Download - Solid State Disk Product Introduction Hybrid Server Efsun (212) 216-0877 [email protected]
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 2 Samsung Corporation
CONTENTS
Part 2. What is Jet-Speed?
Part 3. What is Hybrid Server?
Part 1. Introduction of Taejin
Part 4. Data Reliability
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 3 Samsung Corporation
EUROPE
CHINAN. AMERICA
JAPANChina (Hangzhou)
Beijing
India
Samsungcooperation
Main productMain product
Home pageHome page
Wireless PDA Terminal
www.taejin.co.kr Hybrid Server, Storage, Jet-Speed
1. Overview
Part 1. Introduction of Taejin
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 4 Samsung Corporation
1992 2001 2002 2004 2005 2006(E)
System Integration Business
2. Company History
Foundation period Enhancement period Growth period
• Jan ‘97 Founded as TAEJIN
INFOTECH
•`Nov ‘01 Awarded the '2001 Venture Firm'
• Jan `02 Founded the company's annex research institute
• Sep `02 Introduced the Home view into the market
• Apr `04 Established the China corporation at Hang Zhou
• Dec `04 Introduced the Jet-Speed™ into the market
• Dec `04 Certified TL 9000
•Mar `05 Participated in CeBIT 2005 in Hanover/Germany
•Jun `05 introduced wireless mobile payment terminal into the market
•Aug `05 Participate in 6th small and medium enterprise innovative technologies fair
•Sep `05 Jet-Speed certified at USA, Europe and Japan
•Oct `05 Award silver prize at Korean Design Fair
∙Jul `06 Introduced Hybrid Server to the market
Part 1. Introduction of Taejin
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 5 Samsung Corporation
1. What is SSD ?
Speed of CPU & Memory has been improved 570 times during last 20 years
Speed of HDD has been improved only 20 times due to mechanical limitation.
performance
Memory 대역폭
CPU 대역폭
Memory
CPU
Bottleneck state HDD
Memory
Speed
SSD
SSD (Solid State Disk)
CPU
Memory
HDD
Speed
※ SSD is storage device based on High-Speed Semiconductor
to get rid of Bottle neck caused by HDD
performance
Part 2. What is Jet-Speed?
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 6 Samsung Corporation
2GB ECC Registered DDR SDRAM
2GB ECC Registered DDR SDRAM
2. What is Jet-Speed
1 DISK :16GB base (PCI Interface) Maximum performance : 65,000 IOPS Insert to PCI-x Slot (Over 64bit/100MHz) Fastest Solid State Disk in the world
Jet-Speed : 1) Storage device based on semi-conduct technology 2) Jet Speed is over 200 times faster than current HDD
Part 2. What is Jet-Speed?
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 7 Samsung Corporation
3. Specification of Jet-Speed
Jet-Speed PRO [Spec) Fastest SSD in the world
PCI type Solid State disk (CE, FCC, VCCI, TUV, MCI)
PCI Standard 16GB 188 Pin, PCI Standard
5VDC(-/+ 5%) 4.5 watts
9 s 528MB/sec 400M/sec 65,000 IOPS
5 ~ 75℃ 5% ~ 90% 800G, 0.4ms 5G rms Backup / Monitoring S/W
FCC, CE, TUV, VCCI, MIC
Physical SpecForm Factor
CapacityConnector
Power RequirementVoltage
Power ConsumptionsPerformance Spec
Access TimeRandom Burst R/W Rate
Random Sustained R/W RateIOPS (512B Size)
Environmental SpecTemperature
HumidityShock
VibrationManagement Spec
Certification
Description
2GB ECC Registered DDR SDRAM
Part 2. What is Jet-Speed?
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 8 Samsung Corporation
4. Performance of Jet Speed
Source: Taejin Performance Lab Tests
Test Server Spec. Server : HP DL585 hybrid SVR(4U). CPU : AMD 875 2.2GHz * 2. Memory : 4G ECC DDR. PCI : 64Bit/100MHz. Jet-Speed : 16GB (1 DISK SSD). HDD : U320 15K 72.8GB * 1
※ IOPS Performance, Jet-Speed PRO vs. HDD
0
10000
20000
30000
40000
50000
60000
70000
512B 1K 2K 4K 8K 16K
HDDJet-Speed
65,000 times of random write 512 character in 1 second
16GB Memory DISK
Part 2. What is Jet-Speed ?
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 9 Samsung Corporation
5. Jet Speed Applied field –Performance
Clients
Web Server AP Server
Jet-Speed® PCI
SSD => Main Memory => CPU => SSD Storage
DBMS Server
Jet-Speed Expert
RAID SYSTEM
BACKUP
Part 2. What is Jet-Speed ?
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 10 Samsung Corporation
6. Jet Speed Applicable field
OLTP (Online Transaction Processing) ERP (Enterprise Resource Planning) CRM (Customer Relationship Management)
Business Processing
Download and printer server
Networking
Caching server
System management server
IT infrastructure
3D, 2D CAD/CAM Editing program such as Quark Xpress
Computer graphic and editing
Data collect and analysis Embedded (Compile) Research Lab
ETC
Data warehousing and Data mart Data analysis and data mining
Decision making system
Web service (B2B, B2C, Internet banking, e-Trading)
Internet Billing, m-Commerce
Streaming service
Game service
Real time application
Web Infrastructure
SSO and billing system LBS, GPS WAP Gateway
Mobile communication
Part 2. What is Jet-Speed ?
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 11 Samsung Corporation
7. Customer
Domestic
Chungbuk National University
Daegu Haany University
Seoul Metropolitan Facilities Management Corporation
ETRIKorea Press Foundation
Hamyang County
Postech
Samsung corporation
Wongsan Library
Device Information & Communication Co., Ltd.
MOOHA digital Co., Ltd.
DatawareUNITEL Networks
Hankook Institute Of Life Science
People & Research
Part 2. What is Jet-Speed ?
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 12 Samsung Corporation
Company name Applied fields Improvement
Overseas
MTI (USA) Database searching Reduction of searching time
ARIX (Japan) Database searching Reduction of searching time
Guangzhou TSE (China) Mail server Reduction of mail server respond time
Guangxi her Balist medicine Hospital (China)
Hospital Medical database Faster respond time with more concurrent users.
Evertec Technology
(Slovak Republic)
IPTV Editing performance improved and able to afford more concurrent users.
HP Networking (Greece) IPTV Editing performance improved and able to afford more concurrent users.
Wascow (Poland) IPTV Editing performance improved and able to afford more concurrent users.
Overseas
7. Customer
Part 2. What is Jet-Speed ?
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 13 Samsung Corporation
9. Jet Speed Line-up
Internet Banking and e-Trading Telecommunication (SMS, WAP, authentication, Billing…) M-commerce Batch work Internet Billing ERP/CRM/SCM Streaming Data (A/V) Cache data for many random I/O
IOP
S
CAPACITYHigh-End Jet-Speed®
8G~16G
64GB~128GB
128GB~384GB
256G~1T
1TB ~2TB
8G ~16GB
Hybrid server
16GB~ 48GB
HP DL585 Hybrid SVR
IBM x366 Hybrid SVR
64GB~128GB
Web cache server Email Server Messaging LDAP server OLTP server Firewall server
Part 2. What is Jet-Speed ?
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 14 Samsung Corporation
1. Concept of Hybrid Server
Hybrid Server
Embed Jet Speed to current server.Performance will be upgraded up to 300~1000%
Jet-Speed PRO(16GB) Hybrid Server(64GB~128GB)
100,000 ~ 200,000 IOPS
Taejin
HP
IBM
Taejin
Part 3. What is Hybrid Server?
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 15 Samsung Corporation
Jet-Speed SVR (Spec) : TJ-P20110
1U Intel Xeon Dual Core Support / Up to 16G Memory SCSI U320 78GB 16GB Gigabit Port. Ethernet Controller (PCI-Express) PCI-X 64bit/66MHz(1) 88 ~ 240 VAC 500watts Active PFC (Redundant Hot-Swap) Support 6 Hour SCSI U320
9 s 528MB/sec 400GB/sec 53,000 IOPS (Up to 80,000 IOPS)
5 ~ 45℃ 5% ~ 75% 1G, 2~50ms 0.25G(5~500Hz) Backup S/W
Physical SpecForm Factor
CPU / MemoryInternal Disk
Capacity (SSD)NIC
Expansion SlotPower Requirement
VoltagePower Consumptions
Backup BatteryBackup DISK
Performance SpecAccess Time
Random Burst R/W RateRandom Sustained R/W Rate
IOPSEnvironmental Spec
TemperatureHumidityShock
VibrationManagement Spec
Description
2. Hybrid Server for Web Portal
Part 3. What is Hybrid Server?
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 16 Samsung Corporation
Jet-Speed SVR (Spec) : TJ-K2611XD(2U)
2U Intel Xeon Dual Core Support / Up to 16G Memory SCSI U320 (RAID 0, 1, 5, 10) 16GB ~ 48GB Gigabit Port. Ethernet Controller(PCI-Express) PCI-X 64bit/100MHz(2), 133MHz(1), Express x8(2), x4(1) 88 ~ 240 VAC 500watts Active PFC (Redundant Hot-Swap) Support 6 Hour SCSI U320
9 s 800MB/sec 650GB/sec 100,000 IOPS
5 ~ 45℃ 5% ~ 75% 1G, 2~50ms 0.25G(5~500Hz) Backup S/W
Physical SpecForm Factor
CPU / MemoryInternal Disk
Capacity (SSD)NIC
Expansion SlotPower Requirement
VoltagePower Consumptions
Backup BatteryBackup DISK
Performance SpecAccess Time
Random Burst R/W RateRandom Sustained R/W Rate
IOPS (512B)Environmental Spec
TemperatureHumidityShock
VibrationManagement Spec
Description
Hybrid Server for Web Transaction
Part 3. What is Hybrid Server?
3.
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 17 Samsung Corporation
BMT Result (TJ-K2611XD Hybrid SVR)
Size (Byte)
Jet-Speed(80GB) U320 10K DISK(72.8GB) Multiplier (Jet Speed/HDD)
IOPSBandwidth (MB/ sec)
Access Time (ms)
CPU (%)
IOPSBandwidth (MB/sec)
Access Time(ms)
CPU(%)
IOPS BandwidthAccessTime
CPU
512B 70922 34.63 0.28 90.84 287 0.14 41.70 0.6 247 247 149 151
2KB 64120 125 0.30 84.74 275 0.54 43.24 0.52 233 231 144 163
4KB 59034 230 0.33 76.21 273 1.12 44.21 0.51 216 205 134 149
8KB 43180 337 0.46 56.56 268 2.1 44.49 0.41 161 160 97 138
16KB 28063 438 0.71 36.06 266 4.16 44.92 0.41 106 105 63 88
32KB 16148 504 1.23 22 259 9.08 46.30 0.23 62 56 38 96
64KB 8794 549 2.27 15.52 214 13.42 55.72 0.37 41 41 25 42
128KB 4580 572 4.36 11.16 204 21.88 67.90 0.37 22 26 16 30
256KB 2316 579 8.62 9.67 136 34.16 84.37 0.36 17 17 10 27
512KB 1166 583 3.42 8.61 99 49.64 120.81 0.31 12 12 35 28
TJ-K2611XD Spec(2way)1. CPU : Intel Xeon 3.4GHz 2CPU2. Memory : PC3200 DDR SDARM 4G3. HDD : U320 10K 72.8GB 14. jet-Speed : 16GB * 2 = 32GB(RAID 0)5. PCI : PCI-x 64bit/133MHz 1, 100MHz 26. OS : 2003 Standard R2 (Support Linux 64bit)Testing Tool1. S/W : IO meter 7.02. Test - worker :4 - Data size :30GB - Outstanding Ios : 4 - Runtime : 5 Minutes (300 seconds) - Random Write 100%
Part 3. What is Hybrid Server?
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 18 Samsung Corporation
IBM x366 Hybrid Server Hybrid Server(3D server, VOD server, Mapping server)
3U Intel Xeon Dual Core 3.16GHz / Up to 64G Memory IBM SAS 78GB *2 64GB ~ 96GB Gigabit Port. Ethernet Controller PCI-X 64bit/266MHz(6) 88 ~ 240 VAC 1300watts (2N+1) Support 6 Hour SCSI U320
9 s 2000MB/sec 1450MB/sec <10,000 IOPS
5 ~ 45℃ 5% ~ 75% 1G, 2~50ms 0.25G(5~500Hz) Backup S/W
Physical SpecForm Factor
CPU / MemoryInternal Disk
Capacity (SSD)NIC
Expansion SlotPower Requirement
VoltagePower Consumptions
Backup BatteryBackup DISK
Performance SpecAccess Time
Random Burst R/W RateRandom Sustained R/W Rate
IOPS (128KB)Environmental Spec
TemperatureHumidityShock
VibrationManagement Spec
Description
IBM x366 Hybrid SVR
4.
Part 3. What is Hybrid Server?
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 19 Samsung Corporation
BMT Result (IBM x366 Hybrid SVR)
Size (Byte)
Jet-Speed(80GB) U320 10K DISK(72.8GB) Multiplier (Jet Speed/HDD)
IOPS Bandwidth (MB/ sec)
Access Time (ms)
CPU (%) IOPS Bandwidth
(MB/sec)Access Time (ms)
CPU (%) IOPS Bandwidth Access
Time CPU
16KB 48439 756 0.26 42.01 509 7.96 15.67 0.53 95 95 60 79
32KB 32624 1019 0.39 32.8 426 13.33 18.70 0.37 77 76 48 89
64KB 19057 1191 0.68 23.8 324 20.31 24.52 0.37 59 59 36 64
128KB 10384 1298 1.25 21.38 204 25.57 38.91 0.36 51 51 31 59
256KB 5606 1401 2.31 20.18 122 30.58 65.04 0.34 46 46 28 59
512KB 2885 1442 4.51 19.47 71 35.65 110.40 0.56 41 40 24 35
1MB 1449 1449 8.96 18.43 42 42.16 187.72 0.36 35 34 21 51
2MB 723 1446 17.95 21.17 25 50.93 308.90 0.71 29 28 17 30
4MB 359 1439 36.05 19.06 12 51.91 607.21 0.77 30 28 17 25
8MB 178 1424 72.82 19 6 52.48 2010.89 0.54 30 27 28 35
IBM eSERVER x366 Spec(4way)11. CPU : Intel Xeon 3.0GHz 4CPU2. Memory : PC3200 DDR SDARM 4G3. HDD : SAS 10K 68.2GB 2(Raid )4. jet-Speed : 16GB * 6 = 96GB(Raid 0)5. PCI : Active PCI-x 64bit/266MHz 66. OS : 2003 standard R2(Support Linux 64bit)Testing Tool7. Test (IO meter 7.0) - worker :4 - Data size :100GB - Outstanding Ios : 4 - Runtime : 10,000 Minutes - Random Write 100%
Part 3. What is Hybrid Server?
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 20 Samsung Corporation
5. CertificationEurope (CE) USA (FCC)
Part 3. What is Hybrid Server?
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 21 Samsung Corporation
5. Certification
Japan (VCCI) Korea (MIC)
Part 3. What is Hybrid Server?
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 22 Samsung Corporation
6. Summary
Same operation as HDD To get best performance - CPU Upper than Intel Xeon Dual core 3.0GHz Upper than AMD Opteron Dual core 875 2.2GHz
- Bandwidth Over 1GByte/sec
- For Raid Configuration equipped at same MHz unit slot Equip at 64bit/100MHz Slots or equip at 64bit/133MHz Slots
Support real time copy S/W (HA Based Replicator Option) Lithium-polymer Battery can hold for 6 hours without power (SCSI DISK Type)
Jet-Speed Error Correction: Each module in multi bit, automatically corrects for 3 time (Maximum :12KB Lose)
- After over 5 times of error occurs, sends replacing message
- Probability of bit unit error occurs more than 5 times in 1 DISK is 0.0000000000000001% On the progress of supply OEM to IBM, Korea
Part 3. What is Hybrid Server?
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 23 Samsung Corporation
1.Lithum polymer Battery
Server
Type
DISK
Type
Battery pack
Type
ReferenceBattery Type
- Support 8 DISK(128GB)
- Supply power for 8~10
hours when there is a
stoppage of power supply
- Support 2 DISK(32GB) (Recommend)- Support 4 DISK(64GB) (Maximum)- Supply power for 2~3 HRS when there is a stoppage of power supply
- Support 1 DISK(16GB)
- Supply power for 4~6
hours when there is a
stoppage of power supply
Part 4. Data Reliability
Support RAID and Guarantee the data reliability with Lithium polymer battery & HA based Replicator
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 24 Samsung Corporation
2. TJ-syncrobo Replicator
▪ Real-time data copy by Byte unit - When event occurs, replicator indicates by kernel level, when who does what at where. And replicate the dat
a
by Byte unit in real time
※ The method which send notify by application (not kernel) level is not perfect enough.
▪ The reason why Real-time data copy by Byte unit is required - To modify least amount of database. Modify only a few bytes to 64 bytes as change of the current data
which is just updated or changed. This will minimize the load to network or system
DB Target fileDB Source fileVolume
Table
Part 4. Data Reliability
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 25 Samsung Corporation
2. TJ-syncrobo Repilcator
Service Start
Current back-up software(Several ten minutes ~ several hours)
SyncRobo Server(Several ten seconds~ several minutes)
System trouble occurs
DB Restore Process
Service startSystem trouble
occursRoute modify
※ SyncRobo Byte Replicator doesn’t need restoration process. By route establishing, replicated data can be used immediately.
▪ OFM (Open File Manager)
- When some files are locked and not even a read is allowed on those files. However OFM makes it possible to read. OFM is the highest technology which is the core of the real-time DB back-up
Part 4. Data Reliability
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 26 Samsung Corporation
2. TJ-syncrobo Repilcator
1 Node : Real time Asynchronous Replication
Write on Target
Database ACTIVE
File Modification
Source modifyCompletion
Write on Source
Modification Filtering
Target modifyCompletion
Target Volume (HDD)
Guarantee the data reliability of non-stop system operating data of database of target File → TJ-SyncRobo Server Method
Mo
dificatio
n seq
uen
ce
Active Volume (Jet-Speed)
Database Fail
File Modification
Source modifyCompletion
Write on Source
Modification Filtering
Active Service
Restore?(Yes/No)
Yes
NO
Part 4. Data Reliability
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 27 Samsung Corporation
3. Error occurring probability of memory disk
1. Error correcting in firmware2. After 1 million times of data write at 1 Sector, Unable
to guarantee the data in that sector.3. Prolong the PBL changing period by PBA, LBL using
equality-wearing firmware (Because of this, writing IOPS is HDD level) When error occurs change disk unit
Bit
Micro
1. Error correcting in firmware2. Error occurring Probability per 1module : SDRAM (none ECC) 0.0001% When error occurs change 8GB unit
Solid
Data
1. 5 times of error correcting in firmware( followed by manual)
2. Error occurring Probability per 1module : ECC 0.00000001% When error occurs change 16GB unit
TMS
1. 3 times of multi bit error correction in 2GB Module unit2. 3 times of module error correction in firmware 3. 1 DISK(3 times * 8 Module * 3) = 72 times4. Error occurring Probability per 1module: ECC Registered 0.0000000000000001% When error occurs change 2GB unit
Taejin
(Jet-Speed)
Error occurring Probability DISKMinimum UnitVendor
PCI DISK
16GByteASIC CHIP Module
8GbyteASIC CHIP Module
SCSI DISK
2GByte
Part 4. Data Reliability
Copyright 2006 TAEJIN INFOTECH Co., LTD. All rights reservedⓒ 28 Samsung Corporation
Thank You!!!