Download - ZPAS Solutions for DATA CENTER
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS Solutions for DATA CENTER
ZPAS Solutions for Data CenterZPAS GROUP
Infrastructure of Data Center
- server cabinets
- precise air-conditioning
- guaranteed power supply systems
- fire extinguishing systems
- electronic security systems,
- enviromental condition monitoring systems–
ZPAS Control Oversee,
ZPAS Solutions for DATA CENTER
ZPAS Solutions for Data CenterZPAS GROUP
Server cabinet 19”
Server cabinet DC 19”:
- cabinet meets the requirement of EIA-310D,
- intended for use in Data Box and row system with side and
row heat exchangers,
- possibility to join cabinets in row,
- static capacity 1360 kg, possibility of increasing to 1500kg
- possibility of applying electronic access control system.42
U,
45
U,
47
U
1000mm,1200mm 600mm, 800mm
clearance 80% clearance 69%
ZPAS Solutions for Data CenterZPAS GROUP
Server cabinet DC 19”
Cabinet frame features openings for arranging the cabinets in rows with special joints.
Special joint
Fixing of cabinet row with special joints allows to:
- rigid and stable construction- possibility of joining cabinets with side panels
ZPAS Solutions for Data CenterZPAS GROUP
1
3
2
Air flow management in server cabinets
1) 2) 3)
Vertical hot air duct Cold air deflector Air flow guide vane
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS Data Box – modular solution based on cabinets 19” DC
Designing based on standard system components.
We create solutions easy for modification, extension and reconfiguration.
Cold Aisle
Hot Aisle
ZPAS Data Box
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS Data Box – cable management systems
Cable distribution on the top plate of server cabinets
- single cable trace
- duplex cable trace
- transition between rows of cabinets
Baks, Cablofil
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS Data Box – Interesting projects
Interesting projects
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS Data Box – Interesting projects
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS Data Box – Interesting projects
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS Data Box – Interesting projects
ZPAS Solutions for Data CenterZPAS GROUP
Server cabinet with increased IP Protection Degree
- with sideway heat exchangers- with heat exchanger compartment in server cabinet
Server cabinet with IP54
Server cabinet 800x1000 + 300x1000 with sideway heat exchanger
Benefits
- steady flow of cold air over the entire height of the cabinet,- fire extinguishing in a single cabinet- automatically opening of the door in case of emergency air conditioner / temperature rise- the ability to easily move the cabinet with all systems
Server cabinet 900x1000 with interior heat exchanger compartment
ZPAS Solutions for Data CenterZPAS GROUP
Cable management systems
Cable management components
vertical and horizontal
in server cabinet
Cable management components outside cabinets
ZPAS Solutions for Data CenterZPAS GROUP
Air flow management components
3
1
2
Management of air flow - rules to be observed:
- proper location of air conditioners, designing of cabinet
rows with hot or cold aisles,
- using of blanking plates 19 "
- sealing of cabinets around usage space
- all cable entries to be sealed
- ensure adequate air flow to used equipment
- monitors, servers, of tower-type not to be put on shelfs
c)1) 2)
3) 4)
ZPAS Solutions for Data CenterZPAS GROUP
Special cabinets
Server cabinets 1000 x 1200mm intended for use in equipments with sideways air flow
Directing the flow of cooling air through the air guides
Nexus
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS Air-conditioning systems
Medium: Water chiller unit Cooling: 10 – 30kWEquipment: Carel
Air-conditioning systems
Heat exchangers ZPAS
Row heat exchanger cSideway heat exchanger
Air-conditioning systems
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS Air-conditioning systems
Medium: water chiller unitCooling: 10 – 30kWEquipment: Carel
Air-conditioning systems
Heat exchangers ZPAS
Row heat exchanger cSideway heat exchanger
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS Air-conditioning systems
Air-conditioning systems
Heat exchangers ZPAS
Row heat exchanger cSideway heat exchangerMedium: water chiller, DX (R410A)Cooling efficiency:- Water chiller: 12,3 – 37,7kW- DX: 4,5 – 22,5kWEquipment: STULZ
EC
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS Air-conditioning:
- even distribution of cold air at the whole height of the air -conditioner
- controller with keyboard and display (adjustment of air-conditioning parameters)
- monitoring of the air -conditioning via Ethernet
- heat capacity control by controlling the flow of refrigerant or with variable speed of
fans,
- temperature and humidity measurements
Benefits:-air-conditioners are in rows and not on the perimeter of the room, shortening air flow path causes a reduction of mixing of hot and cold streams and lower power consumption
- hot air is captured directly from the IT equipment before mixing with colder ambient air giving
higher air conditioner efficiency- modular design - easy to create a redundant N +1,
- this solution does not require raised floor for distributing of cold air
ZPAS Air-conditioning systems
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS Air-conditioning systems
Air-conditioning systems
Heat exchangers ZPAS
Medium: water chiller, DX (R410A)
Precison air-conditioning cabinets
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS Air-conditioning systems
Air-conditioning systems
Medium: water chiller, DX (R410A)
Water chiller units and condensers
Heat exchangers ZPAS
Precision air-conditioning cabinets
Hydraulic distributor
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS single cabinet air-conditioning systems
SLIMAir-conditioners mounted on doors and sides. Coolling capacity 1050 – 8000W
TOPRoof mounted air-conditioner,Cooling capacity330 – 5200W
EXW RACKAir-conditioner mounted in rack space 19’’, cooling capacity up to 2500W
Recommended cabinet configuration:- recommended IP 54 - front and rear door without perforation- side panels- sealed all cable entries
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS PDU power strips
16A 16, 32, 3x16, 3x32A
Types of power plugs
Types of outlets
Examples of power strips
LZ-532
LZ-332
LZ-326
LZ-3164
LZ-3321
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS monitoring power strips
16A 16, 32, 3x16, 3x32A
Types of power strips
Types of outlets
ZPAS Solutions for Data CenterZPAS GROUP
SOFT-START:automatic soft-starting of devices according to time delay scenario after power supply recovery
MASTER-SLAVE:automatic shut down of unnecessary devices; saving power
PDU-THERMOSTAT:- mulitstage cooling control- multi-heating control - ability to work a combined heating/cooling;
Monitoring on-line:- current and power in the oultlets - current power supply- temperature
Microprocessor power control panel
ZPAS Solutions for Data CenterZPAS GROUP
FK-RACK fire extinguisher system
Panel FK-RACK 19” :
- 2 kg of gas extinguishing
- redundant power supply
- two optical smoke detector,
- sounder,
- interface for communication via Ethernet
- 4 FK-RACK Slaves (RS 485) can be connected to
FK-Rack Master
Unsplit automatic fire panel FK-Rack is designed for fire
detection and extinguishing control process using gas FE-
36. The panel is designed for use in server racks holding
not more than 3 m3. It does not cause damage to the data
stored on the storage media.
FK-RACK Master
FK-RACK Slave
Fire extinguisher system
ZPAS Solutions for Data CenterZPAS GROUP
FK-RACK fire extinguisher system
Panel FK-RACK 19” :
- 2 kg of gas extinguishing
- redundant power supply
- two optical smoke detector,
- sounder,
- interface for communication via Ethernet
- 4 FK-RACK Slaves (RS 485) can be connected to
FK-Rack Master
Unsplit automatic fire panel FK-Rack is designed for fire
detection and extinguishing control process using gas FE-
36. The panel is designed for use in server racks holding
not more than 3 m3. It does not cause damage to the data
stored on the storage media.
FK-RACK Master
FK-RACK Slave
ZPAS Solutions for Data CenterZPAS GROUP
Fire extinguishing installation using gas FM-200, NOVEC1230
1
2
3
4
5
6
7
1. fire central unit 2. gas cylinders3. discharge nozzle4 smoke detectors5 smoke damper6 start and stop buttons7 opto-acoustic signal unit
ZPAS Solutions for Data CenterZPAS GROUP
- monitoring of access control system
- archiving of all events by remote configuration of terminals,
- add and manage of users
- receiving alerts and visualization of the current state
-the ability to remotely opening the cabinet, in the absence of an
authorization user
- map editor, which graphically shows the terminal layout
Access control systems
Access control systems and monitoring
ZPAS Solutions for Data CenterZPAS GROUP
- monitoring of access control system
- archiving of all events by remote configuration of terminals,
- add and manage of users
- receiving alerts and visualization of the current state
-the ability to remotely opening the cabinet, in the absence of an
authorization user
- map editor, which graphically shows the terminal layout
Access control systems
ZPAS Solutions for Data CenterZPAS GROUP
Contactron or microswitch
Smoke detector 3%
Probe
Motion detector
Ethernet RJ45Connection to controlling center
Climate control monitoring
ZPAS Solutions for Data CenterZPAS GROUP
Climate control monitoring ZPAS Control Oversee
ZPAS Solutions for Data CenterZPAS GROUP
Climate control monitoring ZPAS Control Oversee
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS interesting projects
Server room in ZPAS
Interesting projects
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS interesting projects
Server room in ZPAS
ZPAS Solutions for Data CenterZPAS GROUP
ZPAS interesting projects
ZPAS Solutions for Data CenterZPAS GROUP
Kontakt
Zakład Produkcji Automatyki Sieciowej S.A.
Przygórze 20957-431 Wolibórz
Krystian Guzara
Tel. +48 748 720 153GSM +48 605 434 386Fax +48 748 724 074E-mail: [email protected]
www.zpasgroup.eu