e302 phy12l
DESCRIPTION
E302TRANSCRIPT
Part 1.Determining the Specific Heat of Metals
Trial 1. Aluminum Metal
Trial 2. Copper Metal
Mass of metal, mm 18.3 g 29.8 g
Mass of calorimeter, mc 58.9 g 58.9 g
Mass of water, mw 221.7 g 227.4 g
Initial temperature of metal, tom
100 oC 100 oC
Initial temperature of calorimeter, toc
30.5 oC 30 oC
Initial temperature of water, tow
30.5 oC 30 oC
Final Temperature of mixture, tmix
32 oC 31 oC
Experimental specific heat of metal, cm
0.28 cal/ g-
Co
0.11 cal/ g-Co
Actual specific heat of metal, cm
0.22 cal/ g-
Co
0.09 cal/ g-Co
Percentage of error 30.02% 21.53 %
Part2. Latent Heat of Fusion IceTrial 1 Trial 2
Mass of calorimeter, mc
58.9 g 58.9 g
Mass of water, mw
227.2 g 227 g
Mass of mixture, mmix
300.6 g 301.1 g
Mass of ice, mi
14.5 g 15.2 g
Initial temperature of ice, tot
0 oC 0 oC
Initial temperature of calorimeter, toc
30.5 oC 30 oC
Initial temperature of water, tow
30.5 oC 30 oC
Final temperature of mixture, tmix
24 oC 26 oC
Experimental Latent heat of fusion, LF
83.59 cal/g 37.11 cal/g
Actual specific latent heat of fusion, LF
80 cal/g 80 cal/g
Percentage of Error
4.49 % 53.62 %