundings are necessary conditions but not sufficient to ensure protection.

– The magneto-thermal circuit breakers do not ensure the protection against the indirect contacts.

– The use of a RCD is a necessary condition but not sufficient to ensure protection (threshold selection).

– The use of a RCD is a necessary condition but not sufficient to ensure protection (RA maximum value).

– Selective activation by RCD located at various level.

– The earthing connection values must be measured regularly.

– Fire risk.

– Mobile receivers.

TN neutral plan:

– An earth fault leads to an overcurrent which is eliminated by standard circuit breakers.

– Does a given circuit-breaker ensure protection in every case?

– What to do if the conditions are not fulfilled?

www.schneider-electric.com/educationalequipments 7/10

S.L.T.-XM200 Bench

IT neutral plan:

– Interconnection and earthing of frames are necessary and sufficient conditions for protection in case of a first fault.

– Permanent insulation monitoring of the network with respect to earth and indication of a first fault.

– Single fault: location of faulty feeder by successive opening of the various circuit-breakers.

– Single fault: location of faulty feeder by injecting ac current at very low frequency.

– Single fault: location of faulty feeder by injecting ac current at very low frequency and fixed detectors

– Double fault: full fault on R2 (phase 3) - full fault on R3 (phase 1): need to provide RCDs on long feeders.

– Double fault : full fault on R2 (phase 3) - full fault on R3 (phase 1): circuit-breaker protection are sufficients with protection.

– Single fault: taking into account of the transitions causing transient fault.

8/10 www.schneider-electric.com/educationalequipments

S.L.T.-XM200 Bench

2.2 Teaching examples

www.schneider-electric.com/educationalequipments 9/10

S.L.T.-XM200 Bench

10/10 www.schneider-electric.com/educationalequipments

S.L.T.-XM200 Bench

3. Items provided with the kit

3.1 Equipment provided

A ready-to-use S.L.T.-XM200 bench assembly with two double-sided working surface reference MDG99603.

A set of safety cables

3.2 Documentation

A technical manual and exercise book (reference MDG9AD603EN)