T Y P I C A L A P P L I C A T I O N S
Anti-climbing system for pylons:The Type AAF adjusts to tdifferent thicknesses of steel and offers vertical adjustability.
2 3 41
Bridge strengthening:This combined loading conguration(slip resistance and tension) allows one connection design tobe used on multiple sections.
Lifting points:Lindapter manufactures customized assembliesfor specic load requirements e.g. vertical, angle or horizontalloads.
Roof supports:The Type AAF is ideal for connecting tocurved roofs. This assembly provides vertical and horizontaladjustability.
Type AAF N E WP R O D U C TLindapters agship product features an innovative2-part design that allows the clamp to self-adjust to suita range of ange thicknesses, while the low temperatureSG iron provides resistance in cold environments whereimpact strength is important.
This Adjustable AF is an enhanced version of LindaptersType AF product (page 6) and maintains the same safeworking load capacities but is faster to install due to animpressive clamping range of1/4 - 13/16 (size5/8).
Safe Working Loads Dimensions
TensileResistance
/ 1 Bolt(F.O.S 4.5:1)
SlipResistance1)
/ 2 Bolts(F.O.S 2:1)
V Y X U
ProductCode
Bolt PaintedSteel2)
Galv.Steel
TighteningTorque
ClampingRange3)
W
Size Gradelbs lbs lbs ft lb
LAAF050 1/2 Grd. 5/A325 1911 764 877 66 3/16 - 1 1 - 15/16 11/16 - 115/16 11/32 - 11/8
LAAF062 5/8 Grd. 5/A325 3597 1798 2248 177 1/4 - 13/16 15/16 - 2 11/4 - 2 5/16 13/8 - 113/16 2
LAAF050 1/2 A490 2248 899 1169 96 (74*) 3/16 - 1 1 - 15/16 11/16 - 115/16 11/32 - 11/8
LAAF062 5/8 A490 4383 2473 2698 221 (184*) 1/4 - 13/16 15/16 - 2 11/4 - 2 5/16 13/8 - 113/16 2
1) Slip Resistance gures are based on Type AAF and Location Plates in hot dip galvanized nish calculated against slip (movement exceeding 0.004 / 0.1mm).2) Shot blast and painted steel3) For thicker anges, packing pieces AFP1 and AFP2 are available.* Torque for lubricated boltsNB. Y, X and U willvary depending on the thickness of V.
Material: Low temperature SG iron to EN 1563, hot dip galvanized to EN ISO 1461.
Nose RockingWasher
TailN E WP R O D U C T
TECHNICA L DATA
U
YX
V
-
8/10/2019 USA - Lindapter High Slip Resistance Clamps
4/7
www.LindapterUSA.com
T Y P I C A L A P P L I C A T I O N S
2 3 41
Cladding support system:Perforated steel cladding isconnected to a vertical column providing vertical and lateraladjustment (Portello Project, Milan, Italy).
Roof supports:The iconic curved roof at St Pancras Station,London, is secured by Type AF clamps in an assembly thatattaches roof supports to the original riveted steel frame.
Conveyor supports:This 1 Type AF clamp assembly provideda high t ensile load capacity of 56,200lbs required for theconveyor supports at Gatwick Airport, UK.
Bridge strengthening assembly:Type AF girder clamps areused to strengthen the up-line girders of Mortons LeamBridge, Cambridgeshire, UK.
The product specications of all Lindapter HSR clamps are independentlyveried by TV Nord and this heavy duty clamp offers the highest loadingcapacities available, for example, a typical four b olt conguration hasa static slip resistance of up to 15,736lbs or tensile resistance up to56,200lbs.
Type AF requires a specic conguration of packing pieces to be installedunder the clamp to suit the thickness of the ange (page 10). If there is arequirement to connect various sized steel sections or low temperatureconsiderations, the Type AAF is recommended (page 4).
Type AF
TECHNICA L DATA
Safe Working Loads Dimensions
TensileResistance
/ 1 Bolt(F.O.S 5:1)
SlipResistance1)
/ 2 Bolts(F.O.S 2:1)
Y X V
Tail Length
T
ProductCode
Bolt PaintedSteel2)
Galv.Steel
TighteningTorque
s ho rt me di um Ty peAF
Type AFw/AFW
W
Size Gradelbs lbs lbs ft lb
LAF050 1/2 Grd. 5/A325 1911 764 877 66 11/8 11/16 3/16 1/2 11/16 7/8 1
LAF062 5/8 Grd. 5/A325 3597 1798 2248 177 13/8 11/2 5/16 9/16 7/8 11/16 1
LAF075 3/4 Grd. 5/A325 5901 2922 3597 347 1 9/16 19/16 3/8 11/16 1 11/4 2
LAF100 1 Grd. 5/A325 8892 5395 6774 590 17/8 2 3/8 9/16 11/8 11/4 15/8 3
LAF050 1/2 A490 2248 899 1169 96 (74*) 11/8 11/16 3/16 1/2 11/16 7/8 1
LAF062 5/8 A490 4383 2473 2698 221 (184*) 13/8 11/2 5/16 9/16 7/8 11/16 1
LAF075 3/4 A490 6744 4496 5620 477 (332*) 1 9/16 19/16 3/8 11/16 1 11/4 2
LAF100 1 A490 14050 3) 6295 7868 737 (590*) 1 7/8 2 3/8 9/16 11/8 11/4 15/8 3
Nose
Skirt
Recess
Tail
T
XY
V
1) Slip Resistance gures are based on Type AF and Location Plates in hot dip galvanized nish calculated against slip (movement exceeding 0.004 / 0.1mm).2) Shot blast and painted steel3) 3.2:1 Factor of Safety * Torque for lubricated bolts
Material: SG iron to EN 1563, hot dip galvanized to EN ISO 1461.
-
8/10/2019 USA - Lindapter High Slip Resistance Clamps
5/7
www.LindapterUSA.com
T Y P I C A L A P P L I C A T I O N S
2 31
Type CFThis clamp hooks over the angesof beams, angles and channels toprovide a connection solution insituations where the anges ofthe connecting steel sections donot face each other, for example,connecting upright horizontalbeams to vertical columns.
Type CF can be combined with allLindapter HSR clamps when usedwith Grade A325 bolts (refer tothe opposite page for safe workingloads).
Cladding:The Type CF secures GRC panels to a vertical steelsection, allowing both vertical and horizontal adjustment.
Roof supports:New steel is attached to an existing frame atthe Chivas Regal Distillery, Keith, Scotland in an application thatrequires high slip resistant capacities.
Towers and masts:A communications antenna is secured to atower with a connection assembly that is quick to install andoffers vertical adjustability.
Overhead line equipment:A messenger/catenary wire issupported from a steel frame in a combined load application.
TECHNICA L DATA
Safe Working Loads Dimensions
Tensile Resistance/ 1 Bolt
(F.O.S 5:1)
Slip Resistance1) / 2 Bolts(F.O.S 2:1)
Y X V T t
ProductCode
BoltGrd. 5 / A325
PaintedSteel2)
Galv.Steel
TighteningTorque
ClampingRange
W
lbs lbs lbs ft lb
LCF050 1/2 1911 764 877 66 11/4 9/16 1/4 -1/2 13/16 - 11/8 1
LCF062 5/8 3597 1798 2248 177 13/4 11/16 5/16 -5/8 1 - 11/4 11/4 2
LCF075 3/4 5901 2922 3597 347 2 1/16 7/8 3/8 -3/4 13/16 - 19/16 13/4 2
Y X
T
V
t
1) Slip Resistance gures are based on Type CF and Location Plates in hot dip galvanized nish calculated against slip (movement exceeding 0.004 / 0.1mm).2) Shot blast and painted steel
Material: SG iron to EN 1563, hot dip galvanized to EN ISO 1461.
Nose Anti-rotation marks
Legs
4
-
8/10/2019 USA - Lindapter High Slip Resistance Clamps
6/7
www.LindapterUSA.com
Packings to adjust the clamps tail length tomeet different beam ange thicknesses.
Type AF Accessories
Parallel anges and beams of up to 5o slope.
Product Code Bolt Dimensions(T)
LAF050CW 1/2 1/16
LAF050P1 1/2 3/16
LAF050P2 1/2 3/8
LAF062CW 5/8 1/16
LAF062P1 5/8 3/16
LAF062P2 5/8 3/8
LAF075CW 3/4 1/16
LAF075P1 3/4 3/16
LAF075P2 3/4 3/8
LAF100P1 1 3/16
LAF100P2 1 3/8
FlangeThickness 1/ 2 5/ 8 3/ 4 1
AF AFCW AFP1 AFP2 AF AFCW AFP1 AFP2 AF AFCW AFP1 AFP2 AF AFP1 AFP2
3/16 s - - - - - - - - - - -
1/4 s - - - - - - - - - - -
5/16 s 1 - - s - - - - - - - -
3/8 s - 1 - s 1 - - s - - - - -
7/16 s - 1 - s 1 - - s - - - - -
1/2 m - - - s - 1 - s 1 - - s - -
9/16 m 1 - - m - - - s 2 - - s - -
5/8 s - - 1 m - - - s - 1 - s - -
11/16 m - 1 - m 1 - - m - - - s - -3/4 s 2 - 1 m 2 - - m - - - s 1 -
13/16 s - 1 1 m - 1 - s - - 1 s 1 -
7/8 m - - 1 m 1 1 - m 2 - - s 1 -
15/16 m 1 - 1 m 2 1 - m - 1 - s - 1
1 s - - 2 m - - 1 m 1 1 - s - 1
1 1/16 s 1 - 2 m 1 - 1 m 2 1 - s - 1
1 1/8 m 3 - 1 s - - 2 m - - 1 s - 1
1 3/16 s - 1 2 m - 1 1 m 1 - 1 m - -
1 1/4 s 1 1 2 m 1 1 1 m 2 - 1 m - -
1 5/16 m - - 2 s - 1 2 m - 1 1 m - -
1 3/8 s - - 3 m - - 2 m 1 1 1 m 1 -
1 7/16 m 2 - 2 m 1 - 2 m 2 1 1 m 1 -
1 1/2 m - 1 2 s - - 3 m - - 2 m - 1
1 9/16 m 1 1 2 m - 1 2 m 1 - 2 m - 1
1 5/8 m 2 1 2 m 1 1 2 m 1 - 2 m - 1
1 11/16 m - - 3 s - 1 3 m - 1 2 m 1 1
1 3/4 m 1 - 3 m 2 1 2 m 1 1 2 m 1 1
1 13/16 s 3 1 3 s 4 - 3 s 3 - 3 m 1 1
1 7/8 s 1 - 4 m 1 - 3 m - - 3 m 1 1
1 15/16 m 1 1 3 m 2 - 3 s 2 1 3 m - 2
2 s - 1 4 m 3 - 3 s 3 1 3 m - 2
s = short m = medium = Type not applicable
PACKING PIECES TAIL LENGTH / PACKING COMBINATIONS
A washer used to ll the Type AF recess. TheType AFW features two projections which,when inverted, willcaptivate and preventrotation of the largerhexagons of A325 orA490 bolts (1/2 to3/4). LAF100W (size 1)has no projections.
TYPE AFW
T
Product Code Bolt Dimensions(T)
LAF050W 1/2 3/16
LAF062W 5/8 3/16
LAF075W 3/4 1/4
LAF100W 1 3/8
Location and End Plates
Location Plate End Plate1)
Bolt Hole Plate
Thickness
Hole
Centers
Length /
Width
Plate
Thickness
Hole
Center
Length Hole
Center
Wid
d l1M, l2M min l1, min l2 l1M min L1 min l2M min
1/ 2 9/16 1/2 b +9/16 b + 4 5/8 b1 + 9/ 16 b1 + 4 31/ 8 l2M + 3
5/8 11/ 16 5/ 8 b +11/ 16 b + 4 1 b1 + 11/16 b1 + 4 4 l2M +
3/4 13/16 3/ 4 b +13/16 b + 5 11/ 4 b1 + 13/ 16 b1 + 5 7 l2M +
1 11/8 1 b + 11/8 b + 7 15/8 b1 + 11/ 8 b1 + 7 77/8 l2M + 7
PLATE DIMENSIONSMaterial: Mild steel minimum grade S355 JR/J0/J2 to be specied by the Engineer to suit the application.
The Lindapter Support ServiceLindapters experienced Engineers will design your connection free-of-charge to ensure a hassle-free specication process. Email yourconnection requirements to [email protected]
1) Depending on the type of connection and associated end plate used, the thickness may need to be modied to comply with accepted localdesign codes.
This is an essential part of the girder clampassembly that enables all the componentsto be located in the correct position. The holecenters and plate thickness are calculatedto suit the individual application.
L1 = Plate lengthL2 = Plate widthl1M, l2M = Hole centersb1, b2 = Flange widthd = Hole
The Technical Support service includes:
DisclaimerLindapter International supplies components in good faith, on t he assumption that customers fully understand t he loadings, safety factors and physical parameters of the products involved. Custousers who are unaware or unsure of any details should refer to Lindapter International before use. Responsibility for loss, damage, or other consequences of misuse cannot be accepted. Lindapter every effort to ensure that technical specications and other product descriptions are correct. Specication shall mean the specication (relating to the use of the materials) set out in the quotatby the Seller to the Buyer. Responsibility for errors or omissions cannot be accepted. All dimensions stated are subject to production tolerances - if in doubt please check with Lindapter. In the inimproving the quality and performance of Lindapter products, we reserve the right to make specication changes without prior notice.
Lindapter International 2014Lindapter is a registered trademark. Lindapter may also have trademark rights in other t erms used herein.
FREE CONNECTION DESIG
2D / 3D DRAWINGS
QUOTATION
INSTALLATION GUIDANCE
Location Plate End
L1l1M
b1
L1l1M
b1
L2b2 l2M l2M
d
d
3D
$$ $T
T
-
8/10/2019 USA - Lindapter High Slip Resistance Clamps
7/7
General Inquiries:[email protected]
Technical Inquiries:[email protected]
Website:www.LindapterUSA.com
Find your nearest representativeat www.LindapterUSA.com
Regional Sales & Technical Support