dsc in florida & puerto rico jaime echeverri territory sales manager (s. florida) mark buckley...
TRANSCRIPT
DSC in Florida & Puerto Rico
Jaime Echeverri Territory Sales
Manager(S. Florida)
Mark Buckley Technical Sales Trainer
Gerardo Murillo Territory Sales
Manager(N.Florida)
Tyco InternationalFocus: Vital Products and Services
100K+ employees, 60 Countries
Unified Group of World-Leading Access Control, Video, and Intrusion Brands
Tyco Security SolutionsFocus: Industry Leading Security Products, Services and Solutions
64K+ employees
Vision Be the best provider of
electronic security products and solutions worldwide.
Mission Deliver innovative products,
solutions and services that are our customers'
preferred choice.
Beliefs Customer Focus l Quality l Creativity l IntegrityPeople Development, Diversity & Inclusion, Boundary less Teamwork, Courage & Curiosity, Continuous Improvement
AGENDA
Trends & Technologies POTS & Alternate Communications
DSC IP & GSM ProductsNEW IMPASSA - SCW9057
1 in 7 are Wireless
Only
Wireless Households
ExampleAt Age 38, Number of
Wireless Only Households Quadrupled in
five years
Age Trend
Change In The PSTN
The life span of a Central Office Switch is 30 years.
Average age of Central Office Switch is 20 years.
No replacement parts available.
Soft switch overlays being implemented today.
Soft switch’s are more efficient.
Cellular Technologies
Used for Primary and Backup Communications.
Drop in solution for landline replacement.
Now available as an option to virtually all monitoring scenarios.
- Residential- Commercial- Fire (Sole Path & Backup per UL 864)- Event Monitoring
PSTN vs. GPRS/IPWhat technology should you go for?
Phone lines are NOT supervised
GPRS & IP Communicators are at a minimum rate of 10 seconds.
Phone communication is 20 - 30 secondsGPRS & IP are two seconds MAX!
Phone line is without encryptionGPRS & T-Link modules are
Panel download over phone line is 20-25 minutesGPRS & IP take approx. 1 - 4 minutes
DSC GPRS or IP Modules will communicate directly to a monitoring Central StationNo Clearance house
DSC SIA DC 10 IP Protocol has been already implemented by ELK , Alarm.com
Sur-Gard receivers can receive thousands of simultaneous IP signals without drops.
DSC IP/GPRS Technology
TL250/300
TL260/65
TL150
TL260GS/65
GS3060
GS3055-ICF
Used for Supervised communicating paths.
Used for Primary and Backup Communications.
Used for Remote panel programming using DLS.
Drop in solution for landline replacement.
Now available as an option to virtually all monitoring scenarios.
- Residential- Commercial- Fire (Sole Path & Backup per UL 864)- Event Monitoring
All these Modules Are:
Panel Specific IP Communicator
TL265GS
TL265
GS2065
Alexor
TL150 *
TL260GS
TL260
GS2060
TL250 **
Power Series
Impassa
3G2055
TL255
TL2553G
TL150 TL250 TL300 TL255 TL260* TL265* TL2553G
PC5010 V2.0 þ þ
PC5020 V3.2+ þ þ
PC4020 V3.31+ þ
PC1616/1832/1864 V4.1+ þ þ þ
SCW9047
(Alexor) PC9155 þ
(IMPASSA) SCW9057
SIA Format þ þ þ þ þ þ
CID Format þ þ þ þ þ
Keybus Connect þ
PC-Link Connect þ þ þ þ þ
Zone Inputs þ þ
DLS2002 ó IP þ
DLS IV ó IP/SMS þ þ þ þ þ
TLink Console þ þ
Connect 24 þ
GS3055-ICF Overview
The GS3055-ICF CF is:1. A universal wireless alarm communicator that can be used as
a backup or sole communicator 2. A device which connects the alarm control panel to the GSM
network and reports alarm signals directly to a monitoring central station receiver (Sur-Gard System III with a DRL3-IP line card or System II or System I)
3. A digital transmitter which provides full reporting from any control panel that communicates using Contact ID format
GS3055-ICF Overview
The GS3055-ICF Listings
UL864UOXX_S4019 - Control Unit Accessories, System
CSFM pursuant to Section 13144.1Listing Number 7300-1273:134
NFPA72 2010 Edition
GS3055-ICF Overview
The GS3055-ICF ListingsThe GS3055-ICF is compliant with the latest requirements for Communications Methods as per UL864 and NFPA72 2010 Edition. It can be used in Fire Monitoring applications as a single communications technology, in which case any failure of the communications path shall be annunciated at the supervising station within 5 minutes of the failure, or it can be used as part of a multiple communications technologies (for example in conjunction with a DACT). When used as a back-up provision shall be made to monitor the integrity of each communication path and failure of any communications path shall be annunciated at the supervising station and at the protected premises within not more than 24 hours of the failure.
The GS3055-ICF has also been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of theCalifornia Health and Safety Code.
GS3055-ICF Features
Features:• When used as a sole communicator the GS3055-ICF will use
the 4 MB rate plan available from Connect 24. (please contact Connect 24 for Pricing)
• Compatible with any control panel capable of communicating using the Contact ID format
• Simulates telephone line • Uses GPRS data channel for high-speed, reliable, and low cost
communications to an IP receiver• 4 on-board inputs• 4 on-board outputs (open collector)• Compatible with Sur-Gard System I, System II or System III
monitoring station receivers (Either may be used as sole and/or Backup)
• UL 864, NFPA 2010 and CSFM listed
GS3055-ICF Specifications
Specifications:
Power Supply Ratings
Input Voltage120V/60Hz/0.3A
Battery12V/7Ah
Charging current700mA(max)
Current ConsumptionStandby Current120mATransmitting Current450mAPGM Outputs
4 Open Collector, 50mA
Operating Frequency850/1900MhzAntenna Gain
1.5dBOperating Temperature 0ºC to
49ºC (32ºF to 120ºF)Internal Event Buffer256 Events