dual output infrared heaters · environment, duh model. model du. heavy duty industrial/commercial...
TRANSCRIPT
• Rates 40,000 to 220,000 BTU/HR• Separated controls compartment• Self-diagnostic ignition module• Parabolic aluminum reflectors• Heavy duty couplings• Direct spark ignition• 24V direct wire for thermostat• Jet stream burner• Vented or unvented
DUAL OUTPUTINFRARED HEATERS
DU/DUH RANGEAdvanced Radiant Systems’ Dual Output Range (DU/DUH) offers the efficiency benefits of two-stage heating at an economical cost. These units also minimize temperature swings and help avoid system cycling therefore optimizing fuel consumption.
The two-stage units are offered in both the standard grade, DU model, as well as our harsh environment, DUH model.
Model DUHeavy duty industrial/commercial dual output infrared heater with an enclosed burner.
Model DUHIn addition to all the features of the DU, the DUH also includes a potted module, sealed burner housing and heat-treated aluminized tube for harsh environments. Stainless steel available.
The DU/DUH Range gives the system designer the flexibility to meet the changing demands in a given area. Uniform heating and low up front cost make the Dual Output Range one of our most popular models.
GENERAL SPECIFICATIONS
DIMENSIONS
Model No.HigH Fire rate
BTU/HR
low Fire rate
BTU/HR
MiN/Max
leNgtHFeeT
MiNiMuM clearaNce to coMbustiblesstraigHt 0° Angle
straigHt 45° Angle
u-beNd 0° Angle
top side 1 side 2 below top side 1 side 2 below top side 1 side 2 below
DU/DUH-40 40,000 30,000 10 - 20 2″ 18″ 18" 45″ 4″ 4" 38" 40" - - - -DU/DUH-60 60,000 45,000 15* - 30 2″ 25″ 25" 58″ 4″ 4″ 46" 50″ 2" 25" 22" 59"DU/DUH-80 80,000 60,000 20 - 40 2″ 26″ 26" 62″ 4" 4" 50" 58" 2" 28" 26" 62"DU/DUH-100 100,000 75,000 20 - 50 2″ 30″ 30" 67″ 4" 4" 58" 67" 2" 30" 30" 71"DU/DUH-125 125,000 95,000 30 - 50 4″ 33″ 33" 71″ 6" 4" 63" 70" 4" 34" 33" 74"DU/DUH-150 150,000 115,000 40 - 60 4″ 36″ 36" 74″ 6" 4" 64" 71" 4" 37" 36" 76"DU/DUH-175 175,000 130,000 50 - 60 6″ 40" 40″ 78″ 8" 4" 67" 74" 6" 40" 40" 78"DU/DUH-205 205,000 160,000 50 - 70 6″ 44″ 44" 80″ 8" 4" 72" 78" 6" 45" 44" 82"DU/DUH-220 220,000 165,000 60 - 70 6″ 46″ 46" 83″ 8" 4" 77" 81" 6" 46" 46" 88"This table includes special configurations. Other layout configurations are approved. Side reflectors and lower shields are available. Lower clearances are allowable at 25' from the burner. See installation/operation manual for complete information. *NG Only
18"
36"
6"
16"
12"
12"
14"
15"
9"14"
9"
• U configuration may be unequal length• L configuration availableNOT TO SCALE
Standard Equipment• Burner housing assembly• Aluminized combustion tube with gasket• Combustion air inlet collar• Turbulators when required• All tubes, reflectors, couplings, end caps and
hanging accessories per specified lengthOptional Equipment
• U or L bends for specific layouts• Side shield and brackets• Thermostats, 24V or 120V• Termination vent• Hot rolled, aluminized or stainless steel tube
Gas SupplyInlet Pressure
• NG Min 5.0" W.C.• NG Max 14.0" W.C.
• LPG Min 11.5" W.C.• LPG Max 14.0" W.C.
Inlet ConnectionNG or LPG: 1/2" NPT
Electric Supply120 V AC, 60 HZ, 1 Amp: 36" cord, grounded 3 prong plug
Flue and Outside Air Connection4" O.D. connection for flue adapter and outside air (optional) provided at the heater
DISTRIBUTOR315 N. Madison StreetFortville, IN 46040800-874-3285tel 317-577-0337 | fax [email protected]
www.AdvancedRadiantSystems.com• Operation Manuals• Specifications• Submittal Data
• Parts and Service• Other Products• Weights
Due to continuous product inovations, we reserve the right to change product specifications without due notice.