8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 1/38
REFERENCE NUMBER :
GE Energy
ECH / SCALE
FORMAT / SIZ E
DATE
NOM / NAME
VISA
TITRE / TITLE
REDIGE / MADE APPROUVE / APPROVEDVERIFIE / CHECKED
REVISION
INSTRUCTION DE MODIFICATION
Section Doc .
N
SHEET. N
Ce document, propriété exclusive deGE Energy Products France SNC
est strictement confidentiel. Il ne peutêtre communiqué, copié ou reproduitsans son autorisation écrite préalable
This document, exclusive property of GE Energy Products France SNC
is strictly confidential. It must not becommunicated, copied or reproducedwithout our previous written consent.
REVISION :
MEGA DEAL PROJECT D
GRD
None
A4
IM-2010005680
21/09/2010 29/09/2010 29/09/2010
394A1633
LIMMACHER STEPHANE FREY CHRISTELLE CHEVALIER STEPHANE
CHEVALIER STEPHANEFREY CHRISTELLELIMMACHER STEPHANE
M A R I O T T O
E V E L Y N E V A L I D E
X
E0878 CF0 --- ES 001
PAINTING-EQUIPMENT SPECIFICATION
GENERAL PAINTING SPECIFICATION
A
B
1 9 - O c t - 2 0 1 0 - 0
7 : 3 8
GE O
fficial
FOR
PPROV L
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 2/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
Reference : 394A1633 Rev. : B Section : 01 Page : 1 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
S U M M A R Y
1. SPECIFICATION OF ANTI-CORROSION PROTECTING SYSTEMS APPLIED ON THE VARIOUSEQUIPMENT MENTIONED HEREUNDER ___________________________________________________ 4
1.1. TYPE OF PRODUCTS USED ______________________________________________________________ 41.1.1. Primer coat _______________________________________________________________________________41.1.2. Final coat_________________________________________________________________________________41.1.3. Painting supplier ___________________________________________________________________________41.1.4. Remarks _________________________________________________________________________________41.1.5. Protection of machined surfaces and bored holes________________________________________________51.1.6. Surface protection _________________________________________________________________________51.1.7. Tolerances of thickness values _______________________________________________________________6
1.2. RELEVANT SYSTEM ____________________________________________________________________ 7
2. SUMMARY_______________________________________________________________________ 10
1 GAS TURBINE AND DIRECT AUXILIARIES _____________________________________________________ 10100 GAS TURBINE AND DIRECT AUXILIARIES____________________________________________________________10ITEM 0901 BASE FRAME ____________________________________________________________________________10ITEM 0991 GAS MODULE ___________________________________________________________________________10ITEM 1605 GAS TURBINE OFF-BASE ENCLOSURE, 88TK EXHAUST FRAME BLOWERS ENCLOSURE_________________ITEM 1612 PLENUM ASSEMBLY, INLET _________________________________________________________________14ITEM 1617 LOAD COMPARTMENT – ON BASE ENCLOSURE_________________________________________________15ITEM 1625 PLENUM ASSEMBLY, EXHAUST______________________________________________________________15ITEM 1658 GAS MODULE OFF-BASE ACOUSTIC ENCLOSURE _______________________________________________16ITEM 1659 WATER INJECTION SKID OFF-BASE ACOUSTICAL ENCLOSURE_____________________________________18ITEM A014 TURBINE CONTROL PANEL _________________________________________________________________20ITEM A016 GENERATOR CONTROL PANEL ______________________________________________________________20ITEM A035 WATER INJECTION SKID ___________________________________________________________________20ITEM A040 AIR FILTER ______________________________________________________________________________21
ITEM A041 INLET DUCT_____________________________________________________________________________22ITEM A042 EXHAUST EXTENSION _____________________________________________________________________22ITEM A053 PIPING ARRANGEMENT, INTERCONNECTION FIELD _____________________________________________23ITEM A065 TURBINE AUXILIARY PANEL ________________________________________________________________23ITEM A098 OIL MIST ELIMINATOR SKID ________________________________________________________________23ITEM A108 EQUIPMENT NETWORK TOPOLOGY __________________________________________________________23ITEM A980 INLET SUPPORTING STRUCTURES ___________________________________________________________23ITEM E048 ADDITIVE INJECTION SKID _________________________________________________________________24ITEM E026 TURBINE CLEANING ______________________________________________________________________24ITEM MS99 EXHAUST PLENUM MODULE _______________________________________________________________24ITEM 969A INTERCONNECTION PIPING, LUBE OIL _______________________________________________________24ITEM 969G INTERCONNECTION PIPING, GAS FUEL _______________________________________________________24222 INSULATION UNDER EXHAUST ___________________________________________________________________25
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 3/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
Reference : 394A1633 Rev. : B Section : 01 Page : 2 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
240 GT UNIT FIRE FIGHTING SYSTEM __________________________________________________________________25241 GTG FIRE FIGHTING CONTROL PANEL______________________________________________________________25
266 GENERATOR ACOUSTIC BARRIER WALL ____________________________________________________________25270 SUMP TANK __________________________________________________________________________________27280 TURBINE WASHING ____________________________________________________________________________272C1 LIGHT DISTILLATE OIL FORWARDING SKID__________________________________________________________272C2 HEAVY OIL FORWARDING SKID___________________________________________________________________272D1 LIGHT DISTILLATE OIL FILTERING SKID_____________________________________________________________282D2 HEAVY OIL FILTERING SKID______________________________________________________________________282F6 WALKWAYS __________________________________________________________________________________282G0 & G025 GT GAS FUEL SUPPLY____________________________________________________________________282J0 GT AIR PROCESSING UNIT _______________________________________________________________________28
4 EXHAUST SYSTEM ________________________________________________________________________ 29422 LATERAL EXHAUST_____________________________________________________________________________29
425 ELBOW AND DOWNSTREAM DUCTING_____________________________________________________________29432 EXHAUST STACK ON SIDE EXHAUST _______________________________________________________________30460 SCREEN AT GT EXHAUST FOR PERSONNEL PROTECTION_______________________________________________31
5 GENERATOR & ENERGY EVACUATION _______________________________________________________ 31510 GT GENERATOR _______________________________________________________________________________31530 GT UNIT CIRCUIT BREAKER ______________________________________________________________________31543 GENERATOR ACCESSORY COMPARTMENT __________________________________________________________31560 MV BUS DUCTS _______________________________________________________________________________32
8 COOLING SYSTEM________________________________________________________________________ 33811 SIMPLE CYCLE FIN FAN COOLERS _________________________________________________________________33
9 PIPING SYSTEM __________________________________________________________________________ 33
910 PIPING ______________________________________________________________________________________33B GT CONTROL & LV DISTRIBUTION __________________________________________________________ 35
B10 PACKAGED ELECTRONIC & ELECTRICAL CONTROL CABINET (PEECC) _____________________________________B51 GT & GENERATOR AUXILIARIES LV DISTRIBUTION (MCC) _______________________________________________36B52 125 V DC BATTERY CHARGER CUBICLE_____________________________________________________________36B53 125 V DC BATTERY_____________________________________________________________________________36
ELECTRICAL MOTORS PUMPS FANS VALVES & IN LINE INSTALLED EQUIPMENTS AND DEVICES _________ 37
MANUTENTION & MAINTENANCE TOOLS ______________________________________________________ 37
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 4/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
Reference : 394A1633 Rev. : B Section : 01 Page : 3 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
STATE OF MODIFICATIONS
INDEX DATE DESCRIPTIONA 23/10/2008 First issue
B 21/09/2010 General update : Jotun painting systems applied on allequipments except Gas Turbine, scope updated
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 5/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
Reference : 394A1633 Rev. : B Section : 01 Page : 4 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
1. SPECIFICATION OF ANTI-CORROSION PROTECTING SYSTEMS APPLIED ON THE VARIOUSEQUIPMENT MENTIONED HEREUNDER
1.1. TYPE OF PRODUCTS USED
1.1.1. Primer coatP(H) HEMPADUR 45880 or 47200 Colour Red 50630
or Grey 12170 (Hempadur 45880) , white73640 (Hempadur 47200) (cf §1.1.4)
P2(H) HEMPEL’S GALVOSIL 15700 Colour Grey 19840P8(H) HEMPEL'S SILICONE ZINC PRIMER 16900 Colour Grey 19840P PENGUARD EXPRESS Colour Buff or OffWhite (cf.§1.1.4.)P1 TANKGUARD STORAGE Light redP4 JOTACOTE UNIVERSAL AluminiumP8 RESIST 78 Colour greyPEPZn Barrier 77 Colour grey
1.1.2. Final coatF (H) HEMPATHANE 55910 or 55610 Refer to column FINAL COLOUR in §2F8(H) HEMPEL'S SILICONE ALUMINIUM 56910 Aluminium 19000F HARDTOP XP Refer to column FINAL COLOUR in §2F1 TANKGUARD STORAGE Light greyF4 JOTACOTE UNIVERSAL GreyF8 SOLVALITT AluminiumF9 SOLVALITT MIDTHERM AluminiumF10 JOTUN ANTI SKID
1.1.3. Painting supplierHempel and Jotun products are available all over the world (same composition, same quality, sameguarantee).To know the address of the nearest vendor, you can contact: Hempel and/or Jotun France to thefollowing address
HEMPEL PEINTURES France60149 SAINT CREPIN IBOUVILLERSTel : (+33) (0) 3 44 08 28 90
JOTUN France S.A.S.22/24 Rue Du President Wilson Bat. A92300 LEVALLOIS-PERRETTel : (+33) (0)1 45 19 38 82
1.1.4. Remarks§ Refer to data sheets of products here above mentioned§ All the operations of applying anti-corrosion protection coating stated before are carried out
according to the standard general specification 91–421666
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 6/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
Reference : 394A1633 Rev. : B Section : 01 Page : 5 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
§ All instructions concerning anti-corrosion protection for Gas Turbine and closed auxiliaries arecarried out according to the standard general specification 91-411810
§ All instruction concerning hot dip galvanized coatings fabricated iron and steel articles arecarried out according to ISO 1461 : Hot dip galvanized coatings fabricated iron and steel articles- specification and methods and ISO 14713 : Protection against corrosion of iron and steel instructure – zinc and aluminium coatings – guidelines.
§ When hot dip galvanized steel to be painted: before applying the GEEPE system (D, E …) add aprimer coat (50 microns) of Penguard Express (P).
§ When aluminium or copper to be painted: before applying the GEEPE system (D, E …) add aprimer coat (50 µm) of Penguard Express (P).
§ When thin sheet metals (< 4 mm), carbon steel are used, and if abrasive blasting Sa 2.5 is notpossible, we required mechanical preparation of surface to obtain degree of cleaning St3 definedby standard ISO 8501-1. And before applying the GEEPE system (D, E …) add a primer coat (50µm) of Penguard Express (P).
§ When the final coat colour shade is selected and pale (white or cream) use a primer coat of Greyor white instead of Red or Buff.
§ For MSD equipments, estimated surface is for one GT.
For BOP equipments, estimated surface is for the plant.§ For the round bar of ladders apply anti-skid system S2.
1.1.5. Protection of machined surfaces and bored holesThreading : product leaving an oily or greasy filmMachined surfaces : product leaving a waxy film
1.1.6. Surface protection
The surface protection applied on external carbon steel cold surfaces for outdoor equipmentincluded supplier standard protection i s defined for an atmospheric corrosivity categories C3(medium) and a High durability (H : more than 15 years) in accordance with ISO 12944.
For other specific surfaces (GT casing, hot surfaces, reservoir, etc…) please refer to §1.2.
The surface protection system is designed such that over the first 5 years the surfaces will notdegrade more than the following levels:
• degree of rusting - less than the degree of rusting Ri2, defined in the standard ISO
4628/3• changes in appearance - default density : less than 0.5% of the surface for an inspected
surface of at least 1 m²
• adherence - less than or equal to classification 2 of the standard ISO 2409 - pull-off resistance greater than or equal to 1.5 MPa.
The indications above do not apply to specific systems subject to particular temperature (systems Hand L and M applied on GT casing, hot surfaces, reservoir, etc…).
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 7/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
Reference : 394A1633 Rev. : B Section : 01 Page : 6 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
1.1.7. Tolerances of thickness valuesRefer to 91-421666
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 8/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
Reference : 394A1633 Rev. : B Section : 01 Page : 7 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
1.2. RELEVANT SYSTEM
TYPE L(H) M(H) N(H)
PROTECTED SURFACES Very hot surfaces(150°C < T° < 500°C)
GT External surfaces of casing
Inlet Belmouth air flowsurfaces
Nominal dry thickness P8(H) : 40 µmF8(H) : 25 µm
P2(H) : 75 µmF8(H) : 25 µm
P2(H) : 75 µmP(H) : 30 µmF(H) : 80 µm
Min. dry thickness P8(H) : 32 µmF8(H) : 20 µm
P2(H) : 60 µmF8(H) : 20 µm
P2(H) : 60 µmP(H) : 24 µm
F(H) : 64 µm C o m p o s i t i o n
Max. dry thickness P8(H) : 60 µmF8(H) : 35 µm
P2(H) : 125 µmF8(H) : 35 µm
P2(H) : 125 µmP(H) : 45 µmF(H) : 120 µm
SYSTEM STANDARDS
§ HEMPEL’S SILICONE ZINC16900§ HEMPEL’S SILICONEALUMINIUM 56910
§ HEMPELS GALVOSIL15700§ HEMPEL’S SILICONEALUMINIUM 56910
§ HEMPELS GALVOSIL15700§ HEMPADUR 45880 or47200§ HEMPATHANE 55910 or55610
Touch up N.A. System L(H)Same product as systemdefined above
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 9/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
Reference : 394A1633 Rev. : B Section : 01 Page : 8 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
TYPE A A1 A' B
PROTECTED SURFACESInsulated equipment(T° < 200°C) exceptedacoustical panel
Insulated equipment(T° < 150°C) acousticalpanel
Insulated equipment(200°C < T < 500°C)
All internal surfaces of equipment andexternal surfacesinstalled withinbuilding
Nominal dry thickness P1 : 125 µm P : 125 µm P8 : 50 µmP : 80 µmF : 40 µm
Min. dry thickness P1 : 100 µm P : 100 µm P8 : 40 µmP : 64 µmF : 32 µm
C o m p o s i t i o n
Max. dry thickness P1 : 187 µm P : 187 µm P8 : 75 µmP : 120 µmF : 60 µm
SYSTEM STANDARDS § TANKGUARD
STORAGE § PENGUARD EXPRESS § RESIST 78
§ PENGUARD EXPRESS§ HARDTOP XP
Touch up Same product assystem defined above
Same product assystem defined above
Primer touch up withSolvalitt Zn (2X30µm).
Same product assystem defined above
TYPE D E H S2
PROTECTED SURFACES
All external surfacesof equipmentexposed to a mild ormedium aggressiveenvironment
All external surfaces of equipment exposed to avery aggressiveenvironment(Maritimes, industrials,corrosive)
Internal surfaces of fuel oil and watertanks
Surfaces of cheked platesand/or round barof ladders
Nominal dry thickness P: 100 µmF : 40 µm
P: 180 µmF : 40 µm
P4 : 150 µmF4 : 150 µm
F : 65 µm with F101,5-2 kg per 10litres
Min. dry thickness P : 80 µmF : 32 µm
P : 144 µmF : 32 µm
P4 : 120 µmF4 : 120 µm
F : 52 µmF10 : 1,5-2 kg per10 litres
C
o m p o s i t i o n
Max. dry thickness P : 150 µmF : 60 µm
P : 270 µmF : 60 µm
P4 : 225 µmF4 : 225 µm
F : 98 µmF10 : 1,5-2 kg per10 litres
SYSTEM STANDARDS § PENGUARD EXPRESS
§ HARDTOP XP
§ PENGUARD EXPRESS§ HARDTOP XP
§ JOTACOTEUNIVERSAL§ JOTACOTEUNIVERSAL
§ PENGUARDEXPRESS ANDJOTUN ANTI SKID
Touch up Same product assystem defined above
Same product as systemdefined above
Same product assystem definedabove
Same product assystem definedabove
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 10/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
Reference : 394A1633 Rev. : B Section : 01 Page : 9 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
TYPE S1
PROTECTED SURFACES External surfaces of exhaust duct
Nominal drythickness
P8 : 60 µmF9 : 30 µm
Min. dry thickness P8 : 48 µm
F9 : 24 µm C o m
p o s i t i o n
Max. dry thickness P8 : 90 µmF9 : 45 µm
SYSTEM STANDARDS§ RESIST 78§ SOLVALITT
MIDTHERM
Touch up
Primer touch up withSolvalitt Zn (2X30µm).Same productfor final coat.
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 11/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 1 0 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
2. SUMMARY
ITEM EQUIPMENT SYSTEMTYPE SHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINALCOLOUR REMARKS
1 GAS TURBINE AND DIRECT AUXILIARIES
100 GAS TURBINE AND DIRECT AUXILIARIES
A External cold surfaceT° < 150°C B P
F / / GreyRAL 7035 (1)
B
Internal air inlet surface
(Bellmouth)T° < 150°C N(H)
P2(H)
P(H)F(H) / /Blue
RAL 5012 (1)
C Trunnion lifting baseT°< 150°C B P
F / / YellowRAL 1028 (1)
D Oil tank internal surfacesT° < 150°C B P
F / / GreyRAL 7035
E All casing outside surfacesT>200°C M(H) P2(H)
F8(H) / / Alu 19000 (1)
ITEM 0901 BASE FRAME
A External cold surfaceT°< 150°C B P
F / / Light GreyRAL 7035
BInside base (Auxcompartment)T°< 150°C
B PF / / Light GreyRAL 7035
CInside base (Turbinecompartment)T°< 180°C
B PF / / Light Grey
RAL 7035
D Trunnion lifting baseT°< 150°C B P
F / / YellowRAL 1028
E Walkways supportsT°< 150°C B P
F / / YellowRAL 1023
ITEM 0991 GAS MODULE
A Base Frame surfaces E P
F/ / RAL 9002 (1)
B Other surfaces T<150°C B PF / / RAL 9002
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 12/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 1 1 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
C Junction boxes / X / / / Supplierstandard
D Trunnion lifting base E PF / / Yellow
RAL 1028 (1)
E Hot surfaces T>150°C L P8F8 / / Aluminium (1)
ITEM 1605 GAS TURBINE OFF-BASE ENCLOSURE, 88TK EXHAUST FRAME BLOWERS ENCLOSURE
A STEEL STRUCTURES insideroofed compartments B P
F / / GreyRAL 7035 (1) (3)
B STEEL STRUCTURESoutside compartments E P F (50) GreyRAL 7035
SandblastedSA2.5
C STEEL STRUCTURES insidenon roofed compartments E P
F / / GreyRAL 7035 (1) (4)
D GRATING inside andoutside compartments / X / / /
Hot dipgalvanised
steel
EHANDRAILS, LADDERSinside roofedcompartments
B PF / / Grey
RAL 7035 (1) (3)
F HANDRAILS, LADDERSoutside compartments E P F (50) Grey
RAL 7035
Sandblasted
SA2.5G
HANDRAILS, LADDERSinside non roofedcompartments
E PF / / Grey
RAL 7035 (1) (3)
H
Perforated steel sheetsPANELS OF ROOF ANDWALL of roofedcompartmentsDOORS AND HATCHES of roofed compartmentsAIR VENTILATION DUCTS(T<150°C)
/ X / /Grey
RAL 9002(5)
Galvanisedand pre-paintedsteel (1)
or hot dipgalvanised
steel
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 13/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 1 2 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
I
Perforated steel sheetsPANELS OF WALL of nonroofed compartments
DOORS AND HATCHES of non roofed compartmentsAIR VENTILATION DUCTS(T≥ 150°C)
/ X / / /
Identical toitem H for
indoorinstallation
or forinstallation
in a noncorrosive
environment.
Systemresistant to
temperatureand to
corrosion(particularly
in theperforation)
in acorrosive
environment.)
J
Internal surfaces underacoustical treatmentPANELS OF ROOF ANDWALLDOORS AND HATCHES
A1 P / / Buff
Sand
blastedSA2.5or
Zinc platedsheet (1)
K
External surfaces insideroofed compartmentsand portion of externalsurfaces of edgesPANELS OF ROOF ANDWALL
B PF / /
GreyRAL 9002
(5)
SandblastedSA2.5 or
zinc platedsheets (1)
L
External surfaces insidenon roofed compartmentsand portion of externalsurfaces of edgesPANELS OF WALL
E PF / /Grey
RAL 9002(5)
(1) (3)
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 14/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 1 3 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
M
External surfaces outsidecompartmentsand portion of externalsurfaces of edgesPANELS OF ROOF ANDWALL
E P F (600) GreyRAL 7035
Sandblasted SA2.5 or zinc
platedsheets (1)
NExternal surfaces outsidecompartments DOORSAND HATCHES
E P F (30)Signalyellow
RAL 1003
SandblastedSA2.5 or
zinc platedsheet (1)
OMISCELLANEOUS (partitionwalls, …) inside roofedcompartment
B PF / /
GreyRAL 9002
(5)
Zinc platedsheet (1) (3)
PMISCELLANEOUS (partitionwalls, …) inside non roofedcompartments
E PF / /
GreyRAL 9002
(5)
Zinc platedsheet (1)
Q
Edges and externalsurfaces inside
compartmentsDOORS AND HATCHES
E P
F/ /
GreyRAL 9002
(5)(1)
VENTILATION
A
Internal surfaces underacoustical treatmentAIR VENTILATION DUCTS(T<150°C)
A1 P / / Buff (1)
B
Internal and externalsurfaces inside roofedcompartmentsAIR VENTILATION DUCTS(T<150°C)
B PF / / Grey
RAL 7035 (1)
C
Internal surfaces in nonroofed compartmentsAIR VENTILATION DUCTS(T<150°C)
B PF / / Grey
RAL 7035 (1)
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 15/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 1 4 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
D
External surfaces in nonroofed compartmentsAIR VENTILATION DUCTS(T<150°C)
E PF / / Grey
RAL 7035 (1)
E
Internal surfaces outsidecompartmentsAIR VENTILATION DUCTS(T<150°C)
B PF / / Grey
RAL 7035 (1)
F
External surfaces outsidecompartmentsAIR VENTILATION DUCTS(T<150°C)
E P F (50) GreyRAL 7035 (1)
G
Internal and externalsurfaces withoutacoustical treatmentAIR VENTILATION DUCTS(T≥ 150°C)
S1 P8F9 / / Aluminium (1)
H FANS AND ELECTRICALMOTORS / X / / / Supplier
standard
I DAMPERS / X / / / Supplierstandard
J BOLTS, WASHERS, NUTS / X / / /
Galvanisedsteel
or zincplated steel
or otherapproved
system
K HOISTING APPLIANCES / X / / / Supplierstandard
LInternal and externalsurfacesCO2 PIPING
/ X / / /
Galvanisedsteel (orstainlesssteel if
applicable)
ITEM 1612 PLENUM ASSEMBLY, INLET
A Internal surfaces withoutnoise insulation parts E P
F / / GreyRAL 7038
(1)
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 16/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 1 5 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
B Internal surfaces withnoise insulation parts A P1 / / Light red (1)
C All external surfaces E P F 500 Grey WhiteRAL 9002
Duckboardin hot dip
galvanisedsteel are
not painted
ITEM 1617 LOAD COMPARTMENT – ON BASE ENCLOSURE
A
Internal surfaces under
acoustical treatmentsACOUSTIC PANELS OFWALL, ROOF, BOTTOM ANDDOORS (T≥ 150°C)
/ X / / / Galvanisedsteel plate
B
Perforated steel sheetsACOUSTIC PANELS OFWALL, ROOF, BOTTOM ANDDOORS (T≥ 150°C)
/ X / / /
Galvanisedsteel plateor stainless
steel
C
External surfaces insideLoad compartmentACOUSTIC PANELS OFWALL, ROOF, BOTTOM ANDDOORS (T≥ 150°C)
/ X / / / Galvanisedsteel plate
D SEALING PLATES / X / / / Galvanisedsteel plate
E RUNGS, HANDRAIL / X / / / Galvanisedsteel plate
F
Internal and externalsurfaces withoutacoustical treatmentsU BEAM FOR ROOFSUPPORT (T≥ 150°C)SQUARE PROFIL OF RIGHTAND LEFT BEAMS (T≥ 150°C)BEAMS FORV BOTTOM
PANEL SUPPORT (T≥ 150°C)
S1 P8F9 / / Aluminium (1)
ITEM 1625 PLENUM ASSEMBLY, EXHAUST
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 17/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 1 6 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
A
Internal surfaces (withsurfaces under acousticaltreatments and hollowbodies)
S P8 / / /Stainless
steel is notpainted
B External surfaces S1 P8F9 / / /
Stainlesssteel is not
painted
ITEM 1658 GAS MODULE OFF-BASE ACOUSTIC ENCLOSURE
A STEEL STRUCTURES inside
roofed compartmentsB P
F/ / Grey
RAL 7035(1) (3)
B STEEL STRUCTURESoutside compartments E P F (50) Grey
RAL 7035
SandblastedSA2.5
C GRATING inside andoutside compartments / X / / /
Hot dipgalvanised
steel
D HANDRAILS, LADDERSoutside compartments E P F (50) Grey
RAL 7035
SandblastedSA2.5
E
Perforated steel sheetsPANELS OF ROOF ANDWALL of roofedcompartmentsDOORS AND HATCHES of roofed compartmentsAIR VENTILATION DUCTS(T<150°C)
/ X / / GreyRAL 9002(5)
Galvanisedand pre-
paintedsteel (1)or hot dip
galvanisedsteel
F
Internal surfaces underacoustical treatmentPANELS OF ROOF ANDWALLDOORS AND HATCHES
A1 P / / Buff
SandblastedSA2.5
orZinc plated
sheet (1)
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 18/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 1 7 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
G
External surfaces insideroofed compartmentsand portion of externalsurfaces of edgesPANELS OF ROOF ANDWALL
B PF / / Grey
RAL 9002
SandblastedSA2.5 or
zinc platedsheet (1)s
H
External surfaces outsidecompartmentsand portion of externalsurfaces of edgesPANELS OF ROOF ANDWALL
E P F (50) GreyRAL 7035
Sandblasted SA2.5 or zinc
plated
sheets (1)
IExternal surfaces outsidecompartments DOORSAND HATCHES
E P F (12)Signalyellow
RAl 1003
SandblastedSA2.5 or
zinc platedsheet (1)
J
Edges and externalsurfaces insidecompartmentsDOORS AND HATCHES
E PF / /
GreyRAL 9002
(5)(1)
VENTILATION
A
Internal surfaces under
acoustical treatmentAIR VENTILATION DUCTS(T<150°C)
A1 P / / Buff (1)
B
Internal and externalsurfaces inside roofedcompartmentsAIR VENTILATION DUCTS(T<150°C)
B PF / / Grey
RAL 7035 (1)
C
Internal surfaces outsidecompartmentsAIR VENTILATION DUCTS(T<150°C)
B P
F/ / Grey
RAL 7035(1)
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 19/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 1 8 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
D
External surfaces outsidecompartmentsAIR VENTILATION DUCTS(T<150°C)
E P F (50) GreyRAL 7035 (1)
E FANS AND ELECTRICALMOTORS / X / / / Supplier
standard
F DAMPERS / X / / / Supplierstandard
G BOLTS, WASHERS, NUTS / X / / /
Galvanisedsteel
or zincplated steel
or otherapproved
system
HInternal and externalsurfacesCO2 PIPING
/ X / / /
Galvanisedsteel (orstainlesssteel if
applicable)
ITEM 1659 WATER INJECTION SKID OFF-BASE ACOUSTICAL ENCLOSURE
A STEEL STRUCTURES inside
roofed compartmentsB P
F/ / Grey
RAL 7035(1) (3)
B GRATING inside andoutside compartments / X / / /
Hot dipgalvanised
steel
C
Perforated steel sheetsPANELS OF ROOF ANDWALL of roofedcompartmentsDOORS AND HATCHES of roofed compartmentsAIR VENTILATION DUCTS(T<150°C)
/ X / /Grey
RAL 9002(5)
Galvanisedand pre-paintedsteel (1)
or hot dipgalvanised
steel
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 20/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 1 9 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
D
Internal surfaces underacoustical treatmentPANELS OF ROOF ANDWALLDOORS AND HATCHES
A1 P / / Buff
SandblastedSA2.5
orZinc plated
sheet (1)
E
External surfaces insideroofed compartmentsand portion of externalsurfaces of edgesPANELS OF ROOF ANDWALL
B PF / /
GreyRAL 9002
(5)
SandblastedSA2.5 or
zinc plated
sheets (1)
F
External surfaces outsidecompartmentsand portion of externalsurfaces of edgesPANELS OF ROOF ANDWALL
E P F (60) GreyRAL 7035
Sandblasted SA2.5 or zinc
platedsheets (1)
GExternal surfaces outsidecompartments DOORSAND HATCHES
E P F (9)Signalyellow
RAL 1003
SandblastedSA2.5 or
zinc platedsheet (1)
HEdges and externalsurfaces insidecompartmentsDOORS AND HATCHES
E PF / /
GreyRAL 9002
(5)(1)
VENTILATION
A
Internal surfaces underacoustical treatmentAIR VENTILATION DUCTS(T<150°C)
A1 P / / Buff (1)
B
Internal and externalsurfaces inside roofedcompartmentsAIR VENTILATION DUCTS(T<150°C)
B P
F/ / Grey
RAL 7035(1)
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 21/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 2 0 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
C
Internal surfaces outsidecompartmentsAIR VENTILATION DUCTS(T<150°C)
B PF / / Grey
RAL 7035 (1)
D
External surfaces outsidecompartmentsAIR VENTILATION DUCTS(T<150°C)
E P F (50) GreyRAL 7035 (1)
E FANS AND ELECTRICALMOTORS / X / / / Supplier
standard
F DAMPERS / X / / / Supplierstandard
G BOLTS, WASHERS, NUTS / X / / /
Galvanisedsteel
or zincplated steel
or otherapproved
system
HInternal and externalsurfaces
CO2 PIPING
/ X / / /
Galvanisedsteel (orstainless
steel if applicable)
ITEM A014 TURBINE CONTROL PANEL
A Speedtronic / X / / GreyRAL 7035
ITEM A016 GENERATOR CONTROL PANEL
A Générator control panel / X / / GreyRAL 7035
ITEM A035 WATER INJECTION SKID
A Frame B PF / / Grey
RAL 7035 (1)
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 22/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 2 1 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
B Steam piping L P8F8 / / Aluminium
Stainlesssteel piping
is notpainted
C Trunnion lifting base B PF / / Yellow RAL
1028 (1)
D Water piping D PF / / Grey
RAL 7035
Stainlesssteel piping
is notpainted
ITEM A040 AIR FILTER
A
Internal surfaces clean airside:Clean air housing sheetsTransition duct sheetsInternal structure
D PF / / Grey
RAL 7038 (1)
B Dirty air side:Internal structure D P
F / / GreyRAL 7038
C
External surfacessteel structureClean air housing sheetsTransition duct sheets
E P F (250) GreyRAL 7035
D Handrails, gangways,walkways, ladders / X / / / Galvanised
ESELF CLEANING AIR FILTERACCESSGratings
/ X / / / Galvanised
F SELF CLEANING AIR FILTERLocal control panel / X / / / Supplier
standard
G
COMPRESSED AIRPIPEWORKPipingBlow pipes
//
X/
//
//
//
Galvanisedsteel
Aluminium
H EVAPORATIVE COOLERInternal surfaces D PF / / GreyRAL 7035
I EVAPORATIVE COOLERExternal surfaces E P F / Grey
RAL 7035
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 23/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 2 2 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
J EVAPORATIVE COOLERACCESS / X / / / Galvanised
ITEM A041 INLET DUCT
AInternal surfaces withoutnoise insulation parts forstructural sheet
D PF / / Grey
RAL 7038 (1)
BInternal surfaces withnoise insulation parts forstructural sheet
A P1 / / Light red (1)
C External surfaces withoutnoise insulation parts forstructural sheet
E P F (120) OysterwhiteRAL 1013
DExternal surfaces withnoise insulation parts forstructural sheet
A P1 / / Light red (1)
E Internal surfaces forcladding sheet A P1 / / Light red
Galvanisedsheet must
be prepainted with
Penguardexpress§1.1.4
F External surfaces forcladding sheet E P F (50)
Oysterwhite
RAL 1013
Galvanisedsheet must
be prepainted with
Penguardexpress§1.1.4
ITEM A042 EXHAUST EXTENSION
A Structure exhaust interior S P8 / / Grey Low carbon
B Structure exhaust exterior S1 P8F9 / / Aluminium Low carbon
C Internal insulation / / / / /Stainless
steelAISI 409
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 24/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 2 3 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
ITEM A053 PIPING ARRANGEMENT, INTERCONNECTION FIELD
A Insulated pipes fluidtemperature T° < 200°C A P1 / / Light red
B Piping supports E P F 2 GreyRAL 7035
ITEM A065 TURBINE AUXILIARY PANEL
A Turbine auxiliary panel / X / / GreyRAL 7035
ITEM A098 OIL MIST ELIMINATOR SKID
A MotorFan / X / / Blue
RAL 5000
GE EnergyProductsFrance
approvedsupplier'sstandard
B
Support legs andmaintenance platformSilencerBuffer box
B PF / / Grey
RAL 7035
ITEM A108 EQUIPMENT NETWORK TOPOLOGY
A Equipment networktopology / X / / Grey
RAL 7035
ITEM A980 INLET SUPPORTING STRUCTURES
A Steel structure E P F (420) Agate greyRAL 7038
B ACCESSLadders, stairways, etc. E P F (50) Agate grey
RAL 7038
C Ladder bars S2
PFF
F10F
/ / Grey
RAL 7035
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 25/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 2 4 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
D ACCESSSteps, gratings / X / / /
Galvanisedgratingpanels
E Maintenance tools E PF / / Yellow
RAL 1023
ITEM E048 ADDITIVE INJECTION SKID
A All external surfaces E PF / / Silver grey
RAL 7001
ITEM E026 TURBINE CLEANING
A All external surfaces E PF / /
Emeraldgreen
RAL 6001
ITEM MS99 EXHAUST PLENUM MODULE
A External surfaces / X / / / Supplierstandard
ITEM 969A INTERCONNECTION PIPING, LUBE OIL
ANot insulated pipes fluidtemperature T° < 200°C E P F 19
Ocean blueRAL 5020
Stainlesssteel and
galvanisedsteel piping
are notpainted
B Piping supports E P F 2 GreyRAL 7035
ITEM 969G INTERCONNECTION PIPING, GAS FUEL
A Piping supports E P F 2 GreyRAL 7035
B piping / / / / /
Stainlesssteel piping
is not
painted2 TURBINE AUXILIARIES
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 26/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 2 5 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
222 INSULATION UNDER EXHAUST
A External surfaces E PF / (30) White
RAL 1013
240 GT UNIT FIRE FIGHTING SYSTEM
A CO2 bottles / X / / RedRAL 3000
Supplierstandard
B CO2 rack, inside container
/
Or
B
X
Or
PF
/
Or
/
/
Or
/
/
Or
RedRAL 3000
Galvanisedsteel
Or
Carbon steel
C CO2 piping / X / / /
Hot dipgalvanisedsteel is not
painted
D CO2 containerExternal surfaces E P
F / / RedRAL 3000 (1)
E CO2 containerInternal surfaces B PF / / White (1)
241 GTG FIRE FIGHTING CONTROL PANEL
A Unit fire panel / X / / GreyRAL 7035
266 GENERATOR ACOUSTIC BARRIER WALL
A Steel structure E PF / / Grey
RAL 7035
B Grating / X / / / Galvanisedsteel
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 27/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 2 6 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
C PANELS OF WALLInternal perforated sheets / X / /
GreyRAL 9002
(if applicable)
Galvanisedand
lacqueredsheets
orHot dip
galvanisedor
Stainlesssteel
DPANELS OF WALLInternal surfaces underacoustical treatment
A1 P / / Buff
SandblastedSA2.5
orZinc plated
sheet (1)
EPANELS OF WALLExternal surfaces andedges
E P F (200) GreyRAL 7035
Sandblasted SA2.5 or zinc
platedsheets (1)
F DOORS HATCHInternal perforated sheets / X / /
GreyRAL 9002
(if applicable)
Galvanisedand
lacqueredsheetsor
Hot dipgalvanised
orStainless
steel
GDOORS HATCHInternal surfaces underacoustical treatment
A1 P / / Buff
SandblastedSA2.5
orZinc plated
sheet (1)
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 28/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 2 7 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
HDOORS HATCHExternal surfaces andedges
E P F (8)Signalyellow
RAL1003
SandblastedSA2.5 or
zinc platedsheet (1)
I Miscellaneous E PF / / Grey
RAL 9002Zinc plated
sheet
270 SUMP TANK
A External surfaces E PF / / Grey
RAL 7035Internalsurface :
- Shot SA 2,5- Oiling
280 TURBINE WASHING
A All external surfaceswithout insulated parts E P
F / /Emerald
greenRAL 6001
Stainlesssteel is not
painted
B Washing tank internal andexternal surfaces / X / / / Stainless
steel
C Electrical cabinet / X / / / Supplierstandard
D ContainerExternal surfaces E P
F / /Same
colour asitem A
(1)
E ContainerInternal surfaces / X / / / Supplier
standard
2C1 LIGHT DISTILLATE OIL FORWARDING SKID
A All external surfaces E PF / / Grey
RAL 7035
2C2 HEAVY OIL FORWARDING SKID
A All external surfaces E PF / / Grey
RAL 7035
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 29/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 2 8 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
2D1 LIGHT DISTILLATE OIL FILTERING SKID
A All external surfaces E PF / / Zinc yellow
RAL 1018
2D2 HEAVY OIL FILTERING SKID
A All external surfaces E PF / / Zinc yellow
RAL 1018
2F6 WALKWAYS
A Handrails E P F A+B = (80) SulfuryellowRAL 1016
B Gangways E P F A+B = (80) Silver greyRAL 7001
C Grating / X / / /
Hot dipgalvanisedsteel is not
painted
2G0 & G025 GT GAS FUEL SUPPLY
A All external surfaces
without insulated partsE P
F/ /
Trafficwhite
RAL 9016
Stainlesssteel is not
painted
B Paint under insulated partsT° < 200°C A P1 / / Light red
Stainlesssteel is not
painted
CMaintenance platform,handrails, gratings, self closing plate, ladder, stairs
/ X / / /
Hot dipgalvanisedsteel is not
painted
2J0 GT AIR PROCESSING UNIT
AContainerExternal surfaces E
PF / /
Window
greyRAL 7040 (1)
B ContainerInternal surfaces B P
F / / RAL 9003 (1)
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 30/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 2 9 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
C Compressor unit D PF / / RAL 5019
D Air tank capacity / X / / /Galvanisedsteel is not
painted
E Air coolerExternal surfaces D P
F / / RAL 5019
F Air dryer D PF / / RAL 5019
G Piping / X / / /
Galvanised
steel andstainlesssteel are not
painted
4 EXHAUST SYSTEM
422 LATERAL EXHAUST
A Internal surfaces S P8 / / Grey
Perforatedsheets of
the silencerare in
stainlesssteel
(1) / (2)
B External surfaces withoutcladding and insulation S1 P8
F9 / / Aluminium
C Structure support for duct E P F (80) Agate greyRAL 7038
425 ELBOW AND DOWNSTREAM DUCTING
A Internal surfaces S P8 / / Grey
Perforatedsheets of
the silencerare in
stainlesssteel(1) / (2)
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 31/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 3 0 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
B External surfaces withoutcladding and insulation S1 P8
F9 / / Aluminium
C Frame and structuresupport E P F (50) Agate grey
RAL 7038 (1)
432 EXHAUST STACK ON SIDE EXHAUST
A Internal shield / X / / /
Internalferritic
stainlesssteel
BExternal shield (shaft&base or upper beam of upper steel structure)Internal surface (corten)
S P8 / / Grey (1)
C
External shield (shaft&base or upper beam of upper steel structure)External surface (corten)
S3 P8F9 F9 / Aluminium
D Liner belts (corten) S P8 / / Aluminium (1)
E Transition stiffeners(corten) S1 P8
F9 / / Aluminium (1)
F Access and gangways E P F (400) Agate greyRAL 7038
(1)grating HOTDIP GALVAprotectionpanels fully
HOT DIPGALVA
G
Structure support andupper steel structure of chimney E P F (500) Agate grey
RAL 7038
(1)
H Transition protection (if applicable) E P F (80) Agate grey
RAL 7038 (1)
I Stack upper frameworkitems 7&8 (Corten Beams) S1 P8
(F9) (F9) / Aluminium (1)
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 32/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 3 1 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
460 SCREEN AT GT EXHAUST FOR PERSONNEL PROTECTION
A Wire netting / X / / / Supplierstandard
B Structure support E P F (50) Agate greyRAL 7038
5 GENERATOR & ENERGY EVACUATION
510 GT GENERATOR
A All internal surfaces / X / / /Supplierstandard
B All external surfaces / X F (180) Azure blueRAL 5009
Supplierstandard
530 GT UNIT CIRCUIT BREAKER
A All surfaces / X / / GreyRAL 7032
B Roofs / X / / WhiteRAL 9016
543 GENERATOR ACCESSORY COMPARTMENT
A Internal surfaces / X / / /Supplierstandard
External surfaces (GLAC & GNAC) E P F (70) Grey
RAL 7035Carbon
SteelB
Or / X / / /
Aluminium5754 orStainlessSteel 316
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 33/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 3 2 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
Or B P F (70) GreyRAL 7035
OtherAluminiumor StainlessSteel quality(add 50 µm
of PenguardExpressbefore
applyingsystem B)
External surfaces (GLAC & GNAC Bus Duct) E P F (50) Grey
RAL 7035Carbon
Steel
Or / X / / /
Aluminium5754 orStainlessSteel 316
C
Or B P F (50) GreyRAL 7035
Other
Aluminiumor StainlessSteel quality(add 50 µm
of PenguardExpressbefore
applyingsystem B)
DSupporting structure / X / / / Galvanised
steel (100
µm mini)560 MV BUS DUCTS
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 34/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 3 3 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
A External surfaces / X / / GreyRAL 7032
B Supporting structure / X / / / Galvanisedsteel
8 COOLING SYSTEM
811 SIMPLE CYCLE FIN FAN COOLERS
A Internal surfaces of :
Silencers, fans and plenumE P
F/ /
Light greyRAL 7035
or same asexternalsurfaces
(1)
B
External surfaces of :Silencers, fans, plenum,water-box and steelstructure
E P F (200)Oysterwhite
RAL 1013
C Fin fan piping E P F (20) Ocean blueRAL 5020
D Expansion tankinternal surfaces H P4
F4 / / Grey
EExpansion tankexternal surface
steel structure
E P F (10) Light blueRAL 5012
F Pumping skidframe E P F (10) Light blue
RAL 5012
GPumping skidpumpmotor
/ X / / / Supplierstandard
H Pumping skidother external surfaces E P F (10) Light blue
RAL 5012
9 PIPING SYSTEM
910 PIPING
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 35/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 3 4 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
A Insulated pipes fluidtemperature T°< 200°C A P1 / / Light red
Stainlesssteel and
galvanisedsteel piping
are notpainted (canbe painted,in case of contract
order)
B Insulated pipes fluidtemperature T° > 200°C A' P8 / / Grey
Stainlesssteel and
galvanisedsteel piping
are notpainted (canbe painted,in case of contract
order)
C Not insulated pipes E P F (200) Ocean blueRAL 5020
Stainlesssteel and
galvanised
steel pipingare notpainted (canbe painted,in case of contract
order)
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 36/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 3 5 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
D
Piping supports
Or
“LISEGA” materials
E
/
/
P
X
X
F
/
/
(50
/
/
WhitealuminiumRAL 9006
/
/
Galvanisedsteel piping
are notpainted (canbe painted,in case of contract
order)
please referto §1.1.6.
E Underground pipes (except piping in trenches) (1) X / / /
GE EnergyProductsFrance
approvedSupplierstandard
* Coldwrapping
tape
consistingof acombinated
anti-corrosive
mastic andpressuresensitiveadhesivelaminatedto a robustand flexible
plastic
backingB GT CONTROL & LV DISTRIBUTION
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 37/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
(5) It will be possible to apply RAL 7035 instead of RAL 9002.All items must have same colors RAL 9002 or RAL7035.
Reference : 394A1633 Rev. : B Section : 01 Page : 3 6 / 3 7Ce document, propriété exclusive de GE Energy Products France SNC est
strictement confidentiel. Il ne peut être communiqué,copié ou reproduit sans notre autorisation écrite.
This document, exclusive property of GE Energy Products France SNCis strictly confidential. It must not be communicated,
copied or reproduced without our prior written consent.
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
B10 PACKAGED ELECTRONIC & ELECTRICAL CONTROL CABINET (PEECC)
A Package internal surfaces / X / / / Supplierstandard
B
Battery compartment floor
or
2 coats of 150 µm of tankguard
storage
/
P1F1
X
/
/
/
/
Light grey
/
stainlesssteel ar notis painted
C Package external surfaces E P F (240) GreyRAL 7035
B51 GT & GENERATOR AUXILIARIES LV DISTRIBUTION (MCC)
A Gt & generator auxiliarieslv distribution (mcc) / X / / Grey
RAL 7035
B52 125 V DC BATTERY CHARGER CUBICLE
A 125 v dc battery chargercubicle / X / / Grey
RAL 7035
B53 125 V DC BATTERY
8/11/2019 E0878CF0---ES001.PDF
http://slidepdf.com/reader/full/e0878cf0-es001pdf 38/38
GENERAL PAINTING SPECIFICATION
E0878 – MEGA DEAL D
(1) GE Energy Products France SNC Standard
(2) The duct casing will be internally painted (after grid-blasting) on. All carbon steel areas which are not internallycovered by insulation (for example, silencer duct areas where baffles are put on) and a width of 100 mm at the inletand the outlet borders of the duct casing
(3) All elements of structure with penetration through walls or roofs shall be painted with final coat
(4) Apply system required for non roofed compartment when equipment is adjacent to a roofed compartment anda non roofed compartment
ITEM EQUIPMENT SYSTEM
TYPESHOP SITE
ESTIMATEDSURFACE
FOR FINALCOAT IN M²
FINAL
COLOURREMARKS
A 125 v dc battery (standbattery) / X / / Grey
RAL 7032
ELECTRICAL MOTORS PUMPS FANS VALVES & IN LINE INSTALLED EQUIPMENTS AND DEVICES
A
Electrical motors pumpsfans valves & in lineinstalled equipments anddevices
/ X / / / Supplierstandard
MANUTENTION & MAINTENANCE TOOLS
AManutention & maintenance tools E
PF / /
YellowRAL 1028