Zhen YAN, Muon Offline DQ meeting, 05/10/2015
Signed off runs(express stream) since last Friday meeting
Default defects: MS_RPC_BA_ROD_PROBLEM_1 MS_RPC_BC_ROD_PROBLEM_1
Additional defects/comments Run 280853
MS_CSC_EA_DISCONNECTED_2 Run 280950
TGC C11 HV glitch
Muon Offline DQ shifter report
Run 280950Project Tag: data15_13TeVRun Start: 2015-10-03 19:35 CESTRun End: 2015-10-04 12:19 CEST# lumi blocks: 1062Events: 49371897Stable beams: YesOnline ATLAS Ready luminosity: 142.164 pb-1
Run 280853Project Tag: data15_13TeVRun Start: 2015-10-02 09:12 CESTRun End: 2015-10-02 13:14 CEST# lumi blocks: 258Events: 2861280Stable beams: YesOnline ATLAS Ready luminosity: 10.657 pb-1
Run 280862Project Tag: data15_13TeVRun Start: 2015-10-02 14:56 CESTRun End: 2015-10-03 07:37 CEST# lumi blocks: 1062Events: 50738248Stable beams: YesOnline ATLAS Ready luminosity: 147.144 pb-1
Zhen YAN, Muon Offline DQ meeting, 05/10/2015 2
I added “MS_CSC_EA_DISCONNECTED_2” defect for CSC since AL05 layer 3 and 4 channels (1-96) dead.
Relevant ELOG entries :https://atlasop.cern.ch/elisa/display/279106
Problem didn’t appear in later runs.
Zhen YAN, Muon Offline DQ meeting, 05/10/2015 3
No major issues.
Zhen YAN, Muon Offline DQ meeting, 05/10/2015 4
No major issues except TGC HV glitch.No defects needed.
Zhen YAN, Muon Offline DQ meeting, 05/10/2015 5
General issues: CSC
Link loss problem occurs time to time MDT
Chamber drop/recovery during the run Pathological/Disabled chambers during long run (randomly) ~ 10 MLs consistently have low efficiency(<70%) on BIC & BIA (page 6)
RPC Feet region sectors didn’t fully functional
Data misalign on sector 25 Tower re-sync
TGC SSW drop and ROD busy (TGC big storm errors)
General comments : Inconsistent default ranges on some web display plots
RPC coverage plots : BA A13 LowPt1 eta, BC C14 RO HighPt0/1 eta and phi MDT ML efficiency plots : BIS8A10/A14 BML6A/C13 histogram missing
Z axis color scheme is good at efficiency plots but not quiet useful on some occupancy/hit plots due to noisy channel and geometry effect
RPC GlobalHitsPerRPCOuter MDT OccupancyVsLB_ECInner MDT BEE NumberOfHitsInBAExtraPerMultiLayer_ADCCut TGC Strip_Occupancy_Map_A Segments_Z_chamberIndex_perSector
Zhen YAN, Muon Offline DQ meeting, 05/10/2015 6
Zhen YAN, Muon Offline DQ meeting, 05/10/2015 7
Backup slides
Zhen YAN, Muon Offline DQ meeting, 05/10/2015 8
Further concerning : ACR shifter Offline DQ shifter
Usually offline DQ shifter has to dig out useful information based on the shift summary submitted by ACR shifter which they written with their personal style
Online DQ report is the proper solution and it can be done with good shifter Sub-detector on-call expert Offline DQ shifter
Join the DQ meeting every Monday, Wednesday and Friday Update the detector condition and known problems to DQ shifter in time Daily summary(like TGC) or Run base summary(DQ shifter) to ELOG
Offline DQ expert Offline DQ shifter Specific explanation on those intolerable defects(documents, references and
examples) Optimize/Tuning offline DQ plots Document more tracking plots(MCP part) if possible
My concerning and proposal (just for leading discussion)
Zhen YAN, Muon Offline DQ meeting, 05/10/2015 9
Really good and useful DQ report from online Muon shifter “Carsten Bittrich”https://atlasop.cern.ch/elisa/display/279560
Could be even better if we specify the template with well pre-defined catalogue/checklist