dse_5210-5220_us_web[1] farhad
TRANSCRIPT
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
1/26
DSECONTROL
MONITORING
WITHINTELLIGENCE.
DSE5210&DSE5220
AUTO
START&AUTOMAINSFAILURECONTROLMODULES
DSE5210DSE5220
BothmodulesincludeRS232orRS485communicationscapabilitiesforlinkingto
aPC,sendingSMSmessagesandinterfacingwithnewandexistingbuildingmanagement
systems.
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
2/26
FEATURES
Automaticstart
Automaticmains(utility)failuredetection(DSE5220only)Automaticloadtransfer
ConfigurableinputsConfigurableoutputsConfigurablealarms&timersDigitalinputs
AnalogueinputsBack-litcharacterLCDdisplayEngineprotectionFrontpanelmountingPCconfigurableFrontpanelprogrammingRemotemonitoring
RS232or
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
3/26
RS485remotecommunications(tobespecifiedon
ordering)ModbusRTUEnginehistoryeventlogLEDalarm
indicationLCDalarmindicationSMSmessagingHidtilllitalarm
iconsEngineexercisemodeMagneticpick-upTheDSE5210isanAutomaticStartControlModuledesignedtoautomaticallystartandstopdieselandgas
generatingsetsthat
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
4/26
includenonelectronicengines.Themodulealso
providesexcellentenginemonitoringandprotectionfeatures.
Themodulehas
theabilitytomonitorunderspeed,overspeed,chargefailure,emergencystop,low
oilpressure,highenginetemperature,failtostart,failtostop,under/overgeneratorvolts,overcurrent,under/overgeneratorfrequency,low/highDCbatteryvolts,lowfuel
alarmandloss
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
5/26
ofthespeedsensingsignal.Themodule
displaysfaultconditionsontheLCDdisplayandviatheLEDindicators
onthefront.
TheDSE5220isanAutomaticMainsFailureControl
ModuleandincludesallthefeaturesoftheDSE5210plustheabilitytomonitoramains(utility)supply.
Upondetectionofamains
(utility)failurethe
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
6/26
moduleautomaticallystartsthegeneratingset.Once
themains(utility)powerhasbeenrestoreditinstructsthegeneratingset
tostop.
BENEFITS
Fullintegrationintonewand
existingbuildingmanagementsystemsIn-builtenginediagnosticsremovestherequirementforserviceequipmentLicensefreePCsoftwareModuleshelptoimprovethe
lifecycleof
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
7/26
enginestartermotorsOn-sitemoduleconfiguration
tomatchuserrequirementsRemotemoduleconfigurationusingPCsoftware
ModulessendSMSmessagestoengineerstonotifyspecificengineproblems(GSMModem
andSIMCardrequired)User-friendlyset-upandbuttonlayoutOPERATION
ThemodulesareoperatedusingthefrontSTOP,AUTOandMANUALpush
buttons.TheDSE5220
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
8/26
alsoincludesaTESTbutton.Anadditional
pushbuttonallowstheusertoscrollthroughtheLCDdisplayto
viewtheinstrumentationandeventlog.
CONFIGURATION
Themodules
canbeconfiguredusingthefrontpanelbuttonsorbyusingtheDSE810interfaceandPCsoftware.
SPECIFICATIONDCSUPPLY
8
Vto35
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
9/26
Vcontinuous
CRANKINGDROPOUTS
Abletosurvive0Vfor50mS,providingthesupplywasat
least10Vbeforedropoutandsupplyrecoversto5V
STARTRELAY
OUTPUT
16ADCsupplyatsupplyvoltage
FUELRELAYOUTPUT
16ADCatsupplyvoltage
AUXILIARYRELAY
OUTPUTS
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
10/26
5ADCatsupplyvoltage
CHARGEFAIL/EXCITATIONRANGE
0Vto35V
MAXIMUMOPERATING
CURRENT
320mAat12V,215mAat24V
MAXIMUMSTANDBY
CURRENT
175mAat12V,95mAat24V
ALTERNATORINPUTRANGE
15V(L-N)to333VAC(L-N)absolutemaximum
ALTERNATORINPUT
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
11/26
FREQUENCY
50-60Hzatrated
enginespeed(Minimum:15VACL-N)
MAGNETICPICK-UPVOLTAGEINPUT
RANGE
+/-0.5Vto70VPeak
MAGNETICINPUTFREQUENCY
10,000Hz(max)atratedenginespeed
MAINS(UTILITY)SENSINGINPUTRANGE
(DSE5220only)15V(L-N)to333VAC(L-N)
absolutemaximum
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
12/26
MAINS(UTILITY)SENSINGINPUTFREQUENCY
(DSE5220only)50-60Hz
MAINS(UTILITY)&GENERATORLOADING
RELAYOUTPUT(DSE5220only)8AAC250V
MODULEDIMENSIONS(WxH)
240mmx172mm9.4x6.8
PANELCUT-OUT(WxH)
220mmx160mm8.7x6.3
MAXIMUMPANELTHICKNESS
8mm
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
13/26
0.3
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
14/26
ELECTROMAGNETICCAPABILITYBSEN61000-6-2EMCGenericEmissionStandardfortheIndustrialEnvironmentBSEN61000-6-4EMCGenericEmissionStandardfortheIndustrialEnvironmentELECTRICALSAFETYBSEN60950SafetyofInformationTechnologyEquipment,includingElectricalBusinessEquipmentTEMPERATUREBSEN60068-2-2TestAbto+70oC60067-2-2HotTestAbto-30oC60068-2-1ColdVIBRATIONBSEN60068-2-6Tensweepsineachofthreemajoraxes5Hzto8Hz@+/-7.5mm,[email protected]
c93%RH@40oCfor48hoursSHOCKBSEN60068-2-27Threeshocksineachofthreemajoraxes15gnin11mSENVIRONMENTALTESTINGSTANDARDSELECTROMAGNETICCAPABILITYBSEN61000-6-2EMCGenericEmissionStandardfortheIndustrialEnvironmentBSEN61000-6-4EMCGenericEmissionStandardfortheIndustrialEnvironmentELECTRICALSAFETYBSEN60950SafetyofInformationTechnologyEquipment,includingElectricalBusinessEquipmentTEMPERATUREBSEN60068-2-2TestAbto+70oC60067-2-2HotTestAbto-30oC60068-2-1ColdVIBRATIONBSEN60068-2-6Tensweepsineachofthreemajoraxes5Hzto8Hz@+/-7.5mm,[email protected]%RH@40oCfor48hoursSHOCKBSEN60068-2-27Threeshocksineachofthreemajoraxes15gnin11mSENVIRONMENTALTESTINGSTANDARDSLEDINDICATION
Hidtillliticonsareusedtoshowthepresenceof
alarmconditionsdetectedbythemodules.TheiconsappeartotheleftoftheLCDdisplay.
TELEMETRY
Themodulegivesthe
userfulltelemetry
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
15/26
facilitieswhenusingtheoptionalcommunicationssoftware.
ThemodulecanbeconnectedtoaPCusingtheDSE810PC
interfaceorbyusingasuitablemodem.ThePCsoftwareisMicrosoftWindows
based.
Allaccessintothemodulecanbeconfiguredtobepasswordprotectedtopreventunauthorisedentry.ThePCsoftwareallowsthemodule
tobecontrolled
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
16/26
fromaremotelocation.
INPUTS
&OUTPUTS
Analogueinputsareprovidedforoilpressure,engine
temperatureandfuellevel.Theseconnecttoconventionalenginemountedresistivesenderunits
toprovideaccuratemonitoringandprotectionfacilities.Theycanalsobeconfiguredtointerfacewithdigitalswitchtypeinputsforlowoilpressureandhigh
enginetemperatureshutdowns.
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
17/26
Relayoutputsareprovidedfor
fuelsolenoidoutputandthreeconfigurableoutputs.Theconfigurablerelayfunctionscan
beselectedfromarangeofdifferentfunctions,conditionsoralarms.Therelays
supplypositiveplantsupplyout.
INSTRUMENTATION
Themodulesprovideadvancedmeteringfacilities,displayingtheinformationontheLCDdisplay.Theinformation
canbeaccessed
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
18/26
usingthedisplayscrollpushbuttonslocated
nexttotheLCDdisplay.
52105220GeneratorVoltsL1N,L2N,L3NGeneratorVoltsL1L2,L2L3,L3L1GeneratorAmpsL1,L2,L3GeneratorFrequencyHzEngineSpeedRPMEngineOilPressureFuelLevel%EngineTemperaturePlantBatteryVoltsEngineHoursRunGeneratorkVAGeneratorkWGeneratorCos.GeneratorVoltsL1N,L2N,L3NGeneratorVoltsL1L2,L2L3,L3L1GeneratorAmpsL1,L2,L3GeneratorFrequencyHzEngineSpeedRPMEngineOilPressureFuelLevel%
EngineTemperaturePlantBatteryVoltsEngineHoursRunGeneratorkVAGeneratorkWGeneratorCos.MainsVoltsL1N,L2N,L3NMainsVoltsL1L2,L2L3,L3L1MainsFrequencyHzRELATEDMATERIALSTITLEPARTNOSDSE5210InstallationInstructions053-023DSE5220Installation
Instructions053-020DSE5210Manual057-011DSE5220Manual057-012DSE157DataSheet055-045DSE545&DSE548DataSheet055-04952/53xxSoftwareManual057-006
COMMUNICATIONS
The
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
19/26
DSE5210&DSE5220haveanumberof
differentcommunicationcapabilities.
SMSMessaging
Whenthemodule
detectsanalarmcondition,ithastheabilitytosendanSMSmessage
toadedicatedmobilenumber,notifyinganengineeroftheproblem.(GSMModemandSIMCardrequired)
RemoteCommunications
Whenthe
moduledetectsan
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
20/26
alarmcondition,itdialsouttoa
PCviaamodemnotifyingtheuseroftheexactalarmcondition.
BuildingManagement
Themodulehasbeendesignedtobe
integratedintonewandexistingbuildingmanagementsystems.
PCSoftware
Themodulehastheabilitytobecontrolled,configuredandmonitored
fromaremote
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
21/26
PC,usingtheDSE810interface.
EVENTLOG
Themoduleincludesacomprehensiveeventlogthat
showsthe30mostrecentalarmconditionsandthedateandtimethat
theyoccurred.Thisfunctionassiststheuserwhenfaultfindingandmaintainingageneratingset.
EXPANSIONMODULES
DSE157OutputRelayExpansion
ModuleDSE545&
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
22/26
DSE548RemoteAnnunciationExpansionModule
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
23/26
DSE5210&DSE5220
2AMPFUSESMG2AMPFUSESBATTERY-VE+VEFUELEMERGENCYSTOPLOWOILPRESSUREHIGHCOOLANTTEMPFUELLEVELSENDERUSERCONFIGURABLE-VEINPUT1USERCONFIGURABLE-VEINPUT2USERCONFIGURABLE-VEINPUT3USERCONFIGURABLE-VEINPUT4USERCONFIGURABLE-VEINPUT5USERCONFIGURABLE-VEINPUT6USERCONFIGURABLE+VEINPUTUSERCONFIGURABLE+VEINPUTUSERCONFIGURABLE+VEINPUTUPTO32AMPSFUSEMIN2AMPMAX20AMPANIT-SURGEFUSEBATTERYFUELFUELWLCRANKCHARGEALTCRANKCHGALTOILWATERSENDERCOMMONIMPUTSPLANT+VEMAINSLOADINGRELAYGENERATORLOADINGRELAYOUTPUTSOUTPUTSMAINSVOLTSGENVOLTSGENCURRENTELECTRICALINTERLOCKMECHANICALINTERLOCKLOADMODLE5210/5220BATTERYNEGATIVEMUSTBEGROUNDEDTERMINALSSUITABLEFOR22-16AWG(0.6mm-1.3mm)FIELDWIRINGTIGHTENINGTORQUE=0.8Nm(7lb-in)
NOTE1THESEGROUNDCONNECTIONSMUSTBEONTHEENGINEBLOCK,ANDMUSTBETOTHESENDERBODIES.THEGROUNDWIRETOTERMINAL47MUSTNOTBEUSEDTOPROVIDEAGROUNDCONNECTIONTOANYOTHERDEVICETIGHTENINGTORQUE=0.8Nm(7lb-in)P810157NOTE1CT1CT2CT3COM3940414235363738293027283132333416171812345944454647101112131415678L1L2L3NL1L2L3NCTsMUSTBE5AMPSECONDARY1P2S1S2MPUL1L3NL2L1L3NL2FROMMAINSFROMGENERATORDSE5220ONLY
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
24/26
DEEPSEAELECTRONICSPLC
HighfieldHouseHunmanbyIndustrialEstateHunmanby,NorthYorkshireYO140PHEngland
RegisteredinEngland&WalesNo.01319649
DEEPSEAELECTRONICSINC
3230WilliamsAvenueRockfordIL61101-2668USA
TELEPHONE
+44(0)1723890099
FACSIMILE
+44(0)1723893303
VAT
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
25/26
No.316923457
TELEPHONE
+1
(815)3168706
FACSIMILE
+1(815)3168708
EMAIL
WEBSITE
www.deepseaplc.com
EMAIL
WEBSITE
www.deepseausa.com
-
8/9/2019 DSE_5210-5220_US_WEB[1] FARHAD
26/26