DSP Arm Controller Control Box SETTINGS Overview
© 2019 Maximum Controls LLC. All rights reserved.
Maximum Controls LLC.10530 Lawson River Ave
Fountain Valley, Ca 92708Tel: (949) 699-0220
EXIT PWR
ALARM
POWER /SOLAR IN
BATTERYINPU T
OPENIN G C LOSIN G
MOTOR 2MOTOR 1
ER D
OBD PORTBLACK BO X
PROGRAMMING
SOLAR MODE
MOTO ROVERLOAD
ER D
MOTO ROVERLOAD MIN M AX
OF F
MA XSENSE
MA XSENS E
BATTERYBACKUP MODE
ERD SENSITIVITY
MOTION CONTRO L
OPEN
CLOSING GATE SPEED
MOTOR 2LIMITS
MA GLOC K
ULENTRAP
STOP CLOS E
CLOS ETIMER
MAGLOC KDELA Y
JOG
BATTERYTEST
BATTERY
INPU TERRO R
BATTERYIN US E
POWER
REPLAC EBATTERY
LEAVECLOSED
LEAVEOPEN
OPEN1 TIME
BATTERY VOLTAGEE F1/2
RESET
IDPLU G
MODUL EPOR T
GATE OPEN
GN D
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NCOPEN / CLS NC
GN D12VDC OU T
GN D
GND
GND
GND
GND
JOG
CLOS
EJO
G OP
EN
TAM
PER
IN
TAM
PER
NO
GATE
DISA
BLE
KEYP
AD/CA
RD
GND
GND
MAX
OPE
N
FIRE
DEP
T
RADI
O GN
DRA
DIO
SIGN
AL
STRI
KE
CLOS
ECO
M
COM
STOP
OPEN
PHOTO CLS 10KOPEN / CLS 10K
12VDC OU T
NOCO M
NC
CO MGATE CLOSED
LIMIT 1GN D
LIMIT 2
MOTOR 1LIMITS
MOTOR 1
MOTOR 2
LIMIT 1GN D
LIMIT 2
LIMIT 1LIMIT 2LIMIT 1LIMIT 2
ID PLUGERRO R
24VDC OUTPU T
12VDC OUTPU T
GN D
GN D
GN D
LOOPLOOP PWR
LOOP
CENTER
SAFETY
OFF
SINGLE
OPEN
ON/OFFBATTERY
CLOS E
DUAL
ON
ANTI -TAILGATE
PUSHOPEN
PULLOPEN
GATEOFF
123456789
10OFF
123456
MIN MIN
MA X MA X
ON
OFF 2.5 sec1.5 sec
FAULTSOPERATOR
DSP ARM CONTROLLER
OFF
EXIT LOOP
16MIN
16MIN
3
1
14 12
9
7 3
1
14 12
9
7
UL S
ENSO
R 10
KUL
SEN
SOR
N.C.
MOD
E A
MOD
E B
PROGRAM
MOTOR 1INPUTS
[+ ][-]
[+ ][-]
MOTOR 2INPUTS
MAXIMUM CONTROLSDSP ARM CONTROLLER
Battery Back-Up ModeLEAVE OPEN - After a power failure, gate will continue to operate until battery power is drained. At this point, the next open command, gate will remain OPEN. Gate will automatically close after AC power is restored if close timer is ON.
LEAVE CLOSED - After a power failure, gate will continue to operate until battery power is drained. At this point, gate will remain CLOSED.
OPEN 1 TIME - After a power failure, gate automatically OPENS and REMAINS OPEN. When power is restored, gate will automatically close.
Maglock DelayTurned OFF - NO Maglock installed.
Set to 1.5 sec or 2.5 sec - You MUST select a time delay when using a maglock. Maglock power disengages 1.5 sec or 2.5 sec before gate starts opening.Dual Gate Operators using Maglock: Primary gate opens FIRST. Install maglock accordingly to account for this.
MAGLOCK LED (Monitors Maglock):ON - LockedOFF - UnlockedFlashing - Problem with Maglock Power.
Operator SwitchSINGLE - Single operator installed (Motor 1).DUAL - Dual operators installed
(Motor 1 & Motor 2).
Close Timer1st click clockwise - Knob at MIN: 1/2 sec... 2nd click clockwise: 1 sec... 3rd click: 4 sec...4th click: 8 sec... etc up to 60 sec. MAX.LED turns ON for MAX setting ONLY
obd
port
ODB Port Black Box1. Plug MAX USB flash drive into OBD port on circuit board.
OBD LED will flash while file is downloading. Remove flashdrive after LED stops flashing (up to 5 minutes to download).
2. Plug flash drive into anycomputer USB port ORsmart phone using a USBphone adapter. The mostrecent 8000 events can be viewed.No special software required.
USB Phone
Adapter
Required
OR
Computer
Smart Phoneo
bdpo
rtMAX Flash Drive
DIP-Switches
Closing Gate SpeedAfter gate positions have been “Learned”, the gate will cycle at the speed set on “CLOSING GATE SPEED” settings.
Typically set to MAX, LEDs ON.
MOTOR 2MOTOR 1
CLOSING GATE SPEEDMIN MINMINMINMINMIMM MINMINMINMIMM
MA MX AXMOTION CONTROL
OPEN STOP CLOSE
JOG
OPEN CLOSE
Programming Assistant Buttons
NextBack Up Down
Anti-TailgateTurned OFF - Close timer will close the gate at its selected time.Turned ON - (In-ground loops required) Gate will close after all the in-ground loops have been cleared no matter how long the close timer is set for. When an in-ground safety loop gets activated during the close cycle, gate will PAUSE and NOT reopen. When loop is cleared, gate will continue to close preventing UNAUTHORIZED entry.
Solar ModeTurned OFF - AC input Power ONLY.Turned ON - Solar panels installed. Unit draws min power to extend battery life.
Program Button
PROGRAM INSTRUCTIONS ARE ON SCREEN
ERD SENSITIVITY
MIN16
3
1
14 12
9
7
MA XSENSE
ERD SENSITIVITY
MIN16
3
1
14 12
9
7
A. Turn knob until blue LED lights up.Maximum sensitivity reached,Position 1 - Too sensitive for most gates.
B. Turn knob counter-clockwise toreduce gate sensitivity while testingERD until desired results is attained.(LED remains OFF for all but position 1)
NOTE: Cycle the gate 3 or 4 times to make sure that the ERD sensor does not falsely trigger.
• 16 sensitivity setting positions for EACH direction.• NO mechanical hard stops for knobs.
16N
16N
16IN
1MINMINMINMINMIN
1
If alarm sounds while adjusting ERD, press STOP BUTTON to shut-off alarm.
IMPORTANT: Adjust the ERD to avoid injury as well as to minimize vehicle damage.
MOTION CONTRO L
OPEN STOP CLOS E
ERD Sensitivity Setting
MA XSENSE
2. LEDs WILL turn ON for each detected “UNLEARNED” sensor thathas been wired to the inputs. If a sensor’s LED is NOT on, thatsensor has a problem and it MUST be corrected beforecontinuing.
Possible problems:• Photocells are out of alignment• Photocells are wired wrong - N.C. or N.O. depending on
which photocells are used.• Sensor is bad
When all LEDs are ON that should be ON, proceed to next step.
3. Press STOP button again within 5 min. to learn sensors and end learn mode,beeping stops. Wired “Unlearned” Inputs will now be MONITORED.
NOTE: If STOP button is not pressed within 5 min., learn mode terminates.If no “UNLEARNED” sensors are detected then factory default setting isrestored (Inputs will NOT be Monitored).
MOTION CONTRO L
OPEN STOP CLOSE
MOTION CONTRO L
OPEN STOP CLOSE
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN/CLS NC
GN D
12VDC OU T
GN D
PHOTO CLS 10K
OPEN/CLS 10K
12VDC OU T
UL S
ENSO
R N.
C.UL
SEN
SOR
10K
O
R N.
C. O
R N.
C. O
R N.
C. O
R N.
C. O
N.C.
N.C.
N.C.
N.C..C
SENS
OR
SENS
OSE
NSO
SENS
OSE
NSO
ENSO
ENS
ENSNS
O
R10
K
O
R 10
K
O
R 10
K
O
R 10
K
O10K
10K
10101
H
NSOR
RRRRR111
SOR
H
RRRRRR1
SO PHORRRRRRRR
SO PPOORRRRRRR
SO PPO POORRRRRR
SO PPO POOORRRR
SO PPO PO POOORR
O PPO POOOOOOOO
O
L SEN
NNSSSS
PS PS PSO PSOO
O
L SEN
NNNSSSSS
PS PSL S
ENNNNNSSSSSS
L SEN
NNNNNSSSSL S
EENNNNNNSSS
SEENNNNNNN
SEEENNNNN
SEEEENNN
SEEEE
1. Press and HOLD the STOP button & then the OPEN button togetheruntil beeping is heard, learn mode begins. DO NOT press the OPENbutton before the STOP button or learn mode will NOT begin (no beeping).
MONITORED UL sensors Input
“Unlearned” input Factory learned “Unlearned” input
“Unlearned” input “Unlearned” input “Unlearned” input
7AFUSE
POWER115VAC3A ma x
115V AC3A ma x
On
Of f
WARNING: For continued protection against fire, replace only with the
same type and rating of fuse.
AV ERTISSEMENT : pour ne pas compromettre la protection contre les risques d’incendie, utiliser un
fusible de mêmes type et caractéristiques nominales.
Select Input Vo ltage115VAC or 230V AC
(AC)
POWER IN
115V
MAX Toroid Box
Turn off ALL PowerIMPORTANT: This procedure must be followed whenever ALL power must be turned OFF on operator.
ON/OFFBATTERY
1 Turn OFF POWER Switch on MAX Toroid Box.Battery power will remain ON.
2 Press and HOLD the RED ON/OFFBATTERY button until beep is heard,then release button.
Closed Gate
OpenOpen
INSIDEProperty
OUTSIDEProperty
PULL OPEN
PUSH OPEN
Wall
Gate Opening Direction
Minimum of ONE Entrapment protection sensor MUST be installed or operator will NOT function.It MUST be MONITORED and NORMALLY CLOSED (N.C.)/10K.All entrapment zones should be protected by MONITORED sensors.
UL 325 2018 Standard
JO G
OPEN CLOSE
Push and HOLD to Open or Close (release button to stop gate). Helps when “Fine tuning” gate limit positions.
Jog Buttons
MOTOR 1
MOTOR 2
LIMIT 1LIMIT 2LIMIT 1LIMIT 2
Sensor Learn Mode:
POWER Switch
A sensor wired to the PHOTO CLS NC will “AUTOMATICALLY be MONITORED”(Factory default). All other inputs MUST be learned before they will be monitored.
DSP Arm Overview-Rev 7
Reserved
Battery Beep Mode
2
3
4
5
6
7
8
9
10
Gate in Motion Alert
Strobe Light Relay Control
Quick-Close
Solenoid Control Relay
Stop Input Polarity
Open Relay Polarity
UL Closing Photo ONPHOTO CLS NC
Anti-tailgate
OFF
OFFON
OFFON
OFFON
OFFON
OFF
ON
OFFON
ON1
3
4&5
6
Open Relay Pulsed1
2
MOD
E B
Switc
hes
MOD
E A
Switc
hes
Short Gate < 7 FT - shorter ramp downLong Gate > 10 FT - longer ramp down
Gate < 7 FT7 FT < Gate < 10 ft10 FT < Gate < 13 ftGate > 13 FT
MAX Super armMAX Arm
SecondaryOpposite Direction
Lock on Close
Choose ActuatorType
Select GateLength
OFFON
OFFON
OFFON
OFFON
5-OFF 4-OFF5-OFF 4-ON5-ON 4-OFF5-ON 4-ON
REQUIRED SETTING
Open Relay ON when gate openOpen Relay Pulsed when gate openSecondary moves same as primarySecondary moves opposite of primaryStop at close limit switch (see page 33)Stop on overload condition after seeing close limit switch
No beeping when ONLY battery power and gateis in motion.Beeping when ONLY battery power and gate isin motion.No alarm while gate in motionAlarm while gate in motionTamper Relay NO/C Triggered while gate in motionfor strobe light control.No quick-closeQuick-close ON
Stop Input NO-connect to GND to activateStop Input NC-disconnect from GND to activateOpen Relay CLOSED when gate is openOpen relay OPEN when gate is open
UL Closing Photo anti-tailgate OFF
UL Closing Photo anti-tailgate ON
MUST be OFFDO NOT turn ON
ON
No Close Tamper Detect Trigger Tamper Relay (alarm for slider only)Close Tamper Detect OFF
ON
OFF
ON
For Maglock: Mag lock relay will trigger BEFOREclosed limit is reachedFor Solenoid: Mag lock relay will trigger AFTERclosed limit is reached
•••••
To enter PROGRAM mode, press and hold PROGRAM button for 5 seconds. Follow instructions on-screen using the 4 buttons shown at left to program with. Press ONLY PROGRAM button again to end programming when finished.
In PROGRAM mode, you can do the following:
•
Scroll through most recent errors.View input voltage (DC voltage).View average current gate consumption.View cycle count.Program date and time.Turn on/off other advanced features.
www.max.us.com
DSP Arm Controller Control Box WIRING OverviewMaximum Controls LLC.10530 Lawson River Ave
Fountain Valley, Ca 92708Tel: (949) 699-0220
EXIT PWR
ALARM
POWER /SOLAR IN
BATTERYINPUT
OPENING CLOSING
MOTOR 2MOTOR 1
ERD
OBD PORTBLACK BOX
PROGRAMMING
SOLAR MODE
MOTOROVERLOAD
ERD
MOTOROVERLOAD MIN MAX
OFF
MAXSENSE
MAXSENSE
BATTERYBACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
CLOSING GATE SPEED
MOTOR 2LIMITS
MAGLOCK
ULENTRAP
STOP CLOSE
CLOSETIMER
MAGLOCKDELAY
JOG
BATTERYTEST
BATTERY
INPUTERROR
BATTERYIN USE
POWER
REPLACEBATTERY
LEAVECLOSED
LEAVEOPEN
OPEN1 TIME
BATTERY VOLTAGEE F1/2
RESET
IDPLUG
MODULEPORT
GATE OPEN
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NCOPEN / CLS NC
GND12VDC OUT
GND
GND
GND
GND
GND
JOG
CLOS
EJO
G OP
EN
TAMP
ER IN
TAMP
ER N
O
GATE
DISA
BLE
KEYP
AD/C
ARD
GND
GND
MAX
OPEN
FIRE
DEP
T
RADI
O GN
DRA
DIO
SIGN
AL
STRI
KE
CLOS
ECO
M
COM
STOP
OPEN
PHOTO CLS 10KOPEN / CLS 10K
12VDC OUT
NOCOM
NC
COMGATE CLOSED
LIMIT 1GND
LIMIT 2
MOTOR 1LIMITS
MOTOR 1
MOTOR 2
LIMIT 1GND
LIMIT 2
LIMIT 1LIMIT 2LIMIT 1LIMIT 2
ID PLUGERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOPLOOP PWR
LOOP
CENTER
SAFETY
OFF
SINGLE
OPEN
ON/OFFBATTERY
CLOSE
DUAL
ON
ANTI-TAILGATE
PUSHOPEN
PULLOPEN
GATEOFF
123456789
10OFF
123456
MIN MIN
MAX MAX
ON
OFF 2.5 sec1.5 sec
FAULTSOPERATOR
DSP ARM CONTROLLER
OFF
EXIT LOOP
16MIN
16MIN
3
1
14 12
9
7 3
1
14 12
9
7
UL S
ENSO
R 10
KUL
SEN
SOR
N.C.
MODE
AMO
DE B
PROGRAM
MOTOR 1INPUTS
[+][-]
[+][-]
MOTOR 2INPUTS
MAXIMUM CONTROLSDSP ARM CONTROLLER
AC Power Input
BatteriesTwo 12VDC
Batteries-7Ahr
(located on side of control box)Jog Gate Open/Close
SAFETYCENTEREXIT
J3
J2
J4 J5
In-GroundLoops
Factory Wired
Loop Detector Rack
Safety loops wired in series.
CenterLoop
SafetyLoop
SafetyLoopExitLoop
Plug-In Loop DetectorsCard Reader
Separate power fordevices if required.KeypadKey Switch
Telephone Entry
Emergency OPEN(Overrides gatedisable switch)
MAX OPEN(Overrides gatedisable switch)
Dry Contact NO
Dry Contact NO
NO
NO
Radio Signal
Radio SignalRadio Gnd
250 mA Max.
4-WireRadio
3-WireRadio
Stop
StopClose
Open
Tamper NO
Tamper IN
Com
Com
Com
Gate Disable
Com
Gnd
Gnd
Gnd
Gnd
Gnd
Gnd
NC
12 VDC OUT Monitored
Power
Power
NC
Jog CloseJog Open
External AlarmReset ButtonDry Contact
PRESS
to RESET
ID PlugSpecific for operator
model REQUIRED.
MAX
ACTU
ATOR
ARM
Motion Sensor
SecurityCamera
Gate Disable SwitchON
OFF
SirenWarning
Light
PowerPower
ExistingBuildingAlarm
System
Timer
Normally Closed Photocells
Closing Direction
Opening Direction
Closing Direction10K
SensingEdges
- Gnd+
Solenoid LockMaglock NO
Bi-parting gates using locks: Primary gate opens FIRST. Install lock accordingly to account for this.- +
-+
Opening Direction
3
Pow
er
Pow
er
IMPORTANT: NC MONITORED sensors MUST be powered by the 12VDC OUT on the UL Sensor N.C.
IMPORTANT: Photocells MUST be in alignment or fault will occur.
GATE OPEN
GATE CLOSED
Gate StatusMonitoring Device
ONE entrapment protectionsensor MUST be installedor operator will NOT function.
EDILoop Detector
ON
12
34
56
78
5 = Optimum Sens.
= Increase Sens.
= Decrease Sens.
DEFLECTOMETER
POWERON = Normal Power
OFF= No Power
LED INDICATORSDETECTON = DetectOFF= No Detect
2 Hz Flash=Delay Timing
SW1 SW2 Frequency
ON ON = Low
ON OFF = Medium-Low
OFF ON = Medium-High
OFF OFF = HighSW4 SW5 Output B
ON ON = Pulse on Entry
ON OFF = B same as A
OFF ON = Pulse on Exit
OFF OFF = Loop Fault
SW3ON = Fail Secure
OFF = Fail Safe
SW6ON = 2 Second Delay
OFF = No Delay
SW7ON = Normal Presence
OFF = Infinite Presence
SW8ON = Sensitivity Boost
OFF = No Sensitivity Boost
Loop Fault1 Flash = Open Loop
2 Flashes= Shorted Loop
3 Flashes=25% change
of Inductance
Both LED’s Flashing=
Current Loop Fault
PWR LED Flashing=
Previous Loop Fault
EDITel: 480.968.6407
DEFLECTOMETER
SENS
RESET
POWER
DETECTEDI
SENSLMA1800
OPTIONS
12
34
56
78
ON
EDILoop Detector
Low CurrentDraw
OPTIONS
ON
12
34
56
78
5 = Optimum Sens.
= Increase Sens.
= Decrease Sens.
DEFLECTOMETER
POWERON = Normal Power
OFF= No Power
LED INDICATORSDETECTON = DetectOFF= No Detect
2 Hz Flash=Delay Timing
SW1 SW2 Frequency
ON ON = Low
ON OFF = Medium-Low
OFF ON = Medium-High
OFF OFF = HighSW4 SW5 Output B
ON ON = Pulse on Entry
ON OFF = B same as A
OFF ON = Pulse on Exit
OFF OFF = Loop Fault
SW3ON = Fail Secure
OFF = Fail Safe
SW6ON = 2 Second Delay
OFF = No Delay
SW7ON = Normal Presence
OFF = Infinite Presence
SW8ON = Sensitivity Boost
OFF = No Sensitivity Boost
Loop Fault1 Flash = Open Loop
2 Flashes= Shorted Loop
3 Flashes=25% change
of Inductance
Both LED’s Flashing=
Current Loop Fault
PWR LED Flashing=
Previous Loop Fault
EDITel: 480.968.6407
DEFLECTOMETER
SENS
RESET
POWER
DETECTEDI
SENSLMA1800-LP
12
34
56
78
ON
3-Button Control StationDry Contact
External
Loop
Detector
External LoopDetectors
Wire directly to7-PIN terminal
7AFUSE
POWER115VAC3A max
115VAC3A max
On
Off
WARNING: For continued protection against fire, replace only with the
same type and rating of fuse.
AVERTISSEMENT: pour ne pas compromettre la protection contre les risques d’incendie, utiliser un
fusible de mêmes type et caractéristiques nominales.
Select Input Voltage115VAC or 230VAC
(AC)
POWER IN
115V
DANGERHIGH VOLTAGE!
Line (Black)
Neutral (White)
Chassis (Green)
Line (Black)
Neutral (White)
Chassis (Green)
Power Terminal
Chassis Ground(located at the bottomof the inside back panelof the control box)
Choose:Single Phase 115VAC
ORSingle Phase 230VAC
CAUTION: If input AC power selector switch is set for 115V but input power is actually 230 V, 7 Amp Fuse will blow.
MAX Toroid Box(located inside of control box)
Proper Ground
Reset Alarm(located on side of control box)
Alarm
12
45
12
354
WhiteYellow
RedBlackGreen
MAX Super Arm 2300
MAX Arm
Motor 2 connects the same as Motor 1 for EACH model of operator.(Bi-Parting Gates ONLY)
Motor 1
Motor 1
Proper grounding of control box is required for LIGHTNING PROTECTION in lightning prone areas. Minimum 12 AWG, 600 volt insulated wire to a proper ground point within 10 feet of the control box.
GroundingRod
NOTES:DO NOT select the PULSED outputoption for Loop Detectors.
DO NOT set Loop Detectors toHIGH sensitivity to avoid false trigger.
115 OR230VAC
Single PhaseInput Power
Wire
12 VDCOR
24 VDCRadioPower 12
V Po
wer
Stand-Alone Keypadless than 200 mA