Skyline Flow Controls – Venturi Meter (SFC-FV) The SFC Venturi Tube is a differential pressure flow element that accurately measures the flows of liquids or gases. SFC utilizes fabricated or cast iron venture tube which incorporates an efficient hydraulic shape with static pressure taps at the throat and inlet sections.
APPLICATIONS: The SFC-FV series venturi meter is often used in petrochemical industries, power plant, municipal water supply and wastewater systems due to its longevity and minimal maintenance. The meters are ideal for metering steam, water, sludge, slurries, viscous fluids, and even fluids contains abrasive solids as it can be coated with tungsten carbide.
ADVANTAGES: The SFC-FV series of venturi meters provide accurate flow measurement within ± 0.50% without flow calibration, even for pipes which have Reynolds numbers greater than 75000. When flow calibrated, the accuracy can be within ± 0.25% for accurate flow measurement, with stability linearity within ± 0.2%, on customer requirement.
TECHNICAL SPECIFICATIONS: Flow Reynolds numbers: ≥75000 Flow Rate Turn-down Ratio: 100:1 or higher
Head Loss The permanent pressure loss of the SFC venturi meter is shown in the figure beside. The head loss is only 10% to 30% of the measuring differential pressure, which is lesser than head loss produced by orifice flow meters or nozzle flow meters. For this reason, it is widely used in chemical plants, refineries, and nuclear power plants. Standard built accurate: ± 0.50% Flow Calibration Accurate: ± 0.25% or better
Skyline Flow Controls – Venturi Meter (SFC-FV)
SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond, BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
REQUIREMENT FOR STRAIGHT PIPE-RUN
Like most flow meters, straight or unrestricted pipe-run upstream and downstream of the flow element is preferred, and will produce better results and accuracy. By providing adequate straight line piping upstream and downstream of the meter, it can significantly increase accuracy despite the presence of disturbers. General guidance is offered in the table below with all dimensions provided being considered from the apex of the wedge element.
RECOMMENDED UPSTREAM AND DOWNSTREAM STRAIGHT-LINE TABLE Upstream Disturber Preferred Diameters Minimum Diameter Partially Opened Gate Valve 10 5 10 3 Concentric Increaser 10 5 5 3 Concentric Reducer 10 5 5 3 1 Elbow 10 5 5 3 2 Elbow Close Coupled in Plane 10 5 5 3 2 Elbow Close Coupled out of Plane
10 5 10 3
SFCSKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
1
SKYLINE FLOW CONTROLS,INC. SFC-Manufacture Shop115-13431 Maycrest Way,Richmond,BC,Ca.Phone:+1-604-285-6890,Fax:+1-604-285-6891Email:[email protected]
Alderbridge Way,Richmond,BC,Canada,CaPhone:(604)-276-1482,Fax:(604)-276-1482-1
www.skylineflowcontrols.com
SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond, BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
Beta Ratio SFC venturi meters are also available with a wide range of diameter ratios (d/D). This provides users with accurate flow measurement over a broad range of flow rates for a given line size.
Temperature Range SFC can handle process temperatures between -180°C to +800 °C.
Pressure Range/End Connections Flanged end connections are made as per ANSI B16.1 from 150 LB to 2500 LB. A variety of other end connections are also available including: mechanical joint flanges or plain-end designs.
Piping Requirements Designed for full-pipe flow, SFC-FV may be mounted either horizontally or vertically. For recommended upstream pipe run, refer to SFC Engineering Instruction and Technical Manual for the Venturi Meters
Energy Considerations The graph shown beside compares the head loss of the SFC design with that of other primary flow elements. The pressure recovery of the SFC venturi tube results in reduced pumping costs. The SFC venturi has a shorter laying length and exhibits better recovery than typical and other type of flow meters.
Headloss Comparison
SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond, BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
Design Concepts The SFC venturi meter is designed to provide a high degree of accuracy and repeatability with unquestionable and predictable performance. Key benefits to this design are as followed: Accuracy: Static inlet and throat pressure sensors provide a highly accurate, stable, and predictable flow measurement signal for flows with Reynolds numbers as low as 75000. Reliability: The SFC venturi meter is free of protrusions and sharp-edged, debris collecting annuli. Static pressure taps reduce flow noise. The internal contour is designed to minimize the buildup of solids and deter erosion, corrosion, and scaling. Energy Savings: SFC venturi meter operate with minimal head loss . This results in less energy consumption, lower operational costs, and a lower cost of ownership. The device performance and metering similitude shall be substantiated through independent testing. Performance data include coefficient value, installation effects, and hydraulic shape head loss.
SFC-FI Venturi Meter
The sizing table on the next page can be used as a guide to aid the user in choosing the proper SFC venturi meter for a given application. Depending on the details of that application, a more appropriate selection, or a more accurate estimation of the performance, may be available. SFC engineering encourages users to contact their local representatives, or call us directly, for definitive sizing information.
SFC SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
2
SKYLINE FLOW CONTROLS,INC. SFC-Manufacture Shop115-13431 Maycrest Way,Richmond,BC,Ca.Phone:+1-604-285-6890,Fax:+1-604-285-6891Email:[email protected]
Alderbridge Way,Richmond,BC,Canada,CaPhone:(604)-276-1482,Fax:(604)-276-1482-1
www.skylineflowcontrols.com
SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond, BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
Beta Ratio SFC venturi meters are also available with a wide range of diameter ratios (d/D). This provides users with accurate flow measurement over a broad range of flow rates for a given line size.
Temperature Range SFC can handle process temperatures between -180°C to +800 °C.
Pressure Range/End Connections Flanged end connections are made as per ANSI B16.1 from 150 LB to 2500 LB. A variety of other end connections are also available including: mechanical joint flanges or plain-end designs.
Piping Requirements Designed for full-pipe flow, SFC-FV may be mounted either horizontally or vertically. For recommended upstream pipe run, refer to SFC Engineering Instruction and Technical Manual for the Venturi Meters
Energy Considerations The graph shown beside compares the head loss of the SFC design with that of other primary flow elements. The pressure recovery of the SFC venturi tube results in reduced pumping costs. The SFC venturi has a shorter laying length and exhibits better recovery than typical and other type of flow meters.
Headloss Comparison
SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond, BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
Design Concepts The SFC venturi meter is designed to provide a high degree of accuracy and repeatability with unquestionable and predictable performance. Key benefits to this design are as followed: Accuracy: Static inlet and throat pressure sensors provide a highly accurate, stable, and predictable flow measurement signal for flows with Reynolds numbers as low as 75000. Reliability: The SFC venturi meter is free of protrusions and sharp-edged, debris collecting annuli. Static pressure taps reduce flow noise. The internal contour is designed to minimize the buildup of solids and deter erosion, corrosion, and scaling. Energy Savings: SFC venturi meter operate with minimal head loss . This results in less energy consumption, lower operational costs, and a lower cost of ownership. The device performance and metering similitude shall be substantiated through independent testing. Performance data include coefficient value, installation effects, and hydraulic shape head loss.
SFC-FI Venturi Meter
The sizing table on the next page can be used as a guide to aid the user in choosing the proper SFC venturi meter for a given application. Depending on the details of that application, a more appropriate selection, or a more accurate estimation of the performance, may be available. SFC engineering encourages users to contact their local representatives, or call us directly, for definitive sizing information.
SFCSKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
3
SKYLINE FLOW CONTROLS,INC. SFC-Manufacture Shop115-13431 Maycrest Way,Richmond,BC,Ca.Phone:+1-604-285-6890,Fax:+1-604-285-6891Email:[email protected]
Alderbridge Way,Richmond,BC,Canada,CaPhone:(604)-276-1482,Fax:(604)-276-1482-1
www.skylineflowcontrols.com
SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond , BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
Tepic data from Flow Verification
SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond, BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
DESIGN AND MANUFACTURING STANDARDS: • All materials are mill certified and of top quality. • All meters are compliant to applicable codes and standards such as: section 8 of the Boiler
and Pressure Vessel Code, ASME B31.1, 31.3. ASME fluid meters, MFC-3M-1985, ISO 5167, and BS-7045.
Type Size Pressure Rating Temperature Material End Connection SFC-FI Insertion Venturi Meter
2” to 120" 150LB to 2500LB
SFC-FV & ASME Venturi Meter
2” to 120”
ANSI 150LB to 600LB
-180℃ to + 650℃
CS, F22, F91, SS321
Threads, BW or Flanges
High Pressure Venturi Meter 2” to 60” ANSI 900LB to
4500LB -180℃ to + 650℃
CS, F22, F91, SS321 BW or Flanges
SFC-FV & ASME Venturi Meter
High Pressure Venturi Meter
SFC SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
4
SKYLINE FLOW CONTROLS,INC. SFC-Manufacture Shop115-13431 Maycrest Way,Richmond,BC,Ca.Phone:+1-604-285-6890,Fax:+1-604-285-6891Email:[email protected]
Alderbridge Way,Richmond,BC,Canada,CaPhone:(604)-276-1482,Fax:(604)-276-1482-1
www.skylineflowcontrols.com
SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond , BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
Tepic data from Flow Verification
SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond, BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
DESIGN AND MANUFACTURING STANDARDS: • All materials are mill certified and of top quality. • All meters are compliant to applicable codes and standards such as: section 8 of the Boiler
and Pressure Vessel Code, ASME B31.1, 31.3. ASME fluid meters, MFC-3M-1985, ISO 5167, and BS-7045.
Type Size Pressure Rating Temperature Material End Connection SFC-FI Insertion Venturi Meter
2” to 120" 150LB to 2500LB
SFC-FV & ASME Venturi Meter
2” to 120”
ANSI 150LB to 600LB
-180℃ to + 650℃
CS, F22, F91, SS321
Threads, BW or Flanges
High Pressure Venturi Meter 2” to 60” ANSI 900LB to
4500LB -180℃ to + 650℃
CS, F22, F91, SS321 BW or Flanges
SFC-FV & ASME Venturi Meter
High Pressure Venturi Meter
SFCSKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
5
SKYLINE FLOW CONTROLS,INC. SFC-Manufacture Shop115-13431 Maycrest Way,Richmond,BC,Ca.Phone:+1-604-285-6890,Fax:+1-604-285-6891Email:[email protected]
Alderbridge Way,Richmond,BC,Canada,CaPhone:(604)-276-1482,Fax:(604)-276-1482-1
www.skylineflowcontrols.com
SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond, BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
SFC-VT-FI , Series Insertion Venturi For applications where limited installation space is a concern for typical venturi meter, the SFC-VT-FI series venturi meter is the most optimal choice due to its unique design. In addition, it cost less than the ordinary venturi. The SFC-VT-FI, Insert Type Venturi primary flow element is a full performance, high accuracy and reliability differential producing flow measurement device that is thoroughly substantiated for 2 sigma performance as indicated below. This equip-ment differs from the SFC-VT pressure vessel meter design in that the hydraulic shape is ruggedly constructed on a properly sized center flange that fits within the bolt circle of the mating process piping. Thus the insert (center flange), is captured between the mating pipe flanges and does not need to intrinsically withstand the line pressure in the process piping, resulting in an effective pressure rating of the element matching that of the process piping. This feature permits substantial design and manufacturing cost savings without sacrifice of metering performance. Accuracy, low installed cost. long service life and design flexibility are key characteristics of these primary flow elements. Static Inlet tap and Grouted-In designs are used for larger line size. Element Data and Description Size 1” to 144” Pressure Ratings ANSI 150# to 2500# Β 0.3 to 0.75 Temperature -4000F to 12500F Accuracy ±0.5% actual reading
±0.25% actual reading with hydraulic calibration Rage-ability 100:1 or more according to secondary instruments arrangement Materials (listed but not limited to)
Carbon steel, chrome-moly steel, inconel, zirconium, hastelloy B & C, 316 stainless steel, 304 stainless steel, aluminum, titanium, duplex S/S, monel
SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond, BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
SFC-VT-PI Series Insertion Venturi The SFC-VT-PI insert primary flow element consists of a hydraulic shape ruggedly constructed on a properly sized center flange that fits within the bolt circle of the mating process piping. It is all plastic or fiberglass design, utilizing DERAKANE* Epoxy Vinyl Ester Resin. It is non-corrosive, self scouring, dimensionally stable and can be used with line temperatures of up to 180℉ (standard resin) and up to 250℉ (high temperature resin). The high and low pressure connections are 316 stainless steel. The Venturi is supplied with integral neoprene flange gaskets that are ready for installation. This equipment is a very inexpensive alternative for gas flow measurement, where on-site power is unavailable, and lower accuracy is acceptable. Element Data and Description Size 0.75” to 120” Pressure Ratings From full vacuum to the line pressure limit Temperature 1800F to 2500F Accuracy ±0.5% actual reading
±0.25% actual reading with hydraulic calibration Rage-ability 100:1 or more according to secondary instruments arrangement The insertion type venturi is a short laying length design featuring high accuracy and low permanent pressure loss. The flow conditions within the inlet section allow for closer coupling with upstream pipe fittings. Should pressure drop be of importance, the outlet cone can be extended to satisfy the user's head-loss requirements. Warranty: Unaffected by downstream piping, Custom designed for specific application , Bi-Directional designs are available, Field verifiable. The device performance and metering similitude shall be substantiated by manufacturer's traceable independent testing. Performance substantiation shall include coefficient value, predictability, effects from installation and line pressure loss from hydraulic shape.
SFC SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
6
SKYLINE FLOW CONTROLS,INC. SFC-Manufacture Shop115-13431 Maycrest Way,Richmond,BC,Ca.Phone:+1-604-285-6890,Fax:+1-604-285-6891Email:[email protected]
Alderbridge Way,Richmond,BC,Canada,CaPhone:(604)-276-1482,Fax:(604)-276-1482-1
www.skylineflowcontrols.com
SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond, BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
SFC-VT-FI , Series Insertion Venturi For applications where limited installation space is a concern for typical venturi meter, the SFC-VT-FI series venturi meter is the most optimal choice due to its unique design. In addition, it cost less than the ordinary venturi. The SFC-VT-FI, Insert Type Venturi primary flow element is a full performance, high accuracy and reliability differential producing flow measurement device that is thoroughly substantiated for 2 sigma performance as indicated below. This equip-ment differs from the SFC-VT pressure vessel meter design in that the hydraulic shape is ruggedly constructed on a properly sized center flange that fits within the bolt circle of the mating process piping. Thus the insert (center flange), is captured between the mating pipe flanges and does not need to intrinsically withstand the line pressure in the process piping, resulting in an effective pressure rating of the element matching that of the process piping. This feature permits substantial design and manufacturing cost savings without sacrifice of metering performance. Accuracy, low installed cost. long service life and design flexibility are key characteristics of these primary flow elements. Static Inlet tap and Grouted-In designs are used for larger line size. Element Data and Description Size 1” to 144” Pressure Ratings ANSI 150# to 2500# Β 0.3 to 0.75 Temperature -4000F to 12500F Accuracy ±0.5% actual reading
±0.25% actual reading with hydraulic calibration Rage-ability 100:1 or more according to secondary instruments arrangement Materials (listed but not limited to)
Carbon steel, chrome-moly steel, inconel, zirconium, hastelloy B & C, 316 stainless steel, 304 stainless steel, aluminum, titanium, duplex S/S, monel
SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond, BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
SFC-VT-PI Series Insertion Venturi The SFC-VT-PI insert primary flow element consists of a hydraulic shape ruggedly constructed on a properly sized center flange that fits within the bolt circle of the mating process piping. It is all plastic or fiberglass design, utilizing DERAKANE* Epoxy Vinyl Ester Resin. It is non-corrosive, self scouring, dimensionally stable and can be used with line temperatures of up to 180℉ (standard resin) and up to 250℉ (high temperature resin). The high and low pressure connections are 316 stainless steel. The Venturi is supplied with integral neoprene flange gaskets that are ready for installation. This equipment is a very inexpensive alternative for gas flow measurement, where on-site power is unavailable, and lower accuracy is acceptable. Element Data and Description Size 0.75” to 120” Pressure Ratings From full vacuum to the line pressure limit Temperature 1800F to 2500F Accuracy ±0.5% actual reading
±0.25% actual reading with hydraulic calibration Rage-ability 100:1 or more according to secondary instruments arrangement The insertion type venturi is a short laying length design featuring high accuracy and low permanent pressure loss. The flow conditions within the inlet section allow for closer coupling with upstream pipe fittings. Should pressure drop be of importance, the outlet cone can be extended to satisfy the user's head-loss requirements. Warranty: Unaffected by downstream piping, Custom designed for specific application , Bi-Directional designs are available, Field verifiable. The device performance and metering similitude shall be substantiated by manufacturer's traceable independent testing. Performance substantiation shall include coefficient value, predictability, effects from installation and line pressure loss from hydraulic shape.
SFCSKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
7
SKYLINE FLOW CONTROLS,INC. SFC-Manufacture Shop115-13431 Maycrest Way,Richmond,BC,Ca.Phone:+1-604-285-6890,Fax:+1-604-285-6891Email:[email protected]
Alderbridge Way,Richmond,BC,Canada,CaPhone:(604)-276-1482,Fax:(604)-276-1482-1
www.skylineflowcontrols.com
SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond, BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
Figure 1: General Installation Drawing (Dual sensor, split range configuration)
SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond , BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
PROPERTIES OF VARIOUS GASES
APPLICABLE TO:AIR WEIGHT,GAS VOLUMETRIC,GAS WEIGHT
NAME(CHEMICAL FORMULA)
MOLEWEIGHT
SP.GRAVITY CP/CV CRITICAL
PRESSURECRITICAL
TEMP.
ACETYLENE (C2H2) 26.036 0.8986 1.26 891 95.3
AIR (N2O2) 28.962 1.0 1.41 547 -221
AMMONIA (NH3) 17.032 0.5878 1.31 1657 271
ARGON (Ar) 39.948 1.379 1.668 705 -188
BENZENE (C6H6) 70.114 2.42 1.08 709.8 552.1
BUTANE (C4H10) 70.114 2.42 1.08 709.8 552.1
CARBON DIOXIDE (CO2) 44.040 1.5188 1.30 1073 88
CARBON MONOXIDE (CO) 28.010 0.9667 1.404 510 -218
CHLORINE (CL2) 70.914 2.447 1.355 1120 291
ETHANE (C2H6) 30.066 1.038 1.193 708 90
ETHYLENE (C2H4) 28.052 0.9681 1.243 742 50
HELIUM (HE) 4.000 0.13805 1.660 33 -450
HYDROGEN (H2) 2.016 0.0696 1.41 188 -400
HYDROGEN CHLORIDE (HCL) 36.465 1.2585 1.405 1199 125
HYDROGEN SULFIDE (H2S) 34.076 1.176 1.320 1306 213
METHANE (CH4) 16.042 0.5536 1.308 673 -117
NITRIC OXIDE (NO) 30.010 1.0357 1.380 956 -137
NITROGEN (N2) 28.016 0.9669 1.404 492 -233
OXYGEN (O2) 32.000 1.1044 1.401 730 -182
OZONE (O3) 47.998 1.6572 (-) 800 16
PROPANE (C3H8) 44.094 1.5218 1.133 617 206
PROPYLENE (C3H6) 42.078 1.4522 1.1538 667 197
SULFUR DIOXIDE (SO2) 64.060 2.2109 1.240 1142 315
WATER (H2O) 18.016 0.6218 1.335 3206 705
SFC SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
8
SKYLINE FLOW CONTROLS,INC. SFC-Manufacture Shop115-13431 Maycrest Way,Richmond,BC,Ca.Phone:+1-604-285-6890,Fax:+1-604-285-6891Email:[email protected]
Alderbridge Way,Richmond,BC,Canada,CaPhone:(604)-276-1482,Fax:(604)-276-1482-1
www.skylineflowcontrols.com
SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond, BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
Figure 1: General Installation Drawing (Dual sensor, split range configuration)
SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond , BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
PROPERTIES OF VARIOUS GASES
APPLICABLE TO:AIR WEIGHT,GAS VOLUMETRIC,GAS WEIGHT
NAME(CHEMICAL FORMULA)
MOLEWEIGHT
SP.GRAVITY CP/CV CRITICAL
PRESSURECRITICAL
TEMP.
ACETYLENE (C2H2) 26.036 0.8986 1.26 891 95.3
AIR (N2O2) 28.962 1.0 1.41 547 -221
AMMONIA (NH3) 17.032 0.5878 1.31 1657 271
ARGON (Ar) 39.948 1.379 1.668 705 -188
BENZENE (C6H6) 70.114 2.42 1.08 709.8 552.1
BUTANE (C4H10) 70.114 2.42 1.08 709.8 552.1
CARBON DIOXIDE (CO2) 44.040 1.5188 1.30 1073 88
CARBON MONOXIDE (CO) 28.010 0.9667 1.404 510 -218
CHLORINE (CL2) 70.914 2.447 1.355 1120 291
ETHANE (C2H6) 30.066 1.038 1.193 708 90
ETHYLENE (C2H4) 28.052 0.9681 1.243 742 50
HELIUM (HE) 4.000 0.13805 1.660 33 -450
HYDROGEN (H2) 2.016 0.0696 1.41 188 -400
HYDROGEN CHLORIDE (HCL) 36.465 1.2585 1.405 1199 125
HYDROGEN SULFIDE (H2S) 34.076 1.176 1.320 1306 213
METHANE (CH4) 16.042 0.5536 1.308 673 -117
NITRIC OXIDE (NO) 30.010 1.0357 1.380 956 -137
NITROGEN (N2) 28.016 0.9669 1.404 492 -233
OXYGEN (O2) 32.000 1.1044 1.401 730 -182
OZONE (O3) 47.998 1.6572 (-) 800 16
PROPANE (C3H8) 44.094 1.5218 1.133 617 206
PROPYLENE (C3H6) 42.078 1.4522 1.1538 667 197
SULFUR DIOXIDE (SO2) 64.060 2.2109 1.240 1142 315
WATER (H2O) 18.016 0.6218 1.335 3206 705
SFCSKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
9
SKYLINE FLOW CONTROLS,INC. SFC-Manufacture Shop115-13431 Maycrest Way,Richmond,BC,Ca.Phone:+1-604-285-6890,Fax:+1-604-285-6891Email:[email protected]
Alderbridge Way,Richmond,BC,Canada,CaPhone:(604)-276-1482,Fax:(604)-276-1482-1
www.skylineflowcontrols.com
SteelSteelSteelSteelCompositionsCompositionsCompositionsCompositions
ASTM Specifications and GradeMarkingSymbol
PipeCode
PlateCode
ForgingCode
Cast steelCode
Carbon steel(C≤0.25%) WPA A106A A285-B A181-1,A105 --
Carbon steel(C≤0.30%) WPB A106B A515-65 or 70 A181-2,A105 A216-WCB
Carbon steel(C≤0.33%) WPC A106C -- -- A216-WCC
SteelSteelSteelSteel forforforfor CryonicCryonicCryonicCryonicA1 Killed Steel A537-C1.1 WPL6 A333,A334-6 A516,65,70 A350-LF2 A352-LCB
2.5% Ni Steel WPL2 A333,A334-2 A352-LC2
3.5% Ni Steel WPL3 A333,A334-3 A203-D A350-LF3 A352-LC3
9% Ni Steel WPL8 A333,A334-8 A353 A522 A352-LC8
Cr-MoCr-MoCr-MoCr-Mo AlloyAlloyAlloyAlloy0.5% Molybdenum WP1 A335-P1 A204-B A182-F1 A217 WC1
1%Cr-0.5% Molybdenum WP12 A335-P12 A387-12 A182-F12 --
1.25%Cr-1%Molybdenum WP11 A335-P11 A387-11 A182-F11 A217 WC6
2.25%Cr-1%Molybdenum WP22 A335-P22 A387-22 A182-F22 A217 WC9
5%Cr-0.25%Molybdenum WP5 A335-P5 A387-5 A182-F5 A217 WC5
7%Cr-0.5%Molybdenum WP7 A335-P7 -- A182-F7 --
9%Cr-0.5%Molybdenum WP9 A335-P9 -- A182-F9 A217 WC12
9%Cr-0.5%Mo-VCbN WP91 A335-P91 A182-F91 A217 WC12A
9%cR-0.5%Mo-1.5%W-VCBNiN WP92 A335-P92 A182-F92
StainlessStainlessStainlessStainless SteelSteelSteelSteel18%Cr-8%Ni WP304 A312-TP304 A240-Type304 A182-F304 A351 CF8
18%Cr-8%Ni-(0.04-0.1)%C WP304H A312-TP304H A240-Type304H A182-F304H
18%Cr-8%Ni-0.035%C WP304L A312-TP304L A240-Type304L A182-F304L A351 CF3
22%Cr-12%Ni WP309 A312-TP309 A240-Type309S -- --
25%Cr-20%Ni WP310 A312-TP310S A240-Type310S A182-F310 A351 CK20
18%Cr-8%Ni-Mo WP316 A312-TP316 A240-Type316 A182-F316 A351 CF8M
18%Cr-8%Ni+Mo-(0.04-0.1)%C WP316H A312-TP316H A240-Type316 H182-F316H --
18%Cr-8%Ni+Mo-0.035C WP316L A312-TP316L A240-Type316L A182-F316L A351 CF3M
18%Cr-8%Ni-Ti WP321 A312-TP321 A240-Type321 A182-F321 A351 CF10
18%Cr-8%Ni+Ti-(0.04-0.1)%C WP321H A312-TP321H A240-Type321H A182-F321H --
18%Cr-8%Ni+Cb+Tb WP347 A312-TP347 A240-Type347 A182-F347 A351 CF8C
18%Cr-8%Ni+Vb+Ta+(0.04-0.1)%C WP347H A312-TP347H A240-Type347H A182-F347H --
25%Cr-5%Ni-1%Mo WP329JI A268-TP329 -- -- --
SKYLINE FLOW CONTROLS INC. . The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond , BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
SKYLINE FLOW CONTROLS, INC.115 - 13431 Maycrest Way, Richmond, BC V6X 2A4, Ca. Phone: +1-604–285-6890, Fax: +1-604–285-6891Email: [email protected]
SFC-ABCO SHOPAlderbridge Way, Richmond, BC, Canada, V6X 2A4
Phone: (604)-276-1482, Fax: (604)-276-1482-1www.skylineflowcontrols.com
Skyline Flow Controls – Wedge Meter (SFC-WM) The SFC wedge meter is a differential pressure device for use on all fluids. It is especially designed for slurries and liquids with suspended solids. The SFC-WM is also particularly effective on highly viscous fluids. The meter can also detect pipe flow of fluids with Reynold number as low as 500. SFC-WM can also be used for bi-directional flows. Pressure tapping is available in both flanged or screwed configuration. A remote seal connection is also available for DP transmitters.
DESCRIPTION & APPLICATIONS:
• Rugged and robust design • Low permanent pressure loss • Pipe Size: 1.5 in to 24 in (40mm to 600mm) • Chemical seals available for hazardous applications • Flow measurement of high viscosity liquids • Flow measurement of low Reynolds number fluids • Well suited for slurries applications • Bi-directional flow measurement
ADVANTAGES:
• Proven flow metering technology • Rugged design which can withstand slurries and suspended solids • Flow measurement with NO moving parts • Low maintenance due to anti-wear and erosion preventive design • Energy savings due to permanent low pressure drops
Skyline Flow Controls - Wedge Meter (SFC-WM)
SFC SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement
10
SKYLINE FLOW CONTROLS,INC. SFC-Manufacture Shop115-13431 Maycrest Way,Richmond,BC,Ca.Phone:+1-604-285-6890,Fax:+1-604-285-6891Email:[email protected]
Alderbridge Way,Richmond,BC,Canada,CaPhone:(604)-276-1482,Fax:(604)-276-1482-1
www.skylineflowcontrols.com