Download - Vca® b tips - Duke University
VersaCare® Bed TipsFlexAFoot™ MechAnisM• Allowsthecaregivertocustomizetheoveralllengthofthebedandsleepsurfacetofitthepatient.
• Thebedandsurfacecanberetractedupto11"(28cm)whichalsoaidsthecaregiverduringtransport(i.e.smallelevators,smallerturningradius).
• Designedtohelpreducepatientmigrationtothefoot-endofthebed.
• IntegratedsurfaceautomaticallyadjuststothelengthofthebedasFlexAfoot™mechanismisactivated.
To AcTivATe:
• PressandholdthefootShortercontroltoretractthefootsection.
• PressandholdthefootLongercontroltoextendthefootsection.
lowchAir® Position• Allowsthepatienttobeplacedintoachairposition,whilemaintaininglowheight.
To AcTivATe:
• Setthebrake.
• PresstheEnable ControlandthentheChairbutton.
onesteP® cPr & eMergency trendelenburg• Ifusinganintegratedairsurface(VersaCareA.I.R.®orVersaCare®P500),thesurfaceautomaticallygoesintoMaxInflatefor30minutes.After30minutes,thesurfacewillgointoNormal/Standardmode.
• Acardiacarrestboardisrequired.Theheadboardcanbeusedinplaceofthecardiacarrestboard.
To AcTivATe cPR:
• Pullandholdthehandle.
• Holdthehandleuntiltheheadandkneesectionscometoastopintheflatpositionandthefootsectionstopsraising.
• Releasethehandle.
To AcTivATe emeRgency TRendelenbuRg:
• Pullandholdthehandle.
• Holdthehandleuntiltheheadandkneesectionscometoastopintheflatpositionandthefootsectionstopsraising.
• Continuetoholdthehandleuntilthedesiredangleisreached(upto15°).
PAtient rePositioning• Twoeasywaystohelpmaintainpatientpositioning:
+ PatientHipIndicators–locatedonbothsidesofthebedtoshowyouwherethepatient’shipsbelong.
+ FlexAfoot™Mechanism–allowsforcustomizedbedlengthsothefootboardcanberetracted/extendedupto11".Thisright-sizesthebedtopreventpatientsfromslidingdowninbed.
PAtient rePositioning – boost® Function• Ifyourpatientneedstoberepositioned,usetheBoost®featuretomakeiteasierforyoubyplacingthebedintheidealpositiontorepositionyourpatient.
• PressingtheBoost®buttonwill:+ MaxInflatethemattress.
+ Flattenthebed.
+ Putthebedattheidealworkingheight.
+ Placethebedin7degreesReverseTrendelenburg.
To AcTivATe:+ PresstheBoost®buttononthesiderail.
To deAcTivATe:+ Pressthebedflatbuttontoreturnthebedtoflatposition.
bed exit AlArM – 3 Mode PAtient Position Monitor• Thebedexitalarmwillnotifythecaregiverwhen:
+ Out of Bed:patient’sweightshiftssignificantlyofftheframeofthebed.
+ Exiting:patientmovesawayfromthecenterofthebedtowardsanegresspoint.
+ Patient Position: patientmovestowardeithersiderailormovesawayfromtheheadsection,suchassittingupinbed.
To AcTivATe:
• Ensurepatientisonthebed.
• Presstheenablecontrol.
• Pressthedesiredmodecontrol.Whenthesystembeepsonetimeandtheindicatorstaysonsolid,thesystemisarmed.
To deAcTivATe:
• PresstheEnable Control.
• Pressthedesiredmodecontrol.Whenthesystembeepsonetimeandtheindicatorlightisgone,thesystemisdeactivated.
Zeroing the scAle• Thescaleshouldbezeroedpriortoplacingapatientonthebed.
• BesuretoputALLlinens,pillows,andequipmentonthebedpriortozeroingthescale.
How To ZeRo THe ScAle:
• PresstheEnable Control.
• PressandholdtheZero Control until00.0isshown(HOLDwillbedisplayeduntil00.0isshown)andthenreleasethecontrol.
• NOTE:Afterreleasingthecontrol,thescaledisplaywillshow‘CALC’.Donottouchthebeduntilthedisplaystopsflashing‘CALC’andshows0.0.
weighing A PAtient• Besurethescalehasbeenzeroedwithlinens,pillows,andotherequipmentonthebedpriortoweighingthepatient.
How To weigH A PATienT:
• Makesurethepatientiscenteredonthebed.
• Ensurethebedisclearofallobstructions(lines,tubing,walls,etc).
• Presstheweighbutton.
• Onreleaseoftheweighcontrol,thebedgetsthecurrentpatient’sweight.Itisshowninlbfor10seconds,thenkgfor5secondsandthenrepeats.
obstAcle detect® FeAture• TheObstacleDetectsystemrunsalongthethreeopensidesofthebedframe.
• Thesystemrecognizesobjectsthatarebetweentheupperframeandthebaseframe.
• Ifanobjectisidentifiedwhilethebedsleepdeckislowering,thebedwill:
+ Stoplowering.
+ Raiseautomaticallyfor2seconds.
+ Bednotdownindicatoronbothsidesofthebedwillflash.
VAsculAr Position• Allowsforthepatient’slegstobeplacedabovetheleveloftheirsternum.
To AcTivATe:
• Lowertheheadsectiontothedesiredposition.
• Raisethekneesectiontothedesiredposition.
• UsetheTrendelenburgcontroltopositionthesleepdecktothedesiredposition.
To deAcTivATe:
• UsetheReverseTrendelenburgcontroltoreturnthebedframetothehorizontalposition.
• Usethebedflattoreturnthesleepdecktotheflatposition.
hAndsFree® Foot PedAls• Footpedalsallowthecaregivertoraiseandlowertheheadofthebedandtheheightofthebedwithoutusingtheirhands.
To AcTivATe:
• Stepdownonanypedalfor1-3seconds.
• Releasethepedal.
• Stepdownonthepedalofthedesiredfunctionuntilthedesiredfunctionisachieved.
lockout controls• Locatedonthecaregiversiderailcontrolpanel,thelockoutcontrolsallowthecaregivertodisablethebedarticulatingfunctionstopreventpatientpositioningfeaturesfrombeingused.
• Featuresthatcanbelockedout:
+ Bedhigh/low.
+ Headup/down.
+ Kneeup/down.
+ Adjustablebedlength.
To AcTivATe:
• SimultaneouslypresstheLockbuttonandthespecificlockoutcontroldesired(eitherupordown).
• Bothpatientandcaregivercontrolsarelockedout.
• Anaudiblealarmsoundswhenalockoutisactivated.
• Anamberlightwillilluminateonthelockforthefeaturethatyouwantlockedout–thissignifiesthatthefeatureislockedout.
To deAcTivATe:
• SimultaneouslypresstheLockbuttonandthespecificlockoutcontroldesired(eitherupordown).
• Anaudiblealarmsoundsandtheamberlightdisappearswhenalockoutisdeactivated.
line MAnAgers• Simplifyandorganizepatientlinestoavoidentanglementorpinching.
• Flexibleandcanbebentinanyposition.
• NOTE: Do not wrap cords around the line managers.
sleeP Mode• Sleepmodetemporarilydisablestheairsystemtoallowpatientswhoaresensitivetosleepsurfacemovementtosleep.
• Airpressureinthemattressismonitored,buttheairpumpwillnotrununlesstheairpressurefallsbeloworaboveapresetlevel.
• NOTE: Sleep mode remains active for 8 hours. After 8 hours, the surface will revert back to Pressure Relief/Normal Mode.
To AcTivATe:
• PresstheEnable Control.
• SimultaneouslypresstheLeftTurnAssistandRightTurnAssistcontrolandholdfor5seconds.After5seconds,therightandleftTurnAssistindicatorswillilluminate.
To deAcTivATe:
• PresstheEnableControl.
• Pressanysurfacecontrol.
• NOTE: Sleep mode remains active for 8 hours. After 8 hours, the surface will revert back to Pressure Relief/Normal Mode.
heAd-oF-bed (hob) Angle AlArM• Visuallyconfirmthehead-of-bediselevated30degreesorhighertocomplywithprotocols.
• HOBanglealarmcanbeeasilysettonotifycaregiversiftheHOBisloweredlessthan30°.
To AcTivATe:
• Raisethehead-of-bedabove30°.
• PresstheEnable Key.
• Pressthe30°head-of-bedbutton.Thegreenbuttonwilllightuptoindicatethealarmhasbeenset.
To deAcTivATe:
• PresstheEnable Key.
• Pressthe30°head-of-bedbutton.Thegreenindicatorwillgooff.
turn Assist• Assistswithturningthepatientforlinenchanges,dressingchanges,bedpanning,backcareandothernursingprocedures.
• SiderailsmustbeintheuppositiontoactivateTurnAssist.
• OnceTurnAssistisinitiated,youmaylowerasiderailtofacilitatepatientcare.Thebedwillalarmasaprecaution.
• TurnAssistcanbeactivatedfromeithersideofthebed.
To AcTivATe:
• PresstheEnable ControlandtheneitherLeft Turn orRight Turnonthesiderail.
MAx inFlAte• Maximizesthefirmnessoftheprimarysectionofthepatientsurface.
• Assistsinpatientsurface-to-surfacetransfersand/orrepositioning.
• BedwillstayinMaxInflatefor30minutesbeforereturningtonormal/standardstate.
To AcTivATe:
• PresstheEnable ControlandthenpresstheMax Inflatebuttononthesiderail.
To deAcTivATe:
• PresstheenablecontrolandthenpressthePressure Relief/Normalbutton.
Longer
Shorter
Longer
Shorter
Chair
Boost™
Longer
Shorter
Longer
Shorter
Turn LTurn R
Turn LTurn R
Max. InflateNormal
Turn LTurn R
Turn LTurn R
Max. InflateNormal
Longer
Shorter
Longer
Shorter
Lock button
Bed Up/Down
Head Up/Down
FoR comPleTe inSTRucTionS on How To oPeRATe THe veRSAcARe® bed, See uSeR’S mAnuAl.
Hill-Rom reserves the right to make changes without notice in design, specifications and models. The only warranty Hill-Rom makes is the express written warranty extended on the sale or rental of its products.
©2014 Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
ORDERNUMBER 174461 rev 2 14-MAR-2014 ENG – US
Zinc Number US-AC-1113-0583
www.hill-rom.com
USA 800-445-3730 CANADA 800-267-2337