Download - Simulator Theory and Operation
Rev 3.09 13-1
Simulator Simulator Theory and Theory and OperationOperation
Rev 3.09 13-2
EACH BREATH TEST MUST BE PRECEEDED BY A EACH BREATH TEST MUST BE PRECEEDED BY A REFERENCE ANALYSIS REFERENCE ANALYSIS
REQUIRED BY THE CDPHE RULES AND REQUIRED BY THE CDPHE RULES AND REGULATIONS, 5 CRR 1005-2REGULATIONS, 5 CRR 1005-2
THE DEVICE USED TO GENERATE THE THE DEVICE USED TO GENERATE THE REFERENCE VAPOR IS CALLED BREATH REFERENCE VAPOR IS CALLED BREATH ALCOHOL SIMULATOR OR “SIMULATOR”ALCOHOL SIMULATOR OR “SIMULATOR”
H2O AND ETOH IS USED IN LUE OF BLOOD H2O AND ETOH IS USED IN LUE OF BLOOD AND ETOHAND ETOH
Use and TheoryUse and Theory
Rev 3.09 13-3
Use and TheoryUse and Theory
THE AMOUNT OF ETOH IN 2100 ml OF THE AMOUNT OF ETOH IN 2100 ml OF DEEP LUNG AIR AT 34.0DEEP LUNG AIR AT 34.0CC ETOHETOH ININ 1 1 ml OF ATERIAL BLOODml OF ATERIAL BLOOD
SIMULATOR SOLUTIONSIMULATOR SOLUTION0.100 grams OF ETOH PER 2100 Liters 0.100 grams OF ETOH PER 2100 Liters OF AIR AT 34.0OF AIR AT 34.0CC
PREPARED BY CERTIFICATION UNITPREPARED BY CERTIFICATION UNIT VALIDATES THE PERFORMANCE OF THE VALIDATES THE PERFORMANCE OF THE
5000EN5000EN
Rev 3.09 13-4
Functional StructureFunctional Structure
AIR INLET TUBE
ON/OFF-RESET SWITCH
HEATERINDICATOR
VAPOR PORT
BAFFLE PLATES
GLASS CONTAINER
HEATING ELEMENT
HIGH INTENSITY L.E.D. DISPLAY
AGITATOR
TEMPERATURESENSOR
DISPERSION TUBE
Rev 3.09 13-5
Exclusive Features of the Guth Exclusive Features of the Guth Model 2100 SimulatorModel 2100 Simulator
MICROPROCESSOR ENHANCEDMICROPROCESSOR ENHANCED:: --PERFORMSPERFORMS INTERNAL INTERNAL
DIAGNOSTICSDIAGNOSTICS --MONITERSMONITERS TEMPERATURE TEMPERATURE SENSOR, RFISENSOR, RFI CIRCUITRY CIRCUITRY
--CONTROLS CONTROLS AGITATOR MOTOR, DISPLAY AGITATOR MOTOR, DISPLAY DRIVER, COMMUNICATIONS AND A/V DRIVER, COMMUNICATIONS AND A/V
INFORMATIONINFORMATION
Rev 3.09 13-6
TEMPERATURE SENSOR:TEMPERATURE SENSOR:-RUGGED DESIGN: STAINLESS STEEL, -RUGGED DESIGN: STAINLESS STEEL,
BRASSBRASS-STABLE TEMPERATURE -STABLE TEMPERATURE
RANGE:RANGE: MAINTAINS MAINTAINS A PRECISE A PRECISE RANGE OF 34RANGE OF 34C C .02 .02CC
-ACCURACY -ACCURACY OF INSTRUMENT TEMPERATURE OF INSTRUMENT TEMPERATURE
READING IS READING IS .05 .05CC
Exclusive Features of the Guth Exclusive Features of the Guth Model 2100 SimulatorModel 2100 Simulator
Rev 3.09 13-7
ELECTRONICALLY PROTECTED:ELECTRONICALLY PROTECTED: -INTERNAL -INTERNAL POWER TRANSFORMER ANDPOWER TRANSFORMER AND
OPTICALLY ISOLATED CONTROL COMPONENTS OPTICALLY ISOLATED CONTROL COMPONENTS PREVENTS A.C. LEAKAGE TO ELECTRONICSPREVENTS A.C. LEAKAGE TO ELECTRONICS
-R.F.I. PROTECTED-R.F.I. PROTECTED
-HEATING ELEMENT PROTECTED FROM OVER -HEATING ELEMENT PROTECTED FROM OVER HEATING WHEN TEMPERATURE SENS0R IS DEFECTIVE HEATING WHEN TEMPERATURE SENS0R IS DEFECTIVE OROR REMOVED FROM SOLUTION REMOVED FROM SOLUTION
-EXTERNAL FUSE PROVIDES PROTECTION IN CASE OF -EXTERNAL FUSE PROVIDES PROTECTION IN CASE OF ELECTRICAL ELECTRICAL MALFUNCTIONMALFUNCTION
Exclusive Features of the Guth Exclusive Features of the Guth Model 2100 SimulatorModel 2100 Simulator
Rev 3.09 13-8
Guth Simulator Error CodesGuth Simulator Error Codes
MESSAGE PLATEMESSAGE PLATE
MOUNTED ON MOUNTED ON SIMULATORSIMULATOR
QUICK QUICK REFERENCEREFERENCE
GUIDE GUIDE
Rev 3.09 13-9
CAUSE: NO SOLUTION IN CONTAINER OR SIMULATOR WAS POWERED UP WITHOUT TOP HOUSING ATTACHED TO CONTAINER. REMEDY: TURN OFF THE SIMULATOR, FILL WITH SOLUTION AND REASSEMBLE.
CAUSE: THE TEMPERATURE SENSOR IS OPEN OR SHORTED. COMPUTER IS RECEIVING NO SIGNAL TO ALLOW IT TO CONTROL THE TEMPERATURE. REMEDY: THIS CAN’T BE REMEDIED IN THE FIELD. REQUIRES SERVICE *
CAUSE: THE ELECTRONICS NEED TO BE RESET. REMEDY: TURN OFF, WAIT 3-5 SECONDS, THEN TURN ON. IF THE SIMULATOR REPEATS THIS ERROR CODE. CALL FOR ASSISTANCE *
* NOTIFY CDPHE
Guth Simulator Error CodesGuth Simulator Error Codes
Rev 3.09 13-10
CAUSE:
TEMPERATURE OF THE SOLUTION IS ABOVE 34.2C OR RFI HAS BEEN DETECTED. REMEDY: REMOVE THE SOURCE OF THE INTERFERENCE OR CHANGE THE LOCATION OF THE SIMULATOR. RESET THE SIMULATOR.
CAUSE:
ELECTRONICS NEED TO BE RESET. REMEDY: RESET THE SIMULATOR.
CAUSE: EXCESSIVE AMOUNT OF TIME TO OBTAIN OPERATING TEMPERATURE (+15 MINUTES). THE HEATING ELEMENT MAYBE OPEN OR THE SOLUTION WAS TOO COLD. REMEDY: RESET THE SIMULATOR. IF THE SIMULATOR DOES NOT HEAT, THE HEATING ELEMENT MAY BE DEFECTIVE. REQUIRES SERVICE *
* NOTIFY CDPHE
Guth Simulator Error CodesGuth Simulator Error Codes
Rev 3.09 13-11
CAUSE: THE TEMPERATURE OF THE SOLUTION IS BELOW 33.8C AFTER IT HAS INITIALLY OBTAINED 34.0C. REMEDY: RESET THE SIMULATOR. IF THE SIMULATOR DOES NOT HEAT, THE HEATING ELEMENT MAY BE DEFECTIVE. REQUIRES SERVICE*
CAUSE: AN ERROR HAS OCCURRED WITH THE RS-232 COMMUNICATIONS EXTERNAL CONTROL OPTION. REMEDY:
RESET THE SIMULATOR. IF THE SIMULATOR REPEATS THIS ERROR CODE. CALL FOR ASSISTANCE *
CAUSE: AN ERROR HAS OCCURRED WITH THE READ OR WRITE MEMORY OPTION
COMMAND. REMEDY: RESET THE SIMULATOR. IF THE SIMULATOR REPEATS THE ERROR CODE, CALL FOR ASSISTANCE * (THIS ERROR SHOULDN"T OCCUR WITH COLORADO SIMULATORS!)
* NOTIFY CDPHE
Guth Simulator Error CodesGuth Simulator Error Codes
Rev 3.09 13-12
Correct Positioning of Correct Positioning of Simulator Tubing and ClampSimulator Tubing and Clamp
#1 #1 Shows the correct orientation of the Shows the correct orientation of the Simulator Tubing ElbowSimulator Tubing Elbow
#2 #2 Shows the correct positioning of the Shows the correct positioning of the
Simulator ClampSimulator Clamp
•Make sure the clamp is tightened all Make sure the clamp is tightened all the the way closedway closed
•When sending the simulator in for When sending the simulator in for repairs, repairs, remove the tubing at remove the tubing at the clamp and the clamp and
disconnect the heated tube at disconnect the heated tube at the the disconnect jointdisconnect joint •Keep all tubing and the jar at your Keep all tubing and the jar at your locationlocation
Rev 3.09 13-13