Document Part Number 9050-0520
DOLBYDIGITAL / AC-3ENCODING USING THE
ARGUS
ENCODER
-
8/2/2019 Vela Momentum User Manual
2/16
-
8/2/2019 Vela Momentum User Manual
3/16
Contents
Introduction .................................................................................... 5
Getting Started ............................................................................................ 5
Dolby Parameter Control Application ........................................... 6
Configuration Control Property Page ....................................................... 6
Dolby Enabled ................................................................................................. 6Time Code Start .............................................................................................. 6
Start Delay ....................................................................................................... 7
Data Rate ........................................................................................................ 7
Figure 1. Configuration Control Property Page ....................................................... 7
Sample Rate .................................................................................................... 8
Audio Coding Mode ......................................................................................... 8
Audio Bandwidth .............................................................................................. 8
Bit Stream Mode.............................................................................................. 8
Coupling Frequency ........................................................................................ 8
Dialog Normalization ....................................................................................... 9
Dialog Normalization Channel 2 ..................................................................... 9
Enable Low-Frequency Effects ....................................................................... 9
Bitstream Info Property Page..................................................................... 9
Center Mix Level ............................................................................................. 9
Surround Mix Level ......................................................................................... 9
Dolby Surround Mode ................................................................................... 10
Copyright Bit .................................................................................................. 10
Original Bit Stream ........................................................................................ 10
Info Exists ...................................................................................................... 10
Mix Level ........................................................................................................ 10
Figure 2. Bitstream Info Property Page ................................................................. 10
Room Type ..................................................................................................... 11
Channel 2 Info Exists, Channel 2 Mix Level, Channel 2 Room Type ........... 11
Preprocessing Property Page .................................................................. 11
Digital De-emphasis ...................................................................................... 11
DC High-pass Filter ....................................................................................... 11
-
8/2/2019 Vela Momentum User Manual
4/16
Bandwidth Low-pass Filter ............................................................................ 11
LFE Low-pass Filter ...................................................................................... 12
90-Degree Phase Shift .................................................................................. 12
3 dB Attenuation ............................................................................................ 12
Figure 3. Preprocessing Property Page ................................................................ 12
Compression Characteristic .......................................................................... 13
RF Overmodulation Protection ..................................................................... 13
Input/Output Property Page ..................................................................... 13
Input Channel Assignments .......................................................................... 13
Figure 4. Input/Output Property Page .................................................................... 13
Output Mode .................................................................................................. 14
Stream Number ............................................................................................. 14
Time Codes ................................................................................................... 14
Audio Output .................................................................................................. 14
File Format .................................................................................................... 14
Playback Clock Source ................................................................................. 14
Block Diagram ........................................................................................... 14
Typical Installation .................................................................................... 14
Figure 5. AC-3 Encoder Block Diagram ................................................................. 15
Figure 6. Typical Installation Layout ....................................................................... 15
Contents (Cont)
Rev. 0, Feb 2002Copyright 2002, Vela LP
-
8/2/2019 Vela Momentum User Manual
5/16
Dolby Digital / AC-3
Encoding Using theArgus Encoder
IntroductionThe ability to encode an Dolby Digital/AC-3 stream in addition to the
standard MPEG audio and video streams is an optional feature availablewith Velas Argus software release 2.6.1 and later.
The Momentum-designed Opus encoder board, which the Argus usesfor Dolby Digital/AC-3 encoding, is a 24-bit multi-channel digital audio
processor for the PCI bus. Among its features are the following:
Four stereo digital (AES) inputs
One stereo digital audio output
SMPTE time code input
80 MHz, 24-bit digital signal processors (DSPs) High-speed PCI bus
Standard Dolby Digital 5.1 encode program
AES/EBU or S/PDIF digital audio I/O formats
RS-422 interface
Included audio input/output cable
A comprehensive software application accompanies the encoder boardto complete the Dolby Digital/AC-3 encoding solution for the Argus.
A block diagram of the system can be found in Figure 5. A drawing that
shows the Momentum board in a typical Argus encoder configuration iscan be found in Figure 6.
Getting Started
In order to maximize your use of the Dolby Digital/AC-3 encodingsolution for the Argus, you must first:
Install the Momentum encoder board in an unused PCI slot.
Argus is a registered trademark of Vela LP. Dolby is a trademark of Dolby Laboratories.All other trademarks, brand names, or product names appearing in this publication areregistered to the respective companies or organizations that own the names or trademarks.
-
8/2/2019 Vela Momentum User Manual
6/16
Dolby Digital / AC-3 Encoding Using the Argus Encoder6
Connect the supplied input/output cable to the boards D-connector.
Install the software for the Momentum Dolby Digital/AC-3
encoder, making sure that the Momentum microcode is located inthe directory from which the FMTestApp (or EDL Editor) applica-
tion is run. The Momentum microcode is comprised of three files:
enc13.cld, enc23.cld, and enc33.cld.
Before starting the application, make certain that the registry keyHKEY_CURRENT_USER\Software\Vela Research\Broadcast
Argus\EncoderConfig\AC3Installed is set to 1.
Before cueing for an encode, use the Dolby Parameter Control
Application to activate Dolby Digital/AC-3 encoding and to set allof the Dolby-related parameters.
Dolby Parameter Control ApplicationMost of the parameters related to Dolby Digital/AC-3 encoding can be
set using the Dolby Parameter Control Application. The one notable ex-
ception to this rule is the setting of the PID when the Dolby Digital/AC-3 stream is to be included in a transport stream. The Dolby PID is set
using the Mux property page of RegCtrlPnl.
The Dolby Parameter Control Application has four property pages:
Configuration Control, Bitstream Info, Preprocessing, and Input/Output.
Configuration Control Property Page
It is from the Configuration Control property page (Figure 1) that you
turn Dolby Digital/AC-3 encoding on or off and that you set the bit rate
and sample rate of the AC-3 stream. The following properties are repre-sented on the Configuration Control page:
Dolby Enabled
Check this checkbox if and only if you wish to include a Dolby Digital/AC-3 stream in the next encoded file.
Time Code Start
Check this checkbox if and only if you wish to use the mark-in and mark-out
of the VTR component to control the start and stop of the next Dolby Digital/AC-3 encode. Several requirements must be met in order to use this option:
1. VTR control must be enabled. Use the VTR Control page on the EDL
Editor or the VTR property page on RegCtrlPnl to enable VTR control.
-
8/2/2019 Vela Momentum User Manual
7/16
Dolby Digital / AC-3 Encoding Using the Argus Encoder 7
2. The Momentum board must be supplied with a time-code input signal.For example, the time-code-out of the tape deck might be connected
to the time-code-in cable supplied with the Momentum encoder.
3. The mark-in and mark-out supplied through the EDL Editor or through
RegCtrlPnl must be valid time codes that will be provided to the
Momentum encoder by the time-code generator.
4. Prior to the encode, the tape must be pre-rolled to a point well ahead of
the mark-in.
Start Delay
The numeric value in this field specifies the number of milliseconds thatthe Argus encoder will wait after starting the Momentum encoder before
starting the IBM audio and video encoders. The default value is 75 msec.
A negative value may be provided. If the value is negative, the IBM au-dio and video encoders will be started before the Momentum
encoder is started. This value can be adjusted to guarantee propersynchronization of the video and Dolby Digital/AC-3 content.
Data Rate
This field specifies the speed in kilobits per second at which the Dolby
Figure 1. Configuration Control Property Page
-
8/2/2019 Vela Momentum User Manual
8/16
Dolby Digital / AC-3 Encoding Using the Argus Encoder8
Digital/AC-3 data will be transmitted. Values range from 32 kbps to 640
kbps. Data rates that are supported by the encoder depend on the selected
audio coding mode (see below). Generally speaking, the fewer the chan-nels included in the bit stream, the lower the data rate.
Sample Rate
The sample rate field specifies the transmission frequency of the Dolby
Digital/AC-3 bit stream. Because the Momentum encoder does not
include a sample rate converter, you should in most cases check theAuto checkbox next to the sample rate field, thereby slaving the sample
rate to that of the input signal.
Audio Coding Mode
This field specifies the number and configuration of full-bandwidth au-
dio channels to be encoded within the AC-3 bit stream. The audio coding
mode is designated as two numbers, m and n, where m is the number offront channels and n is the number of rear (or Surround) channels. The
exception to this notation is the 1+1 selection, representing dual-mono,
where two completely separate channels are included in the bit stream.
Audio Bandwidth
The bandwidth of the audio is adjusted automatically by the Momentumencoder, which usually maintains the full audio spectrum bandwidth of
20 kHz. In some cases, however, especially where the audio data rate is
decreased to an exceptionally low value, it may be useful to decrease theaudio bandwidth as well. The optimum choice of audio bandwidth
depends on both the audio coding mode and the data rate. In most cases,
you should allow the encoder to adjust the audio bandwidth automati-
cally (just check the Auto checkbox).
Bit Stream Mode
This parameter identifies the type of service that the Dolby Digital/AC-3bit stream conveys. Its setting does not affect the encoding process, but
merely provides vendor-specific information to the decoder.
Coupling Frequency
This parameter identifies the frequency at which the encoder starts touse high-frequency channel coupling. The setting is ignored if theaudio coding mode is 1+1 or 1/0. In most cases, you should allow the
encoder to adjust the coupling frequency automatically (just check
the Auto checkbox).
-
8/2/2019 Vela Momentum User Manual
9/16
Dolby Digital / AC-3 Encoding Using the Argus Encoder 9
Dialog Normalization
This parameter allows for uniform reproduction of spoken dialog when
decoding any AC-3 bit stream. Its value indicates how far the subjectivedialog level of the encoded program falls below digital 100% full scale
(0 dBFS). The setting (between -1 and -31 dB) is not used directly by theDolby Digital/AC-3 decoder, but is used by a section of the sound repro-
duction system to set the audio reproduction volume.
Dialog Normalization Channel 2
This parameter serves the same purpose as the Dialog Normalizationsetting, described above; however, it applies to the second channel of a
dual-mono bit. It is ignored if the audio coding mode is not 1+1.
Enable Low-Frequency Effects
This setting enables or disables the optional low-frequency effects chan-
nel. This LFE channel of limited bandwidth (
-
8/2/2019 Vela Momentum User Manual
10/16
Dolby Digital / AC-3 Encoding Using the Argus Encoder10
Dolby Surround Mode
This setting specifies whether or not a two-channel Dolby digital bit stream
is conveying a Dolby Surround encoded program. This parameter
appears in the bit stream only when the audio coding mode is set to 2/0.
Copyright Bit
The setting of this checkbox indicates whether or not the included audio
content is protected by copyright.Original Bit Stream
The setting of this checkbox specifies whether the AC-3 content is an
original bit stream (checked) or just a copy of the original (unchecked).
Info Exists
This setting specifies whether or not audio production information(mixing level and room type) exist within the AC-3 bit stream.
Mix Level
Active only when the Info Exists checkbox is checked, this setting indi-
cates the absolute acoustic Sound Pressure Level (SPL) of an individual
channel (usually the center channel dialog level) during the final audio
Figure 2. Bitstream Info Property Page
-
8/2/2019 Vela Momentum User Manual
11/16
Dolby Digital / AC-3 Encoding Using the Argus Encoder 11
mixing session. The peak mixing level, ranging from 80 to 111 dB SPL,
is the acoustic level of a sine wave in a single channel whose peak reaches
digital 100% full scale (0 dBFS) in the PCM representation. The absoluteSPL is typically measured using pink noise at -20 or -30 dB RMS with
respect to the peak RMS sine wave level. The Mix Level value is not
normally used within the Dolby Digital decoder, but may be used by
other elements in an audio system. This setting appears in the stream
only when the Info Exists checkbox is checked.
Room Type
This setting indicates the type and calibration of the room used for the finalaudio mixing session. It is not normally used within the Dolby Digital
decoder, but may be used by other elements in an audio system. This setting
appears in the stream only when the Info Exists checkbox is checked.
Channel 2 Info Exists, Channel 2 Mix Level, Channel 2 Room Type
These settings all apply to the second channel in a dual-mono bit streamwhen the audio coding mode is set to 1+1. They are ignored if the audio
coding mode is not 1+1. Please refer to the descriptions of Info Exists,
Mix Level, and Room Type, above, for a complete description of each ofthese parameters.
Preprocessing Property Page
The settings on the Preprocessing property page (Figure 3) control themanner in which the incoming PCM data is processed before being sent
to the encoding algorithm.
Digital De-emphasisWhen an incoming PCM signal has been digitally emphasized, it is
usually advisable to de-emphasize that signal before encoding it. If you
check the Auto checkbox, the AC-3 encoder will decide, based on theincoming audio, whether or not to apply de-emphasis.
DC High-pass Filter
This checkbox either enables (checked) or disables a DC filter for all
input channels.
Bandwidth Low-pass Filter
This checkbox either enables (checked) or disables a low-pass filter forall input channels.
-
8/2/2019 Vela Momentum User Manual
12/16
Dolby Digital / AC-3 Encoding Using the Argus Encoder12
LFE Low-pass Filter
This setting is used to activate a 120 Hz low-pass filter applied to the LFE
input channel. If the digital signal fed to the LFE input does not contain
information above 120 Hz, you may disable this filter.
90-Degree Phase Shift
This feature is used to generate multichannel AC-3 bit streams that maybe down-mixed in an external two-channel decoder to create an output
that is truly compatible with Dolby Surround.
3 dB Attenuation
This setting applies a 3 dB cut to the Surround channels of a multi-
channel film sound track when it is being transferred onto a formatfor consumer home theater playback. This feature is available because
cinema sound track Surround channels are mixed 3 dB hot relative
to the front channels in order to account for cinema amplifier gains.Home theater Surround gains are calibrated differently, thus
requiring a -3 dB adjustment to the Surround tracks.
Figure 3. Preprocessing Property Page
-
8/2/2019 Vela Momentum User Manual
13/16
Dolby Digital / AC-3 Encoding Using the Argus Encoder 13
Figure 4. Input/Output Property Page
Compression Characteristic
This setting specifies the characteristic curve of the Dynamic Range
Compression algorithm. If the compression characteristic setting is enabledduring the encode, a Dolby decoder will refer to this setting to reduce the
audio program's dynamic range. Available selections for this parameterinclude Film Standard, Film Light, Music Standard, Music Light, and Speech.
RF Overmodulation Protection
This setting determines whether or not a RF preemphasis filter is used to
prevent RF over-modulation in set-top-box decoders.
Input/Output Property PageThe Input/Output property page allows you to control parameters directly
related to the incoming and outgoing digital signals. See Figure 4.
Input Channel Assignments
The six controls in the left-most column (labeled Input Channel Assign-ments) allow you to associate each of the six input channels with a specific
channel of the source audio (left, right, center, left Surround, right Surround,
and LFE). If the audio coding mode does not identify the channel as an activeinput, then the channel assignment is ignored.
-
8/2/2019 Vela Momentum User Manual
14/16
Dolby Digital / AC-3 Encoding Using the Argus Encoder14
Output Mode
The data signal sent by the encoder has an information field specifying
what format the data is in. The options are: (1) Consumer-Professional32-bit, (2) Professional 16-bit channel 1, and (3) Professional 16-bit
channel 2. A Dolby Digital/AC-3 decoder will use this value in a vendor-specific manner.
Stream Number
This setting specifies the data stream number to be inserted into the
preamble of the IEC958 AC-3 output data. The valid range for thisparameter is 0 through 7, with a default value of 0.
Time Codes
This settings specifies whether or not SMPTE time code packets are to be
included in the encoder output.
Audio Output
This parameter determines the value of bit 1 (the audio/non-audio bit) of
the channel status information contained in the IEC958 output. Annex B
of ATSC A/52 recommends setting this bit to 1 (non-audio data) inprofessional mode to indicate the presence of AC-3 data within the IEC
958 interface. The bit must be set to 1 in the consumer mode.
File Format
This parameter is used in determining the format of recorded disk files.
Playback Clock Source
This parameter determines the source of the master audio clock during
playback from a disk file. When this parameter is set to Internal Synchro-nization (0), the encoder will use one of the on-board oscillators,matching the detected sampling frequency of the disk file. When the clock
source parameter is set to External Synchronization (1), the encoder uses
the recovered clock from the digital input signal.
Block Diagram
The illustration in Figure 5 shows system flow within the Dolby Digital/
AC-3 encoder, the system PCI bus, and the Vela Argus encoder.
Typical Installation
Figure 6 shows the Momentum Opus Dolby Digital/AC-3 encoder board
as typically installed in a Vela Argus rack-mount encoder system.
-
8/2/2019 Vela Momentum User Manual
15/16
Dolby Digital / AC-3 Encoding Using the Argus Encoder 15
Figure 5. AC-3 Encoder Block Diagram
Figure 6. Typical Installation Layout
-
8/2/2019 Vela Momentum User Manual
16/16
Broadcast Products Division
404 West Ironwood DriveSalt Lake City, UT 84115801-464-1600
OEM Products Division
5733 Myerlake CircleClearwater, FL 33760727-507-5300
www.vela.com