e20/20 step tdr catv operator training january 24, 2012 rev b – 11/21/12
TRANSCRIPT
![Page 1: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/1.jpg)
E20/20 Step TDR
CATVOperator Training
January 24, 2012
Rev B – 11/21/12
![Page 2: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/2.jpg)
Subject SlidesE20/20 Step TDR and Accessories 1-7About the E20/20 TDR 8-9Batteries & Battery Power 10How TDR’s work and Cable Construction 11-17Power On/Off, LCD Display & Example Traces 18-22Keypad & Menu Keys 23-30Function Keys 31-35Advanced Features 36-41Premise Cable Testing 42-49OSP Cable Testing 50-53ETDR PC Vision 54-61Cleaning E20/20 TDR 62Warranty, Maintenance & Contact Info 63Questions & Acknowledgements 64
Table of Contents
2
![Page 3: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/3.jpg)
E20/20 TDR with Soft Carrying Case
3
Our Soft CarryingCase is now Standard with allE20/20 TDRModels
![Page 4: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/4.jpg)
USB CableA-to-Mini B
Not Pictured:CD-ROMQuick Start GuideBasic Guide
Belt Case
E20/20 TDR & Included Accessories
E20/20F Network TDR
AC and DC PowerAdapters
4
F-to-AlligatorClips Lead
RJ-45 to TelcoClips Lead
![Page 5: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/5.jpg)
CD-ROMCD FoldersETDR PC VisionTM - - - - - - - - MS Windows XP or Win 7software TDR Application Notes - - - - - - 20+ Detailed Notes on TDR uses
Operation Manual - - - - - - - - - Electronic Copy OnlyBasic Guide - - - - - - - - - - - - - Backup to Printed CopyQuick Start Guide - - - - - - - - - Backup to Printed Copy Training PPTs - - - - - - - - - - - - General/Broadcast Training CATV Technician
Telephone TechnicianAlso available at:www.aeatechnology.com
5
![Page 6: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/6.jpg)
AC or DC Power and Recharging
12.5 VDC @ 500 mAVehicle running is preferredDC power permits operationOR recharging, but not both
100-240 VAC 50/60 HzAC power permits operation AND Recharging
6
![Page 7: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/7.jpg)
Optional Accessories
Test Leads
F Test Lead4ft (1.2m) Quick Connect
DC Power Cord Ext.USB Cable Ext.
Hard Carrying Case
7
![Page 8: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/8.jpg)
Connector combination for Telcomodel is F and RJ-45
E20/20 Instrument Layout
Quarter VGA backlit display
High tactile feel & weather resistantkeypad with Function Key LEDs
Rugged ABS plastic case withprop stand on the back
8
![Page 9: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/9.jpg)
E20/20F Network Top End
F Connector(field
replaceable)
USB-2 Mini Port
RJ-45 Port
DC Input power jack
ChargingIndicator LED
9
![Page 10: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/10.jpg)
Battery Installation
CAUTIONNO mixing cells
Same Type & mAhr
BATTERY MENU
Select Alkaline or NiMH/NiCd andenter rated mAhrs
10
Meter
![Page 11: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/11.jpg)
How Does a TDR Work?The same as RADAR
Time
11
![Page 12: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/12.jpg)
Cable Velocity and DistanceVelocity is designed in a cable at the time of its manufacture
Velocity is expressed as a fraction of the speed of light
Examples: .66c or 66.7c
Time 2
X Velocity = Distance
20 n Sec 2
X .66c (648,172,800ft/sec) = 6.48 feet
VF or
VPBeware of VF Uncertainty
VoP or
NVP
12
![Page 13: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/13.jpg)
Impedance “Z”
Z = 75 OhmsZ = 100 Ohms
13
![Page 14: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/14.jpg)
Cable Impedance (Z) and ReflectionsImpedance is a factor of both the conductor and the dielectric of the insulation between the conductor & shield or twisted pairs
Any deviation from the manufactured Z will cause reflections
OpenZo=75 or 100
Z = ∞Ω Open
Z = 0
Zo=75 or 100Short
Short
14
![Page 15: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/15.jpg)
Pulse TDR
Pulse TDR
Longer and Longer Dead Zones
15
![Page 16: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/16.jpg)
Step TDR = No Dead Zones – Any Range Fault readings in Ohms
Step TDR
16
![Page 17: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/17.jpg)
Example Step TDR Reflections
Good Splice
Poor Splice
Mixed Impedances Bridged Tap
Water Split Pair ThatResplits
Pinched Coax
Poor QualityCoax
12
910
13
What a “Pulse TDR” Cannot See
17
![Page 18: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/18.jpg)
ON cycle runs Self Test, Calibration, and Restores last use settings
Input Voltage Detect Warning (>1VAC pk-to-pk or 50VDC)OFF cycle saves all settings
Battery Saver shuts down saves all settings
Powering Up/Down
Input over-voltage protection up to 250 VAC or DC
18
![Page 19: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/19.jpg)
Soft Reset & Hard Power Down Perform Soft Reset if: 1. TDR menu cursors are unresponsive
2. Measurement Screen disorganized 3. Other performance issues
Perform a Hard Power Down if TDR will not turn off normally
Press and hold for 10 secondsThen power on with a Soft Reset
19
ENTER Then
“Default Settings” will flashin the splash screen andMeasurement Screen willopen to 0-1KΩ Z Scale
ENTERThen
1 SecPress & Hold 2 Sec Release
![Page 20: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/20.jpg)
Measurement ScreenCable Type,Impedance, &Velocity
ImpedanceScale
Plot Range
Cursor Data – Feet, Inches or meters and Impedance
1 of 2 Cursors
Blinking LowBattery indicator(~20 minutes power remaining)
20
![Page 21: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/21.jpg)
Example E20/20 TDR TracesSeries Resistive Fault Cable Short
Pinched Coax Wet Cable
21
![Page 22: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/22.jpg)
Coax Shield Fault
Good Splice Bad Splice
Bridged Tap
Example E20/20 TDR Traces
22
![Page 23: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/23.jpg)
Menu keysBy name
LED’s indicateactive Function keys Cable ID tones
for coax &twisted pair
Cell style alpha-numeric entrypad
Keypad
Exits menu andsaves changes
Enters A/N changes,distance marks, &Soft Reset
ON/OFF
Cursors, & dataselectioncontrol
23
![Page 24: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/24.jpg)
ENTER
Used to confirm or accept alpha-numeric entries, highlightedlist selections and cursor marked entries for certain features
Soft Reset - Press 4-5 times fast after pressing ON key to activate.
EscReturn to Measurement Screen from menu or back up one menu level. Saves all menu changes
Keypad Controls
24
![Page 25: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/25.jpg)
HELP OVERVIEW
SETUP WIZARDMENU OPERATIONTHE CABLETHE TEST LEADSKEY FUNCTIONS
‘ ‘,’ ‘: SELECT A TOPIC ‘ENTER’:VIEW TOPIC HELP
Help
Step-by-step set up guidance
How the menus work
Cable menu options guide
Test Lead Null guide
Action keys’ LEDs guide
With NO action keys or other menu key selected
Help Key
25
![Page 26: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/26.jpg)
Context sensitive help workswith active Function keysor menu keys and cursor selected features and functions
Help
Context Sensitive Help Example
26
RANGE CONTROL : INCREASE RANGE : DECREASE RANGE
ADJUSTS THE TOTAL DISTANCEDISPLAYED ON THE TRACE
Range
![Page 27: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/27.jpg)
METER SETTINGS
BACKLIGHT : HIGHCONTRAST : 9INPUT CHANNEL : COAX INPUTKEYPAD BEEP : ONBATTERY MENU : ABOUT 5.5HRSDATE/TIME :
22 DEC 2011 12:10PM
Meter
Off, Low, Med, & High
Raise for cold, lower for hot
Coax or RJ45 CH A thru D
Sub menu to change
ON or OFF
Meter Menu
27
to open full menu
![Page 28: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/28.jpg)
TRACE OPTIONS
Z SCALE (OHMS) : 200TRACE RANGE : 50START DISTANCE : 0MICRO FAULT : OFFTEST LEAD NULL : OFFNOISE FILTER : OFF
Trace
20, 50, 100, 200, 500, & 1K
10ft – 20Kft (2m – 5Km)
Shifts display range by entry. 0 = TDR connector or Test Leadend if Test Lead Null ON
ON or OFF (slide 39 for details)ON or OFF
OFF, KINKS ONLY or ALL FAULTS (slides 37 & 38 for details)
Trace Menu
28
![Page 29: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/29.jpg)
Memory MenuMemory
MEMORY OPERATIONS
SAVERECALLPRIOR SETTINGS
ENTER MEMORY NAME‘0’ TO ‘9’: DIGIT OR CHARACTER : MOVE EDIT CURSOR : ERASE/START OVER‘ENTER’ : ACCEPT AND CONTINUE
**ENTER NAME* *
1 2 3
4 5 6
7 8 9
Bcksp 0
. , A B C D E F
G H I J K L M N O
PQRS T U V WXYZ
% & =
MEMORY RECALL OPERATION
* * * START OF LIST* * *LMR-400 ANT-2 Z50 VF 85.0RG-58 XMIT-6 Z50 VF 83.5RG-58 XMIT-8 Z50 VF 83.5CAT5 CONTL LINE Z100 VF 72.3LMR-400 ANT-1 Z50 VF 85.0* EMPTY SLOT*SAVED 30 AUG 2011 10:31AMENTER:SELECT SLOT, ESC:QUIT
29
Delete Trace – Highlight –CAUTION: NO UNDELETE
Bcksp
![Page 30: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/30.jpg)
Cables Menu
CABLE SELECTION
PICK/EDIT LISTMANUAL ENTRYVELOCITY SRCH.SAMPLE A CABLEDISTANCE UNITS: FEET
SELECTED CABLE:COMSCOPE .625 ZO 75 VF 87.0
Cables
Compute a cable’s VFby testing a sample ofknown length – guidedprocess
ENTER THE CABLE MANUALLY
DESCRIPTION : SAMPLEDCABLE Z0 : 50VELOCITY FACT. : 67.6
Find a cable’s VF from knownpoints – guided process
30
CABLES LIST***START OF LIST***GENERIC RG8/U Z0 52 VF 66.0TIMES RG6/U Z0 75 VF 66.0IW-CAT 3 24AWG Z0 100 VF 67.0IW-CAT 5 24AWG Z0 100 VF 70.0IW-CAT 5E 24AWG Z0 100 VF 72.0
‘ENTER’:SELECT THIS CABLE‘BCKSP’: EDIT CABLE ‘ESC’: QUIT
![Page 31: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/31.jpg)
Range
Minimum 10 ft or 2m
Maximum 20Kft or 5Km
Increase/decrease display range
31
![Page 32: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/32.jpg)
Zoom
Zoom Limits: Minimum 10ft (2m) to Maximum Set Range
Zooms on active cursor
32
![Page 33: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/33.jpg)
Z Scale
Scales: 20, 50, 100, 200, 500, & 1KΩ
On lower Scale settings cable Z0 will stay centered
33
![Page 34: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/34.jpg)
Single active cursor has LED litRules when both cursors are on screen:1. Both LEDs are lit2. Last cursor key touched is active3. Last cursor key touched appears on
LCD with differential readings to othercursor’s – distance and Ohms
Crsr 1 Crsr 2Crsr 2
34
![Page 35: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/35.jpg)
Tone
Tones generated on coax orselected twisted pair
Most standard inductiveamplifiers (probes) will pickup the tones
TDR trace is not availablewhile toning the cable.Battery Saver is suspended
Meter INPUT CHANNEL:
TONE GENERATOR‘ ‘,’ ‘: SELECT A DIFFERENT TONE‘BCKSP’: VIEW THE LIST OF TONES‘TONE’: EXIT TO TDR MODE
INJECTING A WARBLE TONE ONTO:RJ45 CH A
WARBLEPRESENT VALUE: 900/1100HZ Press for a menu of
Tones
Bcksp
35
TONE GENERATOR LIST900/1100 HZ WARBLE977.5 HZ STEADY977.5 HZ PULSED850 HZ STEADY850 HZ PULSED577 HZ STEADY577 HZ PULSED
Use onBattery poweronly
![Page 36: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/36.jpg)
E20/20 TDR Advanced Features
TraceMICRO FAULT – Locate minute defects in coaxTEST LEAD NULL – Remove unknown test lead length from measurement
CablesVELOCITY SEARCH – Pin-Point an installed cable’s
true VF based on cable’s known length or known distance to an event.
SAMPLE A CABLE – Find the VF for a cable sample to apply to all the cable in that box, reel or lot number.
36
![Page 37: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/37.jpg)
Micro Fault
Trace MICRO FAULT – KINKS ONLY
37
For small kinks and crushesin coax cablesTDR’s normal display will
shift to an amplified reflectiondisplay with Z0 as base line . In this example a fault barelyseen in the normal impedance display shows up clearly.
![Page 38: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/38.jpg)
Micro FaultTrace MICRO FAULT – ALL FAULTS
38
Mainly for coax or highquality twisted pairsTDR’s normal display will
shift to an amplified reflectionDisplay Z0 centered, no dribble-up & reduced Z Scale. In this example a fault barelySeen in the normal impedance display shows up clearly.
![Page 39: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/39.jpg)
Test Lead Null
Trace
TRACE OPTIONS
Z SCALE (OHMS) : 200TRACE RANGE : 50START DISTANCE : 0MICRO FAULT : OFFTEST LEAD NULL : OFFNOISE FILTER : OFF‘ ‘=OFF, ‘ ‘=ON,”ENTER”=SET NULL
Use a cursor to mark theEnd of the test lead and Press to set the length
ENTER
39
![Page 40: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/40.jpg)
Velocity SearchWhen to use – If you have an installed cable with known lengths either to the end or an event on the cable. E20/20 willcompute the cable’s VF based on marking the distance with acursor, then use the to adjust the cable end or event tothat distance.
Press when end ofcable and cursor are alignedto use the modified VF andreturn to Measurement Screen
ENTER
40
![Page 41: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/41.jpg)
Sample a CableWhen to use – If you have a cable sample 10-50ft (3-15m)with an accurately measured length, and plan to install or test cable’s from it’s same reel or box.
41
Mark the end of the sample.Press and enter ft then in.Press TDR computes VFENTER
![Page 42: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/42.jpg)
Transition from the Theoretical to the Practical
How can a TDR help you get a clear TV picture,a quality phone call or a fast internet connection
42
![Page 43: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/43.jpg)
Kitchen
Living RoomBedroom 1
Bedroom 2
Bedroom 3Kitchen
Living RoomBedroom 1
Bedroom 2
Bedroom 3
Typical Telco Loop Wiring NID
Telco USOC Wiring Scheme for Homesand Small Businesses
1 – T3 not connected2 – T2 Black3 – R1 Red4 – T1 Green5 – R2 YellowYellow6 – R3 not connected
RJ12 WiredUSOC
1 – T2 Black2 – R1 Red3 – T1 Green4 – R2 YellowYellow
RJ11 WiredUSOC
43
![Page 44: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/44.jpg)
NID
Kitchen
Living Room
Bedroom 1
Bedroom 2
Bedroom 3
Typical Star or Home Run Wiring
TIA 568C for Business Wiring or TIA 570B for Residential Wiring
66 Block or110 Block orConnectionBox
1 – T3 White/Green2 – T3 Green3 – T2 White/Orange4 – R1 Blue5 – T1 White/Blue6 – R2 Orange7 – R4 White/Brown8 – R4 Brown
RJ45 WiredT-568A
1 – T3 White/Orange2 – T3 Orange3 – T2 White/Green4 – R1 Blue5 – T1 White/Blue6 – R2 Green7 – R4 White/Brown8 – R4 Brown
RJ45 WiredT-568B
44
![Page 45: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/45.jpg)
AEA Technology Reduced All Wiring Schemes to Coax & 4 RJ45 Channels
99.9% of all phone lines will be on TDR’s Channel A or look at any other single pair
ETDR PC Vision can upload, modify, store & download cable lists to the E20/20 TDR
The E20/20 TDR in impedance independent and can test both coax and twisted pair cables with the same TDR The E20/20 TDR has a customized cable list for Telco techs that covers OSP cable, air or gel filled, drops and premises twisted pairs (IW) for Cat 2 through
Cat 6, and coax.
45
![Page 46: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/46.jpg)
0 160 320
200
150
100
50
0
CRSR1 291ft 10in 101.4 to 101.6
GENERIC 24AWG VF 66.7
0 160 320
200
150
100
50
0
CRSR1 291ft 10in 101.4 to 101.6
GENERIC 24AWG VF 66.7
Kitchen
Living RoomBedroom 1
Bedroom 2
Bedroom 3
Shorting Plug
Three Step Check1. Unplug all
phones2. Connect the
TDR at NID3. Locate end
jack using ashorting plug
Open and shortat end jack indicates a good pair run. Test canbe repeated for all pairs.
Results NID
46
![Page 47: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/47.jpg)
0 160 320
200
150
100
50
0
CRSR1 155ft 3in 101.4 to 101.6
GENERIC 24AWG VF 66.7
0 160 320
200
150
100
50
0
CRSR1 155ft 3in 101.4 to 101.6
GENERIC 24AWG VF 66.7
Three Step Check1. Unplug all
phones2. Connect the
TDR at NID3. Locate last
visible jack using a shorting
plugFault is a brokenwire after the jackconnection inBedroom 1’s jack
Results
Kitchen
Living RoomBedroom 1
Bedroom 2
Bedroom 3
NID
Shorting Plug
Shorting Plug
Shorting Plug
47
![Page 48: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/48.jpg)
Kitchen
Living RoomBedroom 1
Bedroom 2
Bedroom 3
NID
0 160 320
200
150
100
50
0
CRSR1 174ft 7in 101.5 to 101.8
GENERIC 24AWG VF 66.7
Three Step Check1. Unplug all
phones2. Connect the
TDR at NID3. Note short at
Bedroom 2with no shortingplug.
Look for bent pinsor shorted wiresinside the jack
Results
48
![Page 49: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/49.jpg)
Premises Advantage of a TDR? Quickly locate the distance to a fault and see type of fault
Stop rewiring premise twisted pairs when a simple 5 minutefix will clear the trouble
95% of all premise telco wiring problems are in the jacks
1. Customer pulled out jack and broke a wire
2. Customer rewired jack and disrupted service
3. Bent or broken pins
4. Cat marked territory and corroded jack pins
49
![Page 50: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/50.jpg)
OSP Testing and Fault Locating
Example Range Resolutions: 10ft=0.5inch, 500ft=2ft, 2000ft=8ftUse “Zoom” to improve horizontal resolution at cursorUse “Z Scale” to increase vertical resolution – Minimum +10 Ohms
Measure Cable’s Impedance (Z) & Resistance (Ω) “Dribble Up”
Use Noise Filter to clear the trace from noise. Yes! Detects Noise
Locates Distance and Impedance effects for:Poor Splices Bad ConnectionsSeries Resistance Cable DamageWet Cable Load CoilsImpedance Mismatches Lossy Cable
Ranges: 0-10ft to 0-20Kft
50
![Page 51: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/51.jpg)
Water in OSP CablingWater Rules1. Reduces the resistance ofthe wire’s insulation -Hence reduces cable’s Z.2. Reduces velocity to anunknown – Distances in awater slug or after the slug areNOT valid.
1374 ft
464 ft water599 ft 311 ft
51
Wet Cable
Only trusted distanceis TDR to start of water
![Page 52: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/52.jpg)
Cross Connects, Pedestals,And Splices
52
Add screen shots
![Page 53: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/53.jpg)
Questions on E20/20 TDR?
53
Next subject – ETDR PC Vision
![Page 54: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/54.jpg)
ETDR PC VisionTM SoftwareOperates on: Windows XP®, Windows 7® or Vista® Platforms
Upload TDR’s saved or current traces to the PC
Archive the traces on the PC or other memory media
No platform license – Load on any number of PC’s
Upload and Download Cable Lists to the E20/20 TDR
Upload and Download instrument setups to the E20/20 TDR
54
![Page 55: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/55.jpg)
Getting Started with ETDR PC Vision1. Locate ETDR PC Vision folder on the enclosed CD-ROM
or download it from www.aeatechnology.com
2. Turn on the E20/20 TDR and wait for the MeasurementScreen (will not communicate if off or in menus).
4. Double-click the icon on the desktop to open application
3. Connect the TDR and PC using the supplied USB Cable
55
![Page 56: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/56.jpg)
User Friendly Communications SetupETDR PC Vision automatically scans for the E20/20 TDR when it opens
56
FTDI DriversMay need to beinstalled. Driversare located on enclosed CDand instructionsare in the Operator Manual.
![Page 57: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/57.jpg)
Get Trace Tab
57
TDR’s currentLCD trace
Open a previouslysaved trace onthe PC or otherstorage media.Usable withoutTDR connected
![Page 58: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/58.jpg)
Stored Traces Tab
ANTENNA 2 50 78.6 12/30/11 11:58ANTENNA 5 50 78.6 12/30/11 12:26CON. 401 100 67.7 1/3/12 07:39CON. 331 100 67.7 1/3/12 08:38SENSOR 6-1 100 72.3 1/5/12 09:11SENSOR 6-2 100 72.3 1/5/12 09:15FLIR 1 75 74.8 1/10/12 10:27
58
Press first toupload a listof stored traces
Direct save TDRmemory to PCfolderCaution – There is NO UNDELETE
![Page 59: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/59.jpg)
Graphic Plot Screen
59
![Page 60: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/60.jpg)
Setup Tab
60
Press eitherto obtainvalid data(gray text is not valid)
![Page 61: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/61.jpg)
Cables TabRead the CableList from TDRor from a stored list on thePC
Use these keys and “Select Cable Values” to edit the list
Write the CableList to the TDRor to a stored liston the PC
61
![Page 62: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/62.jpg)
Cleaning Your 20/20 TDR1. Always spray cleaners and rinse water on a soft cloth, do NOT
spray directly on the TDR
Soft CasesThe soft case should be cleaned the same as the instrument. Usea soft bush to remove tough dirt. Do NOT immerse in water or dryin a dryer. Wash and Dry separately, both instrument and case should be dry before enclosing the instrument in the case.
2. Typical Grime – Use a mild non-abrasive detergent like 409® in water or glass cleaner (non-ammonia) and rinse water to clean
3. Cable Gel – User liquid “citrus” cleaner to remove
4. Tar, creosote or adhesives – Use WD40® followed with milddetergent and water
62
![Page 63: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/63.jpg)
Maintenance, Service and WarrantyBasic Guide or Operator Manual, Maintenance, Service & Warranty.
Warranty – One year against material & workmanship defects
Questions, By all means – Contact us:
AEA Technology, Inc.5933 Sea Lion Place, Ste 112Carlsbad, CA 92010Tel: 800-258-7805 or +1-760-931-8979Fax: +1-760-931-8969
www.aeatechnology.comEmail
Application Notes
Operating Manuals
TDR PC VisionData Sheets
See “User Troubleshooting Guide”
63
Quick Start Guide
![Page 64: E20/20 Step TDR CATV Operator Training January 24, 2012 Rev B – 11/21/12](https://reader037.vdocuments.us/reader037/viewer/2022110320/56649cb75503460f9497ca3b/html5/thumbnails/64.jpg)
Questionson
E20/20 Step TDR ETDR PC Vision software?
Windows 7, Vista, and Windows XP are registered trademarks of Microsoft® Corp.409 is a registered trademark of Clorox® Corp.WD-40 is a registered trademark of WD-40® company
64