Brain Atlas
Dan Diner
![Page 2: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/2.jpg)
Introduction
• PET is a nuclear imaging technique• A radiotracer is injected into subject, and the
signal that it sends off is captured and measured to find out how much activity occurs and where
• The information that is collected is used for brain study, and disorder analysis and diagnosis
QuickTime™ and a decompressor
are needed to see this picture.
![Page 3: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/3.jpg)
ROI/VOI Mapping
• ROIs(Regions of Interest) are small regions mapped onto brains
• Most common way of mapping is manual• Manual mapping is very time-consuming and
requires highly-paid personnel (raters)• Raters have inter- and intra- subject variation• As PET scan quality increases, so does the
time it takes for raters to do their job
![Page 4: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/4.jpg)
• PET has very poor spatial resolution
• MRI has very high spatial resolution
• ROIs are therefore mapped onto the MRI of a subject, onto which the PET scan is co-registered
![Page 5: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/5.jpg)
QuickTime™ and a decompressor
are needed to see this picture.
MRI PET Co-Registered
![Page 6: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/6.jpg)
Brain Atlases• An “average brain” (co-registered PET/MRI)• Has all VOIs labeled manually onto it• These automated methods have been developed to label
VOIs (Volumes of Interest)• Never have been as accurate as manual methods• Very precise - have no inter- or intra- subject variation• Take drastically less time to label a brain than manual
methods
![Page 7: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/7.jpg)
Brain Atlases
• Many imaging labs have their own, but we could not use another labs’ because each lab has different MRI acquisition and labeling techniques
• Can be single- or multiple- subject template• Could be made for only one specific region or
many• Probabilistic atlases tell you the probability of
a certain voxel belonging to a certain ROI
![Page 8: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/8.jpg)
Methods and M aterials: Subject and Image Acquisition
• MRIs and PETs from 176 subjects of past studies
• 123 from a 1.5 Tesla MRI
• 53 from a 3.0 Tesla
![Page 9: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/9.jpg)
Image Analysis Setup
• Worked on a PowerMac G5 using Mac OS X 10.5.4 Leopard
Major Software used:• Matlab (R2007a)• FSLVIEW and FLIRT• ART• iView
![Page 10: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/10.jpg)
Image Pre-Processing
• Raw MRI files were
copied to a common
folder QuickTime™ and a decompressor
are needed to see this picture.
![Page 11: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/11.jpg)
• Previously made Gray Matter,
White Matter, and Cerebral Spinal Fluid Masks were multiplied(matrix multiplication) against the raw
files to get rid of all extraneous
material (neck, skull, dura matter)
QuickTime™ and a decompressor
are needed to see this picture.
![Page 12: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/12.jpg)
QuickTime™ and a decompressor
are needed to see this picture.
QuickTime™ and a decompressor
are needed to see this picture.
QuickTime™ and a decompressor
are needed to see this picture.
![Page 13: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/13.jpg)
QuickTime™ and a decompressor
are needed to see this picture.
![Page 14: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/14.jpg)
• Used iView to compare new images against raw ones
• We did this to ensure that all extraneous material was gone and that no brain was accidentally segmented
• I used a scale of 0-3 to rate the new images (0= perfect, 1=some dura, 2=much dura, 3=segmented brain)
• Most images were 0s and 1s.
![Page 15: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/15.jpg)
QuickTime™ and a decompressor
are needed to see this picture.
![Page 16: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/16.jpg)
Normalization Procedure
• MNI template to which were were normalizing was reoriented towards raw MRI native space
• New MRI images also normalized to this template
• We examined the normalized images, and found that some were very well aligned, but others were misplaced or improperly warped
![Page 17: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/17.jpg)
• ART uses a 2-step process to warp MRIs: linear registration, then warp
• Linear registration is rotations• Warping is dilations• Because the rotation was bad, we thought
that the linear registration had gone wrong• We tried linear registration(first 9 Degrees of
Freedom) with FLIRT, and then warping(up to 12 dof) with ART
![Page 18: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/18.jpg)
• The rotations came out looking good, but close inspection revealed that some leftover dura got warped into the new brain
QuickTime™ and a decompressor
are needed to see this picture.
![Page 19: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/19.jpg)
• An MRI with a particularly large amount of dura was manually cleaned, and then had FLIRT and ART run on it
• The resulting image was perfect
![Page 20: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/20.jpg)
Conclusion
• ART is very sensitive to extraneous material
• all dura needs to be properly removed from all images before normalization
• A better automatic method for cleaning up dura needs to be developed
![Page 21: Summer Work](https://reader035.vdocuments.us/reader035/viewer/2022062513/5562b676d8b42a2e6e8b543b/html5/thumbnails/21.jpg)
QuickTime™ and a decompressor
are needed to see this picture.