Trigeneration & Boiler Sizing Optimization
![Page 2: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/2.jpg)
Presentation at a Glance Overview Trigen Concept System Configuration Benefits & Risks Conclusions
![Page 3: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/3.jpg)
Trigeneration Concept
![Page 4: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/4.jpg)
Conventional Trigeneration
Trigen Facility
Natural Gas
Natural Gas
Boiler
Electricity
MVAC Chiller
Power Demand
Steam
Chilled Water
Hot Water
Utilities Requirement
![Page 5: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/5.jpg)
Electricity Cooling Heat
Trigeneration Schematic at GSK
Gas Engine
Alternator
Elec
tric
ity
Air
NG
1.8 MW
Exha
ust g
as St
eam
Boi
ler
Econ
omiz
er
Was
te H
eat
Rec
over
y B
oile
r
Feed
Wat
er
1.2 t/h
Hot
Wat
er
Hot
Wat
er
Econ
omiz
er
Hot
Wat
er R
etur
n
300 kWh
HT Transmission Cycle Heat Exchanger
HT Loop Absorption Chiller
200 RT
Chi
lled
Wat
er
Coo
ling
Wat
er
![Page 6: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/6.jpg)
Scheme Design
![Page 7: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/7.jpg)
Design Considerations
Gas Engine - higher power to heat ratio Waste heat boiler & hot water generator to
recover engine exhaust air (> 420 °C) Hot water Absorption chiller to recover GE
Jacket HT waste heat (> 90 °C) 100% hot water (consistent load) generation
from Trigen Fuel boiler with high turndown ratio
![Page 8: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/8.jpg)
Utilization > 90% per year Operating > 90% of capacity Equipment life span for 10+ year MVAC chiller & fuel boiler for 100% back-up Fuel boilers load as little as possible No impact on existing buildings appearance
Operational Requirement
![Page 9: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/9.jpg)
Initial Configuration
![Page 10: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/10.jpg)
GSK optimization project consists of: Trigenetaion: Gas Engine (2 MW rated capacity) Waste Heat Boiler (1.2T Steam @ 9 barg ) Absorption Chiller (200 RT Chilled Water) Hot water Generator (> 50°C Hot water) Boiler Downsizing 2 x 5T high efficiency dual fire boiler
Overview of system
![Page 11: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/11.jpg)
After Optimization
![Page 12: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/12.jpg)
Trigeneration Facility
Gas Engine
Waste Heat Boiler
![Page 13: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/13.jpg)
Hot Water Absorption Chiller
![Page 14: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/14.jpg)
Fuel Fire Boilers
Before After
![Page 15: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/15.jpg)
Benefits
![Page 16: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/16.jpg)
Support GSK climate change & sustainability commitment Improve energy efficiency Operational cost saving Support business continuity plan
Trigeneration = Business Sense
Why Trigeneration?
![Page 17: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/17.jpg)
Other Favorable Factors Right match for plant utilities usage profile
(consistent power, heating & cooling load) Natural gas available at competitive price Proven technology (availability >90%) Government policies to support green
initiatives e.g. GREET fund Support national policies demonstrated
(Energy Conservation Act)
![Page 18: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/18.jpg)
Integrated with 2 smaller boilers:
Reduce heat losses % vs amount energy input
Higher turndown ratio allow wider operating range
Lower regulatory requirement e.g. Steam Engineer requirement
Additional space in boiler room
Boiler Downsizing
![Page 19: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/19.jpg)
Annual energy consumption
Results
0
10,000
20,000
30,000
40,000
50,000
60,000
70,000
80,000
90,000
100,000
Before Improvement After Improvement
19,152 MWh
44,423 MWh
76,129 MWh
42,045 MWh
ElectricityGas
MWh Energy Reduction ~ 9%
![Page 20: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/20.jpg)
Potential Risks
![Page 21: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/21.jpg)
Fears & Threats Change of site utilities demand profile Electricity price drop or gas price increase Reliability issues Competent local vendor support Change of local regulatory requirement
![Page 22: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/22.jpg)
Conclusions
![Page 23: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/23.jpg)
Suitable for facilities with continuous and stable demand level/minimum fluctuation on heating, cooling and power Energy efficiency & benefits of Trigen
depend on ability to utilize all heat energy Overall Trigen efficiency varies between
70% - 80% depending on design & usage
Conclusions
![Page 24: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/24.jpg)
Absorption chillers offer substantial CO2 savings over electric chillers Available of Natural Gas supply at
competitive price is required to make the investment attractive Multiple small size equipment installation
provide more flexibility
Conclusions
![Page 25: Trigeneration & Boiler Sizing Optimization Siou … · Waste heat boiler & hot water generator to recover engine exhaust air (> 420 °C)](https://reader030.vdocuments.us/reader030/viewer/2022040612/5f027a917e708231d40476a6/html5/thumbnails/25.jpg)
Thank you