dynamic flow computers product presentation. main office houston, texas branch office calgary,...
TRANSCRIPT
Dynamic Flow Computers
Product Presentation
MAIN OFFICEHOUSTON, TEXAS
BRANCH OFFICECALGARY, CANADA
BRANCH OFFICEUNITED ARAB EMIRATES
MIDDLE EAST & ASIA
BRANCH OFFICEMEXICO D.F., MEXICO
MEXICO & SOUTH AMERICA
OFFICE & SERVICE CENTERSAUDI ARABIA
Dynamic Offices
Company History
• 1986-1992 Founders at Elliott Flow Computers
• Dynamic Flow Computers Established in 1993
• 1993-1997 Focused on Liquid Markets
• 2000 - Micro MV
• 2001 - E Chart
• 2003 - E Chart Plus
• 2005 - E Chart Lite
• 1998-Present Focus on both Liquid & Gas markets
Mission Statement
“The objective of DFC is to provide you with the latest in
state of the art Electronic Flow Measurement with a
total commitment to quality in products and service”.
Over the years we have strived to bring the latest advances in technology to the flow computer industry
Some examples:
• Wireless Bluetooth™ Communications.
• Memory Stick Walk-by SCADA.
• Fieldbus Foundation Protocol.
• Graphical Trend Screens.
• First field-mounted liquid flow computer.
Latest Technology
API 14.3 OR AGA 3 – (Differential orifice, Cone, etc)
AGA 7 (Frequency such as Turbine, PD, and Others)
AGA 8 Compressibility (Gross & Detail Methods)
API 21.1 & 21.2 EFM Standards
API Liquid Algorithms
Other Specific Applications Available
Flow Measurement Standards
• Temperature rating -40 to +185 °F• PID & Boolean Logic• Math Functions• Low Power (Only 0.5 Watts)• 35 to 55 days of data Storage
• 4 Line by 20 Character Display
• User configurable scrolling display with ‘display freeze’ option
• Infra red sensors for easy configuration & calibration
• Gas or Liquid
• Class 1, Division 1
• Up to Four Meter Runs
• Touch Screen with A Level Security
• Built in UPS for days of operation
• Built in Rosemount 205 for Pressure, Temperature, & DP
MicroMV
Gas and Liquid
Class 1, Division 1
2 Digital Outputs
1 Digital/Frequency Input
2 Analog Inputs
One RS232 and One RS 232/485
16 Bit Analog Output
Graphical Display
Built in Rosemount Multivariable 205
Temperature rating -40 to +185 °F
PID, Boolean Logic, & Math function
Meets API 21.1 for Custody Transfer
64 days of Data Storage
Low Power Solar Options
Battery & Enclosure temperature built-in
DISPLAY 8 Lines of Text
Graphical Trend Display User Configurable Display
Min / Max Trending
• The Most Accurate and Reliable on the Market.
• Exclusive Dynamic-Rosemount agreement.
• Accuracy is +0.1% standard or +0.075% optional.
• Measures static, differential pressure, and temperature• Rosemount co-planar flange for easy installation.
• High stability design means less calibration.
• SPECIFICATIONS• Pressure Ranges: 0-800 PSIG or 0-3626 PSIG • DP Ranges: 0-25, 0-250 or 0-1000 Bi-Directional Inches of
Water• RTD plugs in to the 205 module directly with a Temp range up to
1200 F• Update time of 108 mS
Rosemount Multivariable
Typical Field Installation
Typical Field Installation
HAZARDOUSAREA
GENERALPURPOSEAREA
FLOW COMPUTERS CAN BE DIRECT MOUNTED OR MOUNTED ON A 2“ POLE
Additional MV/EChart w/Transmitters and with or without Display
Multiple Run Installation
Our standard communication ports let us integrate with all the current communication media.
And now we also support the latest Bluetooth Wireless protocol
Built-in Communications
• On Site ECHART to Micro MV in 10 Minutes
• 1 Meter run up to four meter runs using MV &
EChart or 3095 Multi-variable Transmitters
• Well Optimization
• PID & Logic Control
Inputs / Outputs
• Nine 24-Bit analog channels per MV with 3 additional MV slave units for I/O expansion
(21 analog)
• 3 frequency channels with three additional MV slave units for I/O expansion
(12 channels)
• 4 analog outputs with 3 additional MV slave units expansion
(7 analog out)
• 3 digital inputs or outputs with three additional MV expansion
(9 digitals)
• 3 Communication ports
• Up to 4 meter runs in one MV device. Mixture of liquid and gas algorithms corrected to 15°C or 60°F (metric or US units)
• Slave I/O module when only 1 meter run
MicroMV Field IO & Expansion
• Windows & DOS Configuration
Software
• On site Configuration
• Remote Configuration
• Modbus Master & Slave (ASCII or
RTU)
• Data Storage & Retrieval
• Data Displayed & Collected via
PDA, Laptop, Radio, Cell, or
Satellite
• Low Power
Data Management
Each history point is configured to archive the current value, average value, totalized value, and accumulated value.
35-64 days of data storage that includes calculated values including Min./Max. values, minute, hourly, hourly, and daily values
One Year of Monthly Data is also Stored
Historical Data
• The Event Log records the last
200 parameter changes
• The Alarm Log records the last
200 occurrences of alarms
• The logs can be viewed, saved,
printed, or transmitted
• Alarms & Logs for the four
Meter Runs are stored when
using the four meter run option
Event & Alarm Logs
• Report By Exception
• Allows Cry out
• Allows the Flow Computer to
report any Alarms to the Host
system
Report by Exception
• All Final Assembly & Testing is done in Houston, Texas.
• CPU Boards are made in Canada, Housing by Adalet, and Transmitters by Rosemount USA.
• Units are tested in an environmental chamber for 72 hours and bench tested for a 2 week period prior to shipping.
Manufacturing Facility
• Dynamic worldwide offices & agents/representatives
are key sales support
• Dynamic Flow Computers are standard units,
available in stock at all times, and ready for
shipment within hours, days, or weeks depending on
quantities and customer request.
• Dynamic has a training program that can be given at
our facility or on site.
Sales & Support
• Dynamic Flow Computers are easy to use and easy
to maintain.
• In Canada Service support is performed by Tundra
Controls, Syntech Enerflex, Bentek Systems, Pro-
Logic Controls, or by Dynamic technicians upon
request.
• Service requests are dealt with immediately by
Tundra and Syntech through their various 24 / 7
support centers.
• Dynamic Mfg./Service facility in Calgary, AB
Service
Future Products
• 10 Times more processing power.
• Built-in Ethernet and USB: Even more communications alternatives.
• The REAL Smart I/O: Interchangeable I/O Modules provide a wide range of Input / Output configuration options.
• Advanced Diagnostics including our renowned Turbine Diagnostic.
• Redundancy and Smart I/O capabilities: Multiple SuperMVs in a single network can act as separate units, extended smart I/O, or 100% redundant systems.
• Modbus™ & Foundation Fieldbus™ compatible communication
• Multiple API, AGA, and ISO equations are programmed into each unit.
• Dynacom™ software with user friendly interface for PCs and Handhelds
Upstream
Separator
Injection
Measures Key production metrics
Oil
Steam
CO2
Gas
Water
Water
Test Separator Report
Typical Upstream Installation
Flow Meter
FlowComputer
SolarPanel
Comm.Package
Midstream
Pipeline Metering
Meter Proving
Tank Levels
Custody Transfer
Sends data back via SCADA to control rooms
Measures Pipeline Operation
Prover Report
Batch Report
Typical Midstream Installation
Flow computer
Sampler
Tank Levels
Flow computer
Downstream
Refinery
Inputs (Oil, Gas)
Outputs (Refined Prod.)
Steam
Energy (BTUs)
Helps Measure Plant Efficiency (Outputs- Inputs)
Bi-directionalVolumeReport
Bi-Directional Report
Typical Downstream Installation
Multiple Meter Runs
FlowComputers
Data goesTo ControlRoom Additional
Equipment:- Densitometers- Chromatograph
s- Etc.
Installation Pictures
Installation Pictures
Installation Pictures
Installation Pictures
Installation Pictures
Installation Pictures
Installation Pictures
Installations
SONATRACH
Algeria
SAUDI ARAMCO
Saudi Arabia
KUWAIT OIL COMPANY
Kuwait
TEXACO PIPELINE
USA
MOTIVA
USA
Husky Energy
Canada
PEMEX
Mexico
ZETA GAS LPG
Peru
ATLANTIC LNG
Trinidad
AL FANAR PETROLEUM
Egypt
Chevron/Enerpro
Canada
Petro-Canada
Canada
CONOCO-PHILLIPS
USA
Shell
USA
Apache
Canada
BP-AMOCO
USA
CHEVRON-TEXACO
USA
EXXON-MOBIL
USA
Select Dynamic Users