![Page 1: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/1.jpg)
GSFC· 2015
Thermal Hardware for Thermal Analysts
David Steinfeld
NASA Goddard Space Flight Center Code 545, Thermal Engineering
![Page 2: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/2.jpg)
Reason for This Course • There are 3 parts to Thermal Engineering:
1. Thermal Analysis 2. Thermal hardware installation 3. Thermal Vacuum Testing
• But many times Analysts are not involved in #2.
TFAWS 2015 – August 3-7, 2015 2
![Page 3: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/3.jpg)
Course Outline
• MLI Blanketing Theory 101 • MLI blanketing installation • Temperature Measurements • Heaters and Thermostats • Optical coatings (Paints and tapes) • Propulsion Systems (tanks, lines, and
thrusters)
TFAWS 2015 – August 3-7, 2015 3
![Page 4: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/4.jpg)
MLI Blanketing 101
TFAWS 2015 – August 3-7, 2015 4
Thermal Analyst: “The actual MLI doesn’t look like what’s in my Thermal Model”
Blanket Tech: “David, can you help me out? The Thermal Analyst
can’t tell me what he wants”
![Page 5: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/5.jpg)
Analyst vs. Hardware
TFAWS 2015 – August 3-7, 2015 5
TSS Model of PLASTIC Actual MLI on PLASTIC
STEREO/PLASTIC as an example
![Page 6: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/6.jpg)
Theoretical Blanket Effective Emissivity
-0.010
0.000
0.010
0.020
0.030
0.040
0.050
0 5 10 15 20 25 30
E-St
ar
Number of Layers
Kapton layers
VDA layers
TFAWS 2015 – August 3-7, 2015 6
![Page 7: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/7.jpg)
Actual MLI Blanket
0.000
0.010
0.020
0.030
0.040
0.050
0 5 10 15 20 25 30
E-St
ar
Number of Layers
VDA Effective Emissivity
Actual Blanket
Theoretical Blanket
TFAWS 2015 – August 3-7, 2015 7
![Page 8: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/8.jpg)
What affects MLI blanket ε*?
• Penetrations • Ground Straps • Crinkling • Stitching • Vents • Separator layers • Tightness • Cryogenic Temperatures • Atmospheric pressure
TFAWS 2015 – August 3-7, 2015 8
![Page 9: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/9.jpg)
What affects Optical Properties?
• Emissivity usually not effected. Solar Absorptance will be with age.
• Atomic oxygen effects outer layer – Silver Teflon needs to be 10 mil instead of 5 mil
thick in LEO
• Alpha increases with age (BOL vs. EOL)
TFAWS 2015 – August 3-7, 2015 9
![Page 10: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/10.jpg)
Touching Layers = Bad
• 1 ft2 blanket covering 30OC surface: – Good MLI blanket design = 1.2 watts lost – Smashed blanket = 38 watts lost
TFAWS 2015 – August 3-7, 2015 10
![Page 11: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/11.jpg)
Stitching Effects 1 ft wide blanket
0
0.02
0.04
0.06
0.08
0.1
0.12
0.14
0.16
0 1 2 3 4 5 6 7 8 9 10 11 12
E-St
ar
Distance (in)
SEAM SEAM
TFAWS 2015 – August 3-7, 2015 11
![Page 12: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/12.jpg)
Blankets Vent or Blow Up • Air Pressure on ground
– 14.7 psi – 2117 lbs per square foot. – But pressure in Space = 0 psi.
• Blankets usually go from Ground to Space (or inside T/V chamber)
– Air around MLI goes from 14.7 psi -> 0.
• MLI Blankets can only handle 0.1 psi (14.4 lbs per square foot). • Venting needed:
– Between MLI layers (or risk blowing up) – Between MLI and underlying metal (or risk blowing off surface) – Eliminate Gas conduction
TFAWS 2015 – August 3-7, 2015 12
![Page 13: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/13.jpg)
Generic Launch Pressure Inside Fairing
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0 20 40 60 80 100 120 140 160 180 200
Pres
sure
(psi
)
Time (Sec)
![Page 14: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/14.jpg)
Cryogenic Temperatures Affect MLI Blankets
0
0.002
0.004
0.006
0.008
0.01
0.012
-220 -200 -180 -160 -140 -120 -100 -80 -60 -40 -20 0
Effe
ctiv
e Em
issi
vity
Temperature (C)
Cold Temperatures effect MLI blanket efficiency
TFAWS 2015 – August 3-7, 2015 14
Emissivity shifts to the far infrared at very cold temperatures.
![Page 15: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/15.jpg)
Things Grow and Shrink
• Coefficient of Thermal Expansion – Things grow bigger when hot – Things shrink when cold – Aluminum shrinks/grows a lot compared to Kapton
• CTE = 0.000026 in/in OC • 72 inch piece, from -20 OC to +40 OC grows 1/8”
Metal
MLI Blanket Buttons
TFAWS 2015 – August 3-7, 2015 15
![Page 16: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/16.jpg)
Blanket Buttons, Etc…
TFAWS 2015 – August 3-7, 2015 16
Top hat Blanket buttons
Velcro
![Page 17: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/17.jpg)
ClickBonds (For heavier or thicker blankets)
TFAWS 2015 – August 3-7, 2015 17
![Page 18: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/18.jpg)
Bonding techniques • Buttons, Thermistors, Thermostats typically bonded with
Stycast 2850FT Cat 9 – Small bondline, so thermal resistance is low.
• Polymerics license required for bonding Flight hardware. • Surface preparation is key to a good bond:
– Clean surfaces – Abrade surfaces with sandpaper – Vacuum, then clean surface again – Hold down with Kapton until epoxy dries overnight.
• Think about how to handle vertical surfaces!
TFAWS 2015 – August 3-7, 2015 18
![Page 19: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/19.jpg)
Thermostats
• Typically bought from Honeywell. • Type 700 is typical thermostat style
TFAWS 2015 – August 3-7, 2015 19
Style 701 (standard) Style 717 (Prop lines)
![Page 20: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/20.jpg)
Heaters • Kapton Thermofoil Heaters • Applied with 3M Y966 Acrylic Adhesive
– Low outgassing – Y966 adhesive good to about +100OC
• Bond with Stycast Epoxy if hotter than +100OC, or watt density higher than 3.5 W/in2
– Overtaped with 3M 425 aluminum tape to help spread out heat.
TFAWS 2015 – August 3-7, 2015 20
![Page 21: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/21.jpg)
– Two thermostats wired in series • To prevent failed “on” condition
– Two heaters wired in parallel • To prevent failed “off” condition
– Heaters can be ordered with dual-elements • Cost is about the same as single element • Remember to order heaters with two color coded wires (to tell circuits apart)!
Heater-Thermostat Redundancy
-
thermostats
- Primary
Redundant
heater
heater thermostats
+
+
TFAWS 2015 – August 3-7, 2015 21
![Page 22: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/22.jpg)
Temperature Measuring • Thermocouple
– Cheap and easy. Voltage vs. Temperature • Remove after T/V testing or flyaway (snip and ground). • Type T or Type K. Make sure which one you are using! • Attach with 3M 425 Aluminum Tape
• Thermistor
– Non linear Ω vs. Temperature (negative slope) – Resistances 2252 Ω, 5K, 10K, etc…
• PRT
– Very linear Ω vs. Temperature (positive slope) – Usually used for high or low (cryogenic) temperature. – 4 wire variety enhances accuracy if needed (usually
cryogenic). Removes resistance of leads. – Resistances usually 100 Ω
TFAWS 2015 – August 3-7, 2015 22
Thermistor
PRT
![Page 23: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/23.jpg)
Thermal Enhancement • Nusil CV-2946
– 2-part material which needs to be mixed beforehand and degassed.
– Stored in a freezer or hardens in an hour
– Use Miller-Stephenson MS-143H as a release agent if needed. Teflon particles. Apply 3 layers.
• Arathane – mixed with 30-40% Boron Nitride also
good. – Cabasil makes it thick.
TFAWS 2015 – August 3-7, 2015 23
![Page 24: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/24.jpg)
Optical Coatings • Word of Advice: Never call an optical coating “Paint”!
• Things that effect Optical coatings:
1. Atomic Oxygen* 2. UV Radiation* 3. Proton-Electron particle Radiation 4. Contamination on the surface Note: * LEO orbits
• Example: Silver Telfon in LEO usually needs 10mil Teflon instead of 5 mil (AO erodes the Teflon)
TFAWS 2015 – August 3-7, 2015 24
![Page 25: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/25.jpg)
Optical Coatings, Page 2 • Thickness of the coating is key:
– Too thick makes the coating crack – Too thin effects the emissivity and solar absorptance
• Coating Selection – The Substrate: metal or composite? – Temperature range:
• Polyurethanes do not do well at hot temperatures. They turn brown. • Silicates work better when hot but have their own problems.
• Coat on flat side of the radiator, not on pocketed side if possible.
• Fillets and bolt patterns create 5-10X more time to coat. $$$$
• Talk to your Coatings Engineer before you get too far down the path.
TFAWS 2015 – August 3-7, 2015 25
![Page 26: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/26.jpg)
Propulsion Systems
TFAWS 2015 – August 3-7, 2015 26
![Page 27: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/27.jpg)
P P
Fuel Tank (MMH)
Oxidizer Tank (NTO)
P P
P
Helium HTK1 HTK2
F-H
FD-H3
CV-F
PV-BDN
CV-O PV-F1
FD-F1 FD-O1
FD-F2 FD-O2
F-O F-F
LV-FA LV-OA LV-FME1
LV-FME2
LV-OME1 LV-FB
LV-OME2
LV-OB
PV-FME PV-OME
ME
LV-R2 LV-R1
R1 R2
FD-H2
FD-H1
FD-HF FD-HO
R
R R
R
P
P P
P P
T-1A T-2A T-3A T-4A T-IB T-2B T-3B T-4B
PV-H1 PV-H2
PV-F2
PV-O1
PV-O2 FD-CVF FD-CVO
Helium
P-HTK
P-REG P-OTK P-FTK
P-FTA
P-FTB
P-OTB
P-OTA
P-FME P-OME
TFAWS 2015 – August 3-7, 2015 27
![Page 28: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/28.jpg)
Analyst vs. Hardware • Analyst:
1. SINDA model has heaters on all nodes of a prop line. 2. Use CALL HEATER subroutine for thermostat cycling. 3. Use e* of 0.05 for MLI
• Hardware: 1. Install Thermostats on Saddle Blocks. Pot terminals if necessary
Or buy 717 style Honeywell Thermostats.
2. Install thermostats/Saddle blocks on Prop Lines with Nusil and zip ties. 3. Wrap spiral Kapton heater around line 4. Hold down with 1 layer of 3M 425 Aluminum tape. 5. Apply 2nd layer of Aluminun tape 6. Add Thermocouple for T/V testing. 7. Wire everything up 8. Wrap MLI around pipe 9. Ground the MLI with its Ground Strap to structure
TFAWS 2015 – August 3-7, 2015 28
![Page 29: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/29.jpg)
Spiral Kapton Heaters for Prop Lines
![Page 30: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/30.jpg)
Saddle Blocks w/ integral thermostats
Prop Line
Nusil Zip-tie
Prop Line Tstats on Saddle Blocks
Honeywell Model Style 717
TFAWS 2015 – August 3-7, 2015 30
![Page 31: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/31.jpg)
Propellant Liquids • Monoprop: Hydrazine • Bi-Prop (Fuel + Oxidizer)
– Monomethyl Hydrazine (MMH) is the fuel – Nitrogen Tetroxide (NTO) is the oxidizer
• The freezing point can be lowered if you add nitric oxide. • The resulting oxidizer Mixed Oxides of Nitrogen (MON). • NTO has a freezing point of about -9OC • MON-3 (3% nitric oxide) freezes at -15OC • MON-25 (25% nitric oxide) freezes at -55OC
TFAWS 2015 – August 3-7, 2015 31
![Page 32: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/32.jpg)
Propulsion Module Plumbing
Low Pressure Control Module
Pressurant Supply
Fuel and Oxidizer Control Module
Fuel Pressurant Line
Fill and Drain Valve Bracket
High Pressure Control Module
Fuel Tank Liquid Line
Oxidizer Pressurant Line
Fuel Tank
TFAWS 2015 – August 3-7, 2015 32
![Page 33: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/33.jpg)
Propulsion Tanks •Aluminum Tape •Thermostats •Thermistors •Heaters •MLI blanketing
TFAWS 2015 – August 3-7, 2015 33
![Page 34: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/34.jpg)
Page D-34
Propulsion Line Supports • Plumbing lines are supported by thermally
isolating brackets and standoffs – Machined Ultem 1000 Or Ultem 1200UC – Brackets are bonded or bolted to the primary
structure
• Lines can be held with compliant clamps – Tefzel Cable ties may be used for off module
plumbing runs – common for commercial satellites
Ultem isolator/ bracket
Triana Propulsion Module
Line Clamp
¼” Propellant Line
Saddle Clamp
“Racetrack” tube spacer and Tefzel
Cable Tie TFAWS 2015 – August 3-7, 2015
34
![Page 35: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/35.jpg)
Page D-35
Fill and Drain Valve and Thruster Plumbing
ACS Thruster “A” Fuel Line
ACS Thruster “A” Oxidizer Line
ACS Thruster “B” Fuel Line
ACS Thruster “B” Oxidizer Line
ACS Thruster “A”
ACS Thruster “B”
Oxidizer F&D Valve (FD-O2) Fuel F&D Valve (FD-F2)
Pressurant Supply F&D Valve (FD-H1) Pressurant F&D downstream of PVs (FD-H2)
Oxidizer Tank Inlet (FD-O1)
Fuel Tank Inlet (FD-F1)
TFAWS 2015 – August 3-7, 2015 35
![Page 36: Thermal Hardware for Thermal Analysts - TFAWS 2020 · 2015-08-14 · Reason for This Course • There are 3 parts to Thermal Engineering: 1. Thermal Analysis 2. Thermal hardware installation](https://reader034.vdocuments.us/reader034/viewer/2022042410/5f287c347b5aa93c1611ac68/html5/thumbnails/36.jpg)
Course Summary
• Learned about “real” vs. theoretical MLI • Learned about “Actual” thermal hardware instead of
“Thermal Model” Hardware. – Their bonding techniques and materials.
• Learned about the special case of Propulsion Thermal.
TFAWS 2015 – August 3-7, 2015 36