ducted range · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\...

21
DUCTED RANGE H E A T I N G / A I R C O N D I T I O N I N G S O L U T I O N S COME HOME TO FUJITSU COMFORT 6 YEAR PARTS & LABOUR WARRANTY WHEN YOU USE A FUJITSU ACCREDITED INSTALLER

Upload: others

Post on 16-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

D U C T E D

R A N G EH E A T I N G /

A I R C O N D I T I O N I N G

S O L U T I O N S

C O M E H O M E T O F U J I T S U C O M F O R T

6 Y E A R P A R T S & L A B O U R W A R R A N T Y

W H E N Y O U U S E A F U J I T S U A C C R E D I T E D I N S T A L L E R

Page 2: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

3

W H Y C H O O S E F U J I T S U ?

N E W Z E A L A N D ’ S F A V O U R I T E A I R ®

Fujitsu General is a leading supplier of Heat Pump/Air Conditioners in New Zealand with a portfolio to suit both residential and commercial applications.

We focus all of our research and manufacturing strengths into Heat Pump/Air Conditioners which has resulted in the extensive range of world-class, energy efficient, market-leading systems.

Fujitsu General strives to consistently provide high quality, reliable products accompanied by superior customer service. To be ‘New Zealand’s Favourite Air ®, means to be the best heating/air conditioning company to deal with in New Zealand, not just a leading heating/air conditioning brand.

That’s why we’re proud to say we are ‘New Zealand’s Favourite Air ®’.

P E A C E O F M I N DFujitsu’s accreditation programme for installers helps ensure that you’ll get the right fit for your unique space. A professional installation is essential for the efficient performance of any Heat Pump. Ask to see their red card!

N E W Z E A L A N D S L O N G E S T M A N U F A C T U R E R ’ S W A R R A N T YFujitsu believe in the quality and reliability of every Heat Pump/Air Conditioner we sell. When you use a Fujitsu accredited installer, you’ll get a full 6-year parts and labour warranty - for the reassurance you need that we stand behind our product for the long term.

ACCREDITEDINSTALLER

2

S T A T E O F T H E A R T R E S E A R C H A N D D E V E L O P M E N T Our state of the art research and development centre, located at our headquarters in Japan, is equipped with numerous testing facilities simulating a variety of heating and cooling operating conditions.

PERFORMANCE TESTING UNDERTAKEN INCLUDES:

• Evaluating the units heating and cooling capacity under varied temperature and humidity conditions

• Testing the units air volume and air flow distance

• Measuring the units operating noise

• Evaluating the units durability to withstand outdoor weather extremes.

This rigorous testing is aimed at meeting Fujitsu’s high standard of product quality and reliability.

Page 3: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

A I R F I L T E R S Fujitsu’s advanced filter systems contribute to a fresher and cleaner living environment. Fujitsu’s Catechin filters are approved by the Asthma and Respiratory Foundation NZ’s Sensitive Choice® Programme.

C O B A L T B L U E P R O T E C T I O NThe Fujitsu outside unit heat exchanger fins are specially coated with Cobalt Blue - to help protect against corrosion and enhance the durability as well as extend the performance life of your Fujitsu Heat Pump/Air Conditioner.

D C I N V E R T E R T E C H N O L O G YHigh energy efficiencies are achieved with Fujitsu’s twin rotary DC compressor, DC inverter control and DC fan motor technology.

H I G H E F F I C I E N C Y H E A T E X C H A N G E RHigh density multi-path heat exchanger. Heat exchange performance is substantially improved by thin and high density heat exchanger and multi-path efficiency technology.

J U S T Q U I E T L YUsing the latest fan technology plus ‘quiet mode’ means Fujitsu Heat Pumps/ Air Conditioners are very quiet. Compare our decibel noise levels on the chart adjacent.

P E R F O R M A N C E G U A R A N T E EWe are so confident that you will be delighted with the effectiveness of your new Fujitsu Heat Pump/Air Conditioner that the Heat Pump Installer can offer you a written Performance Guarantee. This is your assurance that the new Heat Pump/Air Conditioner specified for your home will deliver on its promised performance for heating, even when it’s freezing outside.

H O W D O Y O U G E T T H E P E R F O R M A N C E G U A R A N T E E ?Fujitsu Heat Pump dealers displaying the ‘COMFORT SELECTOR’ logo on the ‘where to buy’ page at www.fujitsugeneral.co.nz are equipped to offer the Performance Guarantee.

T H E C O M F O R T S E L E C T O R The comfort selector is a specialist sizing tool that is really helpful when choosing your Heat Pump. It will:

1. Assess everything about your home, including its location in New Zealand and your individual heating needs.

2. Select the perfect model for you.

3. Provide you with:• Performance Guarantee• Quotation• Heat Pump running costs (it will even show you the savings you can make)• Heat Pump features and benefits

So now you can be sure that your choice will be the best possible Heat Pump for you.

T H E R E P O R T I N C L U D E S :• All about your home• The perfect Heat Pump for your home• Running costs (and savings) - Heat Pump features and benefits• Efficient running tips • Heat Performance Guarantee• Quotation

Quotation

Prices

Equipment Price Including GST (See comments below)

Total $Comments

Our Contact Details

From:Mobile: Address:Mike Rogers0221665453

Company

PhoneAnother Company 0134232212

Quantity Required - 1ABTF18LAT Indoor with AOTA18LALL Outdoor Unit

Your New Heat Pump Running Cost

COST RESULTS

HEAT PUMP (Per System) DIRECT ELECTRIC HEATER

(based on $0.20 per kW/hr)

HEAT OUTPUT OF : 3.6kW

EQUIVALENT ELECTRIC HEATING

$0.16 per hour$1.28 per day (8 hours)$39.68 per month (31 days)$238.08 per 6 Months (Heating Season)

$0.58 per hour$4.64 per day (8 hours)$143.84 per month (31 days)$863.04 per 6 Months (Heating Season)

HEAT OUTPUT OF : 3.6kW

To heat the room calculated in this report using traditional type electric heaters would cost approximately $0.58 per hour compared to the heat pump that would cost approximately $0.16.The use of a heat pump compared to standard electric heaters of the same output will cost significantly less to operate. In fact in this example, over the typical 6 monthheating season your savings could be as much as $625Plus with a heat pump system you have the benefit of cooling operation during thesummer when the high temperatures and high humidity can cause discomfort.The above calculations should be used as a guide, based on the expected averageoperating cost for the selected heat pump. It assumes the system has been installed correctly and is operating efficiently. Plus the heat pump is operated andmaintained in accordance with the manufacturers guidlines.(see notes previously on how to run your new heat pump efficiently).

Explanation

POWER INPUT 3600 WPOWER INPUT : 810 W

REFER TO HEAT PUMP SELECTED

General Heat Pump Information

Heating ExplainedHeating a room is all about replacing heat that is being lost to the surrounding area. Heat energy always travels in the direction hot to cold.

If your room is perfectly insulated then heating would not be required as there would beno loss of heat. If people enter this perfectly insulated box it would rise to the temperature of the occupants, as heat is being given off by the occupants entering the room.

The output capacity of a heat pump is therefore calculated to overcome the heat losses to other areas like outside or adjacent rooms. For greater energy saving, reduce the amount of heat loss as much as is practical by closing curtains, doors, windows etc.

Adding or improving your room insulation will further improve energy saving.

The calculation of the correctly sized heat pump is not a rule of thumb calculation because it is important to size the unit so that it will operate at its most efficient point for as long as possible.

The program used to generate this report has been designed specifically for the New Zealand market and takes into account factors that are relevant for your area of New Zealand.

General Use - HeatingThis heat pump selection has been calculated to heat the room or rooms detailed - based on information displayed in this report.

Adjacent doors to unheated areas should be closed. These areas are not included.

Leaving doors open to un-heated areas can cause the heat pump to work for longer than it has been designed to operate and would affect the unit’s efficiency and possibly increase the periods of defrost operation.

Operation AdviceHeat pumps should been seen as a very efficient fan heater. An electric fan heater of any size installed into one room could not be expected to heat connecting rooms very effectively-this is the same for a heat pump.Heat pumps are incredibly efficient when used correctly. It is possible to achieve over a 4:1 heating ratio. For every 1kW of electric power consumed your heat pump can deliver over 4kW of heat output.

This selection is based on operating the heat pump at comfort control temperatures. The control temperature setting should be set to a typical temperature like 21 deg which is a comfortable temperature for people. Setting the control temperature higher will only cause the unit to work unnecessarily hard, which can therefore reduce the heat pump’s efficiency.

Operating the unit at a fixed reduced fan speed will limit the capacity the unit can provide. Operating the unit in Auto-Fan will maximise the capacity of the unit.

Filters should be kept clean.

Outdoor units should be positioned clear of obstructions such as overgrown shrubs, fences etc.

Heat Pump Selected

IMPORTANT: Performance Selection Notes

Heating - Each System Provides: Cooling - Each System Provides:

Heat Output @ +7°C Cool Output @ +35°C Out / + 27°C

6kW Heating 5.2kW Heating

The performance figures above will change as outdoor and indoor temperatures change. This selection

hasbeen designed to take that into account and select the correclty sized unit for comfort level control.

Operational Guidance

Please follow operational guidance in the product user manual to ensure you achieve the best possible

experience from your new heat pump.

Heat Pumps are generally only designed to heat one room (the room they are installed into). Ducted type

systems may offer a more central type system or multi-split which can heat / cool more than one room at a

time.

All windows and connecting doors should be kept closed both for heating and cooling operation. Fan

speed settings should be switched to Auto Fan. Operating your heat pump at fixed low or quiet fan speed

for extended periods of time,will affect its ability to deliver the required heating capacity for the space.

Electric Heat Pumps of the type selected here are one of the most energy efficient ways to heat your home

or office.

Our Contact Details

From: Mobile: Address:

Mike Rogers 0221665453

Company Phone

Another Company 0134232212

Quantity Required - 1

ABTF18LAT Indoor with AOTA18LALL Outdoor Unit

Project Details

Project Ref:Location:

Date:

ExampleCanterbury

28/04/2011

Room Description:Room Dimensions (Metres)

LoungeLength: 5

Width: 4Height: 2.9

Specifications

Minimum Outdoor Temperature HEATINGRoom Design Temperature

-4.5 Deg C

21 Deg C

Maximum Outdoor Temperature COOLINGRoom Design Temperature

32 Deg C

21 Deg C

Surface Direction Internal/External DescriptionU

Value

R

Value

Gain-

kW

Loss-

kW

Wall 1 North External Insulated Cavity Walls 0.49 0.078 0.185

Wall 2 South Internal Insulated Cavity Walls 0.49 0.078 0.185

Wall 3 East External Insulated Cavity Walls 1.60 0.000 0.000

Wall 4 West External Hollow Cavity Walls 1.60 0.000 0.000

CeilingRoof 75mm Insulation

0.45 0.099 0.234

FloorUn-Heated Room Below

0.76 0.653 1.544

Windows Sq (M)Description

U Value Cool kW Heat kW

North: 8.00Single Glazing

5.6 1.9 1.615

South:

0.0 0.000

West:

0.0 0.000

East: 2.00Single Glazing

5.6 0.4 0.291

Roof: 0.0

0.0 0.000

Additional Summary

Cooling calculation based on settings for Domestic Cooling

People Gain W @ 20C:Electrical Gain W:

About Your Home And The Area To Be Heated

Heating kW: Total Cooling kW:

5.05.7

Heating and Cooling capacity calculated to heat and cool your room efficiently.

FREE REPORT!

PERFORMANCEGUARANTEE

Fujitsu can guarantee you will get all the heating & cooling

you’ll need.

CCOMFORT SELECTOR

W H Y C H O O S E F U J I T S U ?

54

Page 4: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

D U C T E D R A N G E

W H A T I S D U C T E D H E A T I N G / A I R C O N D I T I O N I N G A N D H O W D O E S I T W O R K ?Ducted heating/air conditioning is a solution that allows you to condition multiple rooms or the entire house using just one system.

The indoor unit is usually located in the ceiling or under the floor so it doesn’t infringe on the aesthetics of your home.

Conditioned air is circulated via a network of ducts in your ceiling or floor cavity, with outlets in as many or as few rooms as you wish.

The temperature and hours of operation are controlled by a simple and easy to use control panel.

All Fujitsu ducted heating/air conditioners are reverse cycle, meaning they can keep you warm in winter and cool in summer.

D U C T E D R A N G E

W H A T I S Z O N E C O N T R O L ? ***

Ducted heating/air conditioning with zone control capabilities allows for different zones (areas) to be set up in your office or home for optimal comfort and energy management. The system adjusts airflow through dampers at set time periods to control the heating or cooling of the selected zones.

E N E R G Y E F F I C I E N C YBy using the weekly timer function the operation can be set up to match your daily schedule. It’s a ‘set and forget’ way to keep the temperature of your home comfortable all year round.

U S E R - F R I E N D L Y F U N C T I O N SThe user-friendly control features a large display for ‘Mode’, ‘Set Temp’ and ‘Fan’ with each function represented by an intuitive icon.

Remote Temperature Sensor

Indoor unit

Zone Control Interface

Wired Remote Controller

Damper (field supply) TOUCH SCREEN CONTROLLER**

FEATURES:• Touch screen

LCD panel

• Built in weekly/ daily timer and auto off timer

• Backlight

• Room temperature display

BACKLIT CONTROLLER*

FEATURES:• Zone names

can be programmed

• Weekly timer

• Simple operation

• Room temperature displayed on home screen

• Child lock

# Accessory for ARTG09/12LLLB | ARTG18LLTA | ARTG24LMLC | ARTA30LBTU | ARTA36/45LATU

* Optional extra for ARTG09/12LLLB | ARTG18LLTA | ARTG24LMLC | ARTA30LBTU | ARTA36/45LATU

** Optional extra for ARTG_LHTDP | ARTG_LDTA

*** Optional extra for: ARTG_LHTDP/LDTA/LHTA/LHTC | ARTC_LATU

WIRED CONTROLLER#

FEATURES:• Thermo sensor

• Weekly timer

• Easy to understand operation

• Timer and clock display

• Temperature display

76

Page 5: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

B U L K H E A D

ARTG09/12LLLB

ARTG18LLTA

WIRED CONTROLLER

AOTG09/12LBCBAOTG18LACC

O P T I O N A L A U T O L O U V E R G R I L L E K I T F O R B U L K H E A D M O D E L S

The stylish flat Auto Louver shuts when not in use, and provides ideal direction for heating or cooling automatically. The louver is controlled by the indoor unit controller.

OPTIONAL PARTS

Auto Louver Grille Kit : UTD-GXSA-W / UTD-GXSB-WSimple flat Auto Louver will provide comfortairflow and harmonize with luxury interior.

Closed louver Opened louver

OPTIONAL PARTS

Auto Louver Grille Kit : UTD-GXSA-W / UTD-GXSB-WSimple flat Auto Louver will provide comfortairflow and harmonize with luxury interior.

Closed louver Opened louver

• Flexible control

• Operation with indoor unit

• Auto louver can be operated by the remote control of the indoor unit.

• Up, down and auto swing.

• Auto airflow direction.

• 4 selectable louver positions.

• When operation of indoor unit is switched off, the louver will automatically close.

I D E A L W A R M A I R F L O WIdeal warm airflow

Tempe-rature(°C)

40

30

20

2m

Tempe-rature(°C)

40

30

20

2m

Without Auto Louver With Auto Louver[Condition]Model (Indoor unit): ARXD12LATHModel (Auto louver grille): UTD-G*SA-WOutdoor temperature: 2°COperation contents: HeatingSet temperature: 30°Air flow: HiCVertical flap: Downward

[Condition]Model (Indoor unit): ARXD12LATHOutdoor temperature: 2°COperation contents: HeatingSet temperature: 30°CAir flow: Hi

E A S Y , F L E X I B L E I N S T A L L A T I O N

F E A T U R E S C H E C K L I S T

I N T U I T I V E C O N T R O LOperated from an easy-to-use control, you can change the settings for mode, fan speed and set temperature and also program the weekly timer to maintain temperature with minimal fuss.

C O M P A C T D E S I G NBulkhead type ducted Heat Pump/Air Conditioners are designed to allow for flexible installation in the best available space.

Q U I E T A N D E F F I C I E N TQuiet, efficient and easy to maintain, offering perfect comfort for the room it is installed in.

SET CODE SET–ARTG09LLLB SET–ARTG12LLLB SET–ARTG18LLTA

MODEL CODE ARTG09LLLB ARTG12LLLB ARTG18LLTA

FEATURES

All DC components 3 3 3

Auto changeover 3 3 3

Auto restart 3 3 3

Automatic fan speed adjustment 3 3 3

Automatic airflow adjustment

Blue fin heat exchanger 3 3 3

Connectable distributing duct 3 3 3

Control port 3 3 3

Economy mode 3 3 3

Error code display 3 3 3

Fresh air intake 3 3 3

On-Off timer 3 3 3

Weekly timer & setback 3 3 3

Zone control

For Product Specifications turn to page 28

98

Page 6: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

S L I M L I N E

ARTG24LMLCARTA30LBTU

ARTA36/45LATU

AOTA36/45LCTLAOTG24LATCAOTA30LGTL

WIRED CONTROLLER

S L I M, C O M P A C T D E S I G N

I N T U I T I V E C O N T R O LOperated from an easy-to-use control, you can change the settings for mode, fan speed and set temperature and also program the weekly timer to maintain temperature with minimal fuss.

C O M P A C T D E S I G NSlimline type ducted heating/air conditioners are slim and compact in design in order to fit into most ceiling spaces, making it ideal for installation to be discreet.

Q U I E T A N D E F F I C I E N TQuiet, efficient and easy to maintain, offering perfect comfort for the room it is installed in.

F E A T U R E S C H E C K L I S TSET CODE SET–ARTG24LMLC SET–ARTA30LBTU SET–ARTA36LATU SET–ARTA45LATU

MODEL CODE ARTG24LMLC ARTA30LBTU ARTA36LATU ARTA45LATU

FEATURES

All DC components 3 3 3 3

Auto changeover 3 3 3 3

Auto restart 3 3 3 3

Automatic fan speed adjustment 3 3 3 3

Automatic airflow adjustment

Blue fin heat exchanger 3 3 3 3

Control port 3 3 3 3

Connectable distributing duct 3 3 3 3

Connectable fresh air duct 3 3 3 3

Economy mode 3 3 3 3

Fresh air intake 3 3 3 3

Filter sign 3 3 3 3

On-Off timer 3 3 3 3

Program timer 3 3 3 3

Weekly timer 3 3 3 3

Zone control

For Product Specifications turn to page 29

1110

Page 7: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

N E X T G E N S L I M L I N E P L U S

ARTG24/30LHTDP

ARTG36/45/54LHTDP

AOTG45/54LBTBAOTG24LBCA AOTG30/36LBTA

BACKLIT CONTROLLER

S L I M, C O M P A C T D E S I G N

I N T U I T I V E C O N T R O LOperated from an easy-to-use LCD control, you can change the settings for mode, fan speed and set temperature and also program the weekly timer to maintain temperature with minimal fuss.

C O M P A C T A N D F L E X I B L E D E S I G NSlimline type ducted heating/air conditioners are slim and compact in design in order to fit into most ceiling spaces, making it ideal for installation to be discreet. The adjustable static pressure feature along with optional zone controller connectivity allows greater flexibility with installation and adjustable airflow for improved comfort.

Z O N E C O N T R O LDucted Heat Pump/Air Conditioners with zone control capabilities allows for different zones (areas) to be set up in your office or home for optimal comfort and energy management. The system adjusts airflow through dampers at set time periods to control the heating or cooling of the selected zones.

F E A T U R E S C H E C K L I S TSET CODE SET–ARTG24LHTDP SET–ARTG30LHTDP SET–ARTG36LHTDP SET–ARTG45LHTDP SET–ARTG54LHTDP

MODEL CODE ARTG24LHTDP ARTG30LHTDP ARTG36LHTDP ARTG45LHTDP ARTG54LHTDP

FEATURES

All DC components 3 3 3 3 3

Auto changeover 3 3 3 3 3

Auto restart 3 3 3 3 3

Automatic fan speed adjustment 3 3 3 3 3

Automatic air flow adjustment 3 3 3 3 3

Blue fin heat exchanger 3 3 3 3 3

Connectable distributing duct 3 3 3 3 3

Connectable fresh air duct 3 3 3 3 3

Control port 3 3 3 3 3

Economy mode 3 3 3 3 3

Fresh air intake 3 3 3 3 3

On-Off timer 3 3 3 3 3

Program timer 3 3 3 3 3

Weekly timer 3 3 3 3 3

Zone control* 3 3 3 3 3

For Product Specifications turn to page 30 *Option

1312

Page 8: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

AOTG30LBTC AOTG36/45LBTC

ARTG30/36LHTA

ARTG45LHTA

BACKLIT CONTROLLER

H I G H S T A T I C S I N G L E P H A S E – C O M P A C T O U T D O O R

W H O L E H O M E C O M F O R T A N D C O N T R O L

P O W E R S U P P L YUse of single phase power allows for greater flexibility and minimises installation costs as there is no need to upgrade to a three phase power supply.

C O M P A C T D E S I G NThe new outdoor units are much more compact and lightweight offering greater flexibility around installation.

Z O N E C O N T R O LDucted Heat Pump/Air Conditioners with zone control capabilities allows for different zones (areas) to be set up in your office or home for optimal comfort and energy management. The system adjusts airflow through dampers at set time periods to control the heating or cooling of the selected zones.

F E A T U R E S C H E C K L I S TSET CODE SET–ARTG30LBTC SET–ARTG36LBTC SET–ARTG45LBTC

MODEL CODE ARTG30LHTA ARTG36LHTA ARTG45LHTA

FEATURES

All DC components 3 3 3

Auto changeover 3 3 3

Auto restart 3 3 3

Automatic fan speed adjustment 3 3 3

Automatic air flow adjustment

Blue fin heat exchanger 3 3 3

Connectable distributing duct 3 3 3

Connectable fresh air duct 3 3 3

Control port 3 3 3

Economy mode 3 3 3

Filter sign 3 3 3

Fresh air intake 3 3 3

On-Off timer 3 3 3

Program timer 3 3 3

Weekly timer 3 3 3

Zone control* 3 3 3

For Product Specifications turn to page 31 *Option

1514

Page 9: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

H I G H S T A T I C S I N G L E P H A S E

AOTG30/36/45LATLAOTG54LCTL

ARTG30/36LHTA

ARTG45LHTAARTG54LHTC

BACKLIT CONTROLLER

W H O L E H O M E C O M F O R T A N D C O N T R O L

P O W E R S U P P L YUse of single phase power allows for greater flexibility and minimises installation costs as there is no need to upgrade to a three phase power supply.

I N C R E A S E D N U M B E R O F O U T L E T SHigh static ducted heating/air conditioning allows for an increased number of air ducts to be installed.

Z O N E C O N T R O LDucted Heat Pump/Air Conditioners with zone control capabilities allows for different zones (areas) to be set up in your office or home for optimal comfort and energy management. The system adjusts airflow through dampers at set time periods to control the heating or cooling of the selected zones.

F E A T U R E S C H E C K L I S TSET CODE SET–ARTG30LHTA SET–ARTG36LHTA SET–ARTG45LHTA SET–ARTG54LHTC

MODEL CODE ARTG30LHTA ARTG36LHTA ARTG45LHTA ARTG54LHTC

FEATURES

All DC components 3 3 3 3

Auto changeover 3 3 3 3

Auto restart 3 3 3 3

Automatic fan speed adjustment 3 3 3 3

Automatic air flow adjustment

Blue fin heat exchanger 3 3 3 3

Connectable distributing duct 3 3 3 3

Connectable fresh air duct 3 3 3 3

Control port 3 3 3 3

Economy mode 3 3 3 3

Filter sign 3 3 3 3

Fresh air intake 3 3 3 3

On-Off timer 3 3 3 3

Program timer 3 3 3 3

Weekly timer 3 3 3 3

Zone control* 3 3 3 3

For Product Specifications turn to page 32 *Option

1716

Page 10: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

H I G H S T A T I C N E X T G E N S I N G L E P H A S E

AOTG60LBTA

ARTG60LDTA

BACKLIT CONTROLLER

W H O L E H O M E C O M F O R T A N D C O N T R O L

P O W E R S U P P L YUse of single phase power allows for greater flexibility and minimises installation costs as there is no need to upgrade to a three phase power supply.

I N C R E A S E D N U M B E R O F O U T L E T SHigh static ducted heating/air conditioning allows for an increased number of air ducts to be installed.

Z O N E C O N T R O LDucted Heat Pump/Air Conditioners with zone control capabilities allows for different zones (areas) to be set up in your office or home for optimal comfort and energy management. The system adjusts airflow through dampers at set time periods to control the heating or cooling of the selected zones.

F E A T U R E S C H E C K L I S TSET CODE SET–ARTG60LDTA

MODEL CODE ARTG60LDTA

FEATURES

All DC components 3

Auto changeover 3

Auto restart 3

Automatic fan speed adjustment 3

Automatic air flow adjustment 3

Blue fin heat exchanger 3

Connectable distributing duct 3

Connectable fresh air duct 3

Control port 3

Economy mode 3

Filter sign 3

Fresh air intake 3

On-Off timer 3

Program timer 3

Weekly timer 3

Zone control* 3

For Product Specifications turn to page 33 *Option

1918

Page 11: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

T HE SL E E P P U M P™

3 O R 4 ROOM S - S L I M L I N E

SLEEPPUMP24/30

WIRED CONTROLLER

AOTG24LATCAOTA30LGTL

C O M F O R T A N D C O N T R O L F O R T H E B E D R O O M SEntry level central heating systems designed to keep 3 or 4 bedrooms warm in winter, then cool and dehumidify in summer.

F E A T U R E S C H E C K L I S TSET CODE SET–SLEEPPUMP24 SET–SLEEPPUMP30

MODEL CODE SLEEPPUMP24 SLEEPPUMP30

FEATURES

All DC components 3 3

Auto changeover 3 3

Auto restart 3 3

Automatic fan speed adjustment 3 3

Automatic air flow adjustment

Blue fin heat exchanger 3 3

Connectable distributing duct 3 3

Connectable fresh air duct 3 3

Control port 3 3

Economy mode 3 3

Filter sign 3 3

Fresh air intake 3 3

On-Off timer 3 3

Program timer 3 3

Weekly timer 3 3

Zone control

C O M P A C T D E S I G NSlimline type ducted Heat Pump/Air Conditioners are slim and compact in design in order to fit into most ceiling spaces, making it ideal for discreet installation.

Q U I E T A N D E F F I C I E N TQuiet, efficient and easy to maintain, offering perfect comfort for the rooms it is installed in.

For Product Specifications turn to page 34

I N T U I T I V E C O N T R O LOperated from an easy-to-use LCD control, you can change the settings for mode, fan speed and set temperature and also program the weekly timer to maintain temperature with minimal fuss.

2120

Page 12: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

SLEEP24/30LHTDP

AOTG30LBTA

T HE SL E E P P U M P™ 3 O R 4 ROOM S - N E X T G E N S L I M L I N E P L U S

BACKLIT CONTROLLER

AOTG24LBCA

C O M F O R T A N D C O N T R O L F O R T H E B E D R O O M SEntry point central heating systems designed to keep 3 or 4 bedrooms warm in winter, then cool and dehumidify in summer.

F E A T U R E S C H E C K L I S TSET CODE SET–SLEEP24LHTDP SET–SLEEP30LHTDP

MODEL CODE SLEEP24LHTDP SLEEP30LHTDP

FEATURES

All DC components 3 3

Auto changeover 3 3

Auto restart 3 3

Automatic fan speed adjustment 3 3

Automatic air flow adjustment 3 3

Blue fin heat exchanger 3 3

Connectable distributing duct 3 3

Connectable fresh air duct 3 3

Control port 3 3

Economy mode 3 3

Filter sign 3 3

Fresh air intake 3 3

On-Off timer 3 3

Program timer 3 3

Weekly timer 3 3

Zone control

C O M P A C T D E S I G NSlimline type ducted Heat Pump/Air Conditioners are slim and compact in design in order to fit into most ceiling spaces, making it ideal for discreet installation.

Q U I E T A N D E F F I C I E N TQuiet, efficient and easy to maintain, offering perfect comfort for the rooms it is installed in.

For Product Specifications turn to page 34

I N T U I T I V E C O N T R O LOperated from an easy-to-use LCD control, you can change the settings for mode, fan speed and set temperature and also program the weekly timer to maintain temperature with minimal fuss.

2322

Page 13: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

H I G H S T A T I C T H R E E P H A S E

ARTG60LHTA

ARTC72LATU

ARTC90LATU

AOTG60LATT

AOTA72/90LALT

BACKLIT CONTROLLER

W H O L E H O M E C O M F O R T A N D C O N T R O L

Z O N E C O N T R O LDucted heating/air conditioning with zone control capabilities allows for different zones (areas) to be set up in your office or home for optimal comfort and energy management. The system adjusts airflow through dampers at set time periods to control the heating or cooling of the selected zones.

C O M F O R T A N D S T A B I L I T YWith smart technology, the Heat Pump/Air Conditioner works at an optimum setting to create a comfortable environment for your home.

E N E R G Y E F F I C I E N C YWith built in features such as DC fan motors, DC rotary compressors and built in programmable timers, these systems use less power than ever before.

F E A T U R E S C H E C K L I S TSET CODE SET–ARTG60LHTA SET–ARTC72LATU SET–ARTC90LATU

MODEL CODE ARTG60LHTA ARTC72LATU ARTC90LATU

FEATURES

All DC components 3 3 3

Auto changeover 3 3 3

Auto restart 3 3 3

Automatic fan speed adjustment 3 3 3

Automatic air flow adjustment

Blue fin heat exchanger 3 3 3

Connectable distributing duct 3 3 3

Connectable fresh air duct 3 3 3

Control port 3 3 3

Economy mode 3 3 3

Filter sign 3 3 3

Fresh air intake 3 3 3

On-Off timer 3 3 3

Program timer 3 3 3

Weekly timer 3 3 3

Zone control* 3 3 3

For Product Specifications turn to page 35 *Option

2524

Page 14: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

E N E R G Y R E C O V E R Y V E N T I L A T O R S

F R E S H A I R E N E R G Y R E C O V E R Y

E N E R G Y E F F I C I E N C Y A N D E C O L O G YThe cost to provide ventilation is dramatically reduced by using heat exchange technology of a counter flow heat exchanger element. The ERV is capable of recovering up to 77%* of heat energy in the outgoing air.

H U M I D I T Y T R A N S F E RWhen the building is in cooling mode, humidity from the warm outside air is transferred to the exhaust air minimising the effect on the room/s. The opposite occurs when the building is in heating mode where humidity from the exhaust air is transferred to the dry incoming outside air. This is possible because the ERV unit is equipped with a special paper and resin heat exchanger element.

C O S T S A V I N G V E N T I L A T I O NThe ERV works by extracting stale air from inside your home and tempering fresh outside air to replace the stale air extraction. An ERV minimises the need for any additional pre-heating or cooling of incoming outside air.

F E A T U R E S C H E C K L I S TMODEL CODE UTZ-BD025C UTZ-BD035C UTZ-BD050C UTZ-BD080C UTZ-BD100C

FEATURES

Draws in fresh outside air 3 3 3 3 3

Continuous air circulation 3 3 3 3 3

Moisture Extraction 3 3 3 3 3

Fresh Air Supply 3 3 3 3 3

Transfers Humidity 3 3 3 3 3

Heat Exchange 3 3 3 3 3

Normal Ventilation 3 3 3 3 3

Long life heat exchange element 3 3 3 3 3

Dust Removal 3 3 3 3 3

Dehumidification 3 3 3 3 3

Connectable to Ducted 3 3 3 3 3

For Product Specifications turn to page 36 * During conditions at 85% humidity

2726

UTZ-BD025C UTZ-BD050C

LCD CONTROLLER

UTZ-BD035C

UTZ-BD100CUTZ-BD080C

Page 15: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

P R O D U C T S P E C I F I C A T I O N S

Set Code SET–ARTG09LLLB SET–ARTG12LLLB SET–ARTG18LLTA

Model No.Indoor unit ARTG09LLLB ARTG12LLLB ARTG18LLTA

Outdoor unit AOTG09LBCB AOTG12LBCB AOTG18LACC

Operation Type Reverse Cycle Reverse Cycle Reverse Cycle

Power Supply V / Ph / HZ 240 / 1 / 50 240 / 1 / 50 240 / 1 / 50

CapacityCooling kW 2.60 (0.90 - 3.75) 3.50 (0.90 - 4.17) 5.20 (0.90-5.90)

Heating kW 3.50 (0.90 - 5.51) 4.50 (0.90 - 5.96) 6.00 (0.90-7.50)

Input PowerCooling kW 0.66 (Max 1.46) 0.94 (Max 1.51) 1.45 (Max 1.61)

Heating kW 0.83 (Max 1.88) 1.19 (Max 2.09) 1.56 (Max 2.31)

EER Cooling kW / kW 3.94 3.72 3.59

COP Heating kW / kW 4.22 3.78 3.85

AEER Cooling kW / kW 3.824 3.645 3.601

ACOP Heating kW / kW 4.137 3.748 3.850

Running Current Cooling / Heating amps 3.10 / 3.90 4.30 / 5.30 6.10 / 6.60

Moisture Removal l / hr 0.70 1.30 2.00

Noise Level

Indoor Sound Pressure (High/Quiet) dBA 28 / 25 29 / 26 32 / 27

Outdoor Sound Pressure dBA 41 49 55

Outdoor Sound Power dBA 59 62 71

Static Pressure Range PA 0 to 90 0 to 90 0 to 90

Air Circulation (Indoor - High Fan) l / sec 167 181 261

Net Dimensions H x W x D

Indoor Unitmm 198 x 700 x 620 198 x 700 x 620 198 x 900 x 620

kgs 18 18 23

Outdoor Unitmm 620 x 790 x 290 620 x 790 x 290 620 x 790 x 290

kgs 39 39 41

Piping Connections (Liquid / Suction) mm Ø 6.35 / Ø 9.52 Ø 6.35 / Ø 9.52 Ø 6.35 / Ø 12.70

Max Pipe Length (Precharged length) m 20 (15) 20 (15) 30 (15)

Max Height Difference m 15 15 20

Operation RangeCooling °CDB -10 to 46 -10 to 46 -10 to 46

Heating °CDB -15 to 24 -15 to 24 -15 to 24

Refrigerant R410A R410A R410A

B U L K H E A D

Due to ongoing research and development, specifications and designs are subject to improvement without notice therefore relevant manuals must be consulted before any action is taken to install or service these products.

P R O D U C T S P E C I F I C A T I O N SS L I M L I N E

Set code SET–ARTG24LMLC SET–ARTA30LBTU SET–ARTA36LATU SET–ARTA45LATU

Model No.Indoor unit ARTG24LMLC ARTA30LBTU ARTA36LATU ARTA45LATU

Outdoor unit AOTG24LATC AOTA30LGTL AOTA36LCTL AOTA45LCTL

Operation Type Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle

Power Supply V / Ph / HZ 240 / 1 / 50 240 / 1 / 50 240 / 1 / 50 240 / 1 / 50

CapacityCooling kW 7.1 (2.90 - 8.00) 8.50 (2.80 - 10.0) 10.0 (3.8-11.2) 11.5 (4.0-13.3)

Heating kW 8.0 (2.20 - 9.10) 10.00 (2.70 - 11.20) 11.2 (4.0-14.0) 14.0 (4.2-15.5)

Input PowerCooling kW 2.09 (Max 2.40) 2.65 (Max 4.04) 3.11 (Max 4.66) 3.56 (Max 5.02)

Heating kW 2.19 (Max 2.75) 2.68 (Max 4.04) 3.02 (Max 4.78) 4.02 (Max 5.02)

EER Cooling kW / kW 3.40 3.21 3.21 3.23

COP Heating kW / kW 3.65 3.73 3.71 3.48

AEER Cooling kW / kW 3.428 3.193 3.247 3.212

ACOP Heating kW / kW 3.736 3.739 3.688 3.468

Running Current Cooling / Heating amps 8.8 / 9.2 11.1 / 11.2 13.0 / 12.7 14.9 / 16.8

Moisture Removal l / hr 2.50 2.50 3.00 4.00

Noise Level

Indoor Sound Pressure (High/Quiet) dBA 31 / 25 42 / 29 40 / 26 42 / 28

Outdoor Sound Pressure dBA 53 53 54 55

Outdoor Sound Power dBA 68 69 68 69

Static Pressure Range PA 30 to 150 30 to 150 30 to 150 30 to 150

Air Circulation (Indoor - High Fan) l / sec 305 542 514 583

Net Dimensions H x W x D

Indoor Unitmm 270 x 1135 x 700 270 x 1135 x 700 270 x 1135 x 700 270 x 1135 x 700

kgs 38 40 40 40

Outdoor Unitmm 830 x 900 x 330 830 x 900 x 330 1290 x 900 x 330 1290 x 900 x 330

kgs 60 61 86 86

Piping Connections (Liquid / Suction) mm Ø 6.35 / Ø 15.88 Ø 9.52 / Ø 15.88 Ø 9.52 / Ø 15.88 Ø 9.52 / Ø 15.88

Max Pipe Length (Precharged length) m 30 (20) 50 (20) 50 (20) 50 (20)

Max Height Difference m 30 30 30 30

Operation RangeCooling °CDB -10 to 46 -15 to 46 -15 to 46 -15 to 46

Heating °CDB -15 to 24 -15 to 24 -15 to 24 -15 to 24

Refrigerant R410A R410A R410A R410A

Due to ongoing research and development, specifications and designs are subject to improvement without notice therefore relevant manuals must be consulted before any action is taken to install or service these products.

2928

Page 16: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

P R O D U C T S P E C I F I C A T I O N SN E X T G E N S L I M L I N E P L U S

Set code SET–ARTG24LHTDP SET–ARTG30LHTDP SET–ARTG36LHTDP SET–ARTG45LHTDP SET–ARTG54LHTDP

Model No.Indoor unit ARTG24LHTDP ARTG30LHTDP ARTG36LHTDP ARTG45LHTDP ARTG54LHTDP

Outdoor unit AOTG24LBCA AOTG30LBTA AOTG36LBTA AOTG45LBTB AOTG54LBTB

Operation Type Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle

Power Supply V / Ph / HZ 240 / 1 / 50 240 / 1 / 50 240 / 1 / 50 240 / 1 / 50 240 / 1 / 50

CapacityCooling kW 7.10 (2.90 - 8.00) 8.50 (2.80 - 10.00) 10.00 (3.80 - 11.20) 11.50 (4.00 - 13.30) 13.00 (6.20 - 15.20)

Heating kW 8.00 (2.20 - 9.10) 10.00 (2.70 - 11.20) 11.20 (4.00 - 14.00) 14.00 (4.20 - 15.50) 16.00 (6.20 - 18.00)

Input PowerCooling kW 2.08 (Max 4.06) 2.65 (Max 4.06) 3.11 (Max 4.78) 3.33 (Max 5.00) 3.92 (Max 5.58)

Heating kW 2.19 (Max 4.40) 2.70 (Max 4.06) 3.07 (Max 4.76) 3.68 (Max 5.02) 4.45 (Max 5.59)

EER Cooling kW / kW 3.41 3.21 3.22 3.45 3.32

COP Heating kW / kW 3.65 3.70 3.65 3.80 3.60

AEER Cooling kW / kW 3.413 3.245 3.240 3.486 3.360

ACOP Heating kW / kW 3.739 3.696 3.734 3.951 3.644

Running Current Cooling / Heating amps 8.70 / 9.20 11.10 / 11.30 13.00 / 12.90 14.00 / 15.40 16.50 / 18.70

Moisture Removal l / hr 2.20 2.30 2.40 2.60 3.70

Noise Level

Indoor Sound Pressure (High/Quiet) dBA 33 / 21 37 / 29 36 / 26 40 / 29 40 / 29

Outdoor Sound Pressure dBA 55 53 54 55 55

Outdoor Sound Power dBA 69 69 70 69 70

Static Pressure Range PA 30 to 200 30 to 200 30 to 200 30 to 160 30 to 160

Air Circulation (Indoor - High Fan) l / sec 378 472 569 708 708

Net Dimensions H x W x D

Indoor Unitmm 300 x 1000 x 700 300 x 1000 x 700 300 x 1400 x 700 300 x 1400 x 700 300 x 1400 x 700

kgs 36 36 46 46 46

Outdoor Unitmm 620 x 790 x 290 830 x 900 x 330 830 x 900 x 330 1290 x 900 x 330 1290 x 900 x 330

kgs 41 61 61 86 93

Piping Connections (Liquid / Suction) mm Ø 6.35 / Ø 15.88 Ø 9.52 / Ø 15.88 Ø 9.52 / Ø 15.88 Ø 9.52 / Ø 15.88 Ø 9.52 / Ø 15.88

Max Pipe Length (Precharged length) m 30 (15) 50 (20) 50 (20) 50 (20) 75 (30)

Max Height Difference m 20 30 30 30 30

Operation RangeCooling °CDB -10 to 46 -15 to 46 -15 to 46 -15 to 46 -15 to 46

Heating °CDB -15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24

Refrigerant R410A R410A R410A R410A R410A

Due to ongoing research and development, specifications and designs are subject to improvement without notice therefore relevant manuals must be consulted before any action is taken to install or service these products.

P R O D U C T S P E C I F I C A T I O N SH I G H S T A T I C S I N G L E P H A S E C O M P A C T O U T D O O R

Set code SET-ARTG30LBTC SET-ARTG36LBTC SET-ARTG45LBTC

Model No.Indoor unit ARTG30LHTA ARTG36LHTA ARTG45LHTA

Outdoor unit AOTG30LBTC AOTG36LBTC AOTG45LBTC

Operation Type Reverse Cycle Reverse Cycle Reverse Cycle

Power Supply V / Ph / HZ 240 / 1 / 50 240 / 1 / 50 240 / 1 / 50

CapacityCooling kW 8.50 (4.70 - 10.00) 10.00 (5.00 - 11.40) 11.50 (5.70 - 13.50)

Heating kW 10.00 (5.00 - 11.50) 12.50 (5.10 - 14.00) 14.00 (6.00 - 15.50)

Input PowerCooling kW 2.61 (Max 4.06) 3.08 (Max 5.04) 3.70 (Max 5.62)

Heating kW 2.70 (Max 4.06) 3.42 (Max 5.04) 3.84 (Max 5.62)

EER Cooling kW / kW 3.26 3.25 3.11

COP Heating kW / kW 3.70 3.65 3.65

AEER Cooling kW / kW 3.243 3.241 3.109

ACOP Heating kW / kW 3.897 3.732 3.741

Running Current Cooling / Heating amps 11.00 / 11.30 13.00 / 14.40 15.50 / 16.10

Moisture Removal l / hr 0.90 1.50 0.90

Noise Level

Indoor Sound Pressure (High/Low) dBA 41 / 36 41 / 36 43 / 35

Outdoor Sound Pressure dBA 53 52 58

Outdoor Sound Power dBA 69 68 72

Static Pressure Range PA 60 to 210 60 to 210 60 to 260

Air Circulation (Indoor - High Fan) l / sec 695 695 903

Net Dimensions H x W x D

Indoor Unitmm 400 x 1050 x 500 400 x 1050 x 500 425 x 1250 x 490

kgs 39 39 54

Outdoor Unitmm 830 x 900 x 330 914 x 970 x 370 914 x 970 x 370

kgs 61 75 75

Piping Connections (Liquid / Suction) mm Ø 9.52 / Ø 15.88 Ø 9.52 / Ø 15.88 Ø 9.52 / Ø 15.88

Max Pipe Length (Precharged length) m 50 (20) 50 (20) 50 (20)

Max Height Difference m 30 30 30

Operation RangeCooling °CDB -15 to 46 -15 to 46 -15 to 46

Heating °CDB -15 to 24 -15 to 24 -15 to 24

Refrigerant R410A R410A R410A

Due to ongoing research and development, specifications and designs are subject to improvement without notice therefore relevant manuals must be consulted before any action is taken to install or service these products.

3130

Page 17: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

H I G H S T A T I C S I N G L E P H A S E

Set code SET–ARTG30LHTA SET–ARTG36LHTA SET–ARTG45LHTA SET–ARTG54LHTC

Model No.Indoor unit ARTG30LHTA ARTG36LHTA ARTG45LHTA ARTG54LHTC

Outdoor unit AOTG30LATL AOTG36LATL AOTG45LATL AOTG54LCTL

Operation Type Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle

Power Supply V / Ph / HZ 240 / 1 / 50 240 / 1 / 50 240 / 1 / 50 240 / 1 / 50

CapacityCooling kW 9.00 (4.70 - 10.00) 10.50 (5.00 - 11.40) 12.50 (5.70 - 14.00) 14.00 (6.20 - 15.20)

Heating kW 11.20 (5.00 - 12.10) 12.10 (5.10 - 14.00) 14.00 (6.00 - 16.00) 16.00 (6.20 - 18.00)

Input PowerCooling kW 2.70 (Max 4.30) 3.18 (Max 4.67) 4.03 (Max 5.38) 4.40 (Max 5.63)

Heating kW 2.95 (Max 4.30) 3.30 (Max 4.80) 3.80 (Max 5.38) 4.37 (Max 5.63)

EER Cooling kW / kW 3.33 3.30 3.10 3.18

COP Heating kW / kW 3.80 3.67 3.68 3.66

AEER Cooling kW / kW 3.350 3.338 3.205 3.166

ACOP Heating kW / kW 3.799 3.697 3.669 3.690

Running Current Cooling / Heating amps 11.40 / 12.40 13.40 / 13.90 16.90 / 16.00 18.40 / 18.30

Moisture Removal l / hr 1.00 1.50 1.00 1.50

Noise Level

Indoor Sound Pressure (High/Low) dBA 41 / 36 41 / 36 43 / 35 45 / 36

Outdoor Sound Pressure dBA 52 52 55 55

Outdoor Sound Power dBA 67 68 69 70

Static Pressure Range PA 60 to 210 60 to 210 60 to 260 60 to 260

Air Circulation (Indoor - High Fan) l / sec 695 695 903 986

Net Dimensions H x W x D

Indoor Unitmm 400 x 1050 x 500 400 x 1050 x 500 425 x 1250 x 490 425 x 1250 x 490

kgs 39 39 54 54

Outdoor Unitmm 1290 x 900 x 330 1290 x 900 x 330 1290 x 900 x 330 1290 x 900 x 330

kgs 86 86 86 93

Piping Connections (Liquid / Suction) mm Ø 9.52 / Ø 15.88 Ø 9.52 / Ø 15.88 Ø 9.52 / Ø 15.88 Ø 9.52 / Ø 15.88

Max Pipe Length (Precharged length) m 50 (20) 50 (20) 50 (20) 75 (30)

Max Height Difference m 30 30 30 30

Operation RangeCooling °CDB -5 to 46 -5 to 46 -5 to 46 -15 to 46

Heating °CDB -15 to 24 -15 to 24 -15 to 24 -15 to 24

Refrigerant R410A R410A R410A R410A

P R O D U C T S P E C I F I C A T I O N S

Due to ongoing research and development, specifications and designs are subject to improvement without notice therefore relevant manuals must be consulted before any action is taken to install or service these products.

P R O D U C T S P E C I F I C A T I O N SH I G H S T A T I C N E X T G E N S I N G L E P H A S E

Set code SET–ARTG60LDTA

Model No.Indoor unit ARTG60LDTA

Outdoor unit AOTG60LBTA

Operation Type Reverse Cycle

Power Supply V / Ph / HZ 240 / 1 / 50

CapacityCooling kW 15.80 (6.20 - 16.30)

Heating kW 18.00 (6.20 - 18.50)

Input PowerCooling kW 4.92 (Max 6.15)

Heating kW 4.99 (Max 6.18)

EER Cooling kW / kW 3.21

COP Heating kW / kW 3.61

AEER Cooling kW / kW 3.225

ACOP Heating kW / kW 3.718

Running Current Cooling / Heating amps 20.70 / 21.00

Moisture Removal l / hr 2.10

Noise Level

Indoor Sound Pressure (High/Quiet) dBA 44 / 35

Outdoor Sound Pressure dBA 57

Outdoor Sound Power dBA 72

Static Pressure Range PA 60 to 250

Air Circulation (Indoor - High Fan) l / sec 1139

Net Dimensions H x W x D

Indoor Unitmm 360 x 1400 x 850

kgs 69

Outdoor Unitmm 1290 x 900 x 330

kgs 97

Piping Connections (Liquid / Suction) mm Ø 9.52 / Ø 15.88

Max Pipe Length (Precharged length) m 75 (30)

Max Height Difference m 30

Operation RangeCooling °CDB -15 to 46

Heating °CDB -15 to 24

Refrigerant R410A

Due to ongoing research and development, specifications and designs are subject to improvement without notice therefore relevant manuals must be consulted before any action is taken to install or service these products.

3332

Page 18: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

P R O D U C T S P E C I F I C A T I O N SS L E E P P U M P™

Set code SET–SLEEPPUMP24 SET–SLEEPPUMP30 SET–SLEEP24LHTDP SET–SLEEP30LHTDP

Model NoIndoor unit ARTG24LMLC ARTA30LBTU ARTG24LHTDP ARTG30LHTDP

Outdoor unit AOTG24LATC AOTA30LGTL AOTG24LBCA AOTG30LBTA

Operation Type Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle

Power Supply V / Ph / Hz 240 / 1 /50 240 / 1 /50 240 / 1 /50 240 / 1 /50

CapacityCooling kW 7.1 (2.90 - 8.00) 8.5 (2.80 - 10.00) 7.1 (2.90 - 8.00) 8.5 (2.80 - 10.00)

Heating kW 8.0 (2.20 - 9.10) 10.0 (2.70 - 11.20) 8.0 (2.20 - 9.10) 10.0 (2.70 - 11.20)

Input PowerCooling kW 2.09 (Max 2.4) 2.65 (Max 4.04) 2.08 (Max 4.06) 2.65 (Max 4.06)

Heating kW 2.19 (Max 2.75) 2.68 (Max 4.04) 2.19 (Max 4.40) 2.70 (Max 4.06)

EER Cooling kW / kW 3.40 3.21 3.41 3.21

COP Heating kW / kW 3.65 3.73 3.65 3.70

AEER Cooling kW / kW 3.428 3.193 3.413 3.245

ACOP Heating kW / kW 3.736 3.739 3.739 3.696

Running Current Cooling / Heating Amps 8.8 / 9.2 11.1 / 11.2 8.7 / 9.2 11.1 / 11.3

Moisture Removal l / hr 2.50 2.50 2.20 2.30

Noise Level

Indoor Sound Pressure (High/Quiet) dBA 31 / 25 42 / 29 33 / 21 37 / 29

Outdoor Sound Pressure dBA 53 53 55 53

Outdoor Sound Power dBA 68 69 69 69

Static Pressure Range Pa 30 to 150 30 to 150 30 to 200 30 to 200

Air Circulation (Indoor - High Fan) l / sec 305 542 378 472

Net Dimensions H x W x D

Indoor Unitmm 270 x 1135 x 700 270 x 1135 x 700 300 x 1000 x 700 300 x 1000 x 700

kg 38 40 36 36

Outdoor Unitmm 830 x 900 x 330 830 x 900 x 330 620 x 790 x 290 830 x 900 x 330

kg 60 61 41 61

Piping Connections (Liquid / Suction) mm Ø 6.35 / Ø 15.88 Ø 9.52 / Ø 15.88 Ø 6.35 / Ø 15.88 Ø 9.52 / Ø 15.88

Max Pipe Length (Precharged length) m 30 (20) 50 (20) 30 (15) 50 (20)

Max Height Difference m 30 30 20 30

Operation RangeCooling °C DB -10 to 46 -15 to 46 -10 to 46 -15 to 46

Heating °C DB -15 to 24 -15 to 24 -15 to 24 -15 to 24

Refrigerant R410A R410A R410A R410A

Due to ongoing research and development, specifications and designs are subject to improvement without notice therefore relevant manuals must be consulted before any action is taken to install or service these products.

H I G H S T A T I C T H R E E P H A S E

Set code SET–ARTG60LHTA SET–ARTC72LATU SET–ARTC90LATU

Model No.Indoor unit ARTG60LHTA ARTC72LATU ARTC90LATU

Outdoor unit AOTG60LATT AOTA72LALT AOTA90LALT

Operation Type Reverse Cycle Reverse Cycle Reverse Cycle

Power Supply V / Ph / HZ 415 / 3 / 50 415 / 3 / 50 415 / 3 / 50

CapacityCooling kW 15.00 (6.20 - 17.50) 20.30 (10.80 - 23.50) 25.00 (11.20 - 28.00)

Heating kW 18.00 (6.20 - 20.00) 22.60 (12.00 - 26.50) 28.00 (12.50 - 31.50)

Input PowerCooling kW 4.70 (Max 7.40) 6.25 (Max 10.10) 7.82 (Max 12.50)

Heating kW 5.15 (Max 7.40) 6.27 (Max 10.10) 8.24 (Max 12.50)

EER Cooling kW / kW 3.19 3.25 3.20

COP Heating kW / kW 3.50 3.60 3.40

AEER Cooling kW / kW 3.174 3.315 3.172

ACOP Heating kW / kW 3.483 3.698 3.505

Running Current Cooling / Heating amps 6.70 / 7.30 9.30 / 9.30 11.50 / 12.10

Moisture Removal l / hr 2.00 4.50 6.00

Noise Level

Indoor Sound Pressure (High/Low) dBA 45 / 36 47 / 41 49 / 43

Outdoor Sound Pressure dBA 56 57 58

Outdoor Sound Power dBA 71 74 76

Static Pressure Range PA 60 to 260 50 to 250 50 to 250

Air Circulation (Indoor - High Fan) l / sec 986 1195 1347

Net Dimensions H x W x D

Indoor Unitmm 425 x 1250 x 490 450 x 1587 x 700 550 x 1587 x 700

kgs 54 100 110

Outdoor Unitmm 1290 x 900 x 330 1690 x 930 x 765 1690 x 930 x 765

kgs 104 215 215

Piping Connections (Liquid / Suction) mm Ø 9.52 / Ø 15.88 Ø 12.70 / Ø 25.40 Ø 12.70 / Ø 25.40

Max Pipe Length (Precharged Length) m 75 (30) 75 (20) 75 (20)

Max Height Difference m 30 30 30

Operation RangeCooling °CDB -15 to 46 -5 to 46 -5 to 46

Heating °CDB -15 to 24 -15 to 24 -15 to 24

Refrigerant R410A R410A R410A

Due to ongoing research and development, specifications and designs are subject to improvement without notice therefore relevant manuals must be consulted before any action is taken to install or service these products.

P R O D U C T S P E C I F I C A T I O N S

3534

Page 19: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

P R O D U C T S P E C I F I C A T I O N SE N E R G Y R E C O V E R Y V E N T I L A T O R

Model No Outdoor unit UTZ-BD025C UTZ-BD035C UTZ-BD050C UTZ-BD080C UTZ-BD100C

Power Supply V / Ph / Hz 240 / 1 / 50 240 / 1 / 50 240 / 1 / 50 240 / 1 /50 240 / 1 /50

Input Power

Extra High kW 112 - 128 182 - 190 263 - 289 387 - 418 437 - 464

High kW 108 - 123 178 - 185 204 - 225 360 - 378 416 - 432

Low kW 87 - 96 175 - 168 165 - 185 293 - 295 301 - 311

Air Volume

Extra High m3/h (l/s) 250 350 500 800 1000

High m3/h (l/s) 250 350 500 800 1000

Low m3/h (l/s) 190 240 440 630 700

External Static Pressure

Extra High Pa 105 140 120 140 105

High Pa 95 60 60 110 80

Low Pa 45 45 35 55 75

Temperature Exchange Efficiency

Heat Exchange Ventilation % 75 - 77 75 - 78 75 - 76 75 - 76 75 - 79

Normal Ventilation N/A N/A N/A N/A N/A

Sound Pressure Level

Extra High dB 30.0 - 31.5 32.5 - 33.0 36.5 - 37.5 37.0 - 37.5 37.5 - 38.5

High dB 29.5 - 30.5 30.5 - 31.0 34.5 - 35.5 36.5 - 37.0 37.0 - 37.5

Low dB 23.5 - 26.5 22.5 - 25.5 31.0 - 32.5 33.5 - 34.5 33.5 - 34.5

Net Dimensions H x W x D mm 270 x 882 x 599 317 x 1050 x 804 317 x 1090 x 904 388 x 1322 x 884 388 x 1322 x 1134

Outlet Duct Diameter mm 150 150 200 250 250

Maximum Humidity % 85 85 85 85 85

Operation Range °C DB - 10 to 40 - 10 to 40 - 10 to 40 - 10 to 40 - 10 to 40

Due to ongoing research and development, specifications and designs are subject to improvement without notice therefore relevant manuals must be consulted before any action is taken to install or service these products.

36 37

Page 20: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

34

S P E C I F I C A T I O N S

Products in this brochure contain R410A refrigerant. Please refer to specifications before installing and servicing this product. Only persons and / or companies qualified and experienced in the installation, service and repair of refrigerant products should be permitted to do so. The purchaser must ensure that the person and / or company who is to install, service or repair this heating/air conditioner has qualifications and experience in refrigerant products.Suitable access for warranty and service is required. Future improvements, specifications, designs of product and availability are subject to change without notice. Please check with your Dealer.

Indoor temperature 27°C DB / 19°C WBOutdoor temperature 35°C DB

Running current is at rated conditions (AS3823) and does not include compressor start-up or variations in power supply and load conditions.

ALL CAPACITY AND ENERGY EFFICIENCY RATINGS ARE BASED ON AS / NZS3823.2.

COOLING

HEATINGIndoor temperature 20°C DB Outdoor temperature 7°C DB / 6°C WB

P R O D U C T S P E C I F I C A T I O N S

Like all Kiwis, I put the comfort of my family first.

Installing a Fujitsu will keep you comfortable all year round and ensure you wake up & arrive home to a fresher more comfortable home.

Our Heat Pump/Air Conditioners are efficient, effective and beautifully designed. You can trust Fujitsu. It’s New Zealand’s Favourite Air ®.

3938

Page 21: DUCTED RANGE · 7 kh xv h ri d khd wsx ps fr sduhg dqgd ug f hoh fwu l khd whv r v wljql il dq o\ ohvv wr rshud wh ,q i f wlq klv [ p ri kh d p rx sx z loo khd lqjvhd rxu d y rxog

WHY FUJITSU?

Fujitsu is recommended by Asthma New Zealand

Fujitsu’s Catechin Filters are approved by the Asthma and Respiratory Foundation NZ’s Sensitive Choice® programme.

ACCREDITEDINSTALLER

Fujitsu General accepts no liability for incorrect data. Please ensure you have confirmed installation requirements and pipe sizes prior to install.

August 2019

FUJITSU GENERAL NEW ZEALANDA SUBSIDIARY OF FUJITSU GENERAL LIMITED

fujitsugeneral.co.nz