Download - Veka evolutions 2015
Topics of DiscussionTopics of Discussion
• Code Requirements
• Design Progression
• Performance
• System Overview
• Code Requirements
• Design Progression
• Performance
• System Overview
Presentation OverviewPresentation Overview
Code TrackingCode Tracking
Residential – IRC, HUD, AAMA 101
Commercial – IBC, AAMA 101
Windspeeds – ASCE 7-10
Energy – IECC,IgCC, ICC 700, ASHRAE 189
Government – Energystar, ARRA, Homestar, Building Star, R5 Volume Purchase
Niche Markets – Sound Control
State & Local Codes – SEAAMA states - i.e. Florida and Texas
Researches – i.e. University of Florida, IBHS
Residential – IRC, HUD, AAMA 101
Commercial – IBC, AAMA 101
Windspeeds – ASCE 7-10
Energy – IECC,IgCC, ICC 700, ASHRAE 189
Government – Energystar, ARRA, Homestar, Building Star, R5 Volume Purchase
Niche Markets – Sound Control
State & Local Codes – SEAAMA states - i.e. Florida and Texas
Researches – i.e. University of Florida, IBHS
Code RequirementsCode Requirements
Energy Star* Energy Star* ResidentialResidential 0.270.27
Lowest ULowest USpecifying AgencySpecifying Agency PurposePurpose
Passive HousePassive House ResidentialResidential
* Next revision of Energy Star in Jan. 2015 - .27 in North and .40 in South* Next revision of Energy Star in Jan. 2015 - .27 in North and .40 in South
<0.2<0.2
ASHRAE 189ASHRAE 189 CommercialCommercial 0.250.25
IgCCIgCC 0.260.26ResidentialResidential
Volume Purchase Most Efficient?Volume Purchase Most Efficient?
U.S. D.O.E. / E.P.A.U.S. D.O.E. / E.P.A. 0.200.20ResidentialResidential
ENERGY STAR Qualification CriteriaCANADA Windows & Doors
ENERGY STAR Qualification CriteriaCANADA Windows & Doors
Design ProgressionDesign Progression
Step 1. Step 1. Optimize Standard Sash, Redesign profile to 1 3/8” I.G.Optimize Standard Sash, Redesign profile to 1 3/8” I.G.
1 3/8” I.G.1 3/8” I.G.
Standard SashStandard Sash
Design ProgressionDesign Progression
Step 2. Step 2. Redesign double hung frame with 3/4” balance pocket to compensate for larger sash weight and commercial sizes
Redesign double hung frame with 3/4” balance pocket to compensate for larger sash weight and commercial sizes
Design ProgressionDesign Progression
Step 3. Step 3. Increase sash chamber size to accomodate commercial reinforcement
Increase sash chamber size to accomodate commercial reinforcement
Design ProgressionDesign Progression
Step 4. Step 4. Lengthen glazing tower and add double wall to improve cycle testing and allow for misalignment of glass testing
Lengthen glazing tower and add double wall to improve cycle testing and allow for misalignment of glass testing
Double wallDouble wall
Design ProgressionDesign Progression
Step 5. Step 5. Add height to sash tower on sloped sill to increasewater penetration
Add height to sash tower on sloped sill to increasewater penetration
2 7/
8”2
1/2”
Design ProgressionDesign Progression
Step 6. Step 6.
Add Triple WeathersealAdd Triple Weatherseal
BeforeBefore
Sash In-fill SolutionsSash In-fill Solutions
1.) Urethane Foam1.) Urethane Foam 2.) Wire Cut Foam2.) Wire Cut Foam
3.) Aluminum3.) Aluminum
4.) Steel4.) Steel
5.) Fiberglass5.) Fiberglass6.) Thermal Break Aluminum6.) Thermal Break Aluminum
7.) Glass Filled PVC7.) Glass Filled PVC
9.) Rigid Foamed PVC9.) Rigid Foamed PVC
8.) Multi-Chambered PVC8.) Multi-Chambered PVC
Sash In-fill Solutions - (Overall Impact)Sash In-fill Solutions - (Overall Impact)
1.) Urethane Foam
2.) Wire Cut Foam
3.) Aluminum
4.) Steel
5.) Fiberglass
6.) Thermal Break Alum.
7.) Glass Filled PVC
8.) Multi-Chambered PVC
9.) Rigid Foamed PVC
1.) Urethane Foam
2.) Wire Cut Foam
3.) Aluminum
4.) Steel
5.) Fiberglass
6.) Thermal Break Alum.
7.) Glass Filled PVC
8.) Multi-Chambered PVC
9.) Rigid Foamed PVC
Impact on U-ValueImpact on U-Value Impact on StrengthImpact on Strength Impact on CostsImpact on Costs
Approved 3rd Party Supplied VEKA Supplied
Key Benefits of The DesignKey Benefits of The Design
VEKA evolutions™ is comprised of the essential elements of performance. Meaning, when you add specific glazing packages to the finished window, it can take on the benefits of being Impact Rated, Sound Control rated, Low Solar Gain and Low Heat Transfer. Also, protection from the elements, heat, cold, wind, and water.
VEKA evolutions™ is comprised of the essential elements of performance. Meaning, when you add specific glazing packages to the finished window, it can take on the benefits of being Impact Rated, Sound Control rated, Low Solar Gain and Low Heat Transfer. Also, protection from the elements, heat, cold, wind, and water.
Impact ResistanceImpact Resistance
CommercialCommercial
Sound ControlSound Control
ResidentialResidential
Green InitiativesGreen Initiatives
Energy SavingsEnergy Savings
Double-Hung Performance OptionsDouble-Hung Performance Options
1" Triple Glazed (1/8" Low-E || Argon || 1/8" || Argon || Low-E 1/8")
1-1/4" Triple Glazed (1/8" Low-E || Krypton || 1/8" || Krypton || Low-E 1/8")
1-3/8" Quad Glazed (1/8" Low-E || Krypton || 1/8" || Krypton || 1/8" || Krypton || Low-E 1/8")
1" Triple Glazed (1/8" Low-E || Argon || 1/8" || Argon || Low-E 1/8")
1-1/4" Triple Glazed (1/8" Low-E || Krypton || 1/8" || Krypton || Low-E 1/8")
1-3/8" Quad Glazed (1/8" Low-E || Krypton || 1/8" || Krypton || 1/8" || Krypton || Low-E 1/8")
u = 0.21 SHGC = 0.30 R5
u = 0.17 SHGC = 0.30 R6
u = 0.14 SHGC = 0.30 R7
u = 0.21 SHGC = 0.30 R5
u = 0.17 SHGC = 0.30 R6
u = 0.14 SHGC = 0.30 R7
Laminated IG (1/8" Annealed || 1/4" Laminated)
Double Laminated IG (1/4"Laminated ¦ 1/4" Laminated
Laminated IG (1/8" Annealed || 1/4" Laminated)
Insulated IG (1/8" || 3/16" Annealed) 1/8" Low-E || Krypton || 1/8" || Krypton || 1/8" || Krypton || Low-E 1/8")
Laminated IG (1/8" Annealed || 1/4" Laminated)
Double Laminated IG (1/4"Laminated ¦ 1/4" Laminated
Laminated IG (1/8" Annealed || 1/4" Laminated)
Insulated IG (1/8" || 3/16" Annealed) 1/8" Low-E || Krypton || 1/8" || Krypton || 1/8" || Krypton || Low-E 1/8")
STC = 34
STC = 38
LC50 - 54" x 76”
CW30 - 56" x 91" CW80 - 54" x 76"
STC = 34
STC = 38
LC50 - 54" x 76”
CW30 - 56" x 91" CW80 - 54" x 76"S
truc
tura
lIm
pact
Sou
nd C
ontr
olE
nerg
y S
avin
gs
System OverviewSystem Overview
Phase 1 - Operator TypesPhase 1 - Operator Types
Double Hung
Double Hung
Sideload (SH)
Sideload (SH)
Casement / Awning
Casement / Awning
Single Hung
Single Hung
PicturePicture SliderSlider
Patio Door, Double SliderPatio Door, Double SliderPhase 2 - Phase 2 -
Design FeaturesDesign Features
Integral Interlock & Lift Rail
Integral Interlock & Lift Rail
Larger sash pockets for multiple infill and reinforcing
Larger sash pockets for multiple infill and reinforcing
Extended sloped sill tower for superior water performance
Extended sloped sill tower for superior water performance
13/8” Setback Integral Nail Fin
13/8” Setback Integral Nail Fin
7/8” Accessory Groove for fin adjustment
7/8” Accessory Groove for fin adjustment
3/4” Balance Pocket for heavier sash
weight Integral Nail Fin
3/4” Balance Pocket for heavier sash
weight Integral Nail Fin
13/8” Glazing pocket to accommodate triple
& quad glazed
13/8” Glazing pocket to accommodate triple
& quad glazed
31/4” Depth of Frame31/4” Depth of Frame