7.5.3: Troubleshooting Central Locking System ------------------------ (by Jim Conforti:[email protected]) (Editors note: This pertains to mid-80s -> early 90s cars) Start with doors unlocked and all windows open NOTE: NEVER CONNECT OR DISCONNECT THE CONTROL UNIT UNLESS BATTERY POWER IS REMOVED!! Operation Response Action 1. DDL to lock All doors lock Goto OP #2 Some doors Lock R/R suspect Door Lock Motor
ckt. No doors Lock Goto OP #4 2. DDL to deadbolt All doors double
lock Goto OP #3
Drivers and SOME others dbl lock
R/R suspect Door Lock Motor
Drivers ONLY dbl locks
Perform TEST B
Drivers does NOT dbl lock
Mechanical Problem
3. DDL to unlock All doors unlock Goto OP #4 Some doors unlock R/R suspect Door Lock Motor
ckt. No doors unlock Goto OP #5 4. PDL to lock All doors lock If doors did not lock in OP
#1 R/R DD lock switch else Goto OP #5
Some doors lock R/R suspect Door Lock Motor ckt
No doors lock If doors locked in OP #1 R/R PD microswitch if doors did not lock in OP #1 perform TEST A
5. PDL to lock All doors unlock If doors did not unlock in
OP #3 R/R DD lock switch else Goto OP #6
Some doors unlock R/R suspect Door Lock Motor No doors unlock If doors unlocked in OP #3
R/R PD Lock Switch if doors did not unlock in OP #3 perform TEST C
6. Get in car, close/lock all
Doors remain locked Goto OP #7 doors, IGN to RUN
Doors Unlock R/R Central Locking control unit
7. Get out, DDL to lock
All doors can be unlocked
Goto OP #8 Unlock each door by All doors remain secure Disconnect connector from control unit and check pulling up button for short to ground at terminal #11 if short, find it!, if not R/R Control Unit
8. Trunk lock to Trunk Locks Goto OP #9
LOCK Trunk does not lock If doors lock, R/R Trunk
lock motor and/or circuit If doors do not lock R/R Trunck lock switch R/R Control Unit if switch and circuit are OK
9. Trunk lock to UNLOCK
Trunk unlocks Goto OP #10
Trunk does not unlock
If doors unlock, R/R Trunk lock motor and/or circuit If doors do not unlock, R/R Trunk lock switch R/R Control Unit if switch and circuit are OK
10.Turn key back to LOCK
Gas filler locks Goto OP #11
Gas filler does not lock
R/R Gas Filler Motor ckt.
11.Turn key to unlock
Gas filler unlocks Done, No faults!
Gas filler does not unlock
R/R Gas Filler Motor ckt.
TEST A. Measure Voltage at Control Unit Connector w/ Control Unit Connected Term 3 and Ground should be battery, else check wire to Term 3 for open Term 3 & 4 should be battery, else check wire from Term 4 for open to ground Jumper between Term 7 and ground, if doors lock R/R switches and related wiring else ... Disc. battery, remove Control Unit and reconnect Batt. jumper 1 & 3 together, now jumper 2 & 4 together if doors lock, R/R Control unit, else check wires on Term. 1 & 3 for opens (see schematic) TEST B. With Conrol Unit connected, jumper between 10 & ground doors should double lock, if not, check wires to Term. 11 for opens and R/R Control Unit if no opens found. If doors DO double lock, check wires to Term 10 for open and R/R Unlock Inhibit Switch if wire OK. TEST C With Control Unit connected, Jumper 6 & ground. If doors unlock, R/R switches and related wiring (see schematic) if doors do NOT unlock R/R Control Unit