drainage strategy report - secure.broadland.gov.uk · drainage strategy report 3097 version 1 3...
TRANSCRIPT
Drainage Strategy Report
Proposed Residential Development
Land Off Woodbastwick Road
Blofield Heath
Client: David Futter Associated Limited
September 2016 – Version 1
Land off Woodbastwick Road, Blofield Heath Drainage Strategy Report
3097 Version 1 i
Document Control Sheet
Project Name: Proposed Residential Development, Land off Woodbastwick Road, Blofield Heath, Norfolk, NR13 4QH
Project Reference: 3097
Report Title: Drainage Strategy Report
Name Position Signature Date
Prepared By: Gillian Hoy Senior Geoenvironmental Engineer
13 September 2016
Approved By: Andy Westby Director
13 September 2016
For and on behalf of Bingham Hall Associates
Disclaimer
The copyright in this report prepared by BHA Consulting Ltd is owned by them and no such report, plan or document may be
reproduced, published or adapted without their written consent. Complete copies of this report may however be made and distributed
by the Client in dealing with matters related to the brief.
The information given in this report is solely for the use of the Client noted above. BHA Consulting Ltd can accept no responsibility or
liability to any third party. The benefit of this report is not transferable to any third party except with the written agreement of the
original Client and of BHA Consulting Ltd. An extra fee will be payable for such a transfer.
Land off Woodbastwick Road, Blofield Heath Drainage Strategy Report
3097 Version 1 ii
Contents
Executive Summary ................................................................................................................ 1
Introduction .................................................................................................................... 3
Site Appraisal ................................................................................................................... 4
Foul & Surface Water Drainage Strategy ............................................................................ 8
Appendices
Appendix A: Site Layout Plan
Appendix B: Greenfield runoff Rates
Appendix C: Drainage Strategy Plan
Appendix D: Drainage Calculations
Land off Woodbastwick Road, Blofield Heath Drainage Strategy Report
3097 Version 1 1
Executive Summary
The Site The Site is situated on land west of Woodbastwick Road in the village of Blofield Heath,
Norfolk, and currently comprises rough grass/meadow and some farm outbuildings.
The development boundary encloses an area of approximately 1.5ha. Residential
development is present to the east and south, with open farmland present to the north
and west of the Site.
Proposed Development
The proposed development comprises 4 residential properties and associated
infrastructure.
Geology The British Geological Survey (BGS) 1:50,000 map indicates the Site to be directly
underlain by superficial geology of the Happisburgh Glacigenic Formation (Diamicton –
Glacial Till). This in turn is underlain by bedrock geology of the Crag Formation (Sand
and Gravel).
Hydrology The nearest surface watercourse is a ditch located along the southern boundary, which
continues to flow southwards and westwards, eventually discharging into Witton Run
located approximately 1.3km south west of the site.
Hydrogeology The bedrock aquifer (Crag Formation) is designated as a Principal Aquifer. The
Happisburgh Glacigenic Formation (Diamicton) is designated as a Secondary
(Undifferentiated) Aquifer.
Flood Risk Zone Environment Agency Flood Map indicates the development site to be located within
FLOOD ZONE 1; an area where flooding from rivers and the sea is very unlikely. There is
less than a 0.1 per cent (1 in 1000) chance of flooding occurring each year.
Infiltration Testing Percolation testing has not been undertaken. The underlying Glacial Till is characterised
by poor drainage characteristics and infiltration drainage methods are considered highly
unlikely to be suitable.
Surface Water Drainage Strategy
A hierarchical approach to the drainage strategy has been considered for this
development in accordance with a sustainable (SuDS) approach.
As infiltration drainage methods are unlikely to be suitable for soakaway drainage, the
most appropriate form of surface water drainage for this site is sub-surface storage with
a controlled discharge to the adjacent watercourse.
Land off Woodbastwick Road, Blofield Heath Drainage Strategy Report
3097 Version 1 2
Surface water run-off from roof areas, up to the 100 year plus climate change storm
event, will be drained to individual plot cellular attenuation storage tanks. Each will
have a hydrobrake, or similar device, with the combined discharge equal to the natural
greenfield (QBAR) run-off rate.
The Shallow soils, within the top 0.5m, are likely to facilitate infiltration drainage for the
private estate road and property driveways that will be constructed of permeable
surfaces.
Water butts will be provided for garden use to reduce run-off volumes and treated
water consumption.
Surface Water
Runoff Quality
Surface water runoff from paved surfaces and roofs will receive adequate levels of
treatment to remove pollutants and to ensure there is no detrimental impact on the
water environment.
Exceedance Flows Exceedance flows will be routed via the estate road towards the existing ditch along the
southern boundary, thus ensuring both the proposed development and existing
development is protected from exceedance flows.
Foul Drainage
Strategy
The incumbent sewerage provider for the area is Anglian Water Services Ltd. There is
an existing foul sewer in Woodbastwick Road to which a gravity connection could be
made.
Summary The drainage strategy meets sustainable drainage criterion and ensures no harm to the
water environment.
This report demonstrates that the proposed development would not increase flood risk
to the Site, its occupants or the surrounding existing properties.
This Executive Summary contains an overview of the key findings and conclusions in this report. No reliance
should be place on any part of the Executive Summary until the whole of this report has been read. Other
sections of the report may contain information which puts into context the findings summarised in the
Executive Summary.
Land off Woodbastwick Road, Blofield Heath Drainage Strategy Report
3097 Version 1 3
Introduction
1.1 Bingham Hall Associates (BHA) has been commissioned by David Futter Associates Ltd (DFAL),
to prepare a Foul & Surface Water Drainage Strategy Report for land off Woodbastwick Road,
Blofield Heath, to be referred to hereafter as ‘the Site’. The proposed development comprises 4
residential properties and associated infrastructure. The Site Layout Plan is provided in
Appendix A.
1.2 The report follows the guidance set out in:
National Planning Policy Framework 2012 (NPPF)
National Planning Policy Guidance.
SuDS Manual 2015 (C753)
1.3 The following data was reviewed as part of this assessment:
British Geological Survey’s (BGS) ‘Geology of Britain’ on-line maps
We have also utilised our knowledge of the local area and experience in dealing with
similar related matters.
Land off Woodbastwick Road, Blofield Heath Drainage Strategy Report
3097 Version 1 4
Site Appraisal
Site setting
2.1 The Site is situated on land west of Woodbastwick Road in the village of Blofield Heath, Norfolk,
and currently comprises rough grass/meadow and some farm outbuildings.
2.2 The development boundary, as identified in Figures 2.1 and 2.2, encloses an area of
approximately 1.5ha. Residential development is present to the east and south, with open
farmland present to the north and west of the Site.
Figure 2.1: Site Location Plan
Site
Land off Woodbastwick Road, Blofield Heath Drainage Strategy Report
3097 Version 1 5
Figure 2.2: Site Location Plan: Aerial View
Topography
2.3 The topographic survey, included within the Site Layout Plan (Appendix A), indicates that the
Site slopes towards the south, from an elevation of approximately 23.00mAOD down to
21.75mAOD nearest to the drain along the southern boundary.
Geology
2.4 The British Geological Survey (BGS) 1:50,000 map indicates the Site to be directly underlain by
superficial geology of the Happisburgh Glacigenic Formation (Diamicton – Glacial Till). This is
turn is underlain by bedrock geology of the Crag Group (Sand and Gravel).
Site
Land off Woodbastwick Road, Blofield Heath Drainage Strategy Report
3097 Version 1 6
Hydrology
Surface water features
2.5 There are no surface water features on Site.
Surface watercourses
2.6 The nearest surface watercourse is a ditch located along the southern boundary, which
continues to flow southwards and westwards, eventually discharging into Witton Run located
approximately 1.3km south west of the site.
Site Sensitivity
Hydrogeology - Superficial Aquifer
2.7 The Happisburgh Glacigenic Formation (Diamicton – Glacial Till) is designated as a Secondary
(Undifferentiated) Aquifer. This is assigned in cases where it has not been possible to attribute
either category A or B to a rock type. This means that the layer in question has previously been
designated as both minor and non-aquifer in different locations due to the variable
characteristics of the rock type.
Hydrogeology - Bedrock Aquifer
2.8 The bedrock aquifer (Crag Group – Sand and Gravel) is designated as a Principal Aquifer (i.e.
high intergranular and/or fracture permeability - meaning they usually provide a high level of
water storage. They may support water supply and/or river base flow on a strategic scale).
Groundwater Vulnerability
2.9 The groundwater vulnerability mapping indicates the Site is underlain by high leaching potential
soils.
Source Protection Zone
2.10 The Site is not within a Source Protection Zone.
Infiltration Testing
2.11 Percolation testing has not been undertaken. The underlying Glacial Till is characterised by
poor drainage characteristics and infiltration drainage methods are considered highly unlikely to
be suitable.
Flood Risk Zone
2.12 The Environment Agency (EA) Flood Map indicates the development site to be located within
FLOOD ZONE 1; an area where flooding from rivers and the sea is very unlikely. There is less
than a 0.1 per cent (1 in 1000) chance of flooding occurring each year.
Land off Woodbastwick Road, Blofield Heath Drainage Strategy Report
3097 Version 1 7
Natural (Greenfield) Run-off Rate
2.13 The natural (greenfield) runoff rate for a 1.0ha area for the 1 year, QBAR, 30 year, and 100
year, storm events has been calculated in accordance with the ICP SuDS Mean Annual Flood
methodology (refer to CIRIA C753 - SuDS Manual) as noted in Table 2.1. Calculations are
shown in Appendix B.
Natural Run-Off rates (l/s/ha)
Return period (yrs) 1 (QBAR) 30 100
2.5 2.8 6.8 10.1
Table 2.1: Natural Run-Off Rate
Sewerage
2.14 There is an existing Anglian Water foul water sewer along Woodbastwick Road. There are no
surface water sewers.
Climate Change
2.15 The importance of climate change in regard to flooding and development is highlighted in the
NPPF and the impacts of climate change will be taken into account when designing the new Site
drainage infrastructure.
2.16 In accordance with the NPPF, the climate change allowance is dependent upon the
development lifespan. This development falls within the upper end limit as described in Table 2
(https://www.gov.uk/guidance/flood-risk-assessments-climate-change-allowances) requiring an
allowance of 40% for the increase in rainfall rates.
Land off Woodbastwick Road, Blofield Heath Drainage Strategy Report
3097 Version 1 8
Foul & Surface Water Drainage Strategy
Existing Surface Water Drainage
3.1 The topography dictates that surface water falls naturally to the ditch along the southern
boundary of the site. It is understood that the existing farm buildings are undrained and surface
water falls direct onto the surrounding ground.
Surface Water Drainage Strategy
3.2 The NPPF requires the surface water drainage strategy to follow a sustainable (SuDS) approach.
The emphasis of SuDS is to first consider source control (i.e. disposal of runoff within the plot
boundary, followed by site control (site wide disposal) and then regional control (appropriate for
larger development with strategic drainage infrastructure). Where possible the drainage
strategy should target a zero runoff from the immediate development area.
3.3 A hierarchical approach to the drainage strategy has been considered for this development in
accordance with Table 4.1. Each method is assessed to reach a conclusion appropriate to the
development.
Hierarchical SuDS Assessment
Comment Issues To Consider
Appropriate To
Development
Green roofs Can be used on suitable low
rise buildings
Safe maintenance access
In keeping with character/appearance of adjacent buildings
Unlikely to be
appropriate due to appearance of adjacent dwellings and ‘traditional’ house type design
Rainwater Harvesting
Rainwater harvesting reduces the total runoff volume from the developed Site, particularly first 5mm of rainfall, and reduces treated water consumption
Economics for full rainwater harvesting systems
Full rainwater harvesting unlikely to be economical for this Site
Water butts for roof runoff appropriate to development
Plot infiltration Reduces total runoff volume from the developed Site
Underlying geology is likely to have poor drainage characteristics, therefore, unsuitable for infiltration drainage
Not appropriate
Permeable Paving & Sub-Base Drainage
Can be used to provide pavement runoff water quality enhancement (treatment train) and sub-base attenuation
Permeable paving proprietary sub-base storage reduces requirements and
Shallow soils within the top 0.5m are likely to be suitable for infiltration drainage via permeable surfaces
Impact of saturation on pavement stability to be considered possibly requiring extensive use of impermeable
Appropriate
Land off Woodbastwick Road, Blofield Heath Drainage Strategy Report
3097 Version 1 9
volumes of storage structures
membranes and under-drainage Specialist maintenance
equipment
Swales Swales provide above ground flood conveyance routes
Water quality enhancement is provided by filtration through vegetation and stone media
Swales are reliant on ground porosity for infiltration
Underlying geology is likely to have poor drainage characteristics, therefore, unsuitable for infiltration drainage
No space available for open basins in agreed site layout.
Not appropriate
Infiltration
Basins
Infiltration basins can be
located within landscaped areas to attenuate storm flows up to the 100 year plus climate change event
Underlying geology is likely to
have poor drainage characteristics, therefore, unsuitable for infiltration drainage
Health and safety issues for potential open water bodies in residential areas.
No space available for open basins in agreed site layout.
Not appropriate
Detention Ponds
Detention basins can be located within landscaped areas to attenuate storm flows up to the 100 year plus climate change event
Health and safety issues for potential open water bodies in residential areas.
No space available for open basins in agreed site layout.
Not appropriate
Sub-Surface Storage (Tanks & Pipes)
Suitable for use where there is insufficient space for an
open basin Suitable for use where other
factors prevent the use of open basins
Below ground tanks or oversized pipes can be
considered as part of a controlled discharge system
Appropriate to development
Table 3.1: SuDS Assessment
3.4 In terms of a means of disposal of surface water NPP Guidance (Paragraph: 080 Reference ID:
7-080-20150323) requires a Surface Water Hierarchy to be considered. This requires
consideration to be given in order of priority to:
a. disposal to the ground
b. disposal to a watercourse
c. disposal to a public surface water sewer
d. disposal to a combined sewer
Land off Woodbastwick Road, Blofield Heath Drainage Strategy Report
3097 Version 1 10
3.5 Based on the assessment provided in Table 4.1, and in accordance with the Surface Water
Hierarchy, the most appropriate method of surface water management and disposal is as set
out below. The Drainage Strategy Plan is provided in Appendix C.
Rainwater harvesting using water butts for roof water run-off to reduce the total
volume of water discharged
Permeable paving of private drives and private estate road
A controlled discharge to the watercourse with the discharge rate controlled to the
natural greenfield (QBAR) run-off rate. The QBAR run-off rate to be applied to the
design impermeable area – see Table 3.2, below:
Development Discharge Rate
QBAR Natural discharge rate
4.2l/s 3.6l/s
Table 3.2: Development runoff rate
3.6 Each property will have an attenuation storage tank to accommodate up to the 100 year plus
climate change storm event. Attenuation volumes will be based on the design impermeable
area of each plot plus 10% allowance for development creep in accordance with CIRIA C753 –
see Table 4.3. Attenuation storage calculations are provided in Appendix D.
3.7 Plots 1-3 will each have a storage tank with dimensions of 3m x 4.5m x 0.8m deep. Plot 4 will
have a storage tank with dimensions of 3m x 3.5m x 0.8m deep. Discharge from each tank will
be controlled by a hydrobrake, or similar device, with the combined discharge equal to the
natural greenfield (QBAR) run-off rate.
Development Attenuation Volumes
Plot (s) Impermeable Area
ha
Plot Area With Allowance For
10% Creep ha
Discharge Rate
Total Attenuation
Storage Volume
1-3 0.027 0.03 1.1l/s 12.0m3
4 0.021 0.023 0.9l/s 9.4m3
Combined
Development Totals
- 0.113 4.2l/s -
Table 3.3: Development attenuation volumes
3.8 Each attenuation storage tank will remain in the private ownership of the respective properties
served.
Land off Woodbastwick Road, Blofield Heath Drainage Strategy Report
3097 Version 1 11
Surface Water Runoff Quality
3.9 In accordance with NPPF (Section 110) the development should not have a detrimental impact
on the environment, including the water environment. NPP Guidance (Paragraph: 016
Reference ID: 34-016-20140306) provides advice on the benefits of ensuring runoff quality is to
an appropriate standard to enhance the water environment.
3.10 The SuDS Manual 2015 provides guidance on the treatment of surface water runoff for the form
of land use and sensitivity of receiving water body. Table 3.3 (SM – 2015) rates the pollution
hazard from residential roof water runoff as VERY LOW. The pollution hazard for individual
property driveways and low traffic roads (i.e. cul-de-sacs) as LOW. The requirement for roof
water runoff is the removal of gross solids and sediments only. Runoff from LOW hazard areas
requires a simple index approach. The method of water quality treatment may require a single
mitigation system, or combination of mitigation components depending on the pollution hazard
rating. A single SuDS component with a high capacity for removal of pollutants can be suitable.
3.11 Roof water runoff will be treated through the provision of trapped gullies and water butts to
intercept gross solids and sediment, guidance will be provided to householders on appropriate
maintenance requirements including regular cleaning of gullies.
3.12 The simple index approach requires that the mitigation indices for the mitigation proposed
exceeds the pollution hazard indices for the pollution hazard level. Table 4.2 provides
information on hazard indices and mitigation indices.
Land Use
Total Suspended
Solids (TSS) Metals Hydrocarbons
Pollution Indices Low traffic roads (LOW hazard
rating) 0.7 0.6 0.7
Mitigation Indices
Constructed Permeable Pavement (where a suitable filtration layer is included that provides treatment, and including a geotextile at the base separating the
foundation from the subgrade) underlain by a soil with a good contaminant attenuation potential of at least 300mm in depth.
Table 3.4: Runoff mitigation assessment
3.13 It is therefore demonstrated that roof water runoff can be adequately treated through the use
of trapped gullies and water butts, to intercept gross solids and silt, and a constructed
permeable pavement, for which the run-off percolates, will provide adequate water quality
treatment for the private estate roads and property driveways.
Land off Woodbastwick Road, Blofield Heath Drainage Strategy Report
3097 Version 1 12
Exceedance Flows
3.14 Exceedance flows are those in excess of the design storm event (i.e. > 1 in 100+CC).
Exceedance flows will be routed via the estate road to Flegg Green and to the offsite
watercourse. Exceedance flow flood routes are shown on the Drainage Strategy Plan at
Appendix C.
Foul Drainage Strategy
3.15 The incumbent sewerage provider for the area is Anglian Water Services Ltd (AWS).
3.16 There is an existing foul sewer in Woodbastwick Road to which a gravity connection could be
made.
Flood Risk Management Measures
3.17 Finished floor levels of the residential properties will be set at least 150mm above the prevailing
ground levels in Flood Zone 1. All external hard standing areas will be designed to fall away
from the properties.
3.18 In accordance with the NPPF, access and egress to the Site during all storm events should be
considered with preference being over dry land. As the Site is wholly in Flood Zone 1 the
access routes to and from the properties are naturally above the 1 in 100 year plus climate
change event.
3.19 All on-site foul and surface water drainage infrastructure will be constructed to current building
regulation standards.
Residual Risks
3.20 Whilst the on-site drainage will be constructed to current building regulation standards, there
always remains a small residual risk of flooding due to blockage or failure of on-site private
drains.
3.21 There are also further residual risks related to the maintenance of off-site drainage assets by
third parties, such as highway drainage, foul sewers and drainage ditches.