www.usa.siemens.com/hvac
Variable Frequency Drives
C-1
Variable Frequency Drives
PRODUCT PRODUCT CODE RESOURCE DOCUMENTS PAGE #
Variable Frequency Drives
Introduction C-3
BT300 HVAC Drives BT300 154-126 C-5
BT300 HVAC Drives with Bypass Options BT300 C-15
Legacy SED2 Variable Frequency Drives SED2 154-042 C-19
Legacy SED2 Variable Frequency Drives with Bypass Options SED2 154-044, 154-041 C-23
Legacy SED2 Variable Frequency Drives SED2 154-062 C-29 NEMA Type 3R & Type 3R Harsh Environment Bypass
Accessories & Service Kits C-35
Table of Contents
NEW!
NEW!
www.usa.siemens.com/hvac
Variable Frequency Drives
C-3
Variable Frequency Drives
Siemens, a global leader in drives technology, is raising the bar with new BT300 Variable frequency Drives that are designed specifically for the demands of today’s HVAC systems. Increased focus on energy efficiency of variable flow systems has increased the need for easy-to-use and highly reliable variable frequency drives that reduce the cost of installation and maintenance while maximizing energy savings. Siemens Industry’s BT300 HVAC drives are designed to meet the demands of today’s HVAC systems. An increased focus on energy efficiency of variable flow systems has increased the need for easy-to-use and highly reliable variable frequency drives that reduce the cost of installation and maintenance while maximizing energy savings.
While constantly expected to do more with less, managing energy consumption and optimizing occupant comfort remains of utmost importance to facility managers. They also require products that will integrate seamlessly into existing equipment and building management systems. The highly efficient BT300 delivers all this and more.
The BT300 comes standard with unique and industry-leading features:
• View/Monitor nine parameters at one time – user selectable, users determine the parameters for their applications
• Thin Film Capacitors – eliminate the need to condition or reform the capacitors before applying power
• Smallest Type 12 footprint on the market – lower shipping cost and easy installation
• Motor Switch Ride Through – during maintenance the motor maintenance switch can be opened and closed without stopping or tripping the drive
Introduction
Varia
ble
Freq
uenc
y D
rives
www.usa.siemens.com/hvac
C-4
Our customer support teams are accessible and happy to assist you with ordering, fulfillment, and shipping questions. Call a representative at 1-800-516-9964 from 7 am to 5:30 pm (CST) Monday through Friday.
Contact Customer Support or your Account Executive with any questions. We appreciate your business and look forward to helping you!
We’re happy to assist you
www.usa.siemens.com/hvac
Variable Frequency Drives
C-5DescriptionSiemens Industry’s BT300 HVAC drives are designed to meet the demands of today’s HVAC systems. An increased focus on energy efficient variable flow systems has increased the need for easy-to-use and highly reliable variable frequency drives that reduce the cost of installation and maintenance while maximizing energy savings. HVAC demands are unique to other drive applications.
Features• Motor Switch Ride Through – during maintenance
the motor maintenance switch can be opened and closed without stopping or tripping the drive
• Thin Film Capacitors – eliminate the need to condition or reform the capacitors before applying power
• Intuitive graphical keypad with multilingual display• Monitor nine user-defined values at one time• Built-in wizards for faster start-up and easy setup of
advanced functions
• Built-in plain text help and maintenance manual shows possible causes and suggested remedies
• Real time clock allows up to five calendar-based schedules and three timer inputs
• Ready to communicate to a Building Management System, embedded RS485 and Ethernet HVAC protocols: BACnet IP, Modbus TCP, Modbus RTU, BACnet MSTP, Metasys N2, APOGEE® FLN
• Two built-in PID controllers enable fast and accurate process control
• Integrated harmonic filters on the DC link reduce noise and interference and eliminate the need for additional filters and reactors
• Built in fire mode controller• Energy Savings with > 97.5% efficiency• Optimized cooling fan runs only when needed• Belt failure detection with or without an external sensor
• Accepts a wide variety of digital and analog I/O types, including direct Ni 1000 RTD sensor level inputs
• One common interface throughout all power ranges • Two form C relays • RoHS Compliant • Smallest Type 12 footprint on the market – lower
shipping cost and easy installation
Options• LON Interface • Flange Mounting Kits for Frame Sizes 4-7
• Varnished I/O Option Boards• Door Mounting Kits
• PC Cable for NET Tool, USB to RS-485, cable length 9.8 ft. (3 m)• Real Time Clock Battery Package• SED2 to BT300 Migration Kits
BT300 Variable Frequency Drives
Energy &Atmosphere
BT300
Important Note: VFD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies representative at: 1.800.516.9964. BT300 Variable Frequency Drives
without and with Integral Disconnect.
Varia
ble
Freq
uenc
y D
rives
www.usa.siemens.com/hvac
C-6
Input Voltage and Power Ranges (3-phase)
208V - 240V, +/-10% ................................. .1 to 125 HP (0.75 to 90 kW) 380V - 480V, +/-10% ...............................1.5 to 250 HP (1.1 to 160 kW) Input Frequency ...................................................................... 45 to 66 HzOutput Frequency ................................................................... 0 to 320 HzFrequency Resolution .................................................................. 0.01 HzPower Factor ........................................................... 0.98 at Nominal LoadEfficiency ...................................................................................... >97.5% Overload Capacity ................. 1.1 x Nominal Rated Output Current 110%
for 1 Minute/10 Minutes
Peak Overload Capacity ............200% for 2 Seconds Every 20 Seconds Switching Frequency ....... 1.5 to 10kHz; Automatic Switching Frequency
Derating in Case of OverheatingShort Circuit Withstand Rating ............................................100,000 AIC Frequency Reference Analog Input .....0.01 Hz Resolution 0.1% (10-bit)Field Weakening Point ........................................................... 8 to 320 HzAcceleration/Deceleration Time ......................................0.1 to 3000 secAmbient Operating Temperature ........................ -14º F (-10º C) no Frost to 104º F (40º C) Without De-rating and 131º F (55º C) With De-ratingStorage Temperature ............................ -40º F (-40º C) to 158º F (70º C)Relative Humidity ............0 to 95% RH, Non-condensing, Non-corrosiveAir Quality ........................................................................ IEC 60068-2-60 Chemical Vapors.................IEC 60721-3-3, Unit in Operation, Class 3C3Mechanical Particles ..........IEC 60721-3-3, Unit in Operation, Class 3S2Altitude ........100% Load Capacity (no De-rating) up to 3,280 ft (1,000 m)
1% De-rating for Each 328 ft (100 m) Above 328 ft (1,000 m)Maximum Altitude 14,763 ft (4,500 m)
Vibration ..............................................IEC 61800-5-1 and IEC 60068-2-6Shock ..............................................IEC 61800-5-1 and IEC 60068-2-27Enclosures ............................................................ UL Type 1, UL Type 12EMC Immunity ..........Fulfills IEC 61800-3, First and Second Environment EMC Emissions...................................................................EN61800-3C2Average Noise level (Cooling Fan) Sound Level in dB(A) .....................FS4 - 65; FS5 - 61; FS6 and FS7: 68
FR8: 77; FR9: 78Agency Approvals .................................................UL 508C; CE, UL, cULAnalog Inputs ..................... 2 Voltage or Current (0-10Vdc, 0/4 to 20 mA)Analog Output ..........................................1 Selectable Voltage or Current Digital Inputs .............................................. 6 Programmable and Isolated Relay Outputs ................................................2 Form C; 1 Normally Open Auxiliary Input Voltage ................................24 Vdc +/-10% 250 mA Max.Auxiliary Input Voltage ...............................24 Vdc +/-10% 250 mA Max.,
Total of Both Outputs Control Method ........................................................Linear, Parabolic and
Programmable V/f; Flux Current Control Low-Power ModePWM Frequency .......... 2k Hz to 16k Hz (Adjustable in 2k Hz Increments)Fixed Frequencies ........................................................15 ProgrammableSkip Frequency Bands ...................................................3 ProgrammableEmbedded Resident Protocols .........................RS485 and Ethernet P1,
BACnet MS/TP, BACnet IP, Modbus RTU, Modbus TCP, Metasys N2, APOGEE FLN
Protection Features ...............Under-voltage and Over-voltage Trip Limit, Ground Fault, Mains Supervision, Motor Phase Supervision,
Over-current, Unit Over-temperature, Motor Overload, Motor Stall, Motor Underload, Short Circuit of +24V and +10V Reference Voltages
BT300 Specifications
Accessories & Service Kits C-35
www.usa.siemens.com/hvac
Variable Frequency Drives
C-7
BT300 Product Ordering
Your Product Number
Example Product Number B T 3 0 0 - 0 0 1 X 2 - 0 1 X
Example Product Number B T 3 0 0 - 0 0 1 5 4 - 1 2 D L
Model BT300 VFD only
HP 1, 1.5, 2, 3, 5, 7.5, 10, 15
20, 25, 30, 40, 50, 60, 75 100, 125, 150, 200, 250
X No Fract HP, 5 1/2 HP
Voltage 2 200 to 240 4 380 to 480
NEMA 01 UL Type 1 12 UL Type 12
Type X Drive Only D Disconnect Box – ONLY WITH TYPE 12
Options L LON Card Installed
Example Shown:BT300-001X2-01X = 1 HP, 208V Drive in Type 1 enclosure.BT300-00154-12DL = 1.5 HP, 480V Drive in Type 12 enclosure with an integral disconnect switch and LON card.
Varia
ble
Freq
uenc
y D
rives
www.usa.siemens.com/hvac
C-8
BT300 Output Ratings
Voltage (±10%)Product Number Output Rating Rated
Continuous Current
Frame SizeUL Type 1 UL Type 12
UL Type 12 with Drive Disconnect
HP kW
208V(3-Phase)
BT300-001X2-01X BT300-001X2-12X BT300-001X2-12D 1.0 0.75 4.8 FS4
BT300-00152-01X BT300-00152-12X BT300-00152-12D 1.5 1.1 6.7 FS4
BT300-002X2-01X BT300-002X2-12X BT300-002X2-12D 2.0 1.5 8.0 FS4
BT300-003X2-01X BT300-003X2-12X BT300-003X2-12D 3.0 2.2 11.0 FS4
BT300-005X2-01X BT300-005X2-12X BT300-005X2-12D 5.0 4.0 18.0 FS5
BT300-00752-01X BT300-00752-12X BT300-00752-12D 7.5 5.5 24.0 FS5
BT300-010X2-01X BT300-010X2-12X BT300-010X2-12D 10.0 7.5 31.0 FS5
BT300-015X2-01X BT300-015X2-12X BT300-015X2-12D 15.0 11.0 48.0 FS6
BT300-020X2-01X BT300-020X2-12X BT300-020X2-12D 20.0 15.0 62.0 FS6
BT300-025X2-01X BT300-025X2-12X BT300-025X2-12D 25.0 18.5 75.0 FS7
BT300-030X2-01X BT300-030X2-12X BT300-030X2-12D 30.0 22.0 88.0 FS7
BT300-040X2-01X BT300-040X2-12X BT300-040X2-12D 40.0 30.0 105.0 FS7
BT300-050X2-01X BT300-050X2-12X — 50.0 37.0 140.0 FS8
BT300-060X2-01X BT300-060X2-12X — 60.0 45.0 170.0 FS8
230V(3-Phase)
BT300-075X2-01X BT300-075X2-12X — 75.0 55.0 205.0 FS8
BT300-100X2-01X BT300-100X2-12X — 100.0 75.0 261.0 FS9
BT300-125X2-01X BT300-125X2-12X — 125.0 90.0 310.0 FS9
380V to 480V (3-Phase)
BT300-00154-01X BT300-00154-12X BT300-00152-12D 1.5 1.1 3.7 FS4
BT300-002X4-01X BT300-002X4-12X BT300-002X4-12D 2.0 1.5 5.3 FS4
BT300-003X4-01X BT300-003X4-12X BT300-003X4-12D 3.0 2.2 6.2 FS4
BT300-005X4-01X BT300-005X4-12X BT300-005X4-12D 5.0 4.0 10.6 FS4
BT300-00754-01X BT300-00754-12X BT300-00752-12D 7.5 5.5 13.2 FS4
BT300-010X4-01X BT300-010X4-12X BT300-010X4-12D 10.0 7.5 16.0 FS5
BT300-015X4-01X BT300-015X4-12X BT300-015X4-12D 15.0 11.0 23.0 FS5
BT300-020X4-01X BT300-020X4-12X BT300-020X4-12D 20.0 15.0 31.0 FS5
BT300-025X4-01X BT300-025X4-12X BT300-025X4-12D 25.0 18.5 38.0 FS6
BT300-030X4-01X BT300-030X4-12X BT300-030X4-12D 30.0 22.0 46.0 FS6
BT300-040X4-01X BT300-040X4-12X BT300-040X4-12D 40.0 30.0 61.0 FS6
BT300-050X4-01X BT300-050X4-12X BT300-050X4-12D 50.0 37.0 72.0 FS7
BT300-060X4-01X BT300-060X4-12X BT300-060X4-12D 60.0 45.0 87.0 FS7
BT300-075X4-01X BT300-075X4-12X BT300-075X4-12D 75.0 55.0 105.0 FS7
BT300-100X4-01X BT300-100X4-12X — 100.0 75.0 140.0 FS8
BT300-125X4-01X BT300-125X4-12X — 125.0 90.0 170.0 FS8
BT300-150X4-01X BT300-150X4-12X — 150.0 110.0 205.0 FS8
BT300-200X4-01X BT300-200X4-12X — 200.0 132.0 261.0 FS9
BT300-250X4-01X BT300-250X4-12X — 250.0 160.0 310.0 FS9
www.usa.siemens.com/hvac
Variable Frequency Drives
C-9
BT300 Type 1 and 12 Frame Sizes and Power Range
Volt
age KW 0.75 1.1 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160
HP 1 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250
208VF
ram
e S
ize
4 5 6 7 8 9 NA
480V N/A 4 5 6 7 8 9
BT300 Dimensions and Weights
Frame Size Height in. (mm)
Width in. (mm
Depth in. (mm
(without Disconnect)
Depth in. (mm
(with Disconnect)
Weight lb. (kg)
FS4 12.9 (328) 5.0 (128) 7.5 (190) 10.6 (270) 13.0 (6)
FS5 16.5 (419) 5.7 (144) 8.4 (214) 11.6 (294) 22.0 (10)
FS6 21.9 (557) 7.7 (195) 9.0 (229) 11.9 (302) 44.0 (20)
FS7 26.0 (660) 9.3 (237) 10.2 (259) 13.1 (332) 83.0 (37.5)
FS8 38.0 (966) 11.4 (290) 13.5 (343) N/A 145.5 (66)
FS9 45.3 (1150) 18.9 (480) 14.4 (365) N/A 238.0 (108)
Varia
ble
Freq
uenc
y D
rives
www.usa.siemens.com/hvac
C-10
BT300 Dimensions
128 (5.03)
100 (3.93)Ø7 (.27)
Ø13 (.51)
313
(12.
32)
100 (3.93)
328
(12.
91)
190 (7.48)
Type 1 / IP21
151
(5.9
4)
112
(4.4
0)
Type 12 / IP54
Ø25 (.98)
112
(4.4
0)
147
(5.7
8)
BT9080mm (in.)
Ø25 (.98)
FS4, Wall-Mount
FS5, Wall-Mount
www.usa.siemens.com/hvac
Variable Frequency Drives
C-11
BT300 Dimensions
195 (7.67)
148 (5.82)
Ø 15,5 (.61)Ø9 (.35)
557
(21.
92)
541
(21.
29)
Ø9 (.35) 148 (5.82)
229 (9.01)
43,7
(1.7
2)
148
(5.8
2)
151
(5.9
4)
Type 1 / IP21
Ø40 (1.57)
Ø33 (1.29)
Ø40 (1.57)
42(1
.65)
148
(5.8
2)
151
(5.9
4)
Type 12 / IP54 BT9082mm (in)
Ø25 (.98) Ø25 (.98)
259 (10.19)
Ø20 (.78)
660
(25.
98)
645
(25.
39)
237 (9.33)
190 (7.48) Ø9 (.35)Ø16 (.62)
Ø51 (2)
Type 1 / IP21
160
(6.2
9)
211
(8.3
0)
Type 12 / IP54
Ø25 (.98)
Ø50 (1.96)
160
(6.2
9)
217
(8.5
4)
9083bt
mm (in)
FS6, Wall-Mount
FS7, Wall-Mount
Varia
ble
Freq
uenc
y D
rives
www.usa.siemens.com/hvac
C-14
Use this Master HVAC Catalog and Siemens online ordering to maximize ordering efficiency. Go online to:
• Place orders• Browse this catalog online• Check product availability and pricing• Specify FREE valve tagging• Download invoices• Track shipments• Print out product information for submittals• Link to technical documentation• Download installation instructions• Create a reusable template order form for frequently ordered parts
See how easy it is to save time and money. Register today at:www.usa.siemens.com/buildingtechnologiesonlineordering
Online 24/7 ordering convenience
www.usa.siemens.com/hvac
Variable Frequency Drives
C-15DescriptionThe BT300 was designed from the onset with reliability in mind. The BT300 is the first VFD in today’s market which has utilized ALT testing from product design to production deployment.
However in today’s market, some customers want additional assurance their equipment will run regardless of the situation. To accommodate these situations, Siemens has developed a companion product for the BT300, the BT300 with Bypass Options.
As the word indicates, a “bypass” is defined in an engineering spec as a means of taking the drive out of the electrical power loop while keeping the HVAC system up and running.
BT300 is available with two types of bypass options. The BT300 with Conventional bypass is designed with 2 contactors and a service switch or the traditional 3-contactor configuration to bypass the drive, and incorporates selector switches and indicator lights to accomplish its primary functions. The second option, an Electronic bypass utilizes internal control boards that act as the brains and eliminates the control wiring, relay logic, terminal blocks and replaces them with advanced built-in features accessible from an electronic keypad.
Features• Contactors electronically interlocked• Advanced diagnostic board built into the bypass for
determining status of
– M1 and M2 contactors
– Overload – Customer supplied start/stop – Status of Essential Services
• Step-down transformer with fused primary and thermal fused secondary circuit
• Fused disconnect or circuit breaker Option • 100,000 AIC short circuit rating• Customer Supplied Terminal strip
Conventional Bypass Control:
• Drive test switch
• Drive-Off-Bypass selector• Bypass Light
• Fused disconnect or circuit breaker
• Optional 2-contactor with service switch or 3-contactor design (input, output and bypass)
Electronic Bypass Control
• Auto Bypass• Option to install 8 separate safety circuits• Fieldbus in Bypass
• Essential Service Mode (Fire mode) • Damper Interlock • Remote start via network
BT300 with Bypass Options
BT300
BT300 Variable Frequency Drives with Bypass Options.Energy &
Atmosphere
Important Note: VFD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies representative at: 1.800.516.9964.
Varia
ble
Freq
uenc
y D
rives
www.usa.siemens.com/hvac
C-16
Type 1 Bypass Approximate Weights
Frame Size 4 5 6 7 8 and 9
Weight lbs. (kg) 50 (23) 69 (31) 112 (51) 187 (85) 1000 (454)
BT300 with Bypass Options Product Ordering
Your Product Number
Example Product Number B T E - 1 2 5 X 4 - B 0 1 2 L
Model(s)
BTC Conventional BTE Electronic
HP
1, 1.5, 2, 3, 5, 7.5,10,15
20, 25, 30, 40, 50, 60, 75
100, 125, 150, 200, 250
X=no fract HP
5= 1/2 hp
Voltage
2 200 to 240
4 380 to 480
Disconnect
F Fused Disconnect
B Circuit Breaker Enclosure
01 Enclosure Type 1
Contactor
3 3 contactors (input/output and bypass contactors) (Conventional option only) 2 2 contactors bypass with service switch
Options
L Lon Card Installed
Example shown: BTE -125X4 -B012L BT300 Electronic Bypass, 480 volt, 125hp, Type 1, circuit breaker and 2 Contactor bypass witha service switch and LonWorks card installed in drive
BT300 Bypass Options Frame Sizes and Power Ranges
Volt
age KW 0.75 1.1 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160
HP 1 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250
208V
Fra
me
Siz
e
4 5 6 7 8 9 NA
480V N/A 4 5 6 7 8 9
www.usa.siemens.com/hvac
Variable Frequency Drives
C-17
BT300 Bypass Options Dimensions
4.000 1.49
6.76
.38 MOUNTING HOLESTYPICAL (4) PLACES
34.625
.38
35.48
1/2" CONDUIT HOLEWITH 3/4" KNOCKOUT RINGTYPICAL (5) PLACES
1.49 4.000
6.76
.38 MOUNTING HOLESTYPICAL (4) PLACES
.38
43.250
44.10
1/2" CONDUIT HOLEWITH 3/4" KNOCKOUT RINGTYPICAL (3) PLACES
3/4" CONDUIT HOLEWITH 1" KNOCKOUT RINGTYPICAL (2) PLACES
1.49 6.000
8.76
.44 MOUNTING HOLESTYPICAL (4) PLACES
53.750
.50
54.75
1/2" CONDUIT HOLEWITH 3/4" KNOCKOUT RINGTYPICAL (3) PLACES
1-1/4" CONDUIT HOLEWITH 1-1/2" KNOCKOUT RINGTYPICAL (2) PLACES
Frame Size 4
Frame Size 5
Frame Size 6
4.000 1.49
6.76
.38 MOUNTING HOLESTYPICAL (4) PLACES
34.625
.38
35.48
1/2" CONDUIT HOLEWITH 3/4" KNOCKOUT RINGTYPICAL (5) PLACES
1.49 4.000
6.76
.38 MOUNTING HOLESTYPICAL (4) PLACES
.38
43.250
44.10
1/2" CONDUIT HOLEWITH 3/4" KNOCKOUT RINGTYPICAL (3) PLACES
3/4" CONDUIT HOLEWITH 1" KNOCKOUT RINGTYPICAL (2) PLACES
Varia
ble
Freq
uenc
y D
rives
www.usa.siemens.com/hvac
C-18
BT300 Bypass Options Dimensions
4.18 6.000
14.16
.50 MOUNTING HOLESTYPICAL (4) PLACES
57.375
.50
58.50
1/2" CONDUIT HOLEWITH 3/4" KNOCKOUT RINGTYPICAL (3) PLACES
2" CONDUIT HOLEWITH 2-1/2" KNOCKOUT RINGTYPICAL (2) PLACES
.94 (4) PLACES
TYPICAL
1.28
29.409
29.409
TOP ENTRY, BLANK CONDUIT PLATES
32.58(TYPE 1 & 12)
90.71
1.18 TYPICAL
(4) PLACES
92.99
Frame Size 7 Frame Size 8 & 9
www.usa.siemens.com/hvac
Variable Frequency Drives
C-19
Legacy Variable Frequency Drives
Features• Built-in SBT P1 and JCI N2 (Metasys®) building
automation system protocols for easy network integration
• LON, Modbus RTU Interfaces optional• Low harmonics design reduces noise and interference;
eliminates need for filters/reactors in most installations • Built-in PID for fast and accurate pressure control • Pump staging for open loop, constant pressure, and
constant flow-type applications • Multi-level program access
SED2 Variable Frequency Drives Family.
Important Note: VFD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies representative at: 1.800.516.9964.
Options• LON Interface • Modbus RTU Interface• Advanced Operator Panel (AOP) Module• PC Kit
SED2
Energy &Atmosphere
• Belt failure detection with or without an external sensor
• Service mode for applications requiring continuous, uninterruptible operation
• Accepts a wide variety of digital and analog I/O types, including direct Siemens Ni 1000 RTD sensor level inputs
• One common interface throughout all power ranges • Optional Advanced Operator Panel for uploading/
downloading parameters
• Full form C relay contacts for digital outputs
Varia
ble
Freq
uenc
y D
rives
www.usa.siemens.com/hvac
C-20
Input Voltage and Power Ranges (3 phase)
208V and 230V to 240V, 3 ac±10% ...................................1 hp to 60 hp 380V to 480V, 3 ac ±10% .................................................1 hp to 125 hp
500V to 600V, 3 ac ±10% .................................................1 hp to 125 hp
Input Frequency .................................................................47 Hz to 63 HzOutput Frequency ..............................................................0 Hz to 150 HzPower Factor .......................................................................................≥0.9VFD degree of efficiency....................................................... 96% to 97%Switch-on Current .................................. Less than nominal input current
Auxiliary Supply 24V ....................... Glavanically separated, unregulated auxiliary supply (18V to 32V) 100 mA
Overload Capacity ...................................................110% for 60 secondsControl Method ..........................Linear, parabolic and programmable V/f;
and flux current control low-power modePWM Frequency ...........2k Hz to 16k Hz (adjustable in 2k Hz increments)Fixed Frequencies ........................................................ 15 programmable
Skip Frequency Bands ................................................... 4 programmable
Setpoint Resolution ............................................................0.01 Hz digital 0.01 Hz serial 10 bit analog
Digital Inputs (Sink/Source) ............................6: fully programmable and scalable isolated digital inputs, switchable
Analog Inputs ...............................................2: 0 to 10 Vdc, 0/4 to 20 mA, can also be configured as digital inputs
or Ni 1000 input
Relay Outputs .................................2: configurable 30 Vdc/5A (resistive), 250 Vac/2A (inductive)
Analog Outputs .................................2: programmable (0/4 mA to 20 mA, or 0 Vdc to 10 Vdc)
Serial Interface .................................................RS-485 transmission rate: Up to 38.4k Baud Protocols: USS, P1 and N2
Protection Level................................................................................. IP20 NEMA Type 1 with protective shield and gland plate installed
Temperature Ranges ..............Operating: 14°F to 104°F (–10°C to 40°C) Storage: –40°F to 158°F (–40°C to 70°C)
Humidity ..............................................................95% rh, non-condensingOperational Altitudes .............................................Up to 3280 ft (1000m)
above sea level without derating
Protection Features ....................Under-voltage, Over-voltage, Overload, Ground fault, Short circuit, Stall prevention,
Locked motor, Motor overtemperature l2 t PTC, Over-temperature, Parameter PIN protection.
Standards ................................................................... UL, cUL, CE, C-tickCE Conformity ......Conformity with EC Low Voltage Directive 73/23/EECOptions .........................................LON Interface, Modbus RTU Interface,
BACnet MS/TP Interface, Advanced Operator Panel (AOP) Module, PC Kit
Variable Frequency Drives Specifications
Notes: Example Shown:
1. Available only with Voltage Codes 3 and 4. SED2-0.75/22X = SED2 VFD only, 0.75 kW (1 hp), 200 to 240V, open type IP20.
Model SED2- VFD only
kW rating
0.75, 1.1, 1.5, 2.2, 3, 4, 5.5, 7.5, 11, 15, 18.5, 22, 30, 37, 45, 55, 75, 90 [See Note 1 for these selections]
Voltage 2 200 to 240V 3 380 to 480V 4 500 to 600V
NEMA rating 2 (IP 20) 1 NEMA Type 1
Filter X Factory Required Designator
(Uses 2 to 4 spaces plus a divider “/”)
Your Product Number
Example Product Number S E D 2 - 0 . 7 5 / 2 2 X
Variable Frequency Drives Product Ordering
www.usa.siemens.com/hvac
Variable Frequency Drives
C-21
Variable Frequency Drives Dimensions and Weights
Variable Frequency Drives Frame Sizes
IP20 SED2 VFDs
Frame Size Height Width Depth Weight Lb. (kg)
A 6.8 (173) 2.9 (73) 5.9 (149) 2.9 (1.3)
B 8.0 (202) 5.9 (149) 6.8 (172) 7.5 (3.4)
C 9.6 (245) 7.3 (185) 7.7 (195) 12 (5.5)
D 20.5 (520) 10.8 (275) 9.6 (245) 35 (16)
E 25.6 (650) 10.8 (275) 9.6 (245) 44 (20)
F 33.5 (850) 13 (350) 12.6 (320) 116 (53)
NEMA Type 1 SED2 VFDs Assembled with Protective Shield and Gland Plate
Frame Size Height Width Depth Weight Lb. (kg)
A 9.1 (231) 2.9 (73) 5.9 (149) 3.2 (1.5)
B 11.8 (300) 5.9 (149) 6.8 (172) 8.3 (3.8)
C 13.8 (351) 7.3 (185) 7.7 (195) 13.6 (6.2)
D 24.6 (625) 10.8 (275) 9.6 (245) 37.5 (17)
E 29.7 (754) 10.8 (275) 9.6 (245) 46.4 (21)
F 54.5 (1384) 16.0 (406) 14.0 (356) 200 (91)
SED2 IP20 and NEMA Type 1 Frame Sizes and Power Ranges
HP 1 1.5 2 3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 125
kW .75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
240V A B C D E F N/A
480V A B CD E F
575V CVFD
0163
R1
Varia
ble
Freq
uenc
y D
rives
www.usa.siemens.com/hvac
C-22
This handy online feature stores all your past and current orders online for quick and easy reference. The Order Tracker function lets you access information such as:
• Ordered By • Date Placed• Order No. • Acknowledgement of Order• Shipping Date • Shipment Tracking
To view your history and status, register online atwww.usa.siemens.com/buildingtechnologiesonlineordering
Online order tracking
www.usa.siemens.com/hvac
Variable Frequency Drives
C-23
Legacy Variable Frequency Drives with Bypass Options
Bypass Power3-Contactor: Input, Output, & Bypass• Overload protection in bypass mode• Step-down transformer with fused primary and secondary• Contactors electrically and mechanically interlocked• Drive test function• Complete electrical isolation of drive
Input Device• Fused disconnect• Circuit breaker (optional)• All doors are interlocked and padlockable
Reactor Options• Input line reactor mounted in bypass option enclosure. • Line reactor supplied separately.• Load reactor (in NEMA 1/3R enclosure) supplied separately.
E-Bypass ControlAuto Bypass• Relay logic allows user to send the motor to bypass
mode based on the drive’s programmable relay.• The drive’s programmable relay, typically set to fault,
can be set up for applications that run full speed for an extended period of time.
Enable Input• Generally used for safety tie-ins; the motor will not
operate the drive or bypass when open.
Common Remote Start/Stop• Common remote start/stop can be used in both drive
and bypass mode.
Essential Services Mode• Also used for smoke purge; the motor goes to bypass
regardless of the selected mode.• No call to stop will have an effect, including open safety
or stop commands.• Only turning the power off or opening this contact will
stop the motor.
Conventional Bypass ControlEnable Input• Generally used for safety tie-ins; the motor will not
operate the drive or bypass when open.
Essential Services Mode• Typically used for smoke purge; the motor goes to
bypass regardless of the selected mode.• No call to stop will have an effect, including open safety
or stop commands.• Only turning the power off or opening this contact will
stop the motor.
Conventional Bypass – Door Mounted Control Devices • Drive-Off-Bypass selector • Bypass pilot light• Drive Test on/off selector
SED2 Variable Frequency Drives with Conventional Bypass Options Family.
Important Note: VFD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies representative at: 1.800.516.9964.
SED2
Drive
Motor
2 Contactor Bypass
InputDevice
Drive
Motor
3 Contactor Bypass
InputDevice
VF
0302
R1
Energy &Atmosphere
Varia
ble
Freq
uenc
y D
rives
www.usa.siemens.com/hvac
C-24
Electronic Bypass SpecificationsInput Voltage (3-phase)
208V, 3 AC±10% .........................1 hp to 60 hp (2.3 amps to 154 amps) 240V, 3 AC±10% .........................1 hp to 60 hp (2.3 amps to 154 amps) 480V, 3 AC ±10% ......................1 hp to 125 hp (1.2 amps to 178 amps) 575V, 3 AC ±10% ......................1 hp to 125 hp (2.3 amps to 125 amps)Protection Level...................................................................NEMA Type 1Digital Inputs
Six Digital Inputs as follows ..........Remote start input, Remote safety 1, Remote safety 2, Interlock start,
Essential services, Overload trigger. Inputs require a contact closure capable of providing a
low impedance path at currents less than 20 mA. Relay/Digital Outputs
Six Relay/Digital Outputs as follows ........................................VFD fault, Programmable output, Drive select, Bypass select,
Running on bypass, Overload fault, Each relay has a maximum rating of 2A at 120Vac.
Conventional Bypass SpecificationsInput Voltage (3-phase)
208V, 3 AC±10% .........................1 hp to 60 hp (2.3 amps to 154 amps) 240V, 3 AC±10% .........................1 hp to 60 hp (2.3 amps to 154 amps) 480V, 3 AC ±10% ......................1 hp to 125 hp (1.2 amps to 178 amps) 575V, 3 AC ±10% ......................1 hp to 125 hp (2.3 amps to 125 amps)Protection Level...................................................................NEMA Type 1 Temperature
Operating......................................................... 32 to 104°F (0 to +40°C) Storage ......................................................-40 to +158°F (-40 to +70°C)Humidity .....................................................0 to 95% RH, non-condensing
Variable Frequency Drives with Conventional Bypass Option Specifications
Accessories & Service Kits C-35
E-Bypass — Door Mounted Control Devices
VFD Bypass
STOPRESET
InputOn/Off
Enable
InputContactor
OutputContactor
BypassContactor
VFD
HandStart
RemoteStart
INTERLOCK START LOGICEnable Commanded Proofed
Auto Bypass Enabled
Essential Services
VFD Fault
Safety Fault
Overload Fault
VF
D00
97R
2
OverloadRelay
Motor
www.usa.siemens.com/hvac
Variable Frequency Drives
C-25
Notes:
1. Available only with Voltage Codes 3 and 4. 2. Input line reactors will be installed in bypass enclosures. Load reactors are supplied seperately in NEMA 1 or
NEMA 3R enclosures.
Example shown: VBA340.B133XVBA Conventional Bypass, 40 HP, 480V, Circuit Breaker, NEMA Type 1, 3-Contactor Bypass with Input Line Reactor.VBE340.F130X VBE Electronic Bypass, 40 hp, 480V, fused disconnect, NEMA Type 1, 3 contactors bypass, no reactor.
Legacy Variable Frequency Drives with Conventional Bypass Option Product Ordering
Your Product Number
Example Product Number V B A 3 4 0 . B 1 3 3 X
Model VB VFD with an Extended Box
Series A Conventional Bypass E Electronic Bypass
Voltage 1 208 V 2 230 to 240 V 3 380 to 480 V 4 500 to 600 V
HP rating 1.0, 1.5, 2.0, 3.0, 4.0, 5.0, 7.5, 10, 15, 20, 25, 30, 40, 50,
60, 75, 100, 125 [See Note 1 for these selections]
Disconnect F Fused Disconnect B Circuit Breaker
NEMA rating 1 NEMA Type 1
Contactor 3 3 Contactors (Input, output, and bypass contactors) 0 None (Extended box only. No bypass.)
Reactor [See Note 3] 0 None 3 Line Reactor Filter X Factory Required Designator
Varia
ble
Freq
uenc
y D
rives
www.usa.siemens.com/hvac
C-26
Frame Size Wt. Lb (kg)
A 45 (20)
B 55 (25)
C 75 (34)
D 150 (68)
E 180 (82)
F 470 (213)
Note: Exact weight will be affected by the actual horsepower/voltage and the selected power options.
HP kW 208/240V 480V 575V
1 .75 A
A
C
1.5 1.1
B2 1.5
3 2.2B
5 4
C7.5 5.5
C10 7.5
15 11
D20 15
25 18.5
D D30 22 E
40 30
F50 37E E
60 45
75 55
N/A FF100 75
125 90
HA1 — N/A
NEMA 1 Bypass Approximate Weights
NEMA 1 Bypass Frame Sizes and Power Ranges
www.usa.siemens.com/hvac
Variable Frequency Drives
C-27
NEMA 1 Dimensions
DepthWith
Handle9.6 (24)
DepthWith
Handle12.2 (31)
DepthWith
Handle9.6 (24)
13.2(34)
34(86)
48(122)
11.5(29)
Frame SizeA and B
Frame Size C
12.4(31)
10.5 TYP(27)
10.6(27)
11 TYP(28)
20.8(53)
DepthWith
Handle10.4 (26)
53.5(136)
Frame Size D
19.9(51)
11.5 TYP(29)
1.5(3.8)
1.5(3.8)
2(5)
2(5)
4(10)
3.4(8.6)
57.5(146)
45.5(116)
Depth17.4(44)
Frame Size FFrame Size E
20.8(53)
58.5(149)
19.9(51)
10 TYP(25)
5.5(14)
3(7.6)
2.9(7.4)
2.9(7.4)
1(2.5)
VF
D01
27R
2
= Protective Shield
DepthWith
Handle9.6 (24)
DepthWith
Handle12.2 (31)
DepthWith
Handle9.6 (24)
13.2(34)
34(86)
48(122)
11.5(29)
Frame SizeA and B
Frame Size C
12.4(31)
10.5 TYP(27)
10.6(27)
11 TYP(28)
20.8(53)
DepthWith
Handle10.4 (26)
53.5(136)
Frame Size D
19.9(51)
11.5 TYP(29)
1.5(3.8)
1.5(3.8)
2(5)
2(5)
4(10)
3.4(8.6)
57.5(146)
45.5(116)
Depth17.4(44)
Frame Size FFrame Size E
20.8(53)
58.5(149)
19.9(51)
10 TYP(25)
5.5(14)
3(7.6)
2.9(7.4)
2.9(7.4)
1(2.5)
VF
D01
27R
2
= Protective Shield
Dimensions shown in inches (mm).
Varia
ble
Freq
uenc
y D
rives
www.usa.siemens.com/hvac
C-28
Our customer support teams are accessible and happy to assist you with ordering, fulfillment, and shipping questions. Call a representative at 1-800-516-9964 from 7 am to 5:30 pm (CST) Monday through Friday.
Contact Customer Support or your Account Executive with any questions. We appreciate your business and look forward to helping you!
We’re happy to assist you
www.usa.siemens.com/hvac
Variable Frequency Drives
C-29
Legacy VFD NEMA Type 3R & Type 3R Harsh Environment (3RHE) Bypass
FeaturesBypass Power3-Contactor: Input, Output, and Bypass • Overload protection in bypass mode. • Step-down transformer with fused primary
and secondary. • Contactors electrically and mechanically interlocked. • Drive test function. • Complete electrical isolation of drive.
Input Device• Fused disconnect. • All doors are interlocked and padlockable.
Reactor Options
• Line reactor mounted in bypass enclosure. • Line reactor supplied separately
(in NEMA Type 3R enclosure). • Load reactor supplied separately.
Bypass – Door Mounted Control Devices
• Drive-Off-Bypass selector • Bypass pilot light• Drive Test On-Off selector
SED2 Variable Frequency Drives NEMA Type 3R Bypass.
Important Note: VFD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies representative at: 1.800.516.9964.
SED2
Energy &Atmosphere
Varia
ble
Freq
uenc
y D
rives
www.usa.siemens.com/hvac
C-30
Input Voltage (3 phase) .............................................. 208V, 3 AC ±10% * 240V, 3 AC ±10% *
480V, 3 AC ±10% 575V, 3 AC ±10%*
* Not available in the 3RHE modelsProtection Level ...............................................................NEMA Type 3RTemperature
Operating.............14°F to 104°F (–10°C to 40°C), HT1 to 122°F (50°C) Storage .................................................–40°F to 158°F (–40°C to 70°C)High-Temperature Model (HT1 and HT2)
Operating................................................14°F to 122°F (–10°C to 50°C) Storage ................................................ –40°F to 158°F (–40°C to 70°C)Humidity .......................................................0 to 95% rh, non-condensing
NEMA Type 3R/3RHE Bypass Specifications
www.usa.siemens.com/hvac
Variable Frequency Drives
C-31
VFD NEMA Type 3R & Type 3R Harsh Environment (3RHE) Bypass Product Ordering
Your Product Number
Example Product Number V B A 3 4 0 . F 3 3 0 X H E 2
Model VB VFD with an Extended Box
Series A Conventional Bypass
Voltage 1 208 V 2 230 to 240 V 3 380 to 480 V 4 500 to 600 V
HP rating 1.0, 1.5, 2.0, 3.0, 4.0, 5.0, 7.5, 10, 15, 20, 25, 30, 40, 50, 60, 75, 100, 125 [See Note 1 for these selections]
Disconnect F Fused Disconnect
NEMA rating 3 NEMA Type 3R
Contactor 0 None 3 3 Contactors (Input, output, and bypass)
Reactor [See Note 2] 0 None 3 Line Reactor
Filter X Factory Required Designator
Options (If no option is required, leave field blank) HT1 High Temperature [See note 3] HE2 Harsh Enviroment Nema 3R [See note 4] HT2 Harsh Enviroment Nema 3R — High Temperature Rating [See note 5]
Notes:
1. Available only with Voltage Codes 3 and 4. 2. Input line reactors will be installed in bypass enclosures. Load reactors are supplied seperately in NEMA 1 or
NEMA 3R enclosures.3. HT1 (122°F, 50°C) is not available for all ratings. 208V and 230 to 240V to 3 hp are all HT1; 480V to 5 hp are all HT1. 4. HE2 available only with Voltage Codes 3 and 4. (480V to 40 hp) 5. HT2 (122°F, 50°C) is not available for all ratings. 480V to 5 hp are all HT2
Example Shown:VBA340.F330XHE2 VBA Conventional Bypass, 480V, 40 hp, fused disconnect, NEMA Type 3R, 3 contactors, no reactor, harsh environment.
Varia
ble
Freq
uenc
y D
rives
www.usa.siemens.com/hvac
C-32
DEPTH = 11-1/2 (292)
ENCLOSURE FRAME ABC ENCLOSURE FRAME DE
DEPTH = 12-1/2 (318)
ENCLOSURE FRAME F
DEPTH = 16-1/2 (419)
MOUNTING CLEARANCE FOR PROPER AIRFLOW:LEAVE 1 FOOT (305 mm) BETWEEN THE NEMA TYPE 3R BYPASS AND ANY ADJACENTSOLID STRUCTURE THAT IS NOT USED FORMOUNTING PURPOSES.
LEAVE 3 FEET (914 mm) BETWEEN THE NEMA TYPE 3R BYPASS AND ANY OTHER NEMA TYPE 3R BYPASS OR VFD.
34 (864)
75(1905)
74-1/8(1882)
58 (1473)
42 (1067)
46 (1169)
57(1448)
56-1/8(1425)
30 (762)
18 (457)
28-1/2 (724)
30 (762)
VF
D01
78R
2
NEMA Type 3R Enclosure Dimensions
Dimensions shown in inches (mm).
34(848)
18(457)
29(724)
30(756)
VF
D02
22R
1
Enclosure Frame ABC Enclosure Frame DE Enclosure Frame F
Enclosure Frame B Enclosure Frame C Enclosure Frame D
VF
D02
25R
1
42(1051)
26(660)
50(1272)
51(1288)
VF
D02
28R
1
44(1099)
28(711)
56(1424)
57(1440)
Depth = 10 Inches Depth = 11 Inches Depth = 14 Inches
Depth = 11-1/2 Inches (292)
Depth = 12-1/2 Inches (318)
Depth = 16-1/2 Inches (419)
NEMA Type 3RHE Enclosure Dimensions
www.usa.siemens.com/hvac
Variable Frequency Drives
C-33
NEMA Type 3R Bypass Non-HT1 Enclosure Frame Sizes and Power Ranges
HP 1 1.5 2 3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 125
kW .75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
208/240V(Rated as HT1,
High Temperature package)ABC DE F N/A
480V(Rated as HT1,
High Temperature package)ABC DE F
575V ABC DE F
VF
D01
79R
2
NEMA Type 3R Bypass HT1 Enclosure Frame Sizes and Power Ranges
HP 1 1.5 2 3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 125
kW .75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
208/240V ABC DE F N/A
480V ABC DE F N/A
575V ABC DE F N/AVF
D01
80R
2
NEMA 3RHE Bypasses HE2 Frame Sizes and Power Ranges
HP 1 1.5 2 3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 125
kW .75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
208/240V N/A
480V N/A C D N/A
575V N/AVF
D01
80R
2
NEMA 3RHE Bypasses HT2 Frame Sizes and Power Ranges
HP 1 1.5 2 3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 125
kW .75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
208/240V N/A
480V N/A B C D N/A
575V N/AVF
D01
80R
2NEMA Type 3R and 3RHE Approximate Weights
3R Frame Size Wt. Lb (kg)
ABC 130 (59)
DE 300 (136)
F 550 (249)
Note: Exact weight will be affected by actual horsepower/voltage and selected power options
3RHE Frame Size Wt. Lb (kg)
B 150 (68)
C 220 (100)
D 330 (150)
Varia
ble
Freq
uenc
y D
rives
www.usa.siemens.com/hvac
C-34
Use this Master HVAC Catalog and Siemens online ordering to maximize ordering efficiency. Go online to:
• Place orders• Browse this catalog online• Check product availability and pricing• Specify FREE valve tagging• Download invoices• Track shipments• Print out product information for submittals• Link to technical documentation• Download installation instructions• Create a reusable template order form for frequently ordered parts
See how easy it is to save time and money. Register today at:www.usa.siemens.com/buildingtechnologiesonlineordering
Online 24/7 ordering convenience
www.usa.siemens.com/hvac
Variable Frequency Drives
C-35
PRODUCT PAGE #
BT300
PC Cable for Software Tools C-36
Real Time Clock Battery Package C-36
Door Panel Kit C-36
Hand Held Panel Kit C-36
Flange Mounting Kits C-36
Varnished Option Boards C-37
SED2 to BT300 Migration Kits C-38
SED2
PC Kit C-39
Mounting Hardware C-39
Filter Kits C-39
Operator Panel C-39
LON Interface Option C-40
Modbus Interface C-40
Accessories & Service Kits
Table of Contents
NEW!
Varia
ble
Freq
uenc
y D
rives
www.usa.siemens.com/hvac
C-36
Accessories and Service Kits
Description Part No.
BT300
PC Cable for Software Tools, USB to RS-485, 3m BT300-CABLE
Battery package, 5 pcs BT300-BATTERY
Door Panel Kit, Drive Side IP54 Protected, 3m BT300-PANEL-N12
Hand Held Panel Kit BT300-HHPANEL
Flange Mounting Kit, for FS4 BT300-FLG-FS4
Flange Mounting Kit, for FS5 BT300-FLG-FS5
Flange Mounting Kit, for FS6 BT300-FLG-FS6
Flange Mounting Kit, for FS7 BT300-FLG-FS7
www.usa.siemens.com/hvac
Variable Frequency Drives
C-37
Description Part No.
BT300
6 X DI/DO, Programmable BT300-OPT-B1-V
2 X RO + Thermistor BT300-OPT-B2-V
1 X AI, 2 X AO (Isolated) BT300-OPT-B4-V
3 X RO BT300-OPT-B5-V
1 X RO, 5 X DI (42-240VAC) BT300-OPT-B9-V
LonWorks BT300-OPT-C4-V
1xAO, 1xDO, 1xRO BT300-OPT-BF-V
NI1000 Sensor Card BT300-OPT-BH-V
Varia
ble
Freq
uenc
y D
rives
www.usa.siemens.com/hvac
C-38
Description Part No.
BT300
SED2 208V to 3HP 480V to 5HP SED2-BT300-AB-4
SED2 208V to 4HP 480V to 7.5HP SED2-BT300-C-4
SED2 208V to 10HP 480V to 20HP SED2-BT300-C-5
SED2 208V 15 to 20hp 480V 25 to 40hp SED2-BT300-D-6
SED2 208V 25hp SED2-BT300-D-7
SED2 208V 30hp 480V 50 to 60hp SED2-BT300-E-7
SED2 FSC to BT300 Remote Mount SED2-BT300-C-R
SED2 FSD and FSE to BT300 Remote Mount SED2-BT300-DE-R
SED2 208V 40hp 480V 75hp SED2-BT300-F-7
SED2 208V 50 to 60hp 480V 100 to 125hp SED2-BT300-F-8
Accessories and Service Kits
www.usa.siemens.com/hvac
Variable Frequency Drives
C-39
Description Part No.
SED2
PC Kit. SED2-PC-KIT
Gland Plates. (included with NEMA Type 1)
• Frame A SED2-GL-A
• Frame B SED2-GL-B
• Frame C SED2-GL-C
Protection Shield. (included with NEMA Type 1)
• Frame A SED2-PS-A
• Frame B SED2-PS-B
• Frame C SED2-PS-C
• Frame D, E SED2-PS-DE
NEMA Type 1 and 3R Enclosed Reactors. Contact Sales Partners
NEMA Type 3R Floor Mounting Kit.
• Frames A, B, C 994-809
BOP/AOP Door Mounting Kits.
• BOP/AOP Single Inverter SED2-DOOR-KIT1
• AOP Multi-Inverter SED2-DOOR-KIT2
Operator Panel.
• Basic Operator Panel (included with all SED2s) SED2-BOP1
• Advanced Operator Panel (AOP) SED2-AOP1