214
Series VENTS VOK
J ApplicationsExhaust ventilation system for various premises for roof mounting. Compatible with Ø 200 to 500 mm round air ducts.
J DesignThe fan casing is made of steel with polymeric coating.
J MotorThe impellers are powered with two- or four-pole, sin-gle phase asynchronous motors with external rotor and built-in thermal overheating protection with automatic restart depending on the model. Ball bearings in the motor ensure long service life. Motor protection rating IP 44.
J Speed controlBoth smooth or step speed control is performed by means of the thyristor or autotransformer controller. Several fans can be connected to one controller under condition that the total power and operating current do not exceed the rated controller values.
J MountingThe fan is mounted on the roof directly above the ventilating duct or shaft and is firmly fixed to the flat surface by means of a connecting plate. While mounting VOK fans directly onto the flat roof a supporting block shall be provided to prevent water and snow drops into the vent of the ventilation shaft. Electrical connection and installation shall be performed in compliance with the manual and circuit diagram on the terminal box.
AXIAL ROOF FANS
Accessories
TypeDimensions [mm] Weight
[kg]D D1 H L L1
VOK 2Е 200 208 345 280 425 330 5.0
VOK 2Е 250 262 405 280 425 330 7.0
VOK 4Е 250 262 405 280 425 330 7.0
VOK 2Е 300 314 555 340 585 450 10.5
VOK 4Е 300 314 555 340 585 450 10.5
VOK 4Е 350 364 555 350 655 535 12.0
Motor modification
Number of poles Phase
24
E: single phase
Series
VENTS VOK
Impeller diameter
200; 250; 300; 350
Designation key
Technical data
Fan overall dimensions
Axial roof fans with the air capacity up to 2500 m3/h
in the steel casing with the horizontal exhaust of air
ErP dataOverall efficiency ƞ, [%]
Measurement category MC
Efficiency category EC
Efficiency grade N
Variable speed drive VSD
Power [kW]
Current [A]
Air flow [m3/h]
Static pressure [Pa]
Speed [n/min-1]
Specific ratio SR
VENTS. Industrial and commercial ventilation | 02-2016
page 378 page 378 page 442 page 446 page 461 page 462 page 466 page 467page 211
VOK 2E 200* VOK 2E 250* VOK 4E 250* VOK 2E 300 VOK 4E 300* VOK 4E 350
Voltage [V] 1~ 230
Frequency [Hz] 50 60 50 60 50 60 50 60 50 60 50 60
Power [W] 55 61 80 91 50 56 145 178 75 92 140 147
Current [A] 0.26 0.28 0.4 0.42 0.22 0.24 0.66 0.79 0.35 0.4 0.65 0.66
Max. air flow [m3/h] 860 875 1050 1150 800 865 2230 2280 1340 1475 2500 2650
RPM [min-1] 2300 2550 2400 2990 1380 1730 2300 2410 1350 1405 1380 1700
Noise level at 3 m [dBA] 50 51 60 61 55 56 60 61 58 59 62 63
Max. transported air temperature [°C] -30...+60 -30...+50 -30...+60 -30...+50 -30...+60 -30...+50 -30...+60 -30...+50 -30...+60 -30...+50 -30...+60 -30...+50
Protection rating IP 24 (VKF IPX4)
* Compliant to the ErP-regulation (EC) 327/2011, the power consumption at optimum efficiency is < 125W.
215
WWW.VENTILATION-SYSTEM.COM
VENTS. Industrial and commercial ventilation | 02-2016
VENT
S VOK
FAN
SERI
ES
VENTS VOK VENTS VOK
VENTS VOK VENTS VOK
Pre
ssur
e, ∆
P [P
a]
Pre
ssur
e, ∆
P [P
a]
Pre
ssur
e, ∆
P [P
a]
Pre
ssur
e, ∆
P [P
a]
Pres
sure
, ∆P
[in W
G]
Pres
sure
, ∆P
[in W
G]
Pres
sure
, ∆P
[in W
G]
Pres
sure
, ∆P
[in W
G]
Air Flow, [CFM] Air Flow, [CFM]
Air Flow, [CFM] Air Flow, [CFM]
Air Flow, [m3/h] Air Flow, [m3/h]
Air Flow, [m3/h] Air Flow, [m3/h]
118 218 318 418 518
0
0.1
0.2
0.3
0.4
0
20
40
60
80
100
200 300 400 500 600 700 800 900
118 218 318 418 518 618
0
0.1
0.2
0.3
0.4
0.5
0.6
0
20
40
60
80
100
120
140
200 400 600 800 1000 1200
234 434 634 834 1034 1234
0
0.1
0.2
0.3
0.4
0.5
0.6
0
20
40
60
80
100
120
140
400 800 1200 1600 2000 2400
Ƞmax
471 671 871 1071 1271 1471
0
0.1
0.2
0.3
0.4
0.5
0
20
40
60
80
100
120
140
800 1200 1600 2000 2400 2800
Ƞmax
VOK 2E 20050 Hz60 Hz
VOK 2E 250 VOK 4E 250
VOK 2E 300 VOK 4E 300
50 Hz60 Hz
50 Hz60 Hz
50 Hz60 Hz
50 Hz60 Hz
VOK 4E 35050 Hz60 Hz