Page 1 of 23 Engineering Report 58687-2 Drop Test for Seahorse Protective Equipment Cases Prepared by Nicole T. Duff, Technical Writer Rachel A. Thompson, Associate Test Engineer Approved by David M. Gillen, Senior Program Manager This document shall not be reproduced, except in full, without express written authorization of Element Minneapolis. In the event this document is provided to the customer in any format that may be modified or copied in any part, no modifications, changes, or additions to this report, nor any summary hereof, shall be permitted in any manner. All original content of this document shall be considered one entire report. Element Minneapolis shall not be liable to the customer or to any third party for unauthorized modification or misuse of this document. EAR-controlled data: This document contains technical data whose export and re-export/re-transfer is subject to control by the U.S. Department of Commerce under the Export Administration Act and the Export Administration Regulations. The Department of Commerce’s prior written approval may be required for the export or re-export/re-transfer of such technical data to any foreign person, foreign entity, or foreign organization whether in the United States or abroad. Element Materials Technology Minneapolis LLC (A subsidiary of Element Materials Technology Minneapolis Inc.) 9725 Girard Avenue South Minneapolis, MN 55431 952-888-7795 800-826-3710 www.element.com

Upload: others

Post on 19-Oct-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Drop Test - Seahorse Protective Equipment Cases | USA Made

Page 1 of 23

Engineering Report 58687-2

Drop Test for Seahorse Protective Equipment Cases

Prepared by

Nicole T. Duff, Technical Writer

Rachel A. Thompson, Associate Test Engineer

Approved by

David M. Gillen, Senior Program Manager

This document shall not be reproduced, except in full, without express written authorization of Element Minneapolis.

In the event this document is provided to the customer in any format that may be modified or copied in any part, no

modifications, changes, or additions to this report, nor any summary hereof, shall be permitted in any manner. All original

content of this document shall be considered one entire report. Element Minneapolis shall not be liable to the customer or

to any third party for unauthorized modification or misuse of this document.

EAR-controlled data:

This document contains technical data whose export and re-export/re-transfer is subject to control by the U.S. Department

of Commerce under the Export Administration Act and the Export Administration Regulations. The Department of

Commerce’s prior written approval may be required for the export or re-export/re-transfer of such technical data to any

foreign person, foreign entity, or foreign organization whether in the United States or abroad.

Element Materials Technology Minneapolis LLC (A subsidiary of Element Materials Technology Minneapolis Inc.)

9725 Girard Avenue South Minneapolis, MN 55431 952-888-7795 800-826-3710 www.element.com

Page 2: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 2 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Revision history

Revision Total pages Date Description

-- 23 June 4, 2019 Original

Page 3: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 3 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Prepared for Seahorse Protective Equipment Cases

Attention Flavio Valencia Test number 58687-2

Test start 2/7/2019 Test completion 2/15/2019

PO number 22660 Purchase date 2/12/2019

Drop Test 1.0 Abstract

1.1 Object

Subject three Seahorse Cases to a Drop Test as specified in MIL-STD-3010C, dated August 1, 2013, Method 5007, Level A, as requested in Seahorse Protective Equipment Cases purchase order 22660, dated February 12, 2019.

1.2 Conclusions The expandable handle of test unit UUT-58687-4 ejected several times during testing, the handle was closed after each ejection, and testing continued; the handles of the other test units did not eject during testing. No significant damage to the test units was observed after all twenty-six drops, only minor scuffing and scratching was noted. All three test units functioned properly upon completion of the test.

2.0 Unit(s) tested

Table 2-1: Units tested

Manufacturer Seahorse Protective Equipment Cases

Device Two (2) Seahorse Cases

Model/part number 230 530 SE830

Serial number N/A N/A N/A

Sample identifier UUT-58687-2 UUT-58687-3 UUT-58687-4

The results of this test apply only to the units identified in this Engineering Report by device identifier and model / part number, or serial number.

awalker
Highlight
awalker
Highlight
awalker
Highlight
awalker
Highlight
awalker
Highlight
Page 4: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 4 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

3.0 Test requested Subject three Seahorse Cases to a Drop Test as specified in MIL-STD-3010C, dated August 1, 2013, Method 5007, Level A. The specimen is allowed to drop freely from 36 inches onto each flat face, edge, and corner, for a total of twenty-six drops.

4.0 Instrumentation, procedure performed, and results

4.1 Instrumentation

All instrumentation is calibrated regularly by instruments directly traceable to the National Institute of Standards and Technology, and in accordance with ANSI/NCSL Z540.3-2006, and ISO/IEC 17025: 2005.

Table 4-1: Instrumentation list

Equipment Number Description Manufacturer

Model Number

Last Calibration

Due Calibration Range

503-213 Precision Drop Tester Lansmont PDT-56ED N/A N/A 0 to 48 inches

770-068 Measuring Tape Starrett 530-100 5/22/2018 5/22/2019 0 to 100 feet

4.2 Procedure

Each test unit was tested individually. The first test unit was subjected to twenty-six drops from a height of 36 inches, drops on each flat face, edge, and corner. After each drop, the test unit was visually examined for damage and the test unit functionality was checked. The procedure outlined above was repeated with the remaining test unit.

4.3 Results The expandable handle of test unit UUT-58687-4 ejected several times during testing, the handle was closed after each ejection, and testing continued; the handles of the other test units did not eject during testing. No significant damage to the test units was observed after all twenty-six drops, only minor scuffing and scratching was noted. All three test units functioned properly upon completion of the test. The test units were retained at Element Minneapolis. Test data and photographs are included in the following pages.

awalker
Highlight
awalker
Highlight
Page 5: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 5 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Figure 4-1: Drop Test data sheet

awalker
Highlight
awalker
Highlight
awalker
Highlight
awalker
Highlight
Page 6: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 6 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Photograph 4-1: Test unit identification

Photograph 4-2: Test unit identification

Page 7: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 7 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Photograph 4-3: Representative Overall Drop Test setup

Photograph 4-4: Representative Overall Drop Test setup, side 1

Page 8: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 8 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Photograph 4-5: Representative Overall Drop Test setup, side 2

Photograph 4-6: Representative Overall Drop Test setup, side 3

Page 9: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 9 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Photograph 4-7: Representative Overall Drop Test setup, side 4

Photograph 4-8: Representative Overall Drop Test setup, side 5

Page 10: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 10 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Photograph 4-9: Representative Overall Drop Test setup, side 6

Photograph 4-10: Representative Overall Drop Test setup, side 1-2

Page 11: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 11 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Photograph 4-11: Representative Overall Drop Test setup, side 1-3

Photograph 4-12: Representative Overall Drop Test setup, side 1-4

Page 12: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 12 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Photograph 4-13: Representative Overall Drop Test setup, side 1-5

Photograph 4-14: Representative Overall Drop Test setup, side 2-3

Page 13: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 13 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Photograph 4-15: Representative Overall Drop Test setup, side 3-4

Photograph 4-16: Representative Overall Drop Test setup, side 4-5

Page 14: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 14 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Photograph 4-17: Representative Overall Drop Test setup, side 5-2

Photograph 4-18: Representative Overall Drop Test setup, side 2-6

Page 15: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 15 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Photograph 4-19: Representative Overall Drop Test setup, side 3-6

Photograph 4-20: Representative Overall Drop Test setup, side 4-6

Page 16: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 16 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Photograph 4-21: Representative Overall Drop Test setup, side 5-6

Photograph 4-22: Representative Overall Drop Test setup, side 1-2-3

Page 17: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 17 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Photograph 4-23: Representative Overall Drop Test setup, side 1-3-4

Photograph 4-24: Representative Overall Drop Test setup, side 1-4-5

Page 18: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 18 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Photograph 4-25: Representative Overall Drop Test setup, side 1-5-2

Photograph 4-26: Representative Overall Drop Test setup, side 6-2-3

Page 19: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 19 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Photograph 4-27: Representative Overall Drop Test setup, side 6-3-4

Photograph 4-28: Representative Overall Drop Test setup, side 6-4-5

Page 20: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 20 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Photograph 4-29: Representative Overall Drop Test setup, side 6-5-2

Photograph 4-30: Test unit UUT-58678-3 post-test

Page 21: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 21 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Photograph 4-31: Test unit UUT-58678-2 post-test

Photograph 4-32: Representative of handle being ejected from test unit UUT-58678-4 during testing

Page 22: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 22 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Photograph 4-33: Representative of handle being ejected from test unit UUT-58678-4 during testing

Photograph 4-34: Representative of handle being ejected from test unit UUT-58678-4 during testing

Page 23: Drop Test - Seahorse Protective Equipment Cases | USA Made

Element Minneapolis EAR-Controlled Data Page 23 of 23 Engineering Report No. 58687-2 This document is subject to the controls and restrictions on the cover page

Photograph 4-35: Test unit UUT-58678-4 post-test