Wuzheng Meng([email protected])

12 June 2008

Page 2: E821 SC Inflector and Beyond Wuzheng Meng (meng@bnl.gov) 12 June 2008

I. Design Constrains – a brief history• E821 (originally) proposed a pulsed inflector . R&D was performed up to

late 1989 (g-2 note No.32).

• DC SC inflector was proposed in 1988 (g-2 note No.25), and finally approved by collaboration in late 1990 (or early 1991?).

• By that time, the design of the storage ring magnet was almost completed (cross-section and conductor type), except some controversial shimming methods.

E821 SC inflector final design had to fit this pre-defined limited space.

Page 3: E821 SC Inflector and Beyond Wuzheng Meng (meng@bnl.gov) 12 June 2008

Down-stream –

Vertical limit: storage ring magnet gap (180 mm) Horizontal: must as close as possible to the muon storage center (77 mm)

Page 4: E821 SC Inflector and Beyond Wuzheng Meng (meng@bnl.gov) 12 June 2008

Up-stream ---

Limited in radial direction, by storage ring outer coil cryostat

Page 5: E821 SC Inflector and Beyond Wuzheng Meng (meng@bnl.gov) 12 June 2008

Could we make it shorter?

Could we make it curved, so that Leff could be longer?

By

S

In order to cancel 2.55 T-mFringe field from storage ring,

Bo = 1.5 T and L= 1.7 mare comfortable for a low Tc NbTi SC septum magnet

----- We did not feel comfortable about Lorentz force constrains (in the inner side)

Page 6: E821 SC Inflector and Beyond Wuzheng Meng (meng@bnl.gov) 12 June 2008

II. Design Principle – truncated double cosθ Single cosθ distribution (R. Beth, BNL AADD-102,1966)

“Field Produced by Cylindrical Current Arrays”

K1cosθ

Page 7: E821 SC Inflector and Beyond Wuzheng Meng (meng@bnl.gov) 12 June 2008

Double cosθ Distribution and Truncation along Vector-potential lines --- Frank Krienen (NIM A283(1989)5)

K1cosθ

-K2cosθ

Page 8: E821 SC Inflector and Beyond Wuzheng Meng (meng@bnl.gov) 12 June 2008

Conductor -- Astromag/g2Inf

Configuration (NbTi:Cu:Al): 1: 0.9: 3.7

Processor: Co-extrusion

NbTi/Cu composite: diameter 1.6 mm (monolith)

NbTi Finament: diameter 0.02 mm

Twist pitch: 31 mmConductor dimension: 2 x 3 mm (bare); 2.3 x 3.3 mm (insulated)

Critical current density Jc > 2500 A/mm2 @ 5 T, 4.2 K

Stabilizer purl Al: 99.997%; RRR=750

NbTi area = 1.06 mm2

Page 9: E821 SC Inflector and Beyond Wuzheng Meng (meng@bnl.gov) 12 June 2008

Prof. Akira Yamamoto (KEK)and Tokin Co.

Cold mass: 60 kgCooling power: 11 W Stored energy: ~9000 J

Inductance: 0.002 H

Page 10: E821 SC Inflector and Beyond Wuzheng Meng (meng@bnl.gov) 12 June 2008

Conductor positions were modified to avoid technical difficulties

Page 11: E821 SC Inflector and Beyond Wuzheng Meng (meng@bnl.gov) 12 June 2008

III. Choices of Ends –

Open-end Closed-end

Page 12: E821 SC Inflector and Beyond Wuzheng Meng (meng@bnl.gov) 12 June 2008

Based upon following arguments, E821 chose Closed End (July 1991):

(1) Easier for fabrication, force constrains (large quench margin);

(2) Physical dimension is shorter;

(3) Smaller integral fringe field (~1/6)

Although closed-end has disadvantage –

Less muons (~ 1/1.44) are injected and stored due to Multiple scatterings through materials (11mm Al; 0.8mm NbTi; 0.8mm Cu): ---- 20 turn (x2 layer) conductors; ---- coil caps; ---- windows on the mandrel and cryostat

Page 13: E821 SC Inflector and Beyond Wuzheng Meng (meng@bnl.gov) 12 June 2008

IV. Fringe Field Issues –Sources of fringe field: (a) continue current distribution is replaced by discrete individual conductor winding; (b) end effect (principle is based on 2d potential theroy)

Consequence of fringe field: Total integrated fringe field (~7ppm); peak field (in storage region) >200 Gauss and high gradients are beyond stable range of NMR probes. Special regional measurements introduce additional systematical errors (0.2 ppm) .

Magneto-static shimming did not work!SC shield is the solution!

Page 14: E821 SC Inflector and Beyond Wuzheng Meng (meng@bnl.gov) 12 June 2008

Superconductivity -- (T<Tc; J< Jc; B<Bc)

(1) Zero Electric Resistivity

(2) Diamagnetism

Type I Type II κ = λ(T)/ξ(T) < 1/ κ = λ(T)/ξ(T) > 1/ Pure state (H < Hc) Mixed state (Hc1< H < Hc2) Meissner effect “Perfect conductor” Can tolerate low flux density Can tolerate high flux density No use for magnets Good for magnets and flux shields

λ(T) --- magnetic penetration depthξ(T) --- coherence length

κ ---- Ginzburg-Landau parameter

22

Page 15: E821 SC Inflector and Beyond Wuzheng Meng (meng@bnl.gov) 12 June 2008

Type I SC Type I SCType II SC Type II SC

T = 300 K T = 300 K

T = 4 K T = 4 K

Figure from W. H. Warnes: “Principles of Superconductivity” (Red Text added by W. Meng)

B = 0

B = Ba

Ba = 0 Ba = 0

B = Ba

Page 16: E821 SC Inflector and Beyond Wuzheng Meng (meng@bnl.gov) 12 June 2008

Multilayer SC Sheet

Nippon Steel CorporationAdvanced Technology Research Lab

Dr. Ikuo Itoh

Jc > 1200 A/mm2

@1.5 T, 4.2 K, H NbTi layer B = μ0Jc d

(d = Total thickness of NbTi layers)

Page 17: E821 SC Inflector and Beyond Wuzheng Meng (meng@bnl.gov) 12 June 2008

Working Procedure --

Main magnet poweredFlux penetrating

Inflector stays “warm”Un-powered

Main magnet stable

Cool down inflector Main flux are trapped

by the SC shield

10 K 4.6 K 4.6 K

(1) (2) (3)

Power Inflector slowly(Io 2850 A; 2 A/sec)Main flux are trapped

Fringe flux are blockedby the SC shield

Page 18: E821 SC Inflector and Beyond Wuzheng Meng (meng@bnl.gov) 12 June 2008

V. Possible Modification & Improvement–

Open both ends:

Prof. Akira Yamamoto & Tokin Co Contributions – 1 prototype (L=0.5 m) and 2 full length (1.7 m) SC inflectors

Prototype was tested up to 3057 A In KEK (with zero external field)

Prototype was tested up to 3000 A In BNL with Ba=1.45 T

(inside 18D72 magnet)

Figure from Tokin Technical Review No.20

March 1993 July 1994

Page 19: E821 SC Inflector and Beyond Wuzheng Meng (meng@bnl.gov) 12 June 2008

Encouraged facts –

Open-end has been tested in the external field. SC performance was very stable.

Open-end gives additional magnetic field along beam axis.

(further detailed study is needed)

Although open-end gives more integral fringe field (x 6); peak field on inflector cold surface is estimated ~ 0.1 T.

Existing SC sheet has enough shielding capability (0.23 T).