VORTEX DIFFERENTIAL PRODucT INFO
Vortex Differential valves are ideal for use in water tanks which are filled by a pressure system controlled water pump. The valve gives a level difference which is adjustable from 50mm to 2.5m to minimise starting and stopping of the pumping system.
Description
Principle of Operation• The valve should be mounted at the top of the tank using a threaded tank inlet fitting.
• As the tank empties the weighted float travels down the cord until it hits the bottom stop. The valve then opens immediately to give a full flow.
• The valve now runs constantly and the weighted float rises until it hits the upper float stop. This lifts the arm and the valve shuts down.
• Observe the pressure that your pump runs at while the tank is filling. Set the pres sure switch to turn the pump off at least one bar above the running pressure.
Pressure Range1 Bar – 10 Bar (15psi-150 psi)
ApplicationsMaintaining Water Levels in:• Water Storage Tanks• Water Cisterns• Irrigation Applications
Features• High flow• Easily adjustable water level differentials between on and off (50mm - 2.5 m differentials obtainable).• Reduces pump operation to a mininum.• Valve unscrews from tail for easy Valve Access.• Ideal for all makes and models of tanks.
Available Inlet SizesVXVD32 32mm (1 ¼”)VXVD40 40mm (1 ½”)VXVD50 50mm (2”)VXVD114 1¼”NPTVXVD112 1½’’NPTVXVD2 2” NPT
1.5
1.0
0.5
0 100 200 300 400 500 600 700
2.0
2.5
Flow LPM
Imperial GPM
Inle
t Pre
ssur
e B
ar
20 40 60 80 100 120 140
35
30
25
20
15
10
5
PS
I
Flow Graph( All Sizes )
Vortex Vortex
Vortex Dimensions
H
BF
E
D C
G
A
I
A
B
C
D
E
F
G
H
I
108
110
270
31
65
208
62
132
40
mm inches
4 1/4
4 3/8
10 11/16
1 7/16
2 7/16
8 3/16
2 7/16
5 3/16
1 7/16
Vortex Dimensions Materials
GF Nylon
Acetal
ABS
EPDM
Urethane
304 Stainless Steel
Nitrile
HDPE
Valve Body
White Internal Parts
Arm Assembly
Diaphragm
Seal
Springs, Bolts, Nuts, Pin, Screws
O’Rings
Float
Maximum Temperature of Operation 60ºC, 140ºF
VORTEX DIFFERENTIAL DIMENSIONS & MATERIALS
VORTEX DIFFERENTIAL PRODucT INFO
2 DESCRIPTION CODE
1
2
3
4
5
6
7
8
9
10
VXPD2010
VXP2020
VXP2030
VXP2040
VXPD2050
VXPD2060
VXP2080
VXP2090
VXP2100
VXP2110
Actuator Cap6g x 10 S/S Screw Frost Pro Plug Frost Pro O’ring Valve Cap Assembly Damping Spring Bearings (set of two) Actuator Arm Bolt M6 x 65Washer M6 x 12.5
1
2
1
4
3
5
1
DESCRIPTIONCODE
3
2
CODE: VXVD
1
2
3
4
5
6
VXPD1010
VXPD1020
VXPD1030
VXPD1040
VXPD1050
VXPD1060
Weighted Tube Stop
Weighted Float
Upper Float Stop
Cord
Arm Extension
M5 x 12 Bolt
1
2
3
4
VXPD1
VXPD2
VXP3
Float Assembly
Cap & Actuator Assembly
Diaphragm Assembly
Base Assembly
DESCRIPTION CODE
VORTEX DIFFERENTIAL PARTS IDENTIFIcATION SHEET
2
3
4
DESCRIPTION CODE 4Vortex Retainer
Vortex Base
Vortex O’ring
Vortex Tail 32mm
Vortex Tail 40mm
Vortex Tail 50mm
Vortex Tail 1 ¼” npt
Vortex Tail 1 ½” npt
Vortex Tail 2” npt
1
2
3
4
VXP4010
VXP4020
VXP4030
VXP4040
VXP4045
VXP4050
VXP4055
VXP4060
VXP4065
1
1
23
45
89
10
6
4
6
7