Alarm Control System CA 62
The WinningCombination
C
Up to 12 zones
2 partitions
Opportunity for a hybrid security system
Direct and remote programming via PC
Wide range of detectors, communication and peripheral devices
СА 62 is the excellent security solution for homes, medium sized commercial premises and offices
Effective solution designed for maximum compatibility of prize and functionality
Technical Specifications of СА 62 Alarm Control Panel• Mains transformer - 17 VAC / 17 VA
• Accumulator charger - 13.8 V / 1A, electronic overload protection
• Backup power supply - accumulator battery 12 V / 7.2 Ah
• Current consumption - up to 100 mA for the control panel
• Power supply for detectors - 13.8 V / 1A, electronic overload protection
• Auxiliary devices power supply - 13.8 V / 1A, electronic overload protection
• Operation temperature range - from 0°C to +50°C
• Box - dimensions: 315 х 260 х 80 mm; material: plastic ABS; color: white
Peripheral Devices
Detectors
New•TITAN AG •TITAN DL•TITAN QD40
Range of infrared detec-
tors with analogue or
digital signal processing
algorithm.
Suitable for applica-
tions for storehouses or
residential buildings with
pet or other small animals
access, with weight up to
12/25/40kg.
New•TITAN MW •TITAN MW АМ
New•TITAN GB
Combined infrared and microwave detectors with digital signal processing algorithm.
TITAN MW AM has a special AntiMasking and AntiSpray functions, which makes it excellent choice for application in high level security areas - banking offices, safety vaults, trade storehouses
and buildings, etc.
TITAN MW AM covers the requirements of Grade 3.
Combined infrared and glass brake detector.
TITAN GB works with an optimized analogue
signal processing algorithm.
• GBD 10 • GBD 20 New•F10 •R20 GBD 10 and GBD 20 - glass
break detectors.
GBD 20 works with an improved digital signal processing algorithm, helping for the minimizing the false alarm signals in the system and detections breaking of 4 types of glass.
•S30•M40
Range of fire detec-
tors, designed to meet
all the requirements of
EN54-5/7, working with relay base B12.
Keyboards
LED 62 - NewLED Keyboard, 3 fast buttons for emergency situations, 1 programmable zone, sup-ports programming and control of two partition in the system.
LCD 63SE and LCD 64 - New LCD keyboards with blue icon display, 1 programmable zone, 1 button combination for sending of PANIC alarm message; indication for 12 zones and 2 partitions.
LCD63SE VG - performs also voice guide with 7 voice messages for system and alarm events.
Access Control
Remote Control
PR 62 - Proximity cards or key tags reader, detection distance - up to 10 cm, partial access control - arming and disarming the system, door opening.
MDU-V - Remote control module, rolling code, up to 15 transmitters in a set, 4 operation modes, easy and reliable work.
Serial Bus
Serial Bus
Key-Switch type zone
Sirens
SR 300 - New Outdoor piezo siren, option - integrated battery in the enclosure.
SR 105 - Indoor piezo siren, blue flash, impressively small dimensions.
Integrated tocontrol panel
Programmable outputs PGM
UWE 432 - New
Universal wireless receiver for wireless devices; up to 32
wireless devices AVA series; 4 zones. The UWE432 wire-
less receiver module is suitable for building of hybrid secu-
rity alarm systems - wired + wireless. The compatible AVA
wireless detectors are: magnetic contacts, sirens, infrared
detectors, remote controls and fire detectors.
General Features of СА 62 Alarm Control PanelInputs: • 5 inputs for connecting detectors.
Zones:
• Up to 12 zones with freely programmable parameters.
Doubling the zone number, by means of doubling zone connection, as 2 zones are situated in the keyboards.
• Individual setting for the balancing type of each input: 1 / 2 balancing resistors or zone doubling.
Partitions:• Two fully independent partitions.
• Automatic ARMING feature - automatic arming of the partitions for a programmed in advance time.
Outputs: • 3 weak current and 1 power current programmable outputs ОС type (open collector).
Codes: • 4 / 6 digit codes: 20 user codes (“Ambush code” function), 4 manager codes, 1 engineer code.
Events LOG: • Memory LOG for 256 events with time and date.
Report to aMonitoring
Station:
• Integrated PSTN digital communicator (Contact ID, SIA protocols).
• AjAx - LAN (TCP/IP) communication module.
• VD 60 - voice dialer.
Peripheral devices: • System control via LED and/or LCD keyboards models, and Proximity cards readers.
Default Configurations: • 4 default system configurations, for basic programming of 3 specific and 1 common configuration types of the panel.
Wireless Receiver
Programming
Programming Software:
• Remote - via telephone line or LAN;
• Via direct PC connection.PC Connection (USB)
Telephone line
Keyboard
Communication devices PSTN Communicator
Integrated to the control panel
digital communicator for com-
munication with central monitoring
station via telephone line. “Contact
ID” and “SIA” standard protocols
are supported.
VD 60
Voice dialer for transmitting of alarm
messages to the User.
8 alarm event messages up to 5
seconds each can be recorded and
then played in case of alarm event in
the system.
Integrated tocontrol panel
Serial Bus
Programmable outputs PGM
LED and LCD Keyboards - Wide range of key-
boards for programming and controlling the security
alarm system.
AjAx LAN Module - New
Communication module for transmitting of alarm event messages to a
Monitoring Station, SIA protocol, e-mail, and “e-mail to SMS”.
TP 2000 TransmitterLong range radio transmitter for transmitting of alarm event messages to a
monitoring Station.
Bidirectional wireless
communication with
AVA series devices
and detectors
Mobile phone
MonitoringStation (MS)
Please contact your local distributor and ask for the Teletek Electronics full colour Product catalogue.
Contact information:
www.teletek-electronics.com. e-mail: [email protected]
Address: 14A Srebarna Str., 1407 Sofia, Bulgaria, Tel.: (+359 2) 9694 800, 9694 744, Fax: (+359 2) 962 52 13
03
/20
09
СА 62 Alarm Control PanelOrder Information
Product Description Art. Number
Control Panel
CA 62 Alarm Control Panel, up to 12 zones, 2 partitions 31010031
Detectors
TITAN AG Analogue detector, PET Immunity - 12 kg, coverage area 1,5 - 15 meters 31060016
TITAN DL Digital detector, PET Immunity - 20 kg, coverage area 1,5 - 15 meters 31060039
TITAN QD 40 Digital detector, PET Immunity - 25/40 kg (selectable), coverage area 1,5 - 15 meters 31060023
TITAN MW Digital detector, combined - PIR + MW, coverage area 1,5 - 15 meters 31060029
TITAN MW AM Digital detector, combined - PIR + MW, AntiMasking and AntiSpray, coverage area 1,5 -15 meters 31060030
TITAN GB Analogue detector, combined - PIR + GB, coverage area 1,5 - 15 meters 31060035
GBD 10 Analogue glass brake detector, detection range 15 meters 31060001
GBD 20 Digital glass brake detector, AntiMasking function, detection range 7 meters 31060002
M40 Combined (multi sensors) detector - optical smoke and rate-of-rise temperature detector, class A1/R 31060028
B12 Fire base with relay output, 12V 31060034
Peripheral Devices
LED 62 LED keyboard, 12 zones, 2 partitions 31050024
LCD 63SE VG Icon LCD display keyboard, 12 zones, 2 partitions, voice messages - option 31050015
LCD 64 Icon LCD display keyboard, 12 zones, 2 partitions 31050025
PR 62 Proximity card and key tags reader 34010010
MDU-V Remote control module for Key-Switch type zones 40402002
Sirens
SR 105 Indoor piezo siren, blue flash, 105dB / 1 meter 40303029
SR 200 Outdoor siren, orange flash, 117dB / 1meter, IP65 32010046
SR 300O Outdoor piezo siren, orange flash, 105dB / 1 meter, IP54 32010049
SR 300B Outdoor piezo siren, blue flash, 105dB / 1 meter, IP54, integrated battery 32010048
Wireless Receivers
UWE 432 Wireless receiver module for AVA devices series. 31040059
Communication devices
VD 60 Telephone voice dialer module, integrated to the СА 62 configuration 31070007
AJAX LAN Communication module 31040052
Accessories
Proxi card Proximity card 40401006
Proxi tag Proximity key tag 40401013
PIR bracket Bracket for PIR mounting (wall or ceiling) 31070008
RC MDU-V Additional transmitter (remote control) for MDU-V 40402003
Kit AJAX AJAX LAN module programming kit: software, USB cable, operation manual 26000016