OFF
ON
MENU6 °C
3SET SENSORSGAUGES
POINT
MAIN MENU
ALARMS
NEXTEXIT SELECT
NO ALARMS
NO ALARMS0 OF 0 ALARMS
EXIT
ALARM 28
PRETRIP ABORT1 OF 1 ALARMS
EXIT CLEAR HELP
ALARM 28
PRETRIP ABORT1 OF 1 ALARMS
EXIT CLEAR HELP
MENU6 °C
3SET SENSORSGAUGES
POINT
.1
TK 55526-2-PC-RO (Rev. 0, 07-12) ©Thermo King Corporation
1. Revenitilaafisajulstandard2. ApasatitastaMENU.3. ApasatitastaNEXTpanacandmeniul
Alarmavafiafisat.4. ApasatitastaSELECT.EcranulAlarma
vafiafisat.5. Dacanuexistaalarmevafiafisat
Alarm00.6. ApasatitastaEXITpentrurevenirela
afisajulstandard.7. Dacaexistaalarmeinregistrate,vorfi
afisatenumarulacestoraincepandcuceamairecentaparuta.
8. Dacaexistamaimultdeoeroare,apasatitastaNEXTpentruavedeafiecarecodalarma.
9. Dacaintervineoeroareimportanta,aparatulsevaopripentruaprevenidaunemajorealesalesialemarfurilor.Dacaseintamplaacestlucru,ecranulvaafisafaptulcaaparatulesteopritsicoduldeeroareceacauzatoprirea.
83 Temperaturascazutalichidderaciremotor84 Repornireratata85 Modfunctionarefortat86 Verificaresenzorpresiunerefulare87 Verificaresenzorpresiuneaspiratie89 VerificaticircuitulregulatoruluidesarcinaETV90 Suprasolicitareelectrica91 Verificarealimentareeletcrica92 Indicativulsenzoruluinememorat93 Presiunescazutaaspiratiecompresor94 Circuitsarcina#195 Circuitsarcina#296 Nivelscazutcombustibil98 Verificaresenzornivelcombustibil99 Raportdecomprimareridicatpentrucompresor108 Depasiretimpdeschidereusa111 Unitateincorectconfigurata113 Verificatcircuitincalzireelectrica114 Alarmemultiple-Functionareimposibila115 Verificativalvaintreruperepresiuneinalta116 Verificativalvacuplarepresiuneinalta117 AutocomutareDiesel-Electric118 AutocomutareElectric-Diesel120 Verificarecircuitexcitatiealternator121 Verificatcircuitinjectielichid122 VerificarecircuitDiesel/Electric127 Valoaretemperaturanememorata128 AtentionaredepasirementenantarulajDiesel#1129 AtentionaredepasirementenantarulajDiesel#2130 AtentionaredepasirementenantarulajElectric#1131 AtentionaredepasirementenantarulajElectric#2132 Atentionarerulajtotal#1133 Atentionarerulajtotal#2134 Orefunctionarecontroller135 Verificaresemnalintraridigitale136 Verificareiesiridigitalesuplimentaresuplimentare137 Verifcareiesireincalzitormotorclapetadecongelare141 AutocomutaredinDieselinElectricanulata145 Lipsaconfirmaretensiune,contactgeneral146 Nepotrivireversiunisoftware148 AutocomutaredinElectricinDieselanulata149 Alarmaneidentificata150 Inafaraintervaluluidetemperaturapreajos151 Inafaraintervaluluidetemperaturapreasus157 NepotrivireparametriiOptiSet158 EroareincarcareSoftware203 Verificatisenzortemperaturaaeraspirat204 Verificatisenzortemperaturaaerrefulare252 Verificaticircuitadmisieaerproaspat
0 Nuexistaalarme2 Verificatisenzorvaporizator3 Verificatisenzortemperaturaaeraspirat4 Verificatisenzortemperaturaaerrefulat5 Verificatisenzortemperaturaambient6 Verificatisenzortemperaturalichidracire7 Verificatisenzorturatiemotor9 Temperaturaridicatavaporizator10 Presiuneridicatarefulare11 Aparatcontrolatdesenzoralternativ12 Opriredatoritasenzorilorsauintrariidigitale13 Verificatisenzori15 Verificatibujiiincandescentesauincalzitoradmisie17 Porniremotorratata18 Temperaturaridicatalichidracire19 Presiunescazutauleimotor20 Porniremotorratata21 Eroarecircuitracire22 Eroarecircuitincalzire23 Verificarecircuitracire24 Verificarecircuitincalzire25 Verificatialternator26 Verificaticapacitaterefrigerare28 Autotestsaupreliminarcursaanulat29 Verificaticircuitdecongelare30 Clapetadecongelareblocata31 Verificatimartorpresiuneulei32 Capacitatescazutaderefrigerare33 Verificatituratiemotor35 Verificatireleupornire36 MotorElectricnefunctional37 Verificatinivellichidracire38 Cuplareretea380Vincorecta39 Verificatitermostatapa40 Verificatimodfunctionareturatieridicata41 Verificatitemperaturalichidderacire42 Functionareobligatorieturatiejoasa43 Functionareobligatorieinturatiejoasa(Modulatie)44 Verificatisistemdealimentare45 Verificaticircuitulrefulare46 Verificatidebituldeaer48 Verificaticureasauambreiaj50 Programatidatasiora52 Verificaticircuitdeincalzire54 Modautotestexpirat61 Tensiunescazutabaterie62 Decalibrareampermentru63 Motoroprit64 Atentionareautotest65 Diferentatemperaturaanormala66 Nivelscazutuleimotor67 Verificarecircuitelectrovalvalichid68 DefectInterncontroller70 Contororedefect74 Revenirelasetariledefabrica77 EroareEPROM79 Supraincarcaredateinterne80 Senzortemperaturacompresor81 Temperaturaridicatacompresor82 Compresoropritdatoritatemperaturiiexcesive
1. ApasatitastaCLEARpentrustergereauneialarme.
2. AfisajulvarevenilasecventaStandardcandalarmelesuntsterse.
3. ApasatitastaHELPpentruinformatiisuplimentaredepeafisaj.Regasitideasemeneaolistacompletacucodurialarmaincoloanaalaturata.
SIMPLU DE VIZUALIZAT
Vizualizare
SIMPLU DE IDENTIFICAT
Cauzaalarmelor
SIMPLU DE VIZUALIZAT
StergereaCodurilordeAlarma
Pentruinformatiisuplimentare
varugamsacontactaticelmai
apropiatserviceTermoport.
Ghidul utilizatorului Mono - Temperatura
Panou comandaSisteme pentruSemiremorca
NOTA: Pentru informatii suplimentare legate de orice operatiune, va rugam sa consul-tati capitolul respectiv din manualul de utilizare.
2
1
4
6
3
5
7
2
1
4
6
3
5
7
13
2
OFF
ON
MENU6 °C
3SET SENSORSGAUGES
POINT
OFF
ON
MENU6 °C
3SET SENSORSGAUGES
POINT
OFF
ON
MENU6 °C
3SET SENSORSGAUGES
POINT
OFF
ON
MENU6 °C
3SET SENSORSGAUGES
POINT
OFF
ON
MENU6 °C
3SET SENSORSGAUGES
POINT
OFF
ON
MENU6 °C
3SET SENSORSGAUGES
POINT
OFF
ON
MENU6 °C
3SET SENSORSGAUGES
POINT
OFF
ON
MENU6 °C
3SET SENSORSGAUGES
POINTMENU6 °C
3SET SENSORSGAUGES
POINT
.1
PROGRAMMING DEFROST
PLEASE WAIT
MAIN MENU
PRETRIP
NEXTEXIT SELECT BACK
TOTAL RUN TIME HOURS
78NEXTEXIT BACK
3MENUSET SENSORSGAUGES
POINTEXIT
PRETRIPPASS
- EXIT
CURRENT SETPOINT
3 C
++/- TO CHANGE
- NO
NEW SETPOINT WILL BE
4 C
++/- TO CHANGE OK?YES
MENU2 °C
4SET SENSORSGAUGES
POINT
.1
ENGINE RPM
1457NEXTEXIT LOCK
RPM
BACK
ENGINE RPM
1457NEXTEXIT LOCK
RPM
BACKMENU6 °C
3SET SENSORSGAUGES
POINT
.1
1. ApasatitastaON.2. Sevorafisainformatiipentrupornire.3. Candaparatulestegatadepornire
afiseazaosecventacontinandtemperaturaspatiuluidemarfasivaloareadetemperaturaprogramata.
4. AfisajulStandardvaficomutatcatreecranul“TemperatureWatch”dupa2,5minute.Aceastasecventavaafisaaceleasiinformatiidespretemperaturadinspatiuldemarfasivaloaresetata,cucaracteremari.
SIMPLU DE PORNIT
SIMPLU DE PROGRAMAT
CYCLE-SENTRYsauFunctionareContinua
SIMPLU DE PROGRAMAT
SetareValoareTemperatura
SIMPLU DE VERIFICAT
Parametri
DECONGELARE SIMPLA
InitiereManualaaDecongelare
SIMPLU DE ACCESAT
Senzori
SIMPLU DE VERIFICAT
TestPreliminarCursa
SIMPLU DE VERIFICAT
ContorOreFunctionare
1. RevenitilaAfisajulStandard.2. ApasatitastaMODESELECTION.
IMPORTANT: Cu cativa ani in urma, ecranul nu avea posibiltatea de afisare a modului de functionare “Cycle Sentry” sau “Continuous”.
3. DacaaparatulfunctioneazainmodulCycleSentry,simbolul“CycleSentry”apareincoltuldreaptasusalecranului.
4. DacaaparatulfunctioneazainmodulContinuoussimbolulCycleSentrynuvafiafisat.
5. ApasanddinnoutastaMODESELECTIONaparatulvarevenilamodulanteriordefunctionare.
1. Revenitilaafisajulstandard.2. ApasatitastaSETPOINTinsecventa
ecranStandard.3. Apasatitasta+or-pentruaschimba
valoareaafisata.4. ApasatitastaYEScandajungetila
valoareadorita.5. SecventaecranuluiStandardvafi
afisatacunouavaloareprogramata.
1
3
2
4
5
1. Revenitilaafisajulstandard.2. ApasatitastaGAUGES.3. ApasatiBACKsauNEXTpentru
anavigainlistaparametrilor:temperaturalichidracire,nivellichidracire,uleimotor,presiune,amperi,tensiunebaterie,turatiemotor,presiunerefularesauaspiratie,pozitieETV,I/O.Dacanuesteapasatavreotastain30secundeecranulvarevenilasecventastandard.
4. ApasatitastaLOCKpentruafisareaoricaruiparametru15minute.
Apasatidinnoupentrudeblocare.5. ApasatitastaEXITpentrurevenirelaafisajulstandard.
1. Revenitilaafisajulstandard.2. ApasatitastaDEFROST.3. Vorfiafisateinformatiidespre
decongelare.4. VaapareasecventaDecongelare.Va
fiafisatuncursorcarevaindicainprocentetimpulramaspanalafinalizareaprocesului.Canddecongelareaestefinalizataecranulrevinelasecventastandard.
12
1. RevenitilaAfisajulStandard.2. ApasatitastaSENSORS.3. ApasatiBACKsauNEXTpentrua
navigainlistaurmatorilorparametri:temperaturadereferintaaeraspirat,afisaretemperaturaaeraspirat,temperaturadereferintaaerrefulat,afisaretemperaturaaerrefulat,diferentatemperatura,temperaturavaporizator,temperaturaambient,senzorderezerva,inregistratortemperaturasenzori1-6sisenzortemperaturaplacarelee.Dacanuesteapasataniciotastain30
secunde,afisajulvarevenilasecventastandard.4. ApasatitastaLOCKpentruafisareasecventeioricaruisenzorpentru15minute.
Apasatitastadinnoupentruadeblocasecventa.5. ApasatitastaEXITpentrurevenirelaafisajulstandard.
1. Stergeticoduriledealarma.2. Revenitilaafisajulstandard.3. ApasatitastaMENU.4. ApasatitastaNEXTpentruaccesarea
meniuluiPretrip.5. ApasatitastaSELECTpentru
incepereaAutotestuluiPretrip.6. Dacaaparatulnuestepornitvaincepe
unAutotestcomplet.Dacaaparatulfunctioneaza,DieselsauElectric,vafiinitiatunAutotestdefunctionare.
7. Candtoatetestelesuntfinalizate,esteindicatunrezultatcaPASS,CHECKsauFAIL.DacarezultatulesteCHECKsauFAIL,uncoddealarmacorespunzatorvaindicatehnicianuluicauzaproblemelor.
3
1. RevenitilaafisajulStandard.2. ApasatitastaMENU.3. Navigatiinmeniulprincipalprin
apasarearepetataatasteiNEXTsauBACKpanavandvafiafisatmeniulprincipalalcontoruluideore.
4. ApasatitastaSELECTpentruaintrainmeniulContorOre.
5. ApasatitastaNEXTsauBACKpentruavizionasecventeleContorOre.
2
NOTA: Pentru informatii suplimentare legate de orice actiune, va rugam sa consultati capitolul respectiv din manualul de utilizare.
NOTA: Trebuie sa apasati YES in zece secunde de la selectarea noii valori de tempera-tura, altfel selectarea va fi anulata.
45 3 3
2
1
3
1
4
1
3
4
2 & 5
3
12
4
2
1
45 3 3 3 & 5
2
1
5
7
4
2
3
3
4
5
2
1