Download - Wiring Harness Connector ZF4HP16
Wiring harness connector
1 Transaxle output speed sensor (+)2 Transaxle output speed sensor (-)3 Solenoid valve (+)4 Transaxle temperature sensor (-)5 Pressure control valve solenoid vlave (+)6 Pressure control valve solenoid vlave (EDS3)7 Pressure control valve solenoid vlave (EDS4)8 Not used9 Transaxle temperature sensor (+)10 Pressure control valve solenoid vlave (EDS5)11 Pressure control valve solenoid vlave (EDS6)12 Solenoid valve 113 Solenoid valve 214 Not used15 Transaxle output speed sensor (-)16 Transaxle output speed sensor (-)
ComponentPass
ThroughPins
Resistance20°C (68°F)
Ohms
Resistance ≥ 140°C(212°F) Ohms
Solenoid 1 3, 12 26.5±0.5Ω 26-345Ω (not relative to emperature)Solenoid 2 3, 13 26.5±0.5Ω 26-345Ω (not relative to emperature)Pressure control solenoid valve (EDS3) 5, 6 5.7±0.45Ω 5.3-6.3Ω (not relative to emperature)
Pressure control solenoid valve (EDS4) 5, 7 5.7±0.45Ω 5.3-6.3Ω (not relative to emperature)
Pressure control solenoid valve (EDS5) 5, 10 5.7±0.45Ω 5.3-6.3Ω (not relative to emperature)
Pressure control solenoid valve (EDS6) 5, 11 5.7±0.45Ω 5.3-6.3Ω (not relative to emperature)
Transaxle temperature sensor* 4, 9 980-1,000Ω
Transaxle input speed sensor 15, 16 830±5Ω 788-871Ω (not relative to emperature)
Transaxle output speed sensor* 1, 2 ∞ ∞* The resistance of the transaxle is necessarily dependent on the temperature.
DIAGNOSTIC TROUBLE CODE DIAGNOSISDIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION
DTC Description Indication Default ActionP0705 Park/Neutral Position Switch MIL ON The TCM will record operating
conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/ Substitute mode and constant 4th gear by hydraulic control.
After ignition LOCK/ON : 3rd gear by hydraulic control, position P, R and N also possible.
P0715 Input Speed Sensor Circuit Malfunction
MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/ Substitute mode and constant 4th gear by hydraulic control.
After ignition LOCK/ON : 3rd gear by hydraulic control, position P, R and N also possible.
Open lock up clutch.
P0716 Input Speed Sensor Circuit Range/Performance
MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/ Substitute mode and constant 4th gear by hydraulic control.
After ignition LOCK/ON : 3rd gear by hydraulic control, position P, R and N also possible.
Open lock up clutch.
P0717 Input Speed Sensor Circuit No Signal
MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/ Substitute mode and constant 4th gear by hydraulic control.
After ignition LOCK/ON : 3rd gear by hydraulic control, position P, R and N also possible.
Open lock up clutch.
DTC Description Indication Default ActionP0720 Output Speed Sensor Circuit
MalfunctionMIL ON The TCM will record operating
conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/ Substitute mode and constant 4th gear.
Open lock up clutch.
P0721 Output Speed Sensor Circuit Range/Performance
MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/ Substitute mode and constant 4th gear.
Open lock up clutch.
P0722 Output Speed Sensor Circuit No Signal
MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Vehicle running remains actual gear. Open lock up clutch.
P1839 EDS3 Output Shortage To Ground
MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/Substitute mode and constant 4th gear by hydraulic control.
After ignition LOCK/ON: 3rd gear by hydraulic control. Possible P, R and N also possible.
Power supply cut OFF to the EDS valve.
P1840 EDS3 output shortage to battery
MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/Substitute mode and constant 4th gear by hydraulic control.
After ignition LOCK/ON: 3rd gear by hydraulic control. Possible P, R and N also possible.
Power supply cut OFF to the EDS valve.
P1841 EDS3 output open MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
DTC Description Indication Default Action Adopt Emergency/Substitute mode and
constant 4th gear by hydraulic control. After ignition LOCK/ON: 3rd gear by
hydraulic control. Possible P, R and N also possible.
Power supply cut OFF to the EDS valve.
P1850 Solenoid 1 Output Shortage To Ground
MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/ Substitute mode and constant 4th gear by hydraulic control.
After ignition OFF/ON : 3rd gear by hydraulic control. Possible P, R and N also possible.
P1851 Solenoid 1 Output Shortage To Battery
Power Lamp Flashing
Power lamp will blink. The TCM will record operating
conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
P1852 Solenoid 1 Output Open MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/ Substitute mode and constant 4th gear by hydraulic control.
After ignition OFF/ON : 3rd gear by hydraulic control. Possible P, R and N also possible.
P1853 Solenoid 2 Output Shortage ToGround
MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/ Substitute mode and constant 4th gear by hydraulic control.
After ignition OFF/ON : 3rd gear by hydraulic control. Possible P, R and N also possible.
P1854 Solenoid 2 Output Shortage To Battery
MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/ Substitute mode and constant 4th gear by hydraulic control.
DTC Description Indication Default Action After ignition OFF/ON : 3rd gear by
hydraulic control. Possible P, R and N also possible.
P1855 Solenoid 2 Output Open MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/ Substitute mode and constant 4th gear by hydraulic control.
After ignition OFF/ON : 3rd gear by hydraulic control. Possible P, R and N also possible.
P1861 EDS4 Output Shortage To Ground
MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/Substitute mode and constant 4th gear by hydraulic control.
After ignition LOCK/ON: 3rd gear by hydraulic control. Possible P, R and N also possible.
Power supply cut OFF to the EDS valve.
P1862 EDS4 output shortage to battery
MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/Substitute mode and constant 4th gear by hydraulic control.
After ignition LOCK/ON: 3rd gear by hydraulic control. Possible P, R and N also possible.
Power supply cut OFF to the EDS valve.
P1863 EDS4 output open MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/Substitute mode and constant 4th gear by hydraulic control.
After ignition LOCK/ON: 3rd gear by hydraulic control. Possible P, R and N also possible.
Power supply cut OFF to the EDS valve.
P1864 EDS5 Output Shortage To Ground
MIL ON The TCM will record operating conditions at the time the diagnostic fails.
DTC Description Indication Default ActionThis information will be stored in the Failure Records buffer.
Adopt Emergency/Substitute mode and constant 4th gear by hydraulic control.
After ignition LOCK/ON: 3rd gear by hydraulic control. Possible P, R and N also possible.
Power supply cut OFF to the EDS valve.
P1865 EDS5 Output Shortage To Battery
MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/Substitute mode and constant 4th gear by hydraulic control.
After ignition LOCK/ON: 3rd gear by hydraulic control. Possible P, R and N also possible.
Power supply cut OFF to the EDS valve.
P1866 EDS5 Output Open MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/Substitute mode and constant 4th gear by hydraulic control.
After ignition LOCK/ON: 3rd gear by hydraulic control. Possible P, R and N also possible.
Power supply cut OFF to the EDS valve.
P1867 EDS6 Output Shortage To Ground
MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/Substitute mode and constant 4th gear by hydraulic control.
After ignition LOCK/ON: 3rd gear by hydraulic control. Possible P, R and N also possible.
Power supply cut OFF to the EDS valve.
P1868 EDS6 Output Shortage To Battery
MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/Substitute mode and constant 4th gear by hydraulic control.
After ignition LOCK/ON: 3rd gear by
DTC Description Indication Default Actionhydraulic control. Possible P, R and N also possible.
Power supply cut OFF to the EDS valve.
P1869 EDS6 Output Open MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/Substitute mode and constant 4th gear by hydraulic control.
After ignition LOCK/ON: 3rd gear by hydraulic control. Possible P, R and N also possible.
Power supply cut OFF to the EDS valve.
P1871 EDS Valve Power Supply Circuit Shortage To Battery
MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/Substitute mode and constant 4th gear by hydraulic control.
After ignition LOCK/ON: 3rd gear by hydraulic control. Possible P, R and N also possible.
Power supply cut OFF to the EDS valve.
P1874 Solenoid Valve Power Supply Circuit Shortage To Battery
MIL ON The TCM will record operating conditions at the time the diagnostic fails. This information will be stored in the Failure Records buffer.
Adopt Emergency/ Substitute mode and constant 4th gear by hydraulic control.
After ignition OFF/ON : 3rd gear by hydraulic control. Possible P, R and N also possible.
1. Control valve body2. Valve body wiring harness3. O-ring4. Plug5. Cable terminal6. Retaining clip7. Input speed sensor8. Cap screw9. Pressure control valve (EDS valve)10. Cap screw11. Fixing plate12. Fixing plate13. Cap screw14. Pressure control valve (EDS valve)15. Solenoid valve