Dynamic Vibration AbsorberDistributing energy in line with the First Law of Thermodynamics
James SylvesterParsons Peebles Service
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
History & Background
High lift pumps at the pumping station facility have historically suffered from low reliability and required many expensive overhauls with new bearing sets (Babbitt/White Metal)
Various attempts to resolve the root cause have not been successful
Slide 1
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Bearing Inspection
Slide 2
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Bearing Location
Tilting pad bearing location
Bed Plate – view from underneath
Slide 3
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Bearing Inspection: Oil
Microscopic inspection of the oil, debris is present
Slide 4
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Bearing Inspection: Tilting Pad
The pads vary from no contact to full contact and cracking of the tilting pad, indicating eccentric (non‐orbital) motion
Slide 5
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Bearing Inspection: Tilting Pad
Microscopic image of a pad with no wiping, and an image of a pad with wiping damage
Slide 6
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Bearing Inspection: Tilting Pad
Microscopic image of the cracked pad surface displaying fatigue cracking
Slide 7
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Bearing Inspection: Tilting Pad
Microscopic cross sectional image of the cracked pad
Bond line intact
Failure is at the weakest point, the pivot point
Slide 8
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Vibration Inspection
Slide 9
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Velocity Spectra
Forcing function 1 Order Directional vibration Vibration changes with speed
Dial Number
RPM 1Order Overall
0 662.51 30.25 35
1 679.34 26.94 28.96
2 694.75 20.98 21.22
3 707.68 15.87 18.00
4 721.29 12.77 15.02
5 740.79 11.63 13.69
Horizontal
Vertical
Slide 10
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Adding Mass to the system The addition of weight moved
the resonant frequency down to speed range 2
The weight (additional mass 10Kg) dampened the vibration motion and lowered the resonant frequencies
Conformation of a resonant condition
Slide 11
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Overall Vibration vs Speed: Mass added
• The peak vibration is now occurring at speed set point 2
• As the speed increases the vibration reduces
• This type of vibration and speed relationship indicates a resonant issue
Slide 12
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Vibration vs Speed: Strip Chart
Speed 3 high fluctuation, indicating a critical speed / resonance / beat frequency
Speed 5 lower levels and more constant
Slide 13
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Orbit Data
Raw Data 1 Order Filtered
Slide 14
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Resonance Test ‘Bump Test’
Bump test indicating a structural resonance
Bed Plate
537.58 CPM
650.50 CPM
375 CPM to 860 CPM
Slide 15
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Floor Structure
Bed Plate
False Floor
False Floor
Bed Plate – view from underneath
Slide 16
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Workshop: Amplitude and Phase
One order tracked
Set up on a test bed no load
Accelerometer location on the top of the motor (NDE)
Slide 17
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
On‐Site: Amplitude and Phase
One Order tracked
Set up on foundation under normal operational load
Note how the structure changes the motion
Resonance
Running speed range on site
Slide 18
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Why?
Slide 19
Motor bearing failures, concentrated at the motor drive end
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
The ‘Five Whys’
The motor Babbitt (white metal) tilting pad bearings fail
There is metal to metal contact
Overload fatigue ‐ Increased dynamic load on the bearing
High directional vibration causing the coupling and prop shaft to overload the bearing
On site structural resonance amplifying the motion of the motor. This creates highly stressed/torsional load at the drive end of the motor
Slide 20
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Conclusion
There are no issues with the motor rebuild, the balanceand dynamics of the motor when operated unloaded inthe test bay, >4mm/s RMS
A structural resonance on site is causing an amplificationof vibration levels
This resonance increases the dynamic loads on the driveend bearing
This then causes Babbitt fatigue, cracking, and Babbittwiping due to rotor to stator contact
Slide 21
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Visualising the issue
Slide 22
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Side by Side
Standard Video Amplified Video
Higher movement this direction
Horizontal Measuring plane
Slide 23
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Bed Plate
False Floor
Motor mounting frame
Floor in resonance
Bed Plate
Slide 24
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Motor mount
False Floor
Standard Video
Motor mounting frame
Bed Plate
Amplified Video
Slide 25
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Support Steel Work: Modification
A decision to stiffen the structure was made All good in theory but where does the energy go?
2.5m
0.38m
Slide 26
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Support Steel Work: Vibration Results
Stiffening the structure increased the vibration levels to 35mm/s RMS
Usual operating range around 10 mm/s RMS – 14 mm/s RMS
Additional steel work 35mm/s RMS
Still high directional motion
Slide 27
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Dynamic Vibration Absorber
Slide 28
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
What is a DVA?
It is a tuned spring mass system which reduces or eliminatesthe vibration of a harmonically excited system
All rotating machines can induce vibration due to structuralresonances. A dynamic absorber can be tuned to excite insuch a way exactly counteracts the force from the structuralresonance
Properly implemented, a dynamic absorber will neutralise theundesirable vibration, which would otherwise reduce servicelife or cause mechanical damage
Dynamic absorbers differ from tuned mass dampers in thatdynamic absorbers do not require any damping to functionsatisfactorily
Slide 29
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
DVA Design: Dunkerly Method
“a”L
D
hw
LumpedMass M2
Bar propertiesrho, E
Motion
• Bar Cross Section• Length • Free Distance to weight• Bar diameter • Bar width • Bar height • Density • Young's Modulus• Target resonant frequency
Slide 30
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
DVA Site Installation
Safety tethers
Slide 31
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
DVA Site Installation: Video Normal Speed
Slide 32
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
DVA Site Installation: Video
Slow Speed showing thepoint of flex
Slide 33
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Vibration Results: Overall Levels
Structural modifications 35mm/s RMS
Normal operating range After fitment of DVA 6.5mm/s RMS
Slide 34
Location
Radial
(Deg
.)
Normal
Ope
ratio
nal
Structural
Mod
s
DVA
NDE (TOP)0 10.86 35 5.41
90 8.21 18.17 5.82
DE (BOTTOM)
0 2.41 9.55 1.27
90 2.11 5.92 1.57
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Vibration Results: Overall With Speed
Slide 35
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Table of Directional Ratio Vibration Data
This table is the difference in the radial vibration velocity in mm/s RMS (Lower the number the less stress to the bearings)
LocationNormal Operational
Structural Modifications
Vibration Dynamic Absorber
NDE (TOP) 2.65 16.83 0.41
DE (BOTTOM) 0.30 3.63 0.30
Slide 36
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
12 Month Inspection
Slide 37
Follow Up
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
12 Month Follow up on Trial
The fatigue rate for the main arms of the Dynamic Vibration Absorbers are 11/12 months
Slide 38
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Installation of replacement DVA Arms One order
vibration reduced from 13.7 to 4.5 mm/s RMS after the DVA Arms were replaced
Slide 39
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
DVA: Summary
The Dynamic Vibration Absorbers have been successful inabsorbing the vibration energy from this asset ensuringlow vibration levels and correct dynamic motion
This will enable the asset to run longer in operationbefore maintenance/repair increasing the functionabilityof the pump and reducing the overall operational lifecosts of the asset
The average costs to change the motor bearings is£15,000, if the motor failed the average cost for a fulloverhaul and rotor rewind is £55,000. This excludes thecosts of loss of production and associated financial andreputation costs.
Slide 40
THE WORLD’S CONDITION MONITORING CONFERENCE | MANCHESTER, UK 2019
Thank you ‐ CM Pearls of Wisdom The most important part of any program is the person performing the data collection and
analysis. The second most important part of any program is the training given to the person
selected. 5 years of experience is not the same as 1 year of experience 5 times. The most important question you can ever ask is “why”. It is important to understand the values of the numbers you are using. Physics of the machine is really important. You can’t analyse what you don’t know or understand. A person may not be stupid, they may just not understand what you are saying. 1 times RPM is not always imbalance. There are no universal vibration severity limits. Absolute amplitude in the frequency domain is relatively useless. Don’t forget the time
domain & phase. There are no ghost frequencies or unknown frequencies but only frequencies not enough
analysed. What was the last maintenance, modification or process change performed on the asset. Don’t ignore the potential benefits of chit chat in the crib/break room with the operators
and maintenance teams. They know their machines! When all else fails, leave the air conditioning, and go examine the operating equipment.
Go look, touch, feel, smell and listen to the machinery
https://theseasonedanalyst.guru/