Download - SUmber Dan Kualitas Air
![Page 1: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/1.jpg)
Water :Resource and Characterisic
![Page 2: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/2.jpg)
Utilitas
Water resources• vary in regional/local patterns of availability• dependent on topographic & meteorological
conditions• dependent on the physical features of the
earth and on the earth’s geological structure
3 types of water resources:
1. Surface water
2. Ground water
3. Sea water
![Page 3: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/3.jpg)
Utilitas
Water quality characteristics
• Physical
• Chemical
• Biological
![Page 4: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/4.jpg)
Utilitas
Physical characteristics
• Temperature
• Turbidity
• Suspended solid
• Taste and odor
![Page 5: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/5.jpg)
Utilitas
Chemical characteristics
• pH
• Alkalinity
• Hardness
• Conductivity
• Dissolved organic, inorganic materials & gas
SCALING
CORROSION
![Page 6: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/6.jpg)
Utilitas
pH
• Indicates the hydrogen ion concentration in water
• pH > 7 scaling
• pH < 7 corrosion
![Page 7: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/7.jpg)
Utilitas
Alkalinity
• A measure of the water’s ability to absorb hydrogen ions without significant pH change
• Water alkalinity is determined by carbonate ions and hydroxyl ions (OH-)
• The carbonate system is comprised of the following chemical species:– Aqueous carbon dioxide CO2 (aq)
– Carbonic acid H2CO3
– Bicarbonate ion HCO3-
– Carbonate ion CO32-
![Page 8: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/8.jpg)
Utilitas
A series of alkalinity reaction
CO2(aq) + H2O H2CO3 H+ + HCO3-
HCO3- H+ + CO3
2-
CO32- + H2O HCO3
- + OH-
If there is a source of solid CaCO3, then the solubility reaction for CaCO3(s) applies in the system:
CaCO3(s) Ca2+ + CO32-
![Page 9: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/9.jpg)
Utilitas
• From the equations, it can be seen that CO2 and three forms of alkalinity are all part of one system that exist in equlibrium
• A change of concentration of one ions will result in a change in pH
![Page 10: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/10.jpg)
Utilitas
CO2 pH 4.5 – 8.5 HCO3
- pH 4.5 – 9.5 CO3
2- pH 8.5 – 14 OH - pH 9.0 -- 14
![Page 11: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/11.jpg)
Utilitas
Alkalinity (mol/L) = [HCO3-] + 2[CO3
2-] + [OH-] – [H+]
where concentrations in the brackets are [mol/L]
If the concentrations are measured in terms of equivalents, or in mg/L as CaCO3:
Alkalinity (meq/L) = (HCO3-) + (CO3
2-) + (OH-) – (H+)
![Page 12: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/12.jpg)
Utilitas
Analysis
• Using sulfuric acid (H2SO4)
• Alkalinity P (end point pH : 8.3)
CO3- HCO3
-
• Alkalinity M (total alkalinity, end point pH : 4.5)
HCO3- H2CO3
If P alk = 0 all of the alkalinity is bicarbonate
![Page 13: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/13.jpg)
Utilitas
![Page 14: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/14.jpg)
Utilitas
Hardness
• The presence of multivalent cations, most notably Ca and Mg ions
• 2 problems:– The reaction between hardness and soap
produces a sticky, gummy deposit (soap curd)– Ca2+ and Mg2+ precipitate while heated
reduces efficiency of HE
![Page 15: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/15.jpg)
Utilitas
HardnessThere are 2 types of hardness based on the anions1. Carbonate hardness (CH) temporary
hardness. It can be removed by simply heating the water.
associated with HCO3- & CO3
2-
Ca2+ + 2HCO3- CaCO3 + CO2 + H2O
bicarbonate Ca bicarbonate
2. Noncarbonate hardness (NCH)
![Page 16: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/16.jpg)
Utilitas
Total hardness (TH) = Ca2+ + Mg2+
NCH = TH – CH
CH = HCO3- + CO32-
![Page 17: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/17.jpg)
Utilitas
Hardness commonly expresses as mg/L
CaCO3
Equivalent weight =
mg/L of X as CaCO3 =
n
weightmolecularoratom
meqmgXofweightequivalent
meqCaCOmgLmgXofionconcentrat
/
/0.50/ 3
![Page 18: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/18.jpg)
Utilitas
Hardness classification
Descriptionhardness
meq/l mg/L as CaCO3
Soft < 1 < 50
Moderately hard 1 – 3 50 – 150
Hard 3 – 6 150 – 300
Very hard > 6 > 300
* Masters, G.M. 1998. Introduction to environmental engineering and science. p281
![Page 19: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/19.jpg)
Utilitas
Conductivity
Electrical conductivity: a measure of the ionic activity of a solution in terms of its capacity to transmit current
Can be used to predict total dissolved solid
Units: micromhos/cm
![Page 20: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/20.jpg)
Utilitas
Relationship between TDS & conductivity varies according to
solution concentration
Conductivity (mhos/cm)
TD
S (
mg
/L)
Dilute solution Concentrated solution
![Page 21: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/21.jpg)
Utilitas
Water Saturation Index
Saturation Index is a means of evaluating water quality data to determine if the water has a tendency to be corrosive or to form a chemicals scale
The evaluation is based on the pH, alkalinity, hardness, total dissolved solid or conductivity
There are many type of saturation index, the most commonly used is :Langelier saturation indexRyznar saturation index
![Page 22: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/22.jpg)
Utilitas
Langelier saturation index
• The saturation index (SI) can be calculated as follows :
• Whereas pHs = theoritical pH or pH at saturation can be determined from graph or by calculation
SI = pH – pHs
![Page 23: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/23.jpg)
Utilitas
![Page 24: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/24.jpg)
Utilitas
![Page 25: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/25.jpg)
Utilitas
SI values and recommended treatment
www.water-research.net/corrosion.htm
SATURATION INDEX DESCRIPTION RECOMMENDATION
-5 Severe corrosion Treatment recommended
-4 Severe corrosion Treatment recommended
-3 Moderate corrosion Treatment recommended
-2 Moderate corrosion Treatment may be needed
-1 Mild corrosion Treatment may be needed
-0.5 None-mild corrosion Probably no treatment
0 Near balanced no treatment
0.5 Some faint coating Probably no treatment
1 Mild scale coating Treatment may be needed
2 Mild to moderate coating Treatment may be needed
3 Moderate scale forming Treatment advisable
4 Severe scale forming Treatment advisable
![Page 26: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/26.jpg)
Utilitas
Ryznar saturation index
• The Ryznar Stability index is an empirical method for predicting scaling tendencies of water based on a study of operating results with water of various saturation indices
• This index is often used in combination with the Langelier index to improve the accuracy in predicting the scaling or corrosion tendencies of a water.
Stability index = 2pHs - pH = pHs - Langelier's Saturation pH
![Page 27: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/27.jpg)
Utilitas
![Page 28: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/28.jpg)
Utilitas
Biological characteristics
• Microbiological contaminants
• Microorganisms:– Non-pathogenic– Pathogenic
• Coliform bacteria (typically e.coli) are used as indicator organisms
• The presence of coliform suggests that the water is contaminated
![Page 29: SUmber Dan Kualitas Air](https://reader030.vdocuments.us/reader030/viewer/2022020122/55242de74a795968498b4611/html5/thumbnails/29.jpg)
Utilitas
Summary
Ground water Characteristic Surface water
Low turbidity High
High mineral Vary
Low dissolved O2 Vary
Low microorganism High
Stable temp & chem Unstable
Low pollutant High