DUAL CompactAir cooler – dual discharge, compact
DHFR-404A, R-134a, …50 Hz2 – 15 KW
TECHNICAL DATA
32 Subject to technical changes. Subject to technical changes.
Blow-through
1 – 4
IP 44: 350 mm
Staggered tube arrange-ment
Fin spacing: 4 mm
Air-flow direction
Fans
Heat exchanger
Suitable applications
Refrigerant/capacity
Available defrosting types
Circulating air Electric Hot gas Brine Water
Coil
Technical details
Available material
Room temperatures above 0 °C Picking areas Corridors Sales rooms
Refrigerant t0 Air inlet Fin spacing4 mm
DHF N HFC -8 °C 0 °C 2.86 – 15.32 kW
DHF L1 HFC -8 °C 0 °C 2.29 – 11.89 kW
DHF L2 HFC 1.95 – 9.62 kW
Tray Fin Casing Tube
AlMg
Aluminium
Copper
Aluminium, epoxy resin-coated
Standard version
DUAL Compact
DHFAir cooler – dual discharge, compact
2 – 15 kW
Advantages – Flat design – Even air distribution – Low draught air level – Short delivery times with units in stock
Easy mounting – Ceiling mounting brackets with slotted hole for easy installation
– Fans wired to terminal box – Empty tube for defrost sensor – Easily removable side cover – Only one condensation water drain per unit – Schrader valve at outlet
Inspection and cleaning – Hinged tray and heating sheet, drain pipe does not have to be dismantled
HACCP hygiene certificate – All materials used are food-safe – All components are easy to clean – Visual inspection of the entire unit possible – Support bracket flush with upper surface of casing
Heat exchanger – Staggered tube pattern – Internally-ribbed special copper pipes for HFC – Surface-corrugated aluminium fins for high heat exchange
Casing – Corrosion-resistant aluminium alloy AlMg – Powder coating in RAL 9003
High quality tray design – Corrosion-resistant aluminium alloy AlMg – Powder coating in RAL 9003 – Separate drip tray – Thermally decoupled tray (condensation free) – Collection tray for condensation with only one drain
Fans – Tried-and-tested quality fans – 3 fan types for different sound levels – Internal motor protection with thermocontacts – Factory-wired to terminal box – 230 V, 1~, 50 Hz or 60 Hz
Options / Accessories – Epoxy resin-coated fins – Electric defrost heater for coil, wired on connection socket
– Factory-fitted thermostatic expansion valve
Available option
54
� Aluminium fins � Fin spacing: 4 mm � Tubes staggered in air-flow direction � Special copper tubes: Ø 12 mm � Schrader valve at outlet
The capacity specifications apply to R-404A.The cooling capacity ratings refer to an air inlet temperature differential derived from the difference between the air inlet temperature at the cooler tL1 and the evaporating tempera-ture to, dT1 = tL1 – to.
These conditions are marked with dT1 and comply with the requirements of EN 328 and the Eurovent certification.
Our Güntner Product Calculator design software provides you with a thermodynamic design with capacity specifications compliant with Eurovent. This program provides a safe and easy way of configuring a suitable switch cabinet containing the appropriate control and regulation components.
� Aluminium-magnesium alloy, powder-coated in RAL 9003 (signal white)
� Stainless steel brackets for ceiling mounting flush with upper surface of casing
� Electric defrosting for coils and trays, factory-fitted � Electric defrosting for coils and trays, in set for on-site installation
� Epoxy resin-coated fins
� Aluminium-magnesium alloy, powder-coated in RAL 9003, thermally decoupled, polyamide condensation water drain, G thread with flat sealing compliant with DIN ISO 228-1
� Inner and outer trays hinged and removable for easy cleaning
Quality standard for hygiene certified by TÜV SÜD: The units are easy to clean and are particularly suitable for foodstuff processing applications since they are also approved for all materials used in contact with food.
The operation of units below a cold room temperature of -25 °C requires a special design.
Please contact our Sales team for further information.
� Low-noise axial fans with two preset speed settings, wired as standard
� IP 54 in acc. with DIN 40050 � Temperature range: -30 °C to +40 °C � Protection guard in acc. with EN 294 � Internal motor protection � Thermal class 130 (B) � AC fan, 230 V, 1~, 50 Hz
The second stage of the ErP Directive requiring mandatory minimum efficiency levels for fans came into effect on 1 January 2015. The products affected include products with built-in fans whose optimum input power is higher than 125 W. Conformity with the ErP Directive is explicitly indicated for units designed with the Güntner Product Calculator (GPC).
Capacity
Note
ErP Directive
Cooler coil
Casing
Options
Drip tray
Fans
Subject to technical changes. Subject to technical changes.
DHF | Designs
HACCP
76
DHF 035A/14-L2 1.9 11.5 1080 750 4 VT037U 0.05 0.20 B
DHF 035A/14-L1 2.2 11.5 1460 900 6 VT037U 0.06 0.27 C
DHF 035A/14-N 2.8 11.5 2290 1380 8 VT038 0.16 0.72 D
DHF 035B/14-L2 2.3 17.3 990 750 4 VT037U 0.05 0.20 B
DHF 035B/14-L1 2.9 17.3 1375 900 6 VT037U 0.06 0.27 B
DHF 035B/14-N 3.8 17.3 2140 1380 8 VT038 0.16 0.72 D
DHF 035A/24-L2 3.8 23.1 2160 750 5 VT037U 0.10 0.20 B
DHF 035A/24-L1 4.5 23.1 2920 900 7 VT037U 0.12 0.27 C
DHF 035A/24-N 5.6 23.1 4580 1380 11 VT038 0.32 0.72 D
DHF 035B/24-L2 4.7 34.6 1980 750 5 VT037U 0.10 0.20 B
DHF 035B/24-L1 5.8 34.6 2750 900 7 VT037U 0.12 0.27 B
DHF 035B/24-N 7.6 34.6 4280 1380 11 VT038 0.32 0.72 D
DHF 035A/34-L2 5.7 34.6 3240 750 5 VT037U 0.14 0.20 B
DHF 035A/34-L1 6.7 34.6 4380 900 7 VT037U 0.19 0.27 C
DHF 035A/34-N 8.6 34.6 6870 1380 11 VT038 0.48 0.72 D
DHF 035B/34-L2 7.0 52.0 2970 750 5 VT037U 0.14 0.20 B
DHF 035B/34-L1 8.67 52.0 4125 900 7 VT037U 0.19 0.27 B
DHF 035B/34-N 11.4 52.0 6420 1380 11 VT038 0.48 0.72 D
DHF 035A/44-L2 7.6 46.2 4320 750 5 VT037U 0.19 0.20 B
DHF 035A/44-L1 8.9 46.2 5840 900 7 VT037U 0.25 0.27 C
DHF 035A/44-N 11.2 46.2 9160 1380 12 VT038 0.64 0.72 D
DHF 035B/44-L2 9.3 69.3 3960 750 5 VT037U 0.19 0.20 B
DHF 035B/44-L1 11.6 69.3 5500 900 7 VT037U 0.25 0.27 B
DHF 035B/44-N 15.2 69.3 8560 1380 12 VT038 0.64 0.72 D
35.6 57 2.8 230V-4x0.35kW dhf1 916 908 270 660 31 16 18
42.6 64 2.8 230V-4x0.35kW dhf1 916 908 270 660 31 16 18
52.6 74 2.8 230V-4x0.35kW dhf1 916 908 270 660 31 16 18
35.6 57 4.1 230V-4x0.35kW dhf1 916 908 270 660 35 16 18
42.6 64 4.1 230V-4x0.35kW dhf1 916 908 270 660 35 16 18 52.6 74 4.1 230V-4x0.35kW dhf1 916 908 270 660 35 16 18
38.4 60 5.3 230V-4x0.65kW dhf2 1516 908 270 1260 56 16 28
45.4 67 5.3 230V-4x0.65kW dhf2 1516 908 270 1260 56 16 28 55.4 77 5.3 230V-4x0.65kW dhf2 1516 908 270 1260 56 16 28
38.4 60 7.6 230V-4x0.65kW dhf2 1516 908 270 1260 67 16 28
45.4 67 7.6 230V-4x0.65kW dhf2 1516 908 270 1260 67 16 28
55.4 77 7.6 230V-4x0.65kW dhf2 1516 908 270 1260 67 16 28
39.9 62 7.3 230V-4x0.65kW dhf3 2116 908 270 1860 81 16 28
46.9 69 7.3 230V-4x0.65kW dhf3 2116 908 270 1860 81 16 28
56.9 79 7.3 230V-4x0.65kW dhf3 2116 908 270 1860 81 16 28
39.9 62 10.8 230V-4x0.65kW dhf3 2116 908 270 1860 91 16 28
46.9 69 10.8 230V-4x0.65kW dhf3 2116 908 270 1860 91 16 28
56.9 79 10.8 230V-4x0.65kW dhf3 2116 908 270 1860 91 16 28
40.9 63 9.6 230V-4x0.8kW dhf5 2716 908 270 1230 106 16 28
47.9 70 9.6 230V-4x0.8kW dhf5 2716 908 270 1230 106 16 28
57.9 80 9.6 230V-4x0.8kW dhf5 2716 908 270 1230 106 16 28
40.9 63 14.0 230V-4x0.8kW dhf5 2716 908 270 1230 130 16 28
47.9 70 14.0 230V-4x0.8kW dhf5 2716 908 270 1230 130 16 28
57.9 80 14.0 230V-4x0.8kW dhf5 2716 908 270 1230 130 16 28
50 HzNumber of fans
Nominal capacity R-404A
Surface Air volume flow
Fan speed Air throw*
Fan type Power consump-tion
Current Energy efficiency class
Fin spacing Defrost SC2 Pel total
DT1 = 8 K to = -8 °C
4 mm electric kW m2 m3/h rpm m kW A
DHF for HFC | Capacity tables
4 mmE
electric
Subject to technical changes. Subject to technical changes.
AC 50 4EC 60 7
HzE
EAmm mmHFCCO2
Fluid
ACSound pressure
Sound power level
Tube volume
mounted el. defrost/Coil and drip tray
Sketch unittype
Dimensions Net weight Connections refrigerant
In stock
El. voltage / Power consumption
L B H E Inlet Outlet
dB(A) 3 m dB(A) l mm mm mm mm kg mm Ø mm Ø
* measurable up to 0.5 m/s
98
DHF 2 N E4035 A/
DHF | Sketches
Subject to technical changes.
Refrigerant
Fin material
fR SC 2 fR SC 3
fM factor
R-507
Aluminium
R-134a
Aluminium-coated
0.97
0.91
0.97
1
0.85
0.97
Correction factors (fR)for other refrigerantsacc. to Eurovent
Correction factors (fM)for other fin materials acc. to Eurovent
Effective refrigerating capacity Q0 = nominal refrigerating capacity Q0N × correction factor fR
SC2 = standard condition dT1 = 8 K, to = -8 °CSC3 = Standard condition dT1 = 7 K, to = -25 °C
Effective refrigerating capacity Q0 = nominal refrigerating capacity Q0N × correction factor fM
Correction factors acc. to Eurovent
Nomenclature
Model range
Fan with ∅ 350 mm
Coil dimensions
Number of fans Fin pattern : 4 mm
Standard design = N Low noise level design = L
Defrosting:A = Air defrost
E = Electric defrost
Subject to technical changes.
3 mounting brackets (E/2) for: DHF 035 A/44 and DHF 035 B/44
1110
Güntner GmbH & Co. KGHans-Güntner-Str. 2 – 682256 FürstenfeldbruckGERMANY
www.guentner.de
Members of Güntner Group