TECHNICAL SPECIFICATIONS
FOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
Catalog Number
Type
Date
Prepared By
Project
Phone (800) 523-3602 • Fax (215) 831-7703 • www.simkar.com08232013
HOUSING / LENS / OPTICS Die-cast aluminum housing in bronze finish with clear polycarbonate lens. Thermally efficient LED-specific housing with integrated heat sink fins provides for cooler operation and maximum LED operating life. Weatherproof silicone gasketing around lens and between backplate and housing seals out contaminants.
1.75" deep back plate DBS (standard 85W; optional on 30W and 58W units) provides an additional 1/2" top/bottom NPT as well as back knockout.
Angled LED mounting surface combined with integral 95% reflective MIRO 4™ reflector provides significantly more forward throw illumination than typical full cutoff LED wallpacks. Distribution is NEMA Type IV short.
LED Available in 3 light levels; 1900 lumens (30W), 3900 lumens (58W), and 5800 lumens (85W) at 4000K CCT; >80 CRI. LED operating life 50,000 hours L70. Light engines consist of 1, 2, or 3 chip-on-board arrays mounted direct to thermally efficient aluminum housing.
ELECTRICAL 120-277 VAC power supply with surge protection. Power factor is >0.9.
Power supply is mounted in direct contact with aluminum housing for cooler operation and longer life. Drive current is 700 mA. 30W units use one power supply; 58W units use two, and 85W units use three.
ACCESS / WIRING Housing includes 1/2" top/bottom NPT. Specify option DBS (standard on 85W units) for a 1.75” deep die cast back plate with 1/2” top/bottom NPT and back center knockout for conduit feed or sensors.
MOUNTING Standard backplate for mounting over a 4" recessed junction box. Backplates and housing utilize installed brackets to hold fixture during wiring. Back plate includes center knock out for conduit access and drill points. The recommended wall mounting height of the of the ARCL LED wallpack is 10 ft. to 24 ft. Fixture is designed to be installed in the downward facing position only.
WARRANTY 5 years
ArcLume LED Wallpack Ordering Information
Series Input Power Voltage Options
ARCL 30 = 30W58 = 58W 85 = 85W
U1 = 120-277V DBS = Deep backplate with top and bottom 1/2" NPT. Standard on 85W units.
(x)B = Button Photocell, designate voltage 1=120V; 2=277
INDUCTIONCFLHID LED
LEDFLUORESCENT
MADE IN THE UNITED STATES
The ArcLume LED wallpacks replace 100W to 250W metal halide wall-mounted fixtures while consuming up to 70% less energy and operating for 50,000 hours. The expected service life is more than 13 years of nighttime use.
ArcLume LED wallpack PerformanceModel Input Power Light Output* Mounting Height Replaces up to**
ARCL30U1 30W 1900 lumens Up to 10’ 100W MHARCL58U1 58W 3900 lumens Up to 14’ 175W MHARCL85U1 85W 5800 lumens Up to 24’ 250W MH
* Delivered lumens**Consult an application engineer for specific light levels
ArcLumeFull Cutoff Architectural
LED Wallpack
MIRO is a trademark of ALANOD
DARK SKY
RoHSC O M P L I A N T
TECHNICAL SPECIFICATIONS
Phone (800) 523-3602 • Fax (215) 831-7703 • www.simkar.comFOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
08232013
8.33
5 ”
0.81
5”
0.815”
7.52
”
5.59
3”2.
22”
7.52”
11.00”
2.22
”
1.7” 7.52”
With Standard Backplate
9.22
”1.
7”
7.52
”
With Optional Backplate DBS
5.59
3”
11.00”
Dimensions Shown with standard and optional backplate (DBS) optionArcLume
Full Cutoff Architectural LED Wallpack
TECHNICAL SPECIFICATIONS
Phone (800) 523-3602 • Fax (215) 831-7703 • www.simkar.comFOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
08232013
Photometric Data ARCL30U1
Photometric Data ARCL58U1
Photometric Data ARCL85U1
0
180
9090
3030
150150
6060
120120
500
1000
0
180
9090
3030
150150
6060
120120
2000
4000
0
180
9090
3030
150150
6060
120120
2000
4000
ZONAL LUMEN SUMMARY (NOMINAL; TOTAL FIXTURE LUMENS 1925)
Forward Light (1550 lumens) % total fixture lumens
Lumens% Total Lumens 80.6 1550Forward Low Zone (0 To 30 Degrees) % 16.4 316Forward Mid Zone (30 To 60 Degrees) % 44.8 862Forward High Zone (60 To 80 Degrees) % 18.9 364Forward Very High Zone (80 To 90 Degrees) % 0.4 8
Back Light (373 lumens) % total fixture lumensLumens
% Total Lumens 19.4 373Back Light Low Zone (0 To 30 Degrees) % 10.9 210Back Light Mid Zone (30 To 60 Degrees) % 7.4 142Back Light High Zone (60 To 80 Degrees) % 1.1 21Back Light Very High Zone (80 To 90 Degrees) % 0 0
ZONAL LUMEN SUMMARY (NOMINAL; TOTAL FIXTURE LUMENS 3900)
Forward Light (3120 lumens) % total fixture lumensLumens
% Total Lumens 80 3120Forward Low Zone (0 To 30 Degrees) % 16.6 647Forward Mid Zone (30 To 60 Degrees) % 45.1 1759Forward High Zone (60 To 80 Degrees) % 17.4 679Forward Very High Zone (80 To 90 Degrees) % 0.7 27
Back Light (784 lumens) % total fixture lumensLumens Lumens% Lumens 20.1 784Back Light Low Zone (0 To 30 Degrees) % 11.3 441Back Light Mid Zone (30 To 60 Degrees) % 7.9 308Back Light High Zone (60 To 80 Degrees) % 0.1 4Back Light Very High Zone (80 To 90 Degrees) % 0 0
ZONAL LUMEN SUMMARY (NOMINAL; TOTAL FIXTURE LUMENS 5800 )
Forward Light (4663 lumens) % total fixture lumensLumens
% Total Lumens 80.4 4663Forward Low Zone (0 To 30 Degrees) % 16.6 845Forward Mid Zone (30 To 60 Degrees) % 44.7 2593Forward High Zone (60 To 80 Degrees) % 18.7 1085Forward Very High Zone (80 To 90 Degrees) % 0.4 23
Back Light (1137 lumens) % total fixture lumensLumens Lumens% Lumens 19.6 1137Back Light Low Zone (0 To 30 Degrees) % 11.1 963Back Light Mid Zone (30 To 60 Degrees) % 7.6 441Back Light High Zone (60 To 80 Degrees) % 0.9 52Back Light Very High Zone (80 To 90 Degrees) % 0 0
ArcLumeFull Cutoff Architectural
LED Wallpack
TECHNICAL SPECIFICATIONS
Phone (800) 523-3602 • Fax (215) 831-7703 • www.simkar.comFOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
08232013
FL
FM
BL
BM 60°60°
30°30°
BACK LIGHT FORWARD LIGHT
BVH
UL
BH
UH UH
FVH
FH
UL
80°80°
100°100°
180°
90°90°
FRONTBACK
ZONE
L UMI NAI RE L UME NS
% OF L UMI NAI RE
L UME NS
F OR WAR D L I GHT 1053 56. 5
F L ( 0° - 30° ) 208 11. 2
F M ( 30° - 60° ) 428 23. 0
F H ( 60° - 80° ) 366 19. 7
F VH ( 80° - 90° ) 50 2. 7
B AC K L I GHT 777 41. 7
BL ( 0° - 30° ) 194 10. 4
BM ( 30° - 60° ) 330 17. 7
BH ( 60° - 80° ) 214 11. 5
BVH ( 80° - 90° ) 39 2. 1
UP L I GHT 32 1. 7
UL ( 90° - 100° ) 14 0. 8
UH ( 100° - 180° ) 18 1. 0
T R AP P E D L I GHT NA NA
BUG (Backlight, Uplight, Glare) Rating
(Type V, Area Light)Quadrilateral Symmetrical Luminaire Types
FL UX
B1 U2 G1
B1 U2 G1
(Type I, II, III, IV)
Asymmetrical Luminaire Types
Flux distribution based on IESNA Luminaire Classification System
Illustration depicts zone classification. See tables for fixture performance.
ARCL30
LumensSecondary Solid
Angle RatingBack LightBH (60-80 DEGREES) 20.4 B 0BM (30-60 DEGREES) 143.1 B 0BL (0-30 DEGREES) 210.7 B 1
Up LightUH (100-180 DEGREES) 0.0 U 0UL (90-100 DEGREES) 0.0 U 0
Glare LightFVH (80-90 DEGREES) 8.1 G 0BVH (80-90 DEGREES) 0.2 G 0FH (60-80 DEGREES) 364.5 G 0BH (60-80 DEGRESS) 20.4.3 G 0
IES BUG Rating: B1 U0 G0
ARCL58
LumensSecondary Solid
Angle RatingBack LightBH (60-80 DEGREES) 37.0 B 0BM (30-60 DEGREES) 308.9 B 1BL (0-30 DEGREES) 440.0 B 1
Up LightUH (100-180 DEGREES) 0.5 U 1UL (90-100 DEGREES) 0.9 U 1
Glare LightFVH (80-90 DEGREES) 25.8 G 1BVH (80-90 DEGREES) 0.3 G 0FH (60-80 DEGREES) 680.6 G 1BH (60-80 DEGRESS) 37.0 G 0
IES BUG Rating: B1 U1 G1
ARCL85
LumensSecondary Solid
Angle RatingBack LightBH (60-80 DEGREES) 53.3 B 0BM (30-60 DEGREES) 433.4 B 1BL (0-30 DEGREES) 633.9 B 2
Up LightUH (100-180 DEGREES) 0.4 U 1UL (90-100 DEGREES) 0.8 U 1
Glare LightFVH (80-90 DEGREES) 22.3 G 1BVH (80-90 DEGREES) 0.3 G 0FH (60-80 DEGREES) 1070.7 G 1BH (60-80 DEGRESS) 53.3 G 0
IES BUG Rating: B2 U1 G1
IES BUG ratings (backlight, uplight, glare) Per IES TM-15-11 ArcLumeFull Cutoff Architectural
LED Wallpack