![Page 1: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/1.jpg)
IEEE 802.3 RTPGE PHY Study Group
Zwickau University of Applied SciencesEMC Lab Testing for Automotive
Ethernet Physical Layer Qualification
Michael JonesMicrel Semiconductor
September, 2012 - Geneva
![Page 2: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/2.jpg)
Introduction
• Overview of the work Zwickau University ofApplied Sciences (FTZ) have performed to aidthe qualification of Ethernet Physical Layer forAutomotive applications
• We feel that these test methods will be usefulinformation for the RTPGE Study Group
![Page 3: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/3.jpg)
Introduction to FTZ• Expert knowledge of EMC test methodology• Vast experience in Automotive EMC qualifications• Commissioned by the German OEM car makers to
develop lab bench EMC test methods• Reduces the high cost & limited availability of stripline testing
facilities• Through extensive testing (since 2008), excellent
correlation has been shown between FTZ testsetup and classic stripline tests
• The FTZ testing is now the preferred 1st step beforestrip line testing is performed in Europe• Similar to UNH IOL
Note – Any test results in this presentation have been performed by FTZ
![Page 4: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/4.jpg)
Stripline EmissionsBased on CISPR25FTZ Dummy ECU Board
RF EmissionsBased on IEC 61967-1/4FTZ RF Board
FTZ lab vs Classic Stripline Testing
Direct Power Injection(DPI)Based on IEC 62132-1/4FTZ RF Board
Bulk Current Immunity(BCI)Based on ISO 11452-4FTZ Dummy ECU Board
FTZ Lab based Stripline (chamber) based
![Page 5: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/5.jpg)
RF Test Board Functional Diagram
µC Used to generatetraffic if the PHY cannot
TC Ethernet transceiverunder test (DUT)
BIN Filter network, includingtransformer, termination,ESD protection
CN EMC Coupling network
![Page 6: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/6.jpg)
RF Board
• Same board design / setup / test method• Consistent comparable results
PHY under test
Test PointsDPI / RF
Traffic Generator Board
![Page 7: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/7.jpg)
Coupling Networks
NOTE: For worse case testingcoupling network is modified to+/-2.5% unbalanced
Line Emissions coupling network
Voltage Supply Emissions coupling network
Line Immunity coupling network
![Page 8: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/8.jpg)
Emission of RF Disturbances(RF Test Board)
![Page 9: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/9.jpg)
RF Emissions Functional Diagram
![Page 10: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/10.jpg)
Rohde & Schwarz ESCI7 Standard Compliant Measuring Receiver
Test controller
Photo of the RF Emissions Test Setup
PHY under test
![Page 11: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/11.jpg)
Typical 100BASE-TX PHY Emissions over UTP
• High Energy 50MHz to 100MHz due to line data• Sensitive to transformer, termination
• 25MHz /125MHz (line) harmonics
![Page 12: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/12.jpg)
Simulating worse case - Unsymmetrical Testing
• Coupling network is modified to +/-2.5% unbalanced• Simulates worse case conditions
• Transformer, termination, connector….
![Page 13: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/13.jpg)
Immunity to RF Disturbances(RF Test Board)
![Page 14: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/14.jpg)
DPI Immunity Functional Diagram
![Page 15: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/15.jpg)
Example of PHY passing DPI Immunity
39dBm DPI equivalentto 106dBuA / 200mA(Level 5) BCI
![Page 16: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/16.jpg)
RF Emissions & Immunity usingStripline methods
(Dummy ECU Test Board)
![Page 17: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/17.jpg)
Dummy ECU Test Board Functional Diagram
1.7m–2m cable
• Same schematic / layout used as the RF Test Board
![Page 18: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/18.jpg)
Strip line Emission test
• Stripline emission measurement according to CISPR25 with 1.8mcable length
• 2x2 unshielded twisted pair
• Dummy ECU used : Processor + PHY (DUT) board• Fibre link to PC running monitoring tool• Any errors monitored
![Page 19: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/19.jpg)
Bulk Current Immunity test
• BCI test according to ISO 11452-4 (substitution method) with1,8m cable length
• 2x2 unshielded twisted pair
• Dummy ECU used : Processor + PHY (DUT) board• Fibre link to PC running monitoring tool• Link, CRC and Flow control errors monitored for both nodes
2x2 UTP (1.8m)
BCI clamp
Dummy ECU - DUT2Dummy ECU – DUT1
Power Fibre link to PC
![Page 20: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/20.jpg)
Example of OEM BCI Immunity limits
100mA(Level 4)
200mA(Level 5)
[mA]
![Page 21: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/21.jpg)
Summary
• Such test methodologies can provide a meansto qualifying the Ethernet PHY Layer• PHY Transceiver and Network Interface (transformer,
termination etc)• Lowers the cost and time versus classic stripline
methods• Testing performed on lab bench and not EMC Chamber
• Extremely useful during pre-qualification /selection of Ethernet PHY Layer components
![Page 22: Zwickau University of Applied Sciences EMC Lab Testing for …grouper.ieee.org/groups/802/3/RTPGE/public/sept12/jones_01_0912.… · EMC Lab Testing for Automotive Ethernet Physical](https://reader033.vdocuments.us/reader033/viewer/2022052519/5f159f842a2e5a1cc633b40f/html5/thumbnails/22.jpg)
IEEE 802.3 RTPGE PHY Study Group
Thank you