Dependability and maximum protection
Part of Thermo Fisher Scientific
Thermo Scientific Forma®
Class II Biological Safety Cabinets and Laminar Airflow Workstations
BRO-CECA-BSCLAF-0207.qxd 06.02.2007 12:48 Uhr Seite 17
Our Advantage: Protection, Performance, Convenience...
You’re always seeking an advantage – the protection of a safe environment in whichto handle moderate to high risk microorganisms (biosafety level 1, 2, or 3 agents) forcell culturing, sample analysis, diagnostic procedures, or preparation of therapeuticagents; high quality equipment that will withstand the rigors of lab use and performreliably day after day; comfort and convenience that make your work life easier andmore productive.
For decades, researchers worldwide have trusted and valued Thermo Scientificlaboratory equipment: the number one selling cell culture incubator in the world, highperformance -86°C freezers, and a comprehensive solution for your biosafety andlaminar airflow cabinet needs.
Thermo Scientific Forma Class II Biological Safety Cabinets and Laminar AirflowWorkstations are trusted worldwide for their solid construction and dependabilitywhile providing maximum protection at an affordable price.
Carefully directed, laminar airflow is key to optimum cabinet performance. Biosafety cabinet certifiers have noticed the consistency of our cabinets’ airflow.That stable, balanced airflow is the result of reliable design and quality constructionthat produce a precisely controlled Class 100 or better environment. Our laminarairflow workstations (clean benches) are designed to prevent “backwashing.”Contaminated outside air will not drift back into the workstation’s work area,ensuring product protection.
Thermo S
cientificForm
a ClassII B
iosafetyCabinets
and Laminar Airflow
Workstations
Features and Technical Specifications
2
BRO-CECA-BSCLAF-0207.qxd 06.02.2007 12:46 Uhr Seite 2
3
BREADTH OF PRODUCTS
You can trust our biosafety and laminar airflow cabinets to provide the reliable protection you depend on everyday.
Class II, A1 Biosafety Cabinets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6Class II, A2 Biosafety Cabinets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8Laminar Airflow Benchtops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12Laminar Airflow Consoles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
VARIETY OF ACCESSORIES
We help you create an organized, complete biosafety cabinet or laminar airflowworkstation tailored to your work requirements and comfort needs (Class II, A2 BiosafetyCabinet shown).
Accessories for Biological Safety Cabinets . . . . . . . . . . . . . . . .10Accessories for LaminarAirflow Workstations . . . . . . . . . . . . .15
3 Year
Warranty
BRO-CECA-BSCLAF-0207.qxd 06.02.2007 12:46 Uhr Seite 3
...for Peace of Mind and
Optional ExhaustTransition withZero Leak Damper
Front AccessHEPA Filters
Frameless Sash
OptionalAdjustableModular Stand
OptionalArmrest
Thermo S
cientificForm
a ClassII B
iosafetyCabinets
and Laminar Airflow
Workstations
Features and Technical Specifications
4
a Workstation Tailored to Your Needs
BRO-CECA-BSCLAF-0207.qxd 06.02.2007 12:47 Uhr Seite 4
Minihelic®
Pressure Gauge
Sidewall MountedOutlet and ServiceValve(s)
Optional ADAControl Panel
Optional Universal Piping
Exclusive VortexChannels
Rounded Front
Optional Storage Drawers
Optional Lab Chair
Optional Adjustable Footrest
5
Added convenience of standard features and a variety of accessories allow you tosimplify daily use and routine procedures. Large sash openings on biosafety cabinetsincrease your mobility and depth of reach into the work area. Under-cabinet drawershelp you organize your work area by providing local storage for pipettes, gloves, etc.
BRO-CECA-BSCLAF-0207.qxd 06.02.2007 12:47 Uhr Seite 5
Ambient Air
HEPA Filter
Contaminated Air (positive pressure)
Contaminated Air (negative pressure)
HEPA Filtered Air
A1 Benchtop: Ideal When Lab Space is Limited
The Class II, A1 benchtop cabinet’s small footprintprovides 2.9 sq. ft. (0.3 sq. m) of work area whilerequiring only 5.4 sq. ft. (0.5 sq. m) of valuable labspace.
When space is limited, the Model 1118 is a practicalchoice when a clean air environment and product,personnel, and environment protection are requiredfor working with agents assigned to biosafety levels1, 2, or 3 in the absence of volatile toxic chemicalsand volatile radionuclides.
Dependable Protection, Easy to Use
• Unit has a recessed, hinged, front window of 0.25" (6mm) thick laminated safety glass with a10.0" (254mm) access opening that enhances yourmobility and depth of reach into the work area.
• Interior work area and tray are constructed ofheavy-gauge, corrosion-resistant, type 304stainless steel for easy cleaning.
• Voltage Compensating Speed Control ensures that the motor receives constant voltage when the power line voltage fluctuates, providing stableairflow and increasing laboratory, product, andpersonnel safety.
• Internal damper for balancing airflow is easilyadjusted from within the work area and eliminatesthe need to decontaminate the unit beforeadjustment.
• Optional exhaust transition allows the cabinet to be vented externally. A facility exhaust blower isrequired.
Carefully Directed Airflow
Airflow descends from the top of the cabinetthrough a supply HEPA filter. As this verticalairstream approaches the work surface, the airflowsplits. Approximately 50% is drawn into thecabinet’s rear intake grille, and the rest meetsambient room air at the front intake grille.
The air is then drawn into a plenum surrounding thework area by the blower located in the top of thecabinet. The blower pushes the air into a positivepressure plenum. The pressurized air is split, with30% vented through the exhaust HEPA filter and theremaining 70% recirculated through the supplyHEPA filter.
Thermo S
cientificForm
a ClassII, A1 B
iologicalSafety
CabinetsFeatures and Technical Specifications
A1 BENCHTOPAIRFLOWInflow velocity – 75 FPM minimum70% – recirculated within the cabinet30% – exhaustedAdded protection – positive pressure plenum is surrounded by negative pressure
U.S. Patent held is 5,380,244.
6
BRO-CECA-BSCLAF-0207.qxd 06.02.2007 12:47 Uhr Seite 6
7
A1 Benchtop Specifications
Model2 Ft. Benchtop . . . . . . . 1118
Work AreaWidth. . . . . . . . . . . . . . . 22.5"" (572mm)Height . . . . . . . . . . . . . . 26.5" (673mm)F-B. . . . . . . . . . . . . . . . . 19.5" (495mm)Sash Opening . . . . . . . . 10.0" (254mm)
Exterior Dimensions Width. . . . . . . . . . . . . . . 28.5" (724mm)Height . . . . . . . . . . . . . . 58.5" (1486mm)Depth . . . . . . . . . . . . . . 27.5" (699mm), deduct
2.0" (51mm) from Depth forlight canopy
Electrical, Plug, Breaker, & Motor1118 . . . . . . . . . . . . . . . 115V, 60 Hz, 6.7 FLA115V . . . . . . . . . . . . . . . Two NEMA 5-15P PlugsBreaker Requirement . . 15 AmpMotor . . . . . . . . . . . . . . 1/3 HP
Exhaust Requirements1118 . . . . . . . . . . . . . . . 136-151 CFM*Canopy Exhaust (opt.) . Add 30% to exhaust CFMConnection . . . . . . . . . . 8.0" (203mm) diameter
duct connection, 0.25" w.g.psi drop at the connection
Service Valve1118 . . . . . . . . . . . . . . . 1, left side
Additional Plugged Penetration1118 . . . . . . . . . . . . . . . 1, left side
Outlets115V . . . . . . . . . . . . . . . 1, NEMA 5-15R single,
on the control panel(12 Amps)
Unit Heat Load115V . . . . . . . . . . . . . . . 2500 BTUH (740 Watts)
WeightNet . . . . . . . . . . . . . . . . 302 lbs. (137.0 kg)Shipping (Motor) . . . . . . 368 lbs. (166.9 kg)
220V, 50 Hz Model 1119 is available upon request (not UL Listed).*Cubic Feet per Minute (CFM) is based on the Direct Airflow Method, under clean conditions.
Optional Fixed Height Modular Stand
Stock No. Description191386 30.0"H (762mm)191387 36.0"H (914mm)
Minimum Height (Leveler In) Maximum Height (Leveler Out)Height No. 191386 No. 191387 No. 191386 No. 191387
Stand Height 25.5" (648mm) 31.5" (800mm) 26.8" (681mm) 32.8" (833mm)
Work Surface Height 28.3" (719mm) 34.3" (871mm) 29.6" (752mm) 35.6" (904mm)
Total Height of Cabinet with Stand 84.0" (2134mm) 90.0" (2286mm) 85.3" (2167mm) 91.3" (2319mm)
BRO-CECA-BSCLAF-0207.qxd 06.02.2007 12:47 Uhr Seite 7
Thermo S
cientificForm
a ClassII, A2 B
iologicalSafety
CabinetsFeatures and Technical Specifications
8
A2 BENCHTOPAIRFLOWInflow velocity – 100 FPM minimum70% – recirculated within the cabinet30% – exhaustedAdded protection – positive pressureplenum is surrounded by negativepressure
U.S. Patents held include 5,050,943;5,295,902; 5,380,244; and 6,036,737.
A2 Benchtops: Flexible Use
The Class II, A2 cabinet is a popular choice when aclean air environment and enhanced product, personnel,and environment protection are required for workingwith agents assigned to biosafety levels 1, 2, or 3.
The cabinet may be vented directly into the lab inthe absence of volatile toxic chemicals and volatileradionuclides. If connected to a properly functioningexhaust canopy, an A2 cabinet is suitable for workwith minute quantities of volatile toxic chemicalsand tracer amounts of radionuclides when requiredas an adjunct to microbiological studies.
Greater Protection, Larger Work Area
• Frameless glass window ensures a clear,unobstructed view of the work area.
• Large 10.0" (254mm) sash opening enhances yourmobility and depth of reach into the work area,while still providing maximum protection.
• The 49.0" (1245mm) wide work area is 3.0"(76mm) larger than other major competitors’,providing additional work space for your research.
• For additional product and personnel protection,unique, patented Vortex Channels create highvelocity air at the window corners to moveturbulent air into the return air system, reducingthe risk of particulates escaping from or enteringthe cabinet work area.
• A 3/4 HP blower/motor provides enough reserveairflow capacity that our cabinet can accept up toa 230% increase in filter resistance and still meetNSF recommended airflow specifications, extendingfilter life and reducing maintenance costs.
• UV interlock provides additional safety by prohibitingUV light operation unless the sash is fully closed.
Directed Airflow for a Sterile Work Area
Airflow descends from the top of the cabinetthrough a supply HEPA filter. As this verticalairstream approaches the work surface the airflowsplits. Approximately 50% is drawn into thecabinet’s rear intake grille, and the rest meetsambient room air at the front intake grille.
The air is then drawn into a plenum surrounding thework area by the blower located in the top of thecabinet. The blower pushes the air into a positivepressure plenum. The pressurized air is split, with30% vented through the exhaust HEPA filter andthe remaining 70% recirculated through the supplyHEPA filter.
Ambient Air
HEPA Filter
Contaminated Air (positive pressure)
Contaminated Air (negative pressure)
HEPA Filtered Air
BRO-CECA-BSCLAF-0207.qxd 06.02.2007 12:47 Uhr Seite 8
9
A2 Benchtop Specifications
Models4 Ft. Benchtop . . . . . . . 1284 (1285)6 Ft. Benchtop . . . . . . . 1286 (1287)
Work AreaWidth - 1284 (1285) . . . 49.0" (1245mm)Width - 1286 (1287) . . . 73.0" (1854mm)Height . . . . . . . . . . . . . . 28.4" (721mm)F-B. . . . . . . . . . . . . . . . . 22.7" (577mm)Sash Opening . . . . . . . . 10.0" (254mm)
Exterior Dimensions Width - 1284 (1285) . . . 54.0" (1372mm)Width - 1286 (1287) . . . 78.0" (1981mm)Height . . . . . . . . . . . . . . 64.0" (1626mm), add 3.0"
(76mm) for exhaust grille F-B*. . . . . . . . . . . . . . . . 32.5" (826mm)
Electrical, Plug, Breaker, & Motor1284 . . . . . . . . . . . . . . . 115V, 60 Hz, 13.5 FLA1286 . . . . . . . . . . . . . . . 115V, 60 Hz, 13.8 FLA1285 . . . . . . . . . . . . . . . 230V, 50 Hz, 9.6 FLA 1287 . . . . . . . . . . . . . . . 230V, 50 Hz, 7.5 FLA115V . . . . . . . . . . . . . . . NEMA 5-20P Plug230V . . . . . . . . . . . . . . . CEE 7/7 PlugBreaker Requirement . . 1284/1286: 20 Amp
1285/1287: 15 AmpMotor . . . . . . . . . . . . . . 3/4 HP
Exhaust Requirements1284 (1285) . . . . . . . . . . 357-391 CFM**1286 (1287) . . . . . . . . . . 530-580 CFM**Canopy Exhaust (opt.) . Add 30% to exhaust CFM
Exhaust Requirements (continued)Connection . . . . . . . . 8.0" (203mm) diameter
duct connection, 0.25" w.g.psi drop at the connection
Service Valves1284 (1285) . . . . . . . . . . 1, right sidewall1286 (1287) . . . . . . . . . . 2, 1 on each sidewall
Additional Plugged Penetrations1284 (1285) . . . . . . . . . . 3, 1 on right and 2 on left
sidewall1286 (1287) . . . . . . . . . . 2, 1 on each sidewall
Outlets115V . . . . . . . . . . . . . . . 2 GFIC protected duplex,
1 on each sidewall(1284 = 5 Amps,1286 = 2 Amps)
230V . . . . . . . . . . . . . . . 2, CEE 7 single, 1 on eachsidewall (1285 = 5 Amps,1287 = 2 Amps)
Unit Heat Load1284 . . . . . . . . . . . . . . . 2830 BTUH (830 Watts)1285 . . . . . . . . . . . . . . . 3770 BTUH (1,110 Watts)1286 (1287) . . . . . . . . . . 3600 BTUH (1,060 Watts)
WeightNet
1284 (1285) . . . . . . . . 538 lbs. (244.0 kg)1286 (1287) . . . . . . . . 720 lbs. (326.6 kg)
Shipping (Motor)1284 (1285) . . . . . . . . 735 lbs. (333.4 kg)1286 (1287) . . . . . . . . 940 lbs. (426.4 kg)
All units are UL Listed to United States and Canadian requirements and NSF Listed. *Remove light canopy, dress and control panels, and window channel for 28.0" (711mm) F-B.**Cubic Feet per Minute (CFM) is based on the Direct Airflow Method, under clean conditions.
Optional Adjustable Modular Stand
Stand is designed in accordance with AmericanDisabilities Act (ADA) guidelines. Work surfaceheight is adjustable in 1.0" (25mm) increments.
Stock No. Description191550 For 4 Ft. A2 Units191551 For 6 Ft. A2 Units191684 Caster Dolly
An optional hydraulic crank-up stand is available.Refer to the Accessories for Biological SafetyCabinets section for details about that stand,drawer assemblies, etc.
®
Height Minimum Height (Leveler In) Maximum Height (Leveler Out)
Stand Height 23.4" (594mm) 32.7" (831mm)
Work Surface Height 26.5" (673mm) 35.8" (909mm)
Total Height of Cabinet with Stand* 90.4" (2296mm) 99.7" (2532mm)
*Recommended minimum clearance is 5.0" (12.7cm) additional above the unit for certification (based on Direct Airflow Method).
BRO-CECA-BSCLAF-0207.qxd 06.02.2007 12:48 Uhr Seite 9
Accessoriesfor B
iologicalSafety
CabinetsFeatures and Technical Specifications
10
Our biosafety cabinet accessories allow you to createa complete workstation that provides comfort andconvenience as well as functionality. All accessoriesare customer installed unless noted otherwise.
Hydraulic Crank-Up Stand for A2 Benchtops
Vertical travel range is 7.0" (178mm). Levelersinclude 1.3" (33mm) of adjustment. Handle folds out of the way for convenience and safety.
Stock No. Description191518 For 4 Ft. A2 Units191519 For 6 Ft. A2 Units
Drawers for A2 Benchtop Biosafety Cabinets
Stock No. Description191494 Left Side, 4 Drawers for Adjustable
Modular Stand (A2 units),9.0"W x 18.0"H x 21.5"Depth(229mm x 457mm x 546mm)
191495 Right Side, 3 Drawers for Hydraulic Crank-Up or Adjustable Modular Stand(A2 units), 9.0"W x 18.0"H x 21.5"Depth (229mm x 457mm x 546mm)
191524 Left Side, 2 Drawers for HydraulicCrank-Up Stand Only (A2 units),9.0"W x 10.1"H x 21.5"Depth (229mm x257mm x 546mm)
191591 Roller Base for Drawer Assembly, adds 3.0" (76mm) to the drawerassembly height, 9.4"W x 3.6"H x21.9"Depth (239mm x 91mm x 556mm)
Ultraviolet (UV) Lights
UV Light Assemblies
Stock No. Description191418 15 Watt UV Light for 2 Ft. A1
Model 1118191419 30 Watt UV Light for 4 and 6 Ft.
A2
Portable UV Lights
Stock No. Description191069 15 Watt Portable UV Light for 2 Ft.
A1 Model 1118191070 30 Watt Portable UV Light for 4 and
6 Ft. A2
Height Minimum Height (Leveler In) Maximum Height (Leveler Out)
Stand Height 24.6" (625mm) 32.8" (833mm)
Work Surface Height 27.6" (701mm) 35.8" (909mm)
Total Height of Cabinet with Stand* 91.6" (2327mm) 99.8" (2535mm)
*Recommended minimum clearance is 5.0" (127mm) additional above the unit for certification (based on the Direct Airflow Method).
BRO-CECA-BSCLAF-0207.qxd 06.02.2007 12:48 Uhr Seite 10
11
Exhaust Transitions
Exhaust transitions with an 8.0" (203mm) diameterduct and zero leak damper allow you to vent yourcabinet to the outside environment.
Stock No. Description191217 Canopy Style Exhaust Transition
without Damper for 2 Ft. A1Model 1118
191782 Canopy Style Exhaust Transition with Zero Leak Damper for A2 Units
Low Airflow Alarms
Stock No. Description191780 Low Airflow Alarm for A1 and A2
Units, must be installed by qualifiedpersonnel
IV Rods (complete with 4 hangers each)
Stock No. Description191190 IV Bag Hanger191571 4 Ft. Rod191572 6 Ft. Rod191576 2 Ft. Rod
Thru-Wall Port, and Service Valve and Piping Kits
Stock No. Description191140 Extra Thru-Wall Port for A1 Units,
specify left or right sidewallmount, factory installed
191275 Service Valve Kit for All Units,side mounted
191597 Service Valve Kit for A2 Units(used with No. 191620)
191620 Universal Piping Option for A2 Units, factory installed
800045 Rear Piping Kit for A1 Consoles, includes street elbow and spacer
ULPA Filters, factory installed
Stock No. Description760192 Supply and Exhaust ULPA Filters for
4 Ft. A2 Units760193 Supply and Exhaust ULPA Filters for
6 Ft. A2 Units
Additional Accessories
Stock No. Description191127 Adjustable Footrest191486 Lab Chair with Arms, meets Class
1,000 clean air specifications191487 Lab Chair without Arms, meets
Class 1,000 clean air specifications191496 ADA Control Panel for A2 Units,
factory installed191509 Armrest for 4 Ft. A2 Units191512 Armrest for 6 Ft. A2 Units6001284 IQ/OQ for Models 1148, 1168,
1284, and 1286
BRO-CECA-BSCLAF-0207.qxd 06.02.2007 12:48 Uhr Seite 11
Thermo S
cientificForm
a Laminar Airflow
Benchtop W
orkstationsFeatures and Technical Specifications
12
Laminar Airflow Benchtops: Product Protection
Our horizontal laminar airflow benchtopworkstations, often referred to as clean benches,create clean air for operations requiring a particle-free environment. These units meet requirements ofFederal Standard 209E for Class 100 (M 3.5) clean air.
Designed for Safety
The workstation’s design allows high velocity laminarair to travel across the work surface and past theoperator. When various sized objects are placedwithin the work area, the airflow does not permit“backwashing” (i.e., contaminated outside air willnot drift back into the work environment).
• All interior surfaces of the work area align with theedge of the HEPA filter media to provide truelaminar airflow, preventing “picture framing” andbackwashing of contaminated air and ensuring yourproduct’s safety.
• Work surface and sidewalls are constructed of16 gauge Type 304 stainless steel for durability and easy cleaning.
• Blower/motor automatically compensates forfilter loading between annual certifications.
• Blower/motor switch, light switch, accessoryreceptacle, and receptacle for an optional UV lightare located conveniently on the control panel.
• Built-in spill guard at the back of the work areaprotects the HEPA filter from spilled liquids,preventing filter damage and premature replacement.
• Units can be factory modified with reverse airflowto accommodate centrifuges, automated samplers,and other aerosol producing equipment. Contactour Custom Products Department.
Carefully Directed Airflow
Intake air passes through a 1.0" (25mm) fiberglassprefilter. The blower/motor unit moves the airthrough a zero-probed, HEPA filter rated at 99.99%efficient for 0.3 micron particulates.
The HEPA filtered air is then directed horizontallyacross the work surface. Positive pressure,unidirectional laminar airflow prevents any inflow ofroom air contaminants onto the work surface.
LAMINAR AIRFLOWBENCHTOPS
Designed for lab proceduresassociated with the manipulation ofnon-hazardous materials, whilemaintaining a high quality environmentof Class 100 (M 3.5) HEPA filtered airwithin the work area
Ambient Air
HEPA Filtered Air
BRO-CECA-BSCLAF-0207.qxd 06.02.2007 12:48 Uhr Seite 12
Laminar Airflow Benchtop Specifications
Models3 Ft. Benchtop . . . . . . . 1839 (1840)4 Ft. Benchtop . . . . . . . 1845 (1846)/1849 (1851)6 Ft. Benchtop . . . . . . . 1828 (1829)
Work AreaWidth - 1839 (1840) . . . 34.5" (876mm)Width - 1845 (1846)/
1849 (1851) . . . . . . . . 46.5" (1181mm)Width - 1828 (1829) . . . 70.5" (1791mm)Height - 1839 (1840)/
1849 (1851)/ 1828 (1829) . . . . . . . . 28.4" (721mm)
Height - 1845 (1846) . . . 34.4" (874mm)Depth . . . . . . . . . . . . . . 19.1" (485mm)
Exterior Dimensions Width - 1839 (1840) . . . 37.0" (940mm)Width - 1845 (1846)/
1849 (1851) . . . . . . . . 49.2" (1250mm)Width - 1828 (1829) . . . 73.2" (1859mm)Height - 1839 (1840) . . . 49.1" (1247mm) Height - 1845 (1846) . . . 59.1" (1501mm)Height - 1849 (1851) . . . 53.1" (1349mm)Height - 1828 (1829) . . . 54.1" (1374mm)Depth . . . . . . . . . . . . . . 34.0" (864mm)
Electrical, Plug, Breaker, & Motor1839 . . . . . . . . . . . . . . . 120V, 60 Hz, 7.0 FLA1845/1828 . . . . . . . . . . . 120V, 60 Hz, 12.0 FLA1849 . . . . . . . . . . . . . . . 120V, 60 Hz, 9.0 FLA1840/1851 . . . . . . . . . . . 220V, 50 Hz, 9.0 FLA1846/1829 . . . . . . . . . . . 220V, 50 Hz, 11.0 FLA
Electrical, Plug, Breaker, & Motor (continued)120V . . . . . . . . . . . . . . . NEMA 5-15P
Hospital Grade Plug220V . . . . . . . . . . . . . . . CEE 7/7 PlugBreaker Requirement . . 15 AmpMotor . . . . . . . . . . . . . . 1839 (1840)/1849 (1851):
1/3 HP1845 (1846)/1828 (1829): 1/2 HP
PenetrationsAll Models . . . . . . . . . . . 4, 2 on each sidewall
Unit Heat Load1839 . . . . . . . . . . . . . . . 2750 BTUH (810 Watts)1840/1851 . . . . . . . . . . . 6760 BTUH (1,980 Watts)1845/1828 . . . . . . . . . . . 4910 BTUH (1,440 Watts)1846/1829 . . . . . . . . . . . 8260 BTUH (2,420 Watts)1849 . . . . . . . . . . . . . . . 3680 BTUH (1,080 Watts)
WeightNet
1839 (1840) . . . . . . . . 190 lbs. (86.2 kg)1845 (1846)/
1849 (1851) . . . . . . . 325 lbs. (147.4 kg)1828 (1829) . . . . . . . . 430 lbs. (195.0 kg)
Shipping (Motor)1839 (1840) . . . . . . . . 290 lbs. (131.5 kg)1845 . . . . . . . . . . . . . . 420 lbs. (190.5 kg)1846 . . . . . . . . . . . . . . 440 lbs. (199.6 kg)1849 (1851) . . . . . . . . 400 lbs. (181.4 kg)1828 (1829) . . . . . . . . 530 lbs. (240.4 kg)
13
120V units are UL Listed to Canadian requirements. 220V, 50 Hz units and custom units are not UL Listed.
Optional Modular Stand
Stock No. Description191400 30.0"H (762mm) for 3 Ft. Units191402 30.0"H (762mm) for 4 Ft. Units191398 30.0"H (762mm) for 6 Ft. Units191401 36.0"H (914mm) for 3 Ft. Units191403 36.0"H (914mm) for 4 Ft. Units191399 36.0"H (914mm) for 6 Ft. Units
Total Cabinet Height With 30.0” Stand Total Cabinet Height With 36.0” StandModel Minimum Ht.* Maximum Ht.** Minimum Ht.* Maximum Ht.**
1839 (1840) - 3 Ft. 77.6" (1971mm) 78.9" (2004mm) 83.6" (2123mm) 84.9" (2156mm)1845 (1846) - 4 Ft. 87.6" (2225mm) 88.9" (2258mm) 93.6" (2377mm) 94.9" (2410mm)1849 (1851) - 4 Ft. 81.6" (2073mm) 82.9" (2106mm) 87.6" (2225mm) 88.9" (2258mm)1828 (1829) - 6 Ft. 82.6" (2098mm) 83.9" (2131mm) 88.6" (2250mm) 89.9" (2283mm)
*Minimum height = levelers in; minimum height to the work surface is 29.4" (747mm) for the 30.0" stand and 35.4" (899mm) for the 36.0" stand
**Maximum height = levelers out; maximum height to the work surface is 30.7" (780mm) for the 30.0" stand and 36.7" (932mm) for the 36.0" stand
BRO-CECA-BSCLAF-0207.qxd 06.02.2007 12:48 Uhr Seite 13
Thermo S
cientificForm
a Laminar Airflow
Console Workstations
Features and Technical Specifications
14
Laminar Airflow Consoles: Product Protection inEasy-to-Install, One-Piece Construction
Our horizontal laminar airflow console workstations,often referred to as clean benches, create clean airfor operations requiring a particle-free environment.These units meet requirements of Federal Standard209E for Class 100 (M 3.5) clean air.
Designed for Safety
The workstation’s design allows high velocitylaminar air to travel across the work surface andpast the operator. When various sized objects areplaced within the work area, the airflow does notpermit “backwashing” (i.e., contaminated outsideair will not drift back into the work environment).
• Low overall height permits easy passage throughdoorways and accommodates sites where ceilingheight is limited.
• All interior surfaces of the work area align withthe edge of the HEPA filter media to provide truelaminar airflow, preventing “picture framing” andbackwashing of contaminated air and ensuringyour product’s safety.
• Work surface and sidewalls are constructed of16 gauge Type 304 stainless steel for durabilityand easy cleaning.
• Blower/motor automatically compensates forfilter loading between annual certifications.
• Blower/motor switch, light switch, accessoryreceptacle, and receptacle for an optional UV light are located conveniently on the control panel.
• Built-in spill guard at back of the work areaprotects the HEPA filter from spilled liquids,preventing filter damage and prematurereplacement.
• Casters provide easy mobility for cleaning ormoving. Leveling feet are included for stabilitywhen positioned in a final location.
• Units can be factory modified with reverse airflowto accommodate centrifuges, automatedsamplers, and other aerosol producing equipment.Contact our Custom Products Department.
Carefully Directed Airflow
Intake air passes through a 1.0" (25mm) fiberglassprefilter. The blower/motor unit moves the airthrough a zero-probed, HEPA filter rated at 99.99%efficient for 0.3 micron particulates.
The HEPA filtered air is then directed horizontallyacross the work surface. Positive pressure,unidirectional laminar airflow prevents any inflow ofroom air contaminants onto the work surface.
LAMINAR AIRFLOWCONSOLESDesigned for lab proceduresassociated with the manipulation ofnon-hazardous materials, whilemaintaining a high quality environmentof Class 100 (M 3.5) HEPA filtered airwithin the work area
Ambient Air
HEPA Filtered Air
BRO-CECA-BSCLAF-0207.qxd 06.02.2007 12:48 Uhr Seite 14
15
Laminar Airflow Console Specifications
Models4 Ft. Console. . . . . . . . . 18525 Ft. Console. . . . . . . . . 18546 Ft. Console. . . . . . . . . 1856 (1857)
Work AreaWidth - 1852 . . . . . . . . . 48.3" (1227mm)Width - 1854 . . . . . . . . . 60.3" (1532mm)Width - 1856 (1857) . . . 72.3" (1836mm)Height . . . . . . . . . . . . . . 32.0" (813mm)Depth . . . . . . . . . . . . . . 21.0" (533mm)
Exterior Dimensions Width - 1852 . . . . . . . . . 52.0" (1321mm)Width - 1854 . . . . . . . . . 64.0" (1626mm)Width - 1856 (1857) . . . 76.0" (1940mm)Height . . . . . . . . . . . . . . 74.6" (1895mm)Depth . . . . . . . . . . . . . . 34.0" (864mm)
Electrical, Plug, Breaker, & Motor1852 . . . . . . . . . . . . . . . 120V, 60 Hz, 9.5 FLA1854/1856 . . . . . . . . . . . 120V, 60 Hz, 12.0 FLA1857 . . . . . . . . . . . . . . . 220V, 50 Hz, 11.0 FLA120V . . . . . . . . . . . . . . . NEMA 5-15P
Hospital Grade Plug220V . . . . . . . . . . . . . . . CEE 7/7 PlugBreaker Requirement . . 15 AmpMotor . . . . . . . . . . . . . . 1852: 1/3 HP
1854/1856: 1/2 HP1857: 3/4 HP
PenetrationsAll Models . . . . . . . . . . . 4, 2 on each sidewall
Unit Heat Load1852 . . . . . . . . . . . . . . . 3890 BTUH (1,140 Watts)1854/1856 . . . . . . . . . . . 4910 BTUH (1,440 Watts)1857 . . . . . . . . . . . . . . . 8260 BTUH (2,420 Watts)
WeightNet
1852 . . . . . . . . . . . . . . 470 lbs. (213.2 kg)1854 . . . . . . . . . . . . . . 550 lbs. (249.5 kg)1856 (1857) . . . . . . . . 610 lbs. (276.7 kg)
Shipping (Motor)1852 . . . . . . . . . . . . . . 590 lbs. (267.6 kg)1854 . . . . . . . . . . . . . . 680 lbs. (308.4 kg)1856 . . . . . . . . . . . . . . 775 lbs. (351.5 kg)1857 . . . . . . . . . . . . . . 800 lbs. (362.9 kg)
120V units are UL Listed to Canadian requirements. 220V, 50 Hz units and custom units are not UL Listed.
Our laminar airflow cabinet accessories allow you to create a complete workstation that provides comfort and convenience as well as functionality. All accessories are customer installed unless notedotherwise.
Ultraviolet (UV) Lights
UV Light Assemblies
Stock No. Description191075 15 Watt UV Light for 3 Ft. Model 1839191481 15 Watt UV Light for 3 Ft. Model 1840191076 30 Watt UV Light for 4, 5, and
6 Ft. Units
Portable UV Lights
Stock No. Description191069 15 Watt Portable UV Light for 3 Ft.
Model 1839191070 30 Watt Portable UV Light for 4, 5,
and 6 Ft. 120V Units
IV Rods (complete with 4 hangers each)
Stock No. Description191057 Rod for All Benchtops
(Model 1828 (1829) requires 2)191121 Rod for 5 Ft. Console Model 1854191227 Rod for 6 Ft. Console
Model 1856 (1857)191228 Rod for 4 Ft. Console Model 1852
Accessories for Laminar Airflow WorkstationsFeatures and Technical Specifications
BRO-CECA-BSCLAF-0207.qxd 06.02.2007 12:48 Uhr Seite 15
Accessories, continued
Portable Microscope Stand
Stand fits inside the workstation yet is independent of thecabinet. Table surface is free from vibration and protected byClass 100 (M 3.5) HEPA filtered air.
Stock No. Description191586 18.0" x 18.0" (457mm x 457mm)
Stainless Steel Platform, height isadjustable from 32.0" to 41.0" (813mm to 1041mm) in 1.0"(25mm) increments
Receptacles with Cover(s), factory installed
Stock No. Description191109 120V NEMA 5-15R Ground Fault Circuit
Interrupter (GFCI) Duplex Receptacle,right side
191110 120V Sidewall Mounted NEMA 5-15RDuplex Receptacle, right side
Additional Accessories
Stock No. Description191009 Plexiglas® Side Panel for Consoles,
factory installed191253 Service Valve Kit191055 Magnehelic Pressure Gauge,
factory installed191236 Storage Bin Kit for Consoles, attaches
beneath the work surface191127 Adjustable Footrest191486 Lab Chair with Arms, meets
Class 1,000 clean air specifications191487 Lab Chair without Arms, meets
Class 1,000 clean air specifications
Unmatched Laboratory Services
Our support continues after the point-of-purchase. Aworldwide network is ready to support your specific andunique needs. Some of the laboratory services offeredinclude the following:
Consultation CalibrationExtended Warranties InstallationPreventive Maintenance Temperature MappingReplacement Parts Proof of PerformanceRepair Services Qualification/ValidationTraining Datalogger Systems
North America: USA/Canada +1 866 984 3766 www.thermo.com/bscEurope: Austria +43 1 801 40 0, Belgium +32 2 482 30 30, Finland +358 9 329 100, France +33 2 2803 2000,Germany national toll free 08001-536 376, Germany international +49 6184 90 6940, Italy +39 02 95059 1, Netherlands +31 76 571 4440,Russia/CIS +7 095 225 11 15, Spain/Portugal +34 93 223 09 18, Switzerland +41 44 454 12 12, UK/Ireland +44 870 609 9203Asia: China +86 21 6865 4588 or +86 10 5850 3588, India +91 22 5542 9494, Japan +81 45 453 9220, Other Asian countries +852 2885 4613Countries not listed: +49 6184 90 6940 or +33 2 2803 2000 BRO-CECA-BSCLAF-0207
© 2007 Thermo Fisher Scientific Inc. All rights reserved. Minihelic is a registered trademark of Dwyer Instruments, Inc. Plexiglas is a registered trademark of Rohm & Haas Corporation. All other trademarks are theproperty of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms andpricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.
Thermo Fisher Scientific (NYSE: TMO) is the world leader in servingscience, enabling our customers to make the world healthier, cleaner andsafer. With annual sales of more than $9 billion, we employ 30,000 peopleand serve over 350,000 customers within pharmaceutical and biotechcompanies, hospitals and clinical diagnostic labs, universities, researchinstitutions and government agencies as well as environmental andindustrial process control settings. Serving customers through two premierbrands, Thermo Scientific and Fisher Scientific, we help solve analyticalchallenges from routine testing to complex research and discovery.
Thermo Scientific offers customers a complete range of high-endanalytical instruments as well as laboratory equipment, software, services,consumables and reagents to enable integrated laboratory workflowsolutions. Fisher Scientific provides a complete portfolio of laboratoryequipment, chemicals, supplies and services used in healthcare, scientificresearch, safety and education. Together, we offer the most convenientpurchasing options to customers and continuously advance ourtechnologies to accelerate the pace of scientific discovery, enhance valuefor customers and fuel growth for shareholders and employees alike. Visit www.thermofisher.com.