e52175-006 sr1600ur qsug back - intel€¦ · nic1-2 2. install the server into the rack using the...

1
A complete list of accessories and spares can be found at: http://www.intel.com/p/en_US/support/highlights/server/s5520ur Front Panel Controls and Indicators Intel® Local Control Panel Standard Control Panel O M L K J H I N G C D E F B A J I L K B A F G H E D C A NIC2 Activity LED B. NIC1 Activity LED C. Power/Sleep Button D. Power/Sleep LED E. Hard Drive Activity LED F. Status LED G. System ID LED H. System ID Button I. Reset Button J. USB 1.1 Port K. NMI (recessed) Button L. Video (hot- swap drive system only) A USB 1.1 Port B. LCD Display C. Menu Control Button - Up D. Menu Control Button - Down E. Menu Control Button - Left F. Menu Control Button - Enter G. ID LED H. Power/Sleep LED I. Power/Sleep Button J. System Status LED K. NIC 2 Activity LED L. NIC 1 Activity LED M. HDD Activity LED N. Reset Button O. USB 1.1 Port 19 Install Top Cover Note: Security screw re-installation is optional. A Place cover as shown, slide forward to engage recessed edge at front of cover. Make sure latch is locked. A Recessed Edge 18 Install Rack Handles Note: Rack handles are required to install the bezel. For instructions, see the Service Guide. 17 Install Intel® Local Control Panel (optional) Press the blue locking lever at the back of the control panel and push it forward to release it from the chassis. B Disconnect the front panel and USB cables from the backplane as shown. A Slide the control panel and cables out of the chassis. C Slide control panel fully into chassis until the locking lever engages. F Feed local control panel cables into chassis opening. E Connect the USB and data cables to the local control panel as shown. D Connect the two cables to the USB and front panel connectors on the backplane as shown. G Remove Standard Control Panel Install Local Control Panel C D D F B Locking Lever Local Control Panel E Backplane G A Note: The Intel® Local Control Panel option is only supported in hot-swap drive systems. 16 Install PCI Add-in Card Riser Assembly PCI Riser Socket Chassis Slots (2) Hooks (2) Riser Card Edge Connector Processor Air Duct Air Duct Slot Position riser card edge connector over the server board riser socket and align the two hooks in the riser with the slots at the back of the chassis. A Press down uniformly until the two hooks on the rear of the PCI riser assembly engage the chassis back panel slots. The riser card will seat into the matching riser socket on the server board. B Note that the riser assembly card edge installs in the slot in the processor air duct. 15 Install Add-in Card (optional) A Remove filler panel from the add-in card slot. B Insert add-in card until it seats in riser connector. C Secure the add-in card with screw as shown. CAUTION: Observe normal ESD precautions when installing the add-in card. Riser Connector REMOVE Filler Panel A C Remove the screw as shown. D D B 14 Install Processor Air Duct Use care to avoid pinching system cables. Processor Air Duct Install processor air duct as shown making sure the front edge of the duct aligns correctly with the notches on the fan module. 11 Install Hot-swap Drive System Components ... for a Fixed Drive System, go to Step 12 Position backplane over six chassis standoffs. A Engage standoffs and slide the backplane in the direction shown to lock into place. B Tighten blue thumbscrew. C Install the Backplane Note: Both the active and passive backplanes install the same. Open the backplane bridge board connector retention clip. A Install the Bridge Board Route the five fan module cables over the fan guard and connect to the corresponding connectors on the backplane. A Connect the USB and data cables from the control panel to the USB and front panel connectors on the backplane. B Make Cable Connections Connect the power supply cable to the power connector located on the backplane. C Passive Backplane Only: Connect the hard drive SATA cables from the server board to the corresponding SATA connectors on the backplane. D A C Active Backplane B B Server Board A B Bridge Board Install bridge board making sure the connector edges on both sides align correctly with the slots, and by pressing down on both sides simultaneously. Close the retention clips. B A Install Hot-swap Hard Drives Drive 0 Primary Hard Drive Numbering Diagram 1 2 0 Repeat these steps for each installed hard drive. Remove hot-swap drive carrier(s) by pushing green latch towards the lever, opening the lever all the way, and then pulling the drive carrier out of the system. A Remove the plastic air baffle and save for future use. B Install the hard disk drive and attach with four screws. C With the carrier lever in the OPEN position, slide drive assembly into chassis until it stops, then close the lever until it snaps shut. D CAUTION: If you install less than three drives or devices, empty drive bays must be occupied by carriers with baffles to maintain proper system cooling. To avoid possible damage to your chassis, use only carriers that came with your server system. Install Air Baffle Cabling Legend: Main Power Cable CPU Power Cable Power Signal Cable Optical Drive Data Cable SATA 0-2 HDD Data Cables (passive backplane only) Route all applicable cables (see the ‘Cabling Legend’ below) through the baffle notches and snap air baffle into place. The baffle is held in place by two snap-standoffs on the chassis floor. A Note: Front tab of air baffle must fit under the drive bay cover prior to lowering into chassis standoffs to ensure a proper fit. Make sure that all the cables are seated over the backplane. SATA 0 SATA 1 SATA 2 Passive Backplane Fan Connectors B C Fan Module A SATA 0 SATA 1 SATA 2 SATA Connector Detail D D SATA Conn. Details D Server Board Snap Stand-offs Power Signal Main Power CPU Power SATA Connector SATA Connectors Power Supply SATA 0 HDD SATA 1 HDD Optical Drive Front Tab SATA 2 HDD A Standoff Detail Air Baffle USB Cable Data Cable 12 Install Fixed Drive System Components...for a Hot-swap Drive System, go to Step 11 SATA 0 SATA 1 SATA 2 Backplane Fixed Drive 1 Power Supply Cable Connector Install Hard Drive Cables Connect SATA data cable(s) to server board as shown. A Connect opposite end of SATA data cable(s) to hard drive(s) as shown ... see detail below. B Connect the SATA fixed drive power connectors to each hard drive as shown ... see detail. C BLUE indicates Data Cable RED indicates Power Cable Cable Legend Data Power Back View of SATA Drive B C A Server Board Install Air Baffle Standoff Detail Front Tab Main Power CPU Power Power Signal SATA Connector Cabling Legend: Main Power Cable CPU Power Cable Power Signal Cable Optical Drive Data Cable SATA 0-2 HDD Data Cables SATA 0-2 HDD Power Cables Route all applicable cables (see below) through the baffle notches and snap air baffle into place. The baffle is held in place by two standoffs on the chassis floor. A Note: Front tab of air baffle must fit under the drive bay cover prior to lowering into chassis standoffs to ensure a proper fit. Drive Bay Cover Power Supply SATA Connectors Power Supply SATA 0 HDD SATA 1 HDD SATA 2 HDD Fixed SATA Drive 0 Fixed SATA Drive 1 Optical Drive Air Baffle A Install Fixed Hard Drives/Carriers Slide each carrier into a drive opening until the blue carrier latch clicks into place. Repeat these steps for each installed hard drive CAUTIONS: If you install less than three drives, empty drive bays must be occupied by carriers with baffles to maintain proper system cooling. To avoid possible damage to your chassis, use only carriers that came with your server system. Remove the Plastic Air Baffle B D Install the hard disk drive and attach with four screws. C Install 1st drive here. Install 2nd drive here. Hard Drive Numbering Diagram 1 2 0 Carrier Latch Remove fixed drive carrier(s) by pressing blue carrier latch from inside the chassis, pushing the drive carrier forward, and sliding it out of the system. A Install 3rd drive here. Fixed Drive 2 Optical Device Fixed Drive 0 Fixed SATA Drive 2 Backplane 13a Install SATA Optical Device (optional) 1. Remove the Empty Tray 2. Install Device into the Tray Align the two holes on the left edge of the optical device with the two metal tabs in the tray. A 3. Install Optical Device Tray Assembly into the Chassis Pull the power and data cables through the front of the chassis opening. A A Remove the empty tray from the accessory kit box. Empty Optical Device Tray B Metal Tab A CAUTION: To maintain proper system cooling, a filler blank must be installed if you do not install a device at this location. Optical Device Tray Assembly Blue Release Lever C D Optical Device Tray Assembly Optical Drive B Data Power Connect the cables as shown. B A Lower opposite side of optical device into the tray until it clicks into place. B From the back side of the device bay, pull the cables back into the chassis opening as you insert the device. C Verify that the blue release lever on the tray locks into place. D Note: The power end of the SATA optical device cable comes attached to the midplane board power cable. 13b A Connect the SATA end of the cable to one of the server board SATA connectors. Server Board SATA Connectors SATA Conn. Detail Power Supply A SATA Cable from Optical Device 4. Install Optical Device Data Cable AXXHERAIL2 Cable Management Arm Tool-less Rail Kit ADWBEZBLACK Bezel for Standard Control Panel Optional Accessories and Order Codes AXXRACKARM2 AXXBASRAIL13 Fixed Bracket Kit Basic Slide Rail Kit AXXBRACKETS ADWLCDBEZEL Bezel for Intel ® Local Control Panel Infiniband* I/O Expansion Module AXXSATADVDROM Slimline DVD-ROM/CD-ROM Drive AXXLCPRACK2 Intel ® Local Control Panel AXXGBIOMOD Dual Gigabit I/O Expansion Module AXXSASIOMOD SAS I/O Expansion Module 10 Gigabit I/O Expansion Module AXXRMM3 AXXIBIOMOD Intel ® Remote Management Module 3 AXX10GBIOMOD Quad-Port Gigabit I/O Expansion Module AXX4GBIOMOD2 20 Finishing Up Before installing your operating system, you must finish your system installation, make I/O connections, and plug in AC power. AC Power CAUTION: This unit must be operated with the TOP COVER installed to ensure proper cooling. Video 1. Replace the system cover. I/O Exp. Module USB 0-3 Intel ® RMM3 Module Serial Port A Network NIC1-2 2. Install the server into the rack using the instructions provided with the rack mounting kit. 3. Connect your USB keyboard/mouse, video and other I/O cables/devices as shown. Then connect the AC power cord. 21 Software BIOS, Drivers, and Operating System Installation C. Install your Operating System: Use the instructions provided with the RAID controller and with the operating system. D. Install Operating System Drivers: With the operating system running, insert the Intel ® Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the Express Installer will autorun and allow you to select the appropriate drivers to install. On other operating systems, browse the CD folders to locate and install the driver files. A. Update the System Software: 1. Boot from the Intel ® Server Deployment Toolkit CD. 2. Use the Wizard to access the latest versions on the Internet and update the BIOS, firmware, FRUSDRs, and Intel ® RMM3. Note: You can also use downloaded files on a USB key. B. Configure your RAID Controller: If using a RAID card, use the instructions provided with the RAID controller. If using on-board RAID, you must activate RAID in the BIOS setup. See the Intel ® Server Board S5520UR Technical Product Specification for more information. E. Install Intel® System Management Software (optional): Download the latest version of the Intel ® System Management Software from http://www.intel.com/go/servermanagement and use the instructions provided at that link to install the software. Intel® Server Board S5520UR Component Layout See your Intel ® Server System SR1600UR Service Guide for expanded component and connection information. Diag. LEDs USB 8, 9 USB 2, 5 Video ID LED Serial A CPU 1 I/O Exp. Module Conn. 1 I/O Exp. Module Conn. 2 SGPIO SATA Key LCP/AUX IPMB BMC Force Update Front USB SSD USB Power Supply Signal Conn. Serial B SATA 5 SATA 0 SATA 1 SATA 2 SATA 3 SATA 4 DIMM Status LEDs CPU 2 Fan Mem 2 Fan CPU Power Front Panel CPU 2 Bridge Board Conn. Sys 1 Fan Sys 2 Fan NIC1 NIC2 DIMM A2 DIMM C1 DIMM A1 DIMM B2 DIMM B1 DIMM C2 Main Power Fan Board DIMM Status LEDs Battery DIMM F1 DIMM D2 DIMM F2 DIMM E1 DIMM E2 DIMM D1 PCIe* Riser RMM3 Conn. CPU 1 Fan Mem 1 Fan Status LED BIOS Recover Password Clear BIOS Default Serial Port Config. Document/Tool Available Documents Technical Product Specification Spares, Parts List, and Configuration Guide Server Configurator Tool Software and Drivers Content In-depth technical information Supported accessories and spares list Tested peripherals and operating systems list Tested memory list Supported processors list Up-to-date firmware, driver, and utility information A link to the above documents, Server Configurator Tool, and the Software and Drivers web page can be found at: http://www.intel.com/p/en_US/support/highlights/server/s5520ur.

Upload: others

Post on 24-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: E52175-006 SR1600UR QSUG back - Intel€¦ · NIC1-2 2. Install the server into the rack using the instructions provided with the rack mounting kit. 3. Connect your USB keyboard/mouse,

A complete list of accessories and spares can be found at: http://www.intel.com/p/en_US/support/highlights/server/s5520ur

Front Panel Controls and IndicatorsIntel® Local Control Panel Standard Control Panel

O M L K J HIN G

CDEF

BA

J IL K

BA F G HEDC

A NIC2 Activity LEDB. NIC1 Activity LEDC. Power/Sleep ButtonD. Power/Sleep LED

E. Hard Drive Activity LEDF. Status LEDG. System ID LED

H. System ID ButtonI. Reset ButtonJ. USB 1.1 PortK. NMI (recessed) ButtonL. Video (hot- swap drive system only)

A USB 1.1 PortB. LCD DisplayC. Menu Control Button - UpD. Menu Control Button - Down

E. Menu Control Button - LeftF. Menu Control Button - EnterG. ID LEDH. Power/Sleep LED

I. Power/Sleep ButtonJ. System Status LEDK. NIC 2 Activity LEDL. NIC 1 Activity LEDM. HDD Activity LEDN. Reset ButtonO. USB 1.1 Port19 Install Top Cover

Note: Security screwre-installation is optional.

APlace cover as shown, slide forwardto engage recessed edge atfront of cover. Make surelatch is locked.

A

RecessedEdge

18 Install Rack Handles

Note: Rack handles are required to install the bezel. For instructions, see the Service Guide.

A

17 Install Intel® Local Control Panel (optional)

Press the blue locking lever at the back of the control panel and push it forward to release it from the chassis.

B

Disconnect the front panel and USB cables from the backplane as shown.

A

Slide the control panel and cables out of the chassis.

C

Slide control panel fully into chassis until the locking lever engages.

FFeed local control panel cables into chassis opening.E

Connect the USB and data cables to the local control panel as shown.

D

Connect the two cables to the USB and front panel connectors on the backplane as shown.

G

Remove Standard Control Panel Install Local Control Panel

C

A

D D

F

BLockingLever

ServerBoard

LocalControl Panel

E

BackplaneG

A

Note: The Intel® Local Control Panel option is only supported in hot-swap drive systems.

16 Install PCI Add-in CardRiser Assembly

PCI RiserSocket

ChassisSlots (2)

Hooks (2)

Riser CardEdge Connector

ProcessorAir Duct

Air DuctSlot

Position riser card edge connector over the server board riser socket and align the two hooks in the riser with the slots at the back of the chassis.

A

Press down uniformly until the two hooks on the rear of the PCI riser assembly engage the chassis back panel slots.

The riser card will seat into the matching riser socket on the server board.

B

Note that the riser assembly card edge installs in the slot in the processor air duct.

15 Install Add-in Card(optional)

A Remove filler panel from the add-in card slot.

BInsert add-in card until it seats in riser connector.CSecure the add-in card with screw as shown.

CAUTION:Observe normal ESD precautions when installing the add-in card.

Riser Connector REMOVE Filler Panel

A

C

Remove the screw as shown.

D

DB

14 Install Processor Air Duct

Use care to avoid pinching system cables.

ProcessorAir DuctInstall processor

air duct as shown making sure the front edge of the duct aligns correctly with the notches on the fan module.

11 Install Hot-swap Drive System Components ...for a Fixed Drive System, go to Step 12

Position backplane over six chassis standoffs.

A

Engage standoffsand slide the backplane in the direction shown to lock into place.

B

Tighten blue thumbscrew.

C

Install the BackplaneNote: Both the active and passive backplanes install the same. Open the backplane bridge board connector

retentionclip.

AInstall the Bridge Board

Route the five fan module cables over the fan guard and connect to the corresponding connectors on the backplane.

A

Connect the USB anddata cables from the control panel to the USB and front panelconnectors on the backplane.

B

Make Cable Connections

Connect the power supply cable to the power connector located on the backplane.

C

Passive Backplane Only: Connect the hard drive SATA cables from the server board to the corresponding SATA connectors on the backplane.

D

AC

Active Backplane

B

BServerBoardA

BBridge Board

Install bridge board making sure the connector edges on both sides align correctly with the slots, and by pressing down on both sides simultaneously. Close the retention clips.

B

AInstall Hot-swap Hard Drives

Drive 0 Primary

Hard Drive Numbering Diagram

1 20

Repeat these steps for each installed hard drive.

Remove hot-swap drive carrier(s) by pushing green latch towards the lever, opening the lever all the way, and then pulling the drive carrier out of the system.

A

Remove the plastic air baffle and save forfuture use.

B

Install the hard disk drive and attach with four screws.

C

With the carrier lever in the OPEN position, slide drive assembly into chassis until it stops, then close the lever until it snaps shut.

D

CAUTION: If you install less than three drives or devices, empty drive bays must be occupied by carriers with baffles to maintain proper system cooling. To avoid possible damage to your chassis, use only carriers that came with your server system.

Install Air Baffle

Cabling Legend:• Main Power Cable• CPU Power Cable• Power Signal Cable• Optical Drive Data Cable• SATA 0-2 HDD Data Cables (passive backplane only)

Route all applicable cables (see the ‘Cabling Legend’ below) through the baffle notches and snap air baffle into place.

The baffle is held in place by two snap-standoffs on the chassis floor.

A

Note: Front tab of air baffle must fit under the drive bay cover prior to lowering into chassis standoffs to ensure a proper fit.

Make sure that all the cables are seated over the backplane.

SATA 0 SATA 1 SATA 2

PassiveBackplane

Fan ConnectorsB

C

Fan Module

A

SATA 0SATA 1

SATA 2

SATAConnector

Detail

D

D

SATA Conn.Details

DServer Board

Snap

Stand-offs

Power Signal

Main Power

CPU Power

SATA Connector

SATA Connectors

Power

Supply

SATA 0 HDD

SATA 1 HDD

Optical Drive

FrontTab

SATA 2 HDD

A

Standoff Detail

Air Baffle

USBCable

Data Cable

12 Install Fixed Drive System Components...for a Hot-swap Drive System, go to Step 11

SATA 0 SATA 1 SATA 2

Backplane

FixedDrive 1

PowerSupply

CableConnector

Install Hard Drive CablesConnect SATA data cable(s) to server board as shown.AConnect opposite end of SATA data cable(s) tohard drive(s) as shown ... see detail below.

B

Connect the SATA fixed drive power connectors to each hard drive as shown ... see detail.

C

BLUE indicates Data CableRED indicates Power Cable

CableLegend

Data

Power

Back View of

SATA Drive

BC

A

ServerBoard

Install Air Baffle

Standoff Detail

FrontTab

Main Power

CPU Power

Power Signal

SATA Connector

Cabling Legend:• Main Power Cable• CPU Power Cable• Power Signal Cable• Optical Drive Data Cable• SATA 0-2 HDD Data Cables• SATA 0-2 HDD Power Cables

Route all applicable cables (see below) through the baffle notches and snap air baffle into place.

The baffle is held in place by two standoffs on the chassis floor.

A

Note: Front tab of air baffle must fit under the drive bay cover prior to lowering into chassis standoffs to ensure a proper fit.

Drive Bay Cover

PowerSupply

SATA Connectors

Power

Supply

SATA 0 HDD

SATA 1 HDD

SATA 2 HDD

FixedSATADrive 0FixedSATADrive 1

Optical Drive Air Baffle

A

Install Fixed Hard Drives/Carriers

Slide each carrier into a drive opening until the blue carrier latch clicks into place.

Repeat these steps foreach installed hard drive

CAUTIONS: If you install less than three drives, empty drive bays must be occupied by carriers with baffles to maintain proper system cooling.To avoid possible damage to your chassis, use only carriers that came with your server system.

Remove the Plastic Air BaffleB

D

Install the hard disk drive and attach with four screws.

C

Install 1st drivehere.

Install 2nddrive here.

Hard Drive Numbering Diagram

1 20

CarrierLatch

Remove fixed drive carrier(s) by pressing blue carrier latch from inside the chassis, pushingthe drive carrier forward, and sliding it out of the system.

A

Install 3rddrive here.

FixedDrive 2

OpticalDevice

FixedDrive 0

FixedSATADrive 2

Backplane

13aInstall SATA Optical Device (optional)

1. Remove the Empty Tray

2. Install Device into the Tray

Align the two holes on the left edge of the optical device with the two metal tabs in the tray.

A

3. Install Optical Device Tray Assembly into the Chassis

Pull the power and data cables through the front of the chassis opening.

AA Remove the empty

tray from the accessory kit box.

EmptyOpticalDevice Tray

B

Metal Tab

A

CAUTION: To maintain proper system cooling, a filler blank must be installed if you do not install a device at this location.

OpticalDevice Tray

Assembly Blue ReleaseLever

C

D

OpticalDevice Tray

Assembly

OpticalDrive B

Data

Power

Connect the cables as shown.

B

A

Lower opposite side of optical device into the tray until it clicks into place.

B

From the back side of the device bay, pull the cables back into the chassis opening as you insert the device.

C

Verify that the blue release lever on the tray locks into place.

D

Note: The power end of the SATA optical device cable comes attached to the midplane board power cable.

13b

A Connect the SATA end of the cable to one of the server boardSATA connectors.

Server BoardSATA Connectors

SATA Conn.Detail

PowerSupply

A

SATA Cablefrom Optical Device

4. Install Optical Device Data Cable

AXXHERAIL2Cable Management ArmTool-less Rail Kit

ADWBEZBLACKBezel for Standard Control Panel

Optional Accessories and Order Codes

AXXRACKARM2AXXBASRAIL13

Fixed Bracket KitBasic Slide Rail Kit

AXXBRACKETS

ADWLCDBEZELBezel for Intel® Local Control Panel

Infiniband* I/O Expansion Module

AXXSATADVDROMSlimline DVD-ROM/CD-ROM DriveAXXLCPRACK2Intel® Local Control Panel

AXXGBIOMODDual Gigabit I/O Expansion ModuleAXXSASIOMODSAS I/O Expansion Module

10 Gigabit I/O Expansion Module

AXXRMM3

AXXIBIOMOD

Intel® Remote Management Module 3

AXX10GBIOMOD

Quad-Port Gigabit I/O Expansion Module

AXX4GBIOMOD2

20Finishing Up

Before installing your operating system, you must finish your system installation, make I/O connections, and plug in AC power.

AC Power

CAUTION: This unit must be operated with the TOP COVER installed to ensure proper cooling.

Video

1. Replace the system cover.

I/O Exp. Module

USB 0-3 Intel ® RMM3 ModuleSerialPort A

Network

NIC1-2

2. Install the server into the rack using the instructions provided with the rack mounting kit.3. Connect your USB keyboard/mouse, video and other I/O cables/devices as shown. Then connect the AC power cord.

21 Software • BIOS, Drivers, and Operating System Installation

C. Install your Operating System: Use the instructions provided with the RAID controller and with the operating system.

D. Install Operating System Drivers: With the operating system running, insert the Intel® Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the Express Installer will autorun and allow you to select the appropriate drivers to install. On other operating systems, browse the CD folders to locate and install the driver files.

A. Update the System Software: 1. Boot from the Intel® Server Deployment Toolkit CD.2. Use the Wizard to access the latest versions on the Internet and update the BIOS, firmware, FRUSDRs, and Intel® RMM3. Note: You can also use downloaded files on a USB key.

B. Configure your RAID Controller: If using a RAID card, use the instructions provided with the RAID controller. If using on-board RAID, you must activate RAID in the BIOS setup. See the Intel® Server Board S5520UR Technical Product Specification for more information.

E. Install Intel® System Management Software (optional): Download the latest version of the Intel® System Management Software from http://www.intel.com/go/servermanagement and use the instructions provided at thatlink to install the software.

Intel® Server Board S5520URComponent LayoutSee your Intel® Server System SR1600UR Service Guide for expanded component and connection information.

Diag.LEDs

USB8, 9

USB2, 5 Video ID LED

Serial A

CPU 1

I/O Exp.Module Conn. 1

I/O Exp.Module Conn. 2

SGPIOSATA Key

LCP/AUX IPMBBMC Force

Update

Front USBSSDUSB Power

SupplySignalConn.

Serial B

SATA 5

SATA 0

SATA 1

SATA 2

SATA 3

SATA 4

DIMMStatusLEDs

CPU 2Fan

Mem 2Fan

CPUPower

FrontPanel

CPU 2

Brid

ge B

oard

Con

n.

Sys 1Fan

Sys 2Fan

NIC

1

NIC

2

DIM

M A

2

DIM

M C

1

DIM

M A

1D

IMM

B2

DIM

M B

1D

IMM

C2

Main Power

Fan Board

DIMM Status LEDs

Battery

DIM

M F

1

DIM

M D

2

DIM

M F

2D

IMM

E1

DIM

M E

2D

IMM

D1

PCIe

* Ris

er

RM

M3

Con

n.

CPU 1 Fan

Mem 1 Fan

StatusLED

BIOSRecover

PasswordClear

BIOSDefault

Serial PortConfig.

Docu

men

t/Too

lA

vaila

ble

Do

cum

ents

Tech

nica

l Pro

duct

Spec

ifica

tion

Spar

es, P

arts

List,

and

Conf

igur

ation

Gui

de

Serv

er C

onfig

urato

r Too

l

Softw

are a

nd D

river

s

Cont

ent

In-d

epth

tech

nica

l inf

orm

ation

Supp

orted

acce

ssor

ies an

d sp

ares

list

Teste

d pe

riphe

rals

and

oper

ating

syste

ms l

istTe

sted

mem

ory l

istSu

ppor

ted p

roce

ssor

s list

Up-to

-date

firm

ware

, driv

er, an

d ut

ility

info

rmati

on

A lin

k to

the a

bove

doc

umen

ts, S

erve

r Con

figur

ator T

ool,

and

the S

oftw

are a

nd D

river

s web

pag

eca

n be

foun

d at:

http

://ww

w.in

tel.co

m/p

/en_

US/s

uppo

rt/hi

ghlig

hts/

serv

er/s

5520

ur.