Status of the Photocathode R&Dfor ATF RFgun
N.Terunuma (KEK)
![Page 2: Status of the Photocathode R&D for ATF RFgun N.Terunuma (KEK)](https://reader036.vdocuments.us/reader036/viewer/2022062315/5697bff71a28abf838cbe967/html5/thumbnails/2.jpg)
Why we use Cs2Te photocathode?
Pure metal cathode.Q.E. 10-5 ~ 10-4
Cs2Te Q.E. ~ 10-1 , a few %
OthersNeed more study.
We prepared the Cs2Te formation system and the Cathode loadlock system for ATF.
For ATF, Shorter preparation time for the beam operation.--> Preparation system connected to the RFGUN.
![Page 3: Status of the Photocathode R&D for ATF RFgun N.Terunuma (KEK)](https://reader036.vdocuments.us/reader036/viewer/2022062315/5697bff71a28abf838cbe967/html5/thumbnails/3.jpg)
RFGUNCavity
Cathode loading mover
RFGUN
Laser
Cathode Load-lock System
Cleaning&Pickup Storage
Cathodeformation
Xe light
![Page 4: Status of the Photocathode R&D for ATF RFgun N.Terunuma (KEK)](https://reader036.vdocuments.us/reader036/viewer/2022062315/5697bff71a28abf838cbe967/html5/thumbnails/4.jpg)
Quantum EfficiencyQ.E.= Number of electrons / Number of photons
Offline measurementXe lamp with monocrometer~266nm.Measure the current on cathode.
Online measurementRFGUN operation, Laser~266nm.Extracted beam intensity detected by faraday cup.
![Page 5: Status of the Photocathode R&D for ATF RFgun N.Terunuma (KEK)](https://reader036.vdocuments.us/reader036/viewer/2022062315/5697bff71a28abf838cbe967/html5/thumbnails/5.jpg)
Cathode and Cs-Te sources
Te
Cs
Evaporation SystemCathode Plug (Cu)
15mm
![Page 6: Status of the Photocathode R&D for ATF RFgun N.Terunuma (KEK)](https://reader036.vdocuments.us/reader036/viewer/2022062315/5697bff71a28abf838cbe967/html5/thumbnails/6.jpg)
Half cell endplate with Cu plug
![Page 7: Status of the Photocathode R&D for ATF RFgun N.Terunuma (KEK)](https://reader036.vdocuments.us/reader036/viewer/2022062315/5697bff71a28abf838cbe967/html5/thumbnails/7.jpg)
Argon ion bombardment
WhenNew cathode is installed.Clean the used cathode.Sputter depth ~ 50nm .
Step 1: Cleaning
Ion Source
Cleaningchamber
Formation: Step 1, Cleaning
![Page 8: Status of the Photocathode R&D for ATF RFgun N.Terunuma (KEK)](https://reader036.vdocuments.us/reader036/viewer/2022062315/5697bff71a28abf838cbe967/html5/thumbnails/8.jpg)
Te is heated by a Tungsten filament.We can control the Te thickness.
Step 2: Evaporation of Te
Formation: Step 2, Te evaporation
![Page 9: Status of the Photocathode R&D for ATF RFgun N.Terunuma (KEK)](https://reader036.vdocuments.us/reader036/viewer/2022062315/5697bff71a28abf838cbe967/html5/thumbnails/9.jpg)
Cs is evaporated on the Te film and its thickness is controlled by monitoring the Q.E. with Xe system.
Step 3: Evaporation of Cs
Formation: Step 3, Cs evaporation
Cathode holder with Mask 8mm
![Page 10: Status of the Photocathode R&D for ATF RFgun N.Terunuma (KEK)](https://reader036.vdocuments.us/reader036/viewer/2022062315/5697bff71a28abf838cbe967/html5/thumbnails/10.jpg)
R&DFor the ATF operation…
Prepare the new cathode on Monday.Beam Test: a week or more.Check Q.E. by calibrated lights (Xe,266nm) every a few days.
For the basic study… in shutdown weeks.
This year, we had two months beam operation.Two Cu plugs Two Mo plugs
![Page 11: Status of the Photocathode R&D for ATF RFgun N.Terunuma (KEK)](https://reader036.vdocuments.us/reader036/viewer/2022062315/5697bff71a28abf838cbe967/html5/thumbnails/11.jpg)
QE of Cu#1 Cathode
ATF
1.3x10-6 Pa at RFGUN
Q.E.0.4%
Yellow area: RF on
![Page 12: Status of the Photocathode R&D for ATF RFgun N.Terunuma (KEK)](https://reader036.vdocuments.us/reader036/viewer/2022062315/5697bff71a28abf838cbe967/html5/thumbnails/12.jpg)
Cu cathode after the Beam TestTwo cathode plugs were used for a month operation.
Cu#1 cathode (left)Used for the cavity aging.Many RF breakdowns.
Cu#2 cathode (right)Used stable laser operation.
![Page 13: Status of the Photocathode R&D for ATF RFgun N.Terunuma (KEK)](https://reader036.vdocuments.us/reader036/viewer/2022062315/5697bff71a28abf838cbe967/html5/thumbnails/13.jpg)
Mo Cathode
Two plugs ware used for a month operation.Their surface were polished as a mirror.
Small damage was found after the beam operation.
![Page 14: Status of the Photocathode R&D for ATF RFgun N.Terunuma (KEK)](https://reader036.vdocuments.us/reader036/viewer/2022062315/5697bff71a28abf838cbe967/html5/thumbnails/14.jpg)
Q.E. of Cs2Te on Mo plugs
• Q.E. before RF power is supplied reaches > 15%.
• Q.E. dropped quickly when RF power was supplied.
• It shows stable Q.E. after RF power supplied.
• Cs2Te on Molybdenum plugs shows higher Q.E. ~3% than that on Copper plugs ~0.4%.
![Page 15: Status of the Photocathode R&D for ATF RFgun N.Terunuma (KEK)](https://reader036.vdocuments.us/reader036/viewer/2022062315/5697bff71a28abf838cbe967/html5/thumbnails/15.jpg)
Dark vs.
Dark Current
Power (MW)
![Page 16: Status of the Photocathode R&D for ATF RFgun N.Terunuma (KEK)](https://reader036.vdocuments.us/reader036/viewer/2022062315/5697bff71a28abf838cbe967/html5/thumbnails/16.jpg)
SummaryWe had two months beam operation.
Cs2Te on Cu plugsQ.E. ~0.4%.Damages on the Cu surface.
Cs2Te on Mo plugsQ.E. ~3%. Stable.Small damages compared to Cu case were observed.
Next Establish the formation method and its reproducibility.Check Q.E. under longer beam operations.